Preview only show first 10 pages with watermark. For full document please download

Deep Cycle Gel Type Sealed Lead Acid Battery 12gb12c

   EMBED


Share

Transcript

DEEP CYCLE GEL TYPE SEALED LEAD ACID BATTERY 12GB12C (12V 12Ah) SPECIFICATIONS Nominal Voltage (V) 12V Nominal Capacity 20 hour rate (0.60A to 10.50V) (2.04A to 10.20V) 5 hour rate (6.6A to 9.60V) 1 hour rate (12A to 9.60V) 1C Weight 12Ah 10.2Ah 6.6Ah 6.4Ah Approx. 4.03kg (8.87lbs) Internal Resistance (@1kHz) DIMENSIONS mm (inch) Maximum Discharge Current For 5 seconds 6.35 (0.25) 4.75 (0.19) Approx. 13mΩ Charging Methods @25ºC (77ºF) Cycle Use: Charging Voltage Coefficient -5.0mV/ºC/Cell Maximum Charging Current 13.80V to 14.40V Standby Use: Float Charging Voltage Coefficient -3.0mV/ºC/Cell 13.50V to 13.80V 0.8 (0.03) 0.8 (0.03) 180A F1 F2 3.6A 98±1(3.86±0.04) +40ºC (104ºF) +50ºC (122ºF) +40ºC (104ºF) Charge Retention (Shelf Life) @20ºC (68ºF) 1 month 3 months 6 months 92% 90% 80% Case Material ABS (v) 93±1(3.66±0.04) to to to 98±1(3.86±0.04) Operating Temperature Range -15ºC (5ºF) Charge -15ºC (5ºF) Discharge -15ºC (5ºF) Storage 151±1(5.94±0.04) 12GB12C 12V 12Ah Discharge Time VS. Discharge Current (25ºC) FOR 12V BATTERY 13.0 12.0 11.0 10.0 Terminal F1 or F2 (Faston Tab 187 or 250) 0.6A 2.04A 12A 6.6A 9.0 8.0 1 2 4 6 8 10 20 40 60 2 minutes Discharge Time http://www.drypower.com.au 5 6 hours 8 10 20 12GB12C (12V 12Ah) Effect of Temperature on Capacity 25ºC (77ºF) (%) 100 120 Capacity % Remaining Capacity 0.05CA 0.1CA 100 0.25CA 80 0.55CA 1CA 60 2CA 40 20 0 -20 -4 -10 14 0 32 10 50 20 68 30 86 Temperature 40 50 104 122 0 (32 ) 75 10 (50 ) 50 20 (68 ) 40 (104 ) 30 (86 ) 25 0 Trickle (or float) Service Life 3 6 9 12 15 18 Storage Time (months) Cycle Service Life 120 100 Capacity % 10 7 Life (years) Capacity Retention Characteristic 5 3 80 60 Discharge Depth 100% 40 2 (1) Discharge : 0.17CA (2) Charge : CV 2.4V/cell 16H Imax 0.3CA (3) End of life discharge voltage : 1.65 Vpc (4) Temperature : 25±2ºC 20 20 68 30 86 40 104 50 122 Ambient Temperature ( ( 0 ) ) Discharge Depth 30% Discharge Depth 50% 200 400 600 800 1000 1200 1400 1600 Number of Cycles (times) - PERFORMANCE DATA Discharge Rates in Watts to Various End Voltages at 25ºC (77ºF) Time 5 10 15 30 60 120 180 240 300 600 1200 End Voltage 1.85V 1.80V 1.75V 1.70V 1.67V 1.65V 1.60V min min min min min min min min min min min 367 243 167 101 78.4 45.5 31.5 26.2 23.3 13.4 6.79 416 278 205 118 84.5 48.2 33.6 27.7 24.2 13.9 7.06 446 302 229 131 87.7 49.9 35.1 28.9 24.9 14.3 7.29 468 320 248 140 89.6 51.4 36.3 29.8 25.6 14.7 7.59 479 329 253 143 90.4 51.9 36.7 30.2 25.9 14.8 7.68 490 332 259 146 91.1 52.5 37.2 30.6 26.2 15.0 7.77 509 341 265 149 92.0 53.2 37.7 31.1 26.6 15.2 7.94 - Discharge Rates in Amperes to Various End Voltages at 25ºC (77ºF) Time 5 10 15 30 60 120 180 240 300 600 1200 End Voltage 1.85V 1.80V 1.75V 1.70V 1.67V 1.65V 1.60V min min min min min min min min min min min 32.6 20.9 18.2 10.9 7.02 3.63 2.57 2.09 1.92 1.09 0.574 38.4 24.3 19.6 11.7 7.53 3.92 2.78 2.27 2.00 1.14 0.598 42.1 26.6 20.8 12.1 7.76 4.10 2.94 2.39 2.06 1.18 0.621 45.1 28.5 21.7 12.5 7.97 4.25 3.05 2.46 2.11 1.21 0.636 46.4 29.1 22.0 12.6 8.05 4.31 3.09 2.49 2.13 1.22 0.642 47.7 29.6 22.3 12.8 8.12 4.36 3.13 2.52 2.16 1.24 0.649 50.3 30.4 22.9 13.0 8.21 4.42 3.18 2.56 2.20 1.26 0.650 All data on the spec. sheet is an average value: The tolerance range : X<6min(+15%~-15%), 6min X<10min(+12%~-12%),10min X < 60min(+8% ~-8%), X 60min(+5%~-5%) Performance may vary depending on application. All specifications are correct at time of creation. All specifications and operation conditions contained in this datasheet are subject to change or improvement without prior notice to the user. This data is for evaluation purposes only. No guarantee is intended or implied by this data. For clarification and updated information, please contact us. http://www.drypower.com.au