Transcript
Deluxe Electronic Multi-Function Body Analyzer Body Weight Scale Instruction Manual
Model No.: PEVX-6628
Important: This scale-analyzer will provide body fat – water – muscle - bone weight - calorie readings for a majority of people, but it is not made for use by the following groups: Pregnant women/Persons under the age of 18 years (cannot provide exact body fat readings). BIA (Bioelectrical Impedance Analysis) mode determines your body fat proportion by transferring a harmless signal all the way through your body. Do not use this scale if you have a pacemaker or other internal medical device. When in hesitation, consult with your physician.
IMPORTANT SAFETY INSTRUCTIONS: When using this Body Fat Analyzer/Scale, basic precautions should always be observed, including the following. 1. User must read and understand instructions prior to using this product. Use as described in this manual. Use manufacturer’s original accessories and attachments ONLY. 2. Do not use the Body Fat Analyzer/Scale on Carpet or Rug. 3. Always put the Body Fat Analyzer/Scale on the exact same smooth and hard floor/surface to ensure accuracy of analyser and weight readings. Putting the scale on a smooth, even and hard floor/surface will provide consistency and precise accuracy. 4. Step on the section of the glass platform with metal bar support with 1” distant from edge only. 5. Be very careful! The scale may tilt when you step on it. You should lightly place your left foot or right foot on the metal bar supported section, with at least a distant of 1” from the edge of the glass platform. Once the position is secured and safe, place your other foot onto the scale. 6. Be very careful! Set your left foot on the two metal contact plates on the left supporting metal bar. Your right foot must be placed on the two metal contact plates of the right metal bar with at least a distant of 1” inch from the edge of the glass platform. 7. For your safety. Please centre your body weight toward the mid section of the scale before stepping on / off the scale. Otherwise, the scale may tilt. Personal Injury Risk! 8. Watch your steps and use extra care while using the scale. 9. Follow all label and marking instructions on your scale. 10. To reduce the risk of electric shock, do not use the scale outdoors. 11. Do not use in area where dangerous items are stored. 12. Do not continue to use this scale if it appears to be malfunctioned. 13. Do not use this scale if it appears to be uneven, or quaking, while you are on the scale. 14. Do not use this scale if cracks or chips appeared on the glass platform of the scale. Personal Injury Risk! 15. If unit is not working as it should, has been damaged, dropped, left out-door, or dropped into water, bring it to a licensed electrician or shop for service and repair. 16. Do not disassemble the scale. There are no serviceable parts inside the scale. 17. Always bring the damaged appliance to a licensed electrician or shop for service and repair. 18. Never jump on, or jump off the scale. Personal Injury Risk! 19. Observe the battery precautions and battery disposal instructions listed in this manual 20. Do not remove the batteries from the scale. Other than replacing the batteries, or storing your scale for a long time. The batteries are small parts, and they are extremely danger for children to swallow. Personal Injury Risk! 21. This scale is not a toy. Do not let children to operate or play with the scale. Please keep it away from children. 22. Do not use this scale if you have a pacemaker or other internal medical device. When in hesitation, consult with your physician.
(SAVE THESE INSTRUCTIONS) Page: 1
Know your Model PEVX-6628 (Section I) d=100g / d=0.2lb
Max. 150 Kgs / 330lbs
Body Function analyzer / Body weight Scale Exploded View Diagram (Fig. 1)
1. Set Button 2. Key 3. Key 4. Glass Platform 5. Metal Stripe
6. 7. 8. 9. 10.
L.C. Display Metal Frame Sensors & Non Skip Stoppers Battery Chamber Cover Plastic Frame
Page: 2
(Section II) How to Select (lb / in) or (kg / cm) or (st)
Fig. A-2
Fig. A-1
Tap the glass platform once to turn on the scale, And then 0.0 will appear on the L.C. Display. 8888 will appear on L.C. Display Press the Key or Key to select (lb / in) or (kg / cm) or (st) FINISHED
(Section III) How to use the Body Weight Scale (weight only) :IMPORTANT*****IT IS NOT NECESSARY TO INPUT USER DATA INTO THE SCALE WHEN USING BODY WEIGHT MEASUREMENT ONLY. (Example: turn switch to kg / cm for the test run) A. Place the Body Fat Scale on a smooth, firm, flat surface to body weight accuracy. B.
a. b.
Tap your foot on the Glass Platform once to turn on the scale. 8888 will come on the L.C.D. Display (see Fig. 2)
c.
(Fig. 2) It follows with 0.0 kg on the L.C.D. Display (Fig. 3)
(Fig. 3) d. Carefully step onto the Glass Platform at once and stand still, while the 0.0 kg” is showing on the L.C.D. Display. Your body weight reading will appear on the L.C.D. Display (example 65.0 kg) (see Fig. 4).
C.
(Fig. 4) e. Once the Flashing reading of your weight on the L.C. Display is stopped flashing , the weighing of your body is completed. The body weighting procedure is completed. Please step down from the scale carefully. The scale will shut off in seconds by itself after each use (FINISHED)
Page: 3
(Section IV) Body Fat Analyzer Function. (Before First Use) Inputting the user Information into the Body Fat Analyzer/Scale. It is a MUST for you to follow the following steps to CHOOSE A USER SETTING (user P0 thru user P9), and INPUT YOUR GENDER, HEIGHT and AGE. Important: A total of 10 different user settings (user P0 ~ user P9) is equipped with this Body Fat Analyzer/Scale. You must input the User information into the Body Fat Analyzer/Scale before using the Body Fat function. However, It is not necessary to input the USER DATA into the Body Fat Analyzer/scale, when using for BODY WEIGHT measurement only.
Select User: (10 different users [user P0 ~ user P9] settings for you to choose from)
(Fig. 5)
How to INPUT user data into PEVX-6628. 1. 2.
Select (lb / in) or (kg / cm) or (st) (see Section II) Tap your foot on the Glass Platform once to turn on the scale. 8888 kg will come on the L.C.D. Display (see Fig. 6)
(Fig. 6) 3.
Follows with 0.0 kg on the L.C.D. Display (see Fig. 7)
4.
(Fig. 7) Press the set button once to activate Flashing USER P0 ~ USER P9, while the 0.0 kg” is showing on the L.C. Display. (see Fig. 8).
(Fig. 8)
Page: 4
5.
Press Key or Key to select user setting from User P0 ~ User P9. Press Set Button to confirm user selection. (Example: we will choose and confirm User P4 for this test run) The figurine on top of P4 will start blinking, once User P4 is confirmed, (see Fig. 9)
(Fig 9) 6.
Key or Key to select Gender. Press Set Button to confirm your selection of Press Male or Female. The age reading will start blinking, once Gender is confirmed, (see Fig. 10)
(Fig. 10) 7.
Press Key or Key to select Gender. Press Set Button to confirm your selection of Male or Female. The Height will start blinking, once the Age is confirmed, (see Fig. 11)
(Fig. 11) 8.
Press Key or Key to select your Height. Press Set Button to confirm your Height. Once your Height is confirmed, the following two screens will appear on the L.C. Display in sequence indicating that the USER INPUT is now completed. (see Fig. 12)
(Fig. 12-1) 9.
(Fig. 12-2)
The scale will shut off in seconds by itself after User Data Input (FINISHED)
Important:
User needs to input user personal data into the scale for one time only.
When inputting user data into the scale, the unit will shut off by itself, if it is idled for 15 seconds. If it does, you will have to re-enter the data from the beginning again. Using the Body Weight Function– No data is needed to input into the scale.
Using the Body Fat Function - User MUST select a user setting from user P0 thru user P9 and then INPUT USER DATA into scale before USING it.
Page: 5
(Section V) How to use the body fat function to check your body fat, body water, muscle, bone weight and body weight. USE “user P4” to try out the following steps: 1. Select (lb / in) or (kg / cm) or (st) (see Section II) 2. User needs to input user personal data into the scale for one time (First time) only (see 3. 4. 5. 6.
Section IV). Check Batteries (see Section VI). Place the scale on a hard and smooth floor. (Not to use the scale on top of carpets or rugs). Shoes and socks off Tap your foot on the Glass Platform once to turn on the scale. 8888 kg will come on the L.C.D. Display (see Fig. 13)
(Fig. 13) 7.
It follows with 0.0 kg on the L.C.D. Display (Fig. 14)
(Fig. 14) 8.
Press the set button once to activate Flashing USER P0 ~ USER P9, while the 0.0 kg” is showing on the L.C. Display. (see Fig. 15)
(Fig. 15) 9.
Press Key or Key to select user setting from User P0 ~ User P9. (Example: choose user P4). DO NOT PRESS THE SET BUTTON. (see Fig. 16)
(Fig. 16) 10. User P4 will continue to flash on the L.C. Display for a few seconds, and then follows with the following two screens in sequence, indicating that the Body Fat Function is now ready to use.
(Fig. 17-1)
Page: 6
(Fig. 17)-2
How to use Body Fat Function (continue): 11. Step onto the glass platform carefully and STAND STILL, while 0.0 kg (see Fig. 7) is showing on the L.C. Display (see Fig. 18)
Important: Be careful, when you step onto the glass platform. Place your left foot on the left metal contact plate. Place your right foot on the right metal contact plate. Stand still for the readings. You MUST read the instruction manual very carefully before using the Body Fat Analyzer / Scale.
(Fig. 18) 12. Keep STANDING STILL on the glass platform, and your body weight will appear on the L.C. Display. (see Fig. 19)
(Fig. 19) 13. Keep STANDING STILL on the glass platform and the following displays will appear on the L.C. Display in sequence, indicating that the scale is now measuring your body. (see Fig. 20)
(Fig. 20) 14. Keep STANDING STILL on the glass platform and the Body Fat reading will appear on the L.C. Display (see Fig. 21).
(Fig. 21)
Page: 7
How to use Body Fat Function (continue): 15. Keep STANDING STILL on the glass platform and the Body Water reading will appear on the L.C. Display (see Fig. 22).
(Fig. 22) 16. Keep STANDING STILL on the glass platform and the Body Muscle reading will appear on the L.C. Display (see Fig. 23).
(Fig. 23) 17. Keep STANDING STILL on the glass platform and the Bone Weight reading will appear on the L.C. Display (see Fig. 24).
(Fig. 24) 18. Keep STANDING STILL on the glass platform. The readings of the Body Weight, Body Fat, Body Water, Muscle and Bone Weight will appear on the L.C. Display in sequence for THREE TIMES, before it shutting off by itself (see Fig. 25)
(Fig. 25) 19. Finished. Please step off the scale platform carefully.
Page: 8
Note: The unit is built with an automatic shut off system to conserve the energy of the batteries. The Body Fat Scale/Analyzer will shut off by itself, if it is unused for 15 seconds or more.
Monitoring Total Body Water percentage in the body: Water is an important component of the body. Water combines up approx. 51-69% of the total body’s weight. It is there proportionally added in lean tissue compared to fat tissue. Water is a standard for biochemical reactions that normalize body functions. Waste products pass out of body inform of sweat and urine. Water helps to keep body temperature; provides moisture and lubricates body. The level of water in the body changes with the hydration level of the body. Watching the level of body water is necessary for one’s health maintenance. The likely Total Body Water percentage may differ according to your hydration stage. The amount of water you have drunk or how much you have sweated straight away before to the measurement will affect the readings. It is recommended that to avoid fluctuation in hydration level before using the scale. This Electronic Scale uses bioelectrical impedance Analysis, which is one of the most precise ways of measuring body fat, water and muscle. It sends a harmless signal through the fat and muscle in your body. It calculates your personal weight, body fat, body water and muscle almost at the same time. It gives you a more precise reading of your on the whole health and fitness.
Measure Your Body Fat: Watching your body fat is important to your health and fitness. Healthy body levels can help reduce your chances of developing serious health related problems. High blood pressure, high cholesterol, heart disease, diabetes, and cancer, to name a few are no fun to deal with. Body fat is also a main factor in athletic performance. It used to be, you would have to see a medical or professional to obtain information of your body fat. Now, with the DREAMLIFE’S body Fat Analyzer and Scale, simply enter your personal data and step onto the scale to obtain the readings by you. Note: This Electronic Scale should be used in a consistent manner for the precise reading of your body fat, body water, muscle and weight. The readings may vary between this analyzer and
other methods of measurement. The changing in body fat percentage shown by this Electronic Scale will be reflected precisely. Drinking coffee, beer, wine, alcohol, and taking diuretic medications or workouts. These all affect your level of hydration and the accuracy of this analyzer. Please wait a few hours before taking a body fat reading
Important: Err 2 (Error): “Err 2” on LCD Display - the scale will be turned off automatically. It indicates the incorrect use of this scale. Please read the operating sections in this manual carefully.
Page: 9
(Section VI) Battery Installation: See Exploded View Diagram (Section I) – Item No.: 9 (Battery Chamber Cover) The Electronic Scale uses 2 X 3-Volt Lithium (CR 2032) Cells.
Place 2 X 3-Volt Lithium Replace Battery Cells into the battery snap Cover gently.
Compartment Finished (Fig. 26)
Remarks: 1. Replace the battery when “Low Battery Warning“ is displayed. 2. Remove the batteries if the product is to be stored for a long time.
Battery Removal:
Push and Lift Cover Gently
Pry out the batteries with a Batteries are removed screw driver gently. (Fig. 27)
Battery disposal: DO NOT DISPOSE OF BATTERIES IN FIRE. BATTERIES MAY EPLODE OR LEAK” Warning: “Do not Mix Old and New Batteries. Do not Mix Alkaline, Standard (Carbon-Zinc.) or Rechargeable (Nickel Cadmium) Batteries.” When trashing the batteries - The batteries must be separated from the regular household trash. Please consult with your local authorities for batteries disposal instructions.
Battery – First-Aid: Battery may leaks in extreme weather and conditions. If leaks get on skin and eyes, flush area with cold water and seek medical attention immediately.
Page: 10
Suggestion of Body Fat Levels: Age in Years
19-28 yrs.
29-38 yrs.
39-48 yrs.
49-58 yrs
59 plus
Men
14%
15%
17%
18%
19%
Women
19%
20%
21%
22%
23%
** American College of Sports Medicine
1.
The percentage total body water of an individual differs according to age and gender. The table as follows may be used as a suggestion.
Male
Female
Age
Fat
Water
Age
Fat
Water
19-28
8-20%
59
19-28
19-29%
49%
29-38
10-21%
29-38
21-31%
39-48
12-22%
39-48
23-33%
49-58
14-24%
49-58
25-35%
59-70
16-28%
59-70
27-37%
54 49
48% 44%
2.
Do measure body fat, body water, or weigh at the same time each day.
3.
It is recommended to use the scale without clothing for accurate readings. Clothes can affect the percentage calculation. Bare, clean and slightly damp feet when used to result accurate readings (Be-careful – slippery glass platform).
4.
Hydration Level This electronic scale computes your weight, the electrical impedance of your body, and adds those readings with the data of your input (Age, Height, Gender,). The scale will calculate your body fat percentage accurately. The ideal time for use of this scale is in the evening. Female will have more difference in water content then male and require watching their reading over a longer period of time to set up a personal average. You must consider this as a reference only before calculating progress in a health program. The stage of hydration differs throughout the day and affects the impedance calculating. If a person is dehydrated, there is a good chance for difference in the body fat percentage displayed by this electronic scale than when the person is fully hydrated.
Important (When using the Body Fat Analyzer/Scale):
Place the unit on the same hard, smooth and flat surface for better performance. Clean your feet with a clean slightly dampened cloth. Do not put this product under direct sunlight or in high temperature or in high humidity for a long period of time.
Do not put anything on top of the scale, as it will turn on the unit and deplete the batteries.
Clean the glass platform and the 2 metal contact stripes with a lightly dampened cloth
Page: 11
Errors Indicator: Err2: If body fat ratio, water ratio muscle ratio exceeds the range of display because of incorrect operation, “Err” will be shown and the scale will be turned off automatically.
0-Ld: Overloading: The maximum weight is 150.9kg. See below display. LO: Low voltage alert. If the battery is low on power (about 4.8V), the icon of battery will be shown and please change the battery immediately.
ERR: As inner code is too low or too high by the reason that the load cell has been damaged, the scale will displays ERR. Defective – a replacement is needed.
Specifications: Bioelectrical Impedance Analysis to check body fat and total body water percentage. Weight capacity: 330lbs or 150kg
Weight Graduation: 0.2lb or 100g Body Fat Graduation: 0.2% (in the range from approx. 3% -55%)
Body water Graduation: 0.2% (in the range from approx. 25-75%) Muscle Graduation 0.2% (in the range from approx. 25-65%) Height Range: 3’3” – 7’2” (approx. 100.0 – 220.0cm)
Age range: 10-80 years Measures weight, body fat, and body water simultaneously Weight-only feature with automatic step on Can be use for up to 12 individuals
User selectable units of measure (lb/in) or (kg/cm) or (st) Lower battery indicator Operates on one 2 X 3-Volt (CR2032) Lithium button cells.
Precautions 1. OVERLOAD WARNING: remove weight immediately when the scale displays Err. Otherwise, permanent damage to the scale will occur. 2. 3.
This Electronic Body Fat Analyzer/Scale is made for normal home use only; it is not designed for use in commercial or medical fields. Clean after use with a damp cloth only. Do not use chemical cleaning agents or immerse the
4.
unit into water. Do not let your Analyzer/Scale to turn into saturated with water as it may damage the electronic components. It is a precision electronic product. Please handle with care.
Page: 12