Transcript
Dell Wyse 7040 Thin Client with Windows Embedded Standard 7P Release Notes
Contents Release Type and Definition ....................................................................................................................4 Release Scope ............................................................................................................................................4 Release Date ...............................................................................................................................................4 Client Software Licensing and Maintenance Options ........................................................................4 New Features.............................................................................................................................................. 5 Unified build ........................................................................................................................................... 5 General Features ........................................................................................................................................ 5 Imaging support using WDM/USB...................................................................................................... 5 Hardware Support Information ........................................................................................................... 5 Dell supports vPRO Corporate SKUs .................................................................................................6 Menu Driven Custom/ConfigMgr Sysprep .......................................................................................6 New Versions of Connection Brokers ...............................................................................................6 Out of Box Driver Install .......................................................................................................................6 Newer Dell Wallpapers .........................................................................................................................6 New Dell BIOS ........................................................................................................................................6 Dell Command Configure (DCC) .......................................................................................................6 XML driven PowerShell scripts ............................................................................................................6 Logging support..................................................................................................................................... 7 WES7P Image Structure ............................................................................................................................ 7 WES7P 7020 Build behavior..................................................................................................................... 7 Internet Explorer 11 ............................................................................................................................... 7 Citrix Receiver ........................................................................................................................................8 Energy Star Specification .....................................................................................................................8 Microsoft SCCM 2012 R2 Information ..............................................................................................8 Wyse Configuration Manager Behavior.............................................................................................8 Dell Wyse vWorkspace .........................................................................................................................8 C-A-D Tool ............................................................................................................................................. 9 Flash.sys ................................................................................................................................................... 9 Event Viewer log preservation ............................................................................................................ 9 Dell Wyse 7040 Thin Client with Windows Embedded Standard 7P Release Notes
Page 2 of 22
Dell Thin Client Application ................................................................................................................. 9 Tested Peripherals ................................................................................................................................... 10 Fixed Issues ............................................................................................................................................... 11 Known Issues ............................................................................................................................................ 11 Build Information ..................................................................................................................................... 15 User and Free space details ........................................................................................................... 16 OS Components ...................................................................................................................................... 17 Driver details ..................................................................................................................................... 17 Common Applications/Features/Files ......................................................................................... 17 QFEs Added in the Release ................................................................................................................... 20 Security Updates ............................................................................................................................. 20
Dell Wyse 7040 Thin Client with Windows Embedded Standard 7P Release Notes
Page 3 of 22
Release Type and Definition The WES7P v9.05 unified build 7020 is a 64-bit Image which supports English (enUS), French Canadian (fr-CA), Japanese (ja-JP) and German (de-DE) for Dell Wyse 7040 thin client. This product is a variant of the OptiPlex 7040 Micro Chassis with the wireless module or expansion capability replaced by a fiber module. This build can be pushed on 128 GB SSD, 256 GB SED, and 500 GB HDD or above combination with 4/8/16 GB RAM. This build is Windows 10 IoT Enterprise (WIE10) upgrade capable.
Release Scope The WES7P v9.05 unified build 7020 supports English (en-US) and 3 MUI Languages.
German (de-DE)
French Canadian (fr-CA)
Japanese (ja-JP)
Release Date November 29, 2016
Client Software Licensing and Maintenance Options Dell Wyse thin client software maintenance is required to receive new versions of thin client software and subsequent releases of corresponding documentation and tools. Use of this software on more than one device requires you to first purchase the additional copies of, or licenses to, the software from Dell Wyse.
Dell Wyse 7040 Thin Client with Windows Embedded Standard 7P Release Notes
Page 4 of 22
New Features This section provides the list of new features in this release. Unified build This build supports English (en-US) and three MUI languages —fr-CA, ja-JP, and deDE.
General Features Imaging support using WDM/USB Imaging units using WDM/ USB has two scenarios depending on type of build on which it is being pushed.
Non-Unified build
For updating Unified MUI build, on top of the non-unified build is a two-step process. 1. The WDM Add-on is used to write the desired languages metadata to the Merlin partition of the non-unified build. The command line (For FrenchCanada LanguageConfig.exe fr-FR) language option can be pushed to the client to write the required language metadata to the Merlin partition by using the WDM add-on with the Unified Language selection tool LanguageConfig.exe. 2. Push the Unified MUI image on top of the non-unified build with language metadata in Merlin partition. Imaging brings up the unit in the same MUI language present in Merlin.
Unified MUI build
As the unified MUI build has the language metadata in Merlin partition, imaging the Unified MUI build brings up the unit in the same MUI language present in Merlin. If you want to change the language, then the Unified Language selection tool LanguageConfig.exe can be used to write the language metadata to Merlin partition. Reimaging the unit with the unified MUI build brings up the unit in desired language option selected with the tool. Hardware Support Information This release supports the following hardware:
Intel vPRO support—Four different SKUs from Dell i5 and i7 processor options. M.2 slot based SSD and SATA-based SSD options. 4 GB, 8 GB, and 16 GB RAM options. Copper or Fiber SFP Module support. Support for Self-Encrypting Drive (SED). Intel HD Graphics support with HDMI and DP.
Dell Wyse 7040 Thin Client with Windows Embedded Standard 7P Release Notes
Page 5 of 22
Intel RAPID Storage support.
Dell supports vPRO Corporate SKUs
vPRO
MEDISABLE
MELOCKOUT
ISM
Menu Driven Custom/ConfigMgr Sysprep
Supports Menu driven Custom/ConfigMgr Sysprep where you can select the particular option.
Shrinking of disk information available during Sysprep that reduces the image pull or push time in larger disks.
New Versions of Connection Brokers The new versions of the connection brokers that are available are:
VMware Horizon Client: 3.5.2.30397
Citrix Receiver: 14.4.0.8014
Dell Wyse vWorkspace Connector: 8.6.309.4062
Out of Box Driver Install All the respective device drivers are preinstalled in the OS, as compared to the legacy approach wherein there were prestaged drivers. Newer Dell Wallpapers Wyse wallpapers and themes are replaced with the Dell wallpapers and themes. New Dell BIOS
New BIOS with the Wyse extension.
Support for both “AHCI” and “RAID ON” SATA mode. ”RAID ON” mode for standard drives and “AHCI” mode for SED drives in factory configuration.
Note: For this hardware platform BIOS is not bundled with the image.
Dell Command Configure (DCC) It is packaged software offering that provides GUI and scripted BIOS configuration capability to the Dell business client platforms. XML driven PowerShell scripts Customization scripts are ported to the PowerShell scripts and based on .XML file input. Dell Wyse 7040 Thin Client with Windows Embedded Standard 7P Release Notes
Page 6 of 22
Logging support Logging support added for customization scripts.
WES7P Image Structure
WES7P build has five partitions – 100 MB Merlin partition, 350 MB Recovery, 100 MB EFI System partition, 128 MB MSR partition, and rest as OS partition.
100 MB Merlin partition is showing as FAT32 without the Drive Letter in Disk Management. 100 MB EFI System partition contains Merlin BA (Boot Agent) Version 3.3.7.
WES7P 7020 builds will be in compressed format.
Added support for UEFI boot and Windows 10 upgrade. Following are the changes that were done with respect to supporting UEFI boot and Windows 10 upgrade: o Partition type is changed to GPT partition. o 5 Partition structure is used and scripts are modified to adapt this new partition structure. o Merlin.ps1 file added and called to toggle Merlin Non-Pxe to first in the boot order instead of calling BAactive which was used in the build that support MBR partition structure. o License Manager Tool for managing Windows 10 license added under the path C:\Windows\Setup\Tools which will manage the license.txt file that will be copied to the path C:\Windows\Setup\License in factory for supporting Windows 10 upgrade support.
WES7P 7020 Build behavior Internet Explorer 11
Performance enhancements: IE 11 is the quickest version of the browser yet. Microsoft has included support for web standards like CSS animations, HTML5 spell checking, and improved JavaScript performance.
Security enhancements: The main security addition to IE 11 is Enhanced Protected Mode, which will lock down parts of the Windows operating system, preventing the browser from accessing the OS. IE Customizations a) First run customizations is disabled. b) IE 11 enhanced protection mode is enabled. c) Start page and default page set to www.dell.com/wyse d) IE Cookies and Cache are redirected to Z: e) Cache content to 50 MB. f) Clears browsing history on IE exit.
Dell Wyse 7040 Thin Client with Windows Embedded Standard 7P Release Notes
Page 7 of 22
Citrix Receiver USB redirection always works for all users of the client machine with all the published XenDesktop, irrespective of the setting Simplify device connections for me in the XenDesktop connection preferences UI. Energy Star Specification This product meets the ENERGY STAR version 6.0 of the thin client requirement. Below are the values by default set in the Control Panel applet of Power Options:
Supports WOL Power off states.
Supports Idle State wake.
Screen off timer set to 10 minutes.
Sleep timer set to 15 minutes.
Microsoft SCCM 2012 R2 Information
SCCM Information is not present in Programs and features and client information because of the Microsoft design.
Only Configuration Manager Control Panel Applet and SMS Agent Host Service are present.
SMSCFG.ini, clientstate.dat, wedmtrace.log, Ccmstore.sdf, InventoryStore.sdf, StateMessageStore.sdf files and the ServiceData folder are included in FBWF Exclusion list.
For more details refer the Dell Wyse Configuration Admin guide.
Wyse Configuration Manager Behavior
WCM service is enabled by default in this WES7P 7020 build. Following are the behavior if WCM service is enabled in the build: o If Network Cable is connected, and WCM is not configured in that network, then WCM Flash Screen appears and immediately disappears before logon to the Users. o In case WCM is configured in the Network, and same network cable is connected to the client, then it starts downloading the WCM. Configuration Settings from server and apply to client before logon to the Users. o If no network cable is connected, then WCM Splash Screen appears and stays for a few Seconds before logon to the Users.
For more information of WCM, Please refer the Dell Wyse Configuration Manager 1.3 Release Document. Dell Wyse vWorkspace After installation of Dell Wyse vWorkspace, install .txt file is created in C:\
Dell Wyse 7040 Thin Client with Windows Embedded Standard 7P Release Notes
Page 8 of 22
C-A-D Tool By default the build contains C-A-D tool, but in a disabled state. To enable the C-A-D tool, do the following: 1. Log in to the system using Admin account. 2. Disable the Write Filter. 3. Start command prompt in elevated mode. 4. Enter cd c:\windows\system32. 5. Run DWKBFilterMon.exe –enable and reboot. 6. Enable the Write Filter. Flash.sys Hostname Calculation and Preservation – This option allows you to enable and disable the Hostname Calculation in flash.sys.
You can disable or enable the Hostname Calculation.
Ensure that altering the MAC ID for a client does not perform a Host name Calculation.
If you require a host name calculation to perform after a change in MAC ID (NIC card change), then you must use MINWITHNET.
Event Viewer log preservation This feature allows you to enable or disable Event Viewer log saving while Write Filter (FBWF) is on. This feature enables you to collect event logs if they are required for debugging or analysis purposes. Dell Thin Client Application
Dell Client Application is a replacement for Client Information Application with a new User Interface (UI).
This application contains more fields for accessing and configuring Custom Fields, RAM Disk, Auto Logon, C-A-D Map Tool, and System Shortcuts.
By default, the RAM disk size is set to 512 MB.
Dell Wyse 7040 Thin Client with Windows Embedded Standard 7P Release Notes
Page 9 of 22
Tested Peripherals Device Name Dell USB Mouse(M/N: M-UAV-DEL8) Dell Wireless Mouse (M/N: WM514) Dell Wireless Mouse (M/N: WM324) Dell Wireless Mouse (M/N: WM123) Dell USB Laser 6 button mouse Dell Wireless Mouse (M/N: WM326) Dell Wireless Mouse (M/N: WM526) Dell Optical Mouse MS116 Dell Wireless Keyboard and Mouse KM714 Logitech Wireless Keyboard K350 Logitech Wireless Keyboard and Mouse mk520 Logitech Wireless Keyboard and Mouse mk710 Dell Wireless Keyboard and Mouse KM636 Dell Multimedia Keyboard K216 Dell USB Headset HSC011 (Jabra UC Voice 550a MS) Dell 2.0 Speakers AX210 Dell USB Soundbar AC511 Plantronics C510-M DP to HDMI converter DP to DVI converter DP to VGA converter Dell MR 2217 Monitor Dell UP2716D Monitor Dell P2014H Monitor Dell U2414H Monitor Dell UP2715Kt Monitor Dell P2414H Monitor Dell Wyse 7040 Thin Client with Windows Embedded Standard 7P Release Notes
Page 10 of 22
Dell P2415 Monitor Dell U2715H Monitor Dell P1914S Monitor Dell P2214H Monitor Dell P2314H Monitor Dell P2415Q Monitor Dell P2213 Monitor Dell UP2516D Monitor Dell UZ2315H Monitor Dell E2414H Monitor Logitech Web cam C525 Dell mono printer B5460dn Dell mono multifunction printer B5465dnf Dell multifunction printer E515dn
Fixed Issues None
Known Issues The following table lists the known issues in this release. Sl No. Issue Description
Notes
1.
BitLocker protection is turned off instead of suspend when executed custom sysprep.
NA
2.
Blank display seen on Dell UP2715K monitor (DP to
NA
DP cable). 3.
Remote FX devices redirection not working on Dell
NA
Wyse 7040 thin clients. 4.
Multi-touch is crashing inside the Citrix session.
Dell Wyse 7040 Thin Client with Windows Embedded Standard 7P Release Notes
NA
Page 11 of 22
5.
Multi-touch is not working inside RDP session.
NA
6.
Inbuilt monitor speaker not sensing in playback devices while NA connecting via HDMI or DP.
7.
Dell Wyse 7040: WDM Merlin non-pxe pull fails.
NA
8.
USB imaging is failing in Dell Wyse 7040 device when more than two USB devices are connected to the client.
Remove the extra USB devices before pulling/pushing an image.
9.
Low memory warning shows while playing YouTube videos.
NA
10.
Silverlight auto updates should be disabled for the thin clients. NA
11.
"Silverlight was blocked because it is out of date and needs to NA be updated" message appears while playing Silverlight videos.
12.
BIOS boot order list is missing in BIOS after executing
NA
DCC automation scripts. 13.
In Client Info "Flash" should be changed to secondary memory or the Internal memory.
NA
14.
Showing error message when press cancel button in
NA
Updating BIOS from the OS. 15.
Citrix receiver shortcut icon is missing in systray.
NA
16.
Intel ME crashes when connect the client OOB.
NA
17.
Dell open Printer driver is not working with Dell MFP
NA
e515dn Printer. 18.
While try to set the 1600 x 1200 Resolution via DP to
NA
VGA, Admin privilege error is shows.
Dell Wyse 7040 Thin Client with Windows Embedded Standard 7P Release Notes
Page 12 of 22
19.
Service tag is named as the Serial number in Dell
NA
Wyse Client Info. 20.
No error message appears when IP Conflict occurs.
NA
21.
Deletefreespace application is not executing if the folder "Deletefreespace" is already present under C:
NA
22.
Server Connection Retry Attempts is Exceeding 24 attempts during the discovery process.
NA
23.
Custom Sysprep script (Build Master) execution terminates NA abruptly while checking for TPM status in TPM and BitLocker enabled systems.
24.
Disk cleanup shortcut should be removed from start menu if NA support is not there.
25.
Two Windows Boot Manager option Present after
NA
Deploying Image from the SCCM. 26.
All installed modules are not listing in the client info.
NA
27.
Chinese character and the Chinese dialog box appear while booting after executing DCC Commands.
NA
28.
Unsupported Product IDs are listed registry under
NA
29.
WNT. Dell Wyse 7040: Client Taking 5 minutes to check in to WDM NA server through DHCP proxy services.
30.
BitLocker protection should suspend on executing
NA
“Build Master” if TPM is not initialized. 31.
Low disk space popup seen after playing HD 1080P
NA
videos from IE for 4-5 minutes.
Dell Wyse 7040 Thin Client with Windows Embedded Standard 7P Release Notes
Page 13 of 22
32.
Device Fails to install the driver software for printer
NA
HP Officejet 100, Error Message observed. 33.
UAC: System displays invalid alert message, when try to create a user account through a standard account.
NA
34.
Vworkspace: Show window Contents while dragging functionality is not working on WES7P.
NA
35.
TightVNC: VNC viewer (Remote Shadow in WDM) does not pass the Ctrl+Alt+Del command to the connected client.
NA
36.
IE is not responding when try to open the save webpage (YouTube) from desktop.
NA
37.
Dell logo is missing in the User contact path c:\Users\User\Contacts.
NA
38.
'Device installation settings' shows automatic driver updating NA checked.
39.
Unformatted Local Disk created after pushing fresh image using UBS 16 Gb with created data partition.
NA
40.
"Sleep" is not the default setting for "Sleep Button action” in the Power options.
NA
41.
WDM agent cannot execute commands in user context.
NA
42.
Windows Update shortcut is missing from Start Menu in the Administrator login after running Custom Sysprep scripts.
NA
Dell Wyse 7040 Thin Client with Windows Embedded Standard 7P Release Notes
Page 14 of 22
43.
Logoff and holding shift key does not take to the login screen NA when you use remote shadow from WDM server.
44.
WDM Applet: Updating WDM IP through WDM applet NA throwing error message. (Happening Immediate after opening WDM applet).
45.
The FBWF Cache size is set to 256 MB as Default instead of 512 MB.
NA
46.
"No boot device is found" Error message may be observed after pulling the image from WDM.
NA
47.
May be after downloading the image from USB, client is NA showing a message "Remove the USB and press enter to reboot" After removing the USB Pen drive— While pushing the pulled image.
48.
Bash command Prompt may display message "can't access NA tty: Job control turned off", while pulling image through WDM Merlin non-pxe.
Build Information General Build Details Platforms
Wyse 7040 Thin Client
Product
WES7P 7020 Unified build
Localization
English, French Canadian, German, and Japanese
Build Number
7020
WDM
5.7
BA version
3.3.7
USB Imaging Tool
2.1.1.2
Dell Wyse 7040 Thin Client with Windows Embedded Standard 7P Release Notes
Page 15 of 22
Platform Specific Build Details – WDM Package Wyse 7040 Thin Client Version
9.05
Build Size (Bytes)
13,084,698,422 bytes
Build Number
7020
Localization
English, French Canadian, German, and Japanese
BIOS Details Platform
Wyse 7040 Thin Client
Version
Wyse_7040_1.4.0
Build File Name
Wyse_7040_1.4.0
Note: An option to restore to BIOS defaults and Factory Defaults for Users is provided in BIOS menu. Restoring BIOS defaults restores the BIOS settings to the values that were part of BIOS file. Restoring Factory defaults restores the BIOS settings to the values that were configured in factory before shipping the client.
User and Free space details Platform
Flash Size
Used Space (C: drive)
Free Space
Wyse 7040 thin client (i5 processor)
500 GB
11.9 GB
453 GB
Wyse 7040 thin client (i5 processor)
256 GB
11.9 GB
225 GB
Wyse 7040 thin client (i5 processor)
128 GB
11.93 GB
106.65 GB
Wyse 7040 thin client (i7 processor)
500 GB
11.9 GB
453 GB
Wyse 7040 thin client (i7 processor)
256 GB
11.9 GB
225 GB
Wyse 7040 thin client (i7 processor)
128 GB
11.93 GB
106.65 GB
Dell Wyse 7040 Thin Client with Windows Embedded Standard 7P Release Notes
Page 16 of 22
OS Components Driver details Drivers/Files
Version
Display Adapter
20.19.15.4390
Ethernet Adapter
12.15.22.6
SFP Adapter
7.612.1231.2015
Realtek HD Audio
6.0.1.6098
Intel Display Audio
6.16.0.3191
USB xHCI driver
4.0.4.51
Wyse RAMDisk Driver
5.0.2183.4
flash.sys
1.0.6.6
Dell Open Print Drivers
1.91.7882.0
Chipset
10.1.1.9
Intel ME-vPRO
11.0.0.1166
Storage
14.8.1.1043
Common Applications/Features/Files Applications/Features/Files RDP
Version (If applicable) 6.3.9600 (Supports RDP 8.1)
Citrix Receiver (Standard)
4.4.0.8014 (In Citrix About)
Citrix Online Plugin
14.4.0.8014 (In client Information, Programs and Features)
Citrix HDX Real Time Media Engine
2.0.0.417
Dell Wyse 7040 Thin Client with Windows Embedded Standard 7P Release Notes
Page 17 of 22
Windows Media Player
12.0.7601.18741
Internet Explorer
11.0.9600.17420
Power Term Interconnect
10.2.0.0.20140813.1
Ericom PowerTerm WebConnect
5.8.0.0
VMware Horizon View Client
3.5.2-30397
vWorkspace Connector for windows
8.6.309.4062
Configuration Manager Client
5.00.7958.1000
Adobe Flash player - ActiveX Adobe Flash player - Plugin
20.0.0.270
Tight VNC
2.6.4.0
Microsoft Lync VDI 2013
20.0.0.267 15.0.4420.1017
.NET Framework
4.6.01055
WSUS
Supported
WCM
1.4.0.3
Microsoft Management Console
Management Console 3.0
Microsoft Silverlight
5.1.30514.0
Bit locker with TPM
Version 6.1 (Build 7601: SP1) Supported
Windows Multi-touch
Supported
Background Intelligent Transfer Service
Supported
Windows Defender Definition (BITS)
1.217.282.0 dated 3/31/2016
MSXML
Supported
XML Paper Specification (XPS)
Supported
Dell Wyse 7040 Thin Client with Windows Embedded Standard 7P Release Notes
Page 18 of 22
Network Access Protection
Supported
Credential Roaming
Supported
WPA2
Supported
CredSSP
Supported
ConfigMgr 2012 SP1 Client
Supported
Registry Filter
Supported
Windows Time Service
Supported
DirectX
11
File-based write filter manager –
1.0.299.0
Ntoskrnl.exe fbwfmgr.exe
6.1.7601.18741
ArchiveInfo.exe
1.0.0.4
ClientInformation.exe
10.0.0.8
Disk_Size.exe
3.0.0.5
CAD MAP Tool DWKbFilter.sys DWKbFilterMon.exe DWKbFilterWatchdog.exe
2.2.0.0
FBWF Service – FBWFSvc.exe
1.0.2.2
FBWF System Tray UI - FBWFTray.exe
1.0.2.2
Hagent.exe
6.3.5.16
HAgent_UI.exe
1.0.2.26
NetXClean.exe
3.0.0.7
NumLock_Toggle.exe
1.0.0.4
2.2.0.4 2.2.0.4
Dell Wyse 7040 Thin Client with Windows Embedded Standard 7P Release Notes
Page 19 of 22
Registry Filter
Supported
Windows Time Service
Supported
NumLockTrigger.exe
1.0.0.5
PnPApp.exe
1.0.0.14
TimeZonePreservation.exe
1.0.0.4
WDM.exe
1.0.3.7
Wfacss.exe
1.0.1.3
LicMgrTool.exe
1.0.0.1
WindowsEmbeddedTest.exe (equivalent to WES7Test.exe)
Not Applicable
Winlog.exe
Part of Client Info
Winterm.dll
2.0.0.9
Xwfile.exe
1.0.0.5
Sysprep4man scripts
Build_Master.cmd
QFEs Added in the Release Security Updates KB2479943
KB2893294
KB3011780
KB2852386
KB2506212
KB2894844
KB3019215
KB2853952
KB2509553
KB2898785
KB3021674
KB2857650
KB2511455
KB2900986
KB3022777
KB2859502
KB2536275
KB2909210
KB3023215
KB2868116
KB2544893
KB2909921
KB3025390
KB2882822
KB2556532
KB2911501
KB3030377
KB2888049
Dell Wyse 7040 Thin Client with Windows Embedded Standard 7P Release Notes
Page 20 of 22
KB2560656
KB2925418
KB3032655
KB2891804
KB2564958
KB2929437
KB3033889
KB2893519
KB2579686
KB2931356
KB3033929
KB2908783
KB2585542
KB2936068
KB3034196
KB2913431
KB2604115
KB2937610
KB3035126
KB2913751
KB2619339
KB2943357
KB3035131
KB2918077
KB2620704
KB2953522
KB3035132
KB2919469
KB2621440
KB2957189
KB3037574
KB2928562
KB2631813
KB2957509
KB3042553
KB2929733
KB2644615
KB2957689
KB3045685
KB2970228
KB2654428
KB2961072
KB2841134
KB2980245
KB2667402
KB2961851
KB2670838
KB2985461
KB2676562
KB2962872
KB2830477
KB3006121
KB2690533
KB2963950
KB2592687
KB3006625
KB2698365
KB2963952
KB2819745
KB3014406
KB2705219
KB2965788
KB2487305
KB3020338
KB2706045
KB2968294
KB2492386
KB3021917
KB2709715
KB2972100
KB2515325
KB3040272
KB2712808
KB2972211
KB2534366
KB3054476
KB2716513
KB2972280
KB2545698
KB3075249
KB2719033
KB2973112
KB2547666
KB3075851
KB2724197
KB2973201
KB2552343
KB3077715
KB2727528
KB2973351
KB2563227
KB3078667
KB2736422
KB2976627
KB2574819
KB3083324
KB2742599
KB2976897
KB2598845
KB3092627
Dell Wyse 7040 Thin Client with Windows Embedded Standard 7P Release Notes
Page 21 of 22
KB2770660
KB2977292
KB2640148
KB976902
KB2799494
KB2977629
KB2660075
KB2654644
KB2803821
KB2978120
KB2661254
KB2654644
KB2807986
KB2978742
KB2685747
KB2813170
KB2979570
KB2685811
KB2496898
KB2813347
KB2984972
KB2685813
KB2502664
KB2813430
KB2987107
KB2709981
KB2526967
KB2839894
KB2992611
KB2718704
KB2570814
KB2840631
KB3000483
KB2719857
KB2612905
KB2847927
KB3003057
KB2726535
KB2639308
KB2861698
KB3003743
KB2729094
KB2647753
KB2862152
KB3004361
KB2732487
KB2679255
KB2862335
KB3005607
KB2750841
KB2847077
KB2862973
KB3010788
KB2761217
KB2872035
KB2864202
KB2809215
KB2763523
KB3006137
KB2868038
KB2818604
KB2786081
KB3009736
KB2871997
KB2820331
KB2791765
KB3014793
KB2884256
KB2834140
KB2799926
KB947821
KB2887069
KB2843630
KB280f0095
KB2892074
KB2808679
KB976932
KB3059317
KB3057154
Hotfixes
© 2016 Dell Inc. This manual and the software and firmware described in it are copyrighted. You may not reproduce, transmit, transcribe, store in a retrieval system, or translate into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, any part of this publication without express written permission.
Dell Wyse 7040 Thin Client with Windows Embedded Standard 7P Release Notes