Preview only show first 10 pages with watermark. For full document please download

Delta Word Template - Delta Power Solutions

   EMBED


Share

Transcript

DPR 1000 EnergE Single Phase Rectifier Descriptions The DC power supply consist of (1) rectifier for outdoor stand along communication system, (2) Mounting kit for wall mount or pole mount, (3) Two sets of DC cable. The rectifier requires a nominal input of 100VAC - 240VAC and provides an output of -54 VDC to power the load of communication equipment. Main features  For next generation 4G LTE small cell networks  OPEX energy savings - high efficiency up to 96.0%  1000W – 48V integrated enclosure  Natural convection cooling  Light and compact size  Wall mount or pole mount design  Operating temperature from -40℃ to 46℃  IP65 protection class  NEBS GR-63 Zone4, Earthquake compliance  Optional battery back-up cabinet enhanced surge protection and DC output distribution Applications  LTE/4G/5G  Fixed line  Datacom DPR 1000 EnergE Single Phase Rectifier Technical specifications Model DPR 1000B-48 ID:A1 1. Input Mains voltage 100 - 240 VRMS 1Ø 3W Mains frequency 50 / 60 Hz Power factor >0.99 Finish Connecter  AC input  DC output  Alarm Powder coating Amphenol PWC03RMMS-LC7002 x 1 Amphenol PWC03RMFS-LC7002 x 2 Amphenol CD-09RMFSLC7001 x 1 2. Output Nominal system voltage 54.0 VDC Operating voltage range 42.0 – 58.0 VDC Power limitation 600W@100VAC; 650W@110VAC 1000W@200VAC; 1000W@230VAC; Current limitation 12.5A@100VAC; 13.5A@110VAC; 20.8A@200VAC; 20.8A@230VAC; Over voltage protection 59.0 V Load sharing Yes Protection Internal fuse 3. General Communication Interface 94.0% @100VAC ; 96.0%@230VAC CAN bus User interface Status indication Cooling Natural Cooling 209.8 x 360.0 x 88.8 mm (8.3 x 14.1 x 3.5 inch) 6.4 kg (14.1 lb) -40°C to +46 °C (-40°F to +114 °F) (GR-487) 95%, non-condensing (Max.) Lamppost, pole or wall mountable Peak efficiency Dimensions (W x H x D) Weight Operating temperature Relative humidity Mount Construction Aluminium DELTA ELECTRONICS, INC. 3 Tungyuan Road, Chungli Industrial Zone, Taoyuan City 32063, Taiwan. TEL : +886-3-452-6107 FAX : +886-3-452-7314 Fact_sheet_DPR_1000B-48_IDA1_en_rev0404 http://www.deltaww.com 4. Standards Environment CE, TUV, TUV S mark, UL 60950,NEBS GR1089, JET EN55022, CISPR22, FCC 15 class B RoHS compliant Protection class IP65 (EN 60529) 5. Ordering Information Part number ESR-48/20C S-S Safety EMC *All specifications are subject to change without prior notice.