Preview only show first 10 pages with watermark. For full document please download

Demon Tempest Pressure Washers Operator Manual

   EMBED


Share

Transcript

DEMON TEMPEST PRESSURE WASHERS OPERATOR MANUAL Clemas & Co. Unit 5 Ashchurch Business Centre, Alexandra Way, Tewkesbury, Gloucestershire, GL20 8NB. Tel: 01684 850777 Fax: 01684 850707 Web: www.clemas.co.uk Email: [email protected] Technical Specifications Tempest 1 Pump Pump pressure Flow rate Max by-pass setting Min pressure setting 100 bar 111pm 110 bar 50 bar H.P nozzle Motor power Pump oil Unloader valve 15045 2.2KW 10W40 MM4B XT11.14 Boiler 1500psi Fuel type 2.45gpm Pressure 1650psi Nozzle 750psi Nozzle make Electrode gap Ignition Transformer Fuel pump Fan motor Fuses Kerosene/gas oil/derv 7 bar 100psi 1.5 US galls Monarch 60°R or AR Danfoss 60° S 6mm ± 1mm 70 Watts 50 Watts 75 Watts 1 amp semi delay 20mm glass Tempest 2 Pump Pump pressure Flow rate Max by-pass setting Min pressure setting 120 bar 111pm 130 bar 50 bar H.P nozzle Motor power Pump oil Unloader valve 1504 2.2KW 10W40 MM4B XT11.14 Boiler 1750psi Fuel type 2.45gpm Pressure 1900psi Nozzle 750psi Nozzle make Electrode gap Ignition Transformer Fuel pump Fan motor Fuses Kerosene/gas oil/derv 7 bar 100psi 1.5 US galls Monarch 60°R or AR Danfoss 60° S 6mm ± 1mm 70 Watts 50 Watts 75 Watts 1 amp semi delay 20mm glass Tempest 3 Pump Pump pressure Flow rate Max by-pass setting Min pressure setting 110 bar 91pm 120 bar 50 bar H.P nozzle Motor power Pump oil Unloader valve 1504 1.8KW 10W40 MM4B RK9.14 1600psi 2.45gpm 1750psi 750psi Demon Tempest Manual - Issue 12/01 Boiler Fuel type Pressure Nozzle Nozzle make Electrode gap Ignition Transformer Fuel pump Fan motor Fuses page 2 Kerosene/gas oil/derv 7 bar 100psi 1.5 US galls Monarch 60°R or AR Danfoss 60° S 6mm ± 1mm 70 Watts 50 Watts 75 Watts 3 amp semi delay 20mm glass Tempest 4 Pump Pump pressure Flow rate Max by-pass setting Min pressure setting 170 bar 131pm 170 bar 50 bar H.P nozzle Motor power Pump oil Unloader valve 15045 4.0KW 10W40 GM3B RK13.17 Boiler 2500psi Fuel type 2.8gpm Pressure 2500psi Nozzle 750psi Nozzle make Demon Tempest Manual - Issue 12/01 Electrode gap Ignition Transformer Fuel pump Fan motor Fuses page 3 Kerosene/gas oil/derv 7 bar 100psi 1.5 US galls Monarch 60°R or AR Danfoss 60° S 6mm ± 1mm 70 Watts 50 Watts 75 Watts 1 amp semi delay 20mm glass FAULT FIN D ER FALUT M achine s tops s udde nly or will not s tart. CAUSE R EM ED Y Che ck mains powe r powe r, ove rload 13 amp fus e and 1 or 3 amp control fus e s Blown fus e . Burs t D is k failure . Che ck wate r s upply. Che ck che mical drum, clos e valve . R e place dis k. Low pre s s ure . H.P nozzle worn or unloade r s e t incorre ctly. R e place H.P nozzle . R e s e t unloade r valve . Low pre s s ure with nois e and vibration Valve s worn or blocke d. Cle an/re place as re qiure d. R e place . Che ck wate r s upply pipe and unions . Sudde n pre s s ure los s . N o wate r. N o che mical. Pis ton s e als worn. Pump s ucking air. Pump will not by-pas s . N on re turn valve dirty or jamme d. Cle an or re place . Wate r drips from pump box. Pump s e als worn. R e place . Oil drips from pump bottom. Oil s e al worn. R e place . Burne r will not ignite . Fue l tank e mpty. Fue l filte r blocke d. Fue l nozzle blocke d. Ele ctrode s dirty or out of adjus tme nt. Flow s witch out of adjus tme nt. R e fil. R e place . cle an or re place . cle an, re place or adjus t. Wate r igre s s through oil filte r plug. R e place oil. Oil is milky in colour. Adjus t. IF IN DOUBT ASK - OUR ADVICE IS FREE AND CAN SAVE YOU MONEY Demon Tempest Manual - Issue 12/01 page 4 MINIMUM SERVICE SCHEDULES DAILY CHECK THE FOLLOWING a. b. c. d. e. Oil level - top up as reqiured. Fuel tank - top up as reqiured. All hose unions for leaks- replace O rings if leaking. Hose condition - cuts etc. Electrical led and plug - damaged etc. EVERY 500 HOURS OR SIX MONTHS (WHICHEVER COMES FIRST) a. b. c. d. e. f. g. h. Drain and replace pump oil. Drain and refil fuel tank. Cleanand reset electrodes. Replace fuel filter. Clean water filter. Replace high pressure nozzle. Replace fuel nozzle. Descale water system. (hard water areas only) EVERY 1000 HOURS OR 12 MONTHS (WHICHEVER COMES FIRST) a. b. c. d. e. f. g. h. i. Complete 500 hour service. Replace pump seals. Replace oil seals. Check float level. Replace chemical pipes. Cheak unloading pressure and safety valve pressure and adjust. Replace fuel nozzle and set fuel pressure. Check flow switch and adjust if necessary. Check electrical connections for tightness. The above service schedules are intended as a guide only. Actual service times and replacement parts reqiured will vary according to the area and usage of the machine. Demon Tempest Manual - Issue 12/01 page 5 PREPARATION a. Connect hose to water inlet connector and turn on. b. Connect high pressure hose to connector. c. Connect lance to hose. d. Connect plug to suitable RCD protected supply nad turn on. e. Top up fuel levels and check oil levels in pump and engine. f. If chemical is to be used place filter in drum of chemical and open valve. If not make sure valve is closed. OPERATION TO START MACHINE a. Push blue switch once to start the engine. b. Pull trigger until operating pressure is reached. c. Push red switch once, burner will then operate. d. Burner will then ignite once trigger is pulled. OPERATION TO STOP MACHINE a. Close the chemical valve if opened. b. Switch to cold by pressing red button once and run the machine until the water turns cold. c. Switch off by pressing blue button once. d. Pull trigger to release excess pressure and disconnect from machine. e. If the machine is to be stored, drain water system and top up the fuel and oil levels. IF IN DOUBT ASK - OUR ADVICE IS FREE Demon Tempest Manual - Issue 12/01 page 6 SAFETY i. Under the terms of the Health & Safety at Work Act and for the operators protection a Residual Current Device (R.C.D) or Earth Leakage Trip MUST be used with this machine. ii Water at high pressure is dangerous and can cause serious injury. This machine is to be used with great caution. a. NEVER point the high pressure spray jet at any person, animal, glass or any other material which may shatter. b. PREVENT any over-spray from injuring other people or damaging property. c. DO NOT even try to use a pressure washer on machinery or electrical equipment that is connected in any way to the manis supply. (all switches in the off position, pull out all plugs and if possible remove fuses). Cover or seal electric motors and fittings to prevent entry of water. d. ALWAYS when using machine:- wear safety goggles and helment or helment with a visor. - wear waterproof clothing and gloves. - take particular care with detergents and chemicals. e. NEVER attempt to disconnect any hose with pressure in it or allow the hose to be flattened or kinked. f. DO NOT use a high pressure hose from a ladder. Use a platform tower or proper scaffolding. g. CHECK that your supply voltage agrees with that shown on the machine. h. Extentions leads are not recommended for use with this equipment. Fit extention hoses or contactthe service department. i. Where a cable is found to be damaged, the power must be switched off and the plug removed before attempting to remove the equipment. j. ALWAYS disconnect the hoses when the machine is not in operation and protect the machine from frost and cold winds. k. ALWAYS use the machnie in a well ventilated area. CAUTION - if using chemicals some brands will adversely affect the brass components fitted to this machine. If in doubt please telephone our technical department for advice. Demon Tempest Manual - Issue 12/01 page 7 Demon Tempest Manual - Issue 12/01 page 8 Demon Tempest Manual - Issue 12/01 page 9 WARRANTY This warranty covers the cost of all replacement parts and labour charges incurred. It does not cover the cost of transport or carriage. It is the owners responsibility to return the machine to a service depot or pay the travelling expenses of a service engineer to attend. Demon International’s decision in warranty matters is final and binding. Demon International Ltd undertake to repair or replace, any component which may fail due to a manufacturing fault within a period of 12 months from the date of purchase, provided that any fault or damage was not sustained by; A. Lack of regular and proper maintainance, user negligence, misuse, or damage caused by ice and frost. B. The effects of contaminated fuel or water, the use of non-approved chemicals or an in sufficient or unsuitable electrical supply. C. The effects of un-authorised modification and use. D. Compression damage to high pressure hose.(HOSES WARRANTED FOR 1 MONTH ONLY) E. Worn out items considered fair wear and tear. Parts which may or may not wear out during the first year and which are considered service items which will need replacing from time to time: High pressure nozzle, lance, trigger, hoses, fuel nozzle, fuel filter, piston seals, valves, unloader seats and seals, water filter, non-return valve, chemical barbs, chemical pipes and pump oil seals. It is the owners responsibility to ensure the Pressure Washer is kept in a safe and suitable environment and any faults reported by operatives to be rectified at the earliest possible date. It is the operators responsibility to check the Pressure Washer for any faults and report them immediately. The Pressure Washer must be used in accordance with the manufacturers specifications and guidelines. Demon International Ltd undertake to use the highest quality components available during manufacture, but cannot be held responsible for any undue consequence arising from the use of there Pressure Washer. This warranty is given to the original purchaser only and is not tranferable without the fully authorised and written consent of Demon International Ltd. Demon Tempest Manual - Issue 12/01 page 10 Warranty Procedure End Users If your machine develops a problem: 1. Phone Demon for advice with the model and serial number to hand. 2. Describe fully the problem as best you can. 3. If the problem cannot be resolved over the phone then the machine can be booked in for repair and if the faults are covered by the warranty the repair will be carried out free of charge. 4. If you cannot bring the machine in for repair then we will despatch an engineer. If the fault is covered by the warranty then we will not charge for labour or spares used, however the transport charge will be payable weather or not the repair is warranty. Hire Centres and Dealers If your machine develops a problem: 1. Phone Demon for advice with the model and serial number to hand. 2. Describe fully the problem. 3. We will advise you on the best course of action, however if parts are required you must raise a purchase order number to cover the parts. When the parts are fitted they must be returned for examination before a credit note is issued. 4. If you are unable to repair the machine then we will despatch an engineer to carry out the repair. We will need a purchase order to cover the cost of transport to and from the site and for parts and labour if the repair is not covered under the warranty. 5. If required Demon will arrange for a carrier to collect a damaged machine, if the warranty claim is valid we will pay this cost, if not it will be charged to the customer. Notes: You will not invalidate the warranty by investigating faults and repairing them yourself providing you follow our advice. Hire Centres and Dealers are expected to carry out all repairs themselves with Demon crediting faulty parts upon receipt and inspection. Spare parts fitted to machines are guaranteed for 1 month only or the remainder of the warranty period whichever is longer. Demon Tempest Manual - Issue 12/01 page 11 Demon Tempest Manual - Issue 12/01 page 12 Demon Tempest Manual - Issue 12/01 page 13 Demon Tempest Manual - Issue 12/01 page 14 Demon Tempest Manual - Issue 12/01 page 15 Demon Tempest Manual - Issue 12/01 page 16 Demon Tempest Manual - Issue 12/01 page 17 Demon Tempest Manual - Issue 12/01 page 18 Demon Tempest Manual - Issue 12/01 page 19 Demon Tempest Manual - Issue 12/01 page 20 Demon Tempest Manual - Issue 12/01 page 21 Demon Tempest Manual - Issue 12/01 page 22 Demon Tempest Manual - Issue 12/01 page 23 Demon Tempest Manual - Issue 12/01 page 24 Demon Tempest Manual - Issue 12/01 page 25 Demon Tempest Manual - Issue 12/01 page 26 Demon Tempest Manual - Issue 12/01 page 27 Demon Tempest Manual - Issue 12/01 page 28 Demon Tempest Manual - Issue 12/01 page 29 Demon Tempest Manual - Issue 12/01 page 30 Demon Tempest Manual - Issue 12/01 page 31 Demon Tempest Manual - Issue 12/01 page 32 Demon Tempest Manual - Issue 12/01 page 33 Demon Tempest Manual - Issue 12/01 page 34 C hem ical& W ater C ircuits No P artN o D escription Q ty 1 M TM 86010 C hem icalFilter 1 2 D E M 20500 H ose C lips 4 3 D E M 10115 C hem icalpipe 2 4 M TM 25801 C hem icalValve 1 5 PA 00100 C hem icalIntake 1 6 M TM 71167 H ose B arb C om plete 1 7 D E M 20500 Jubilee C lip 4 8 D E M 20400 H ose Tail 1 9 H H 0053 InletP ipe 1 10 M TM 85002 W aterFilter 1 11 D E M 10435 W aterTank 1 12 M TM 0012FF03 B rass E lbow 1 13 H H 0053 P ipe 1 14 D E M 10310 H ose Tail 1 15 D E M 10300 H ose Tail 1 16 M TM 0012FF02 B rass E lbow 1 17 D E M 20255 A daptor 1 18 M TM 0012FM 03 B rass E lbow 2 19 D E M 204110 H ose Tail 2 20 M TM 89011B M esh Insert 1 21 M TM 89011 B rass Filter 1 FuelS ystem P artList No P artN o 1 D E M 10410 FuelTank 24 Litres 1 2 D E M 10420 FuelTank C ap 1 3 D E M 20450 FuelP ickup P ipe 1 4 D E M 20430 FuelP ickup A daptor 1 5 D B 002520 FuelP ipe -Tank to Filter 1 6 D E M 20440 InletTail 2 7 D E M 20502 O C lip 4 8 D B 002510 FuelP ipe -Filterto P um p 1 9 D B 002500 FuelFilter 1 Demon Tempest Manual - Issue 12/01 D escription page 35 Q ty Demon Tempest Manual - Issue 12/01 page 36 Demon Tempest Manual - Issue 12/01 page 37 Demon Tempest Manual - Issue 12/01 page 38 AN N OVI PUM PS XT19.14 XT11.14 XT13.12 Ite m Part N umbe r D e s cription 1 AR 680570 He ad Bolts M 6x60 6 2 AR 620301 Bung N ut 1/8" Thre ad 1 7 AR 1260160 Valve Plug 6 8 AR 960160 O R ing for Valve Plug 6 9 AR 1269050 Comple te Valve (AR KIT1864) 6 10 AR 880830 O R ing - XT Valve (AR KIT1864) 6 11 AR 1320340 Support R ing 18mm (AR KIT1874) 3 12 AR 1260220 Se al (AR KIT1874) 3 13 AR 1320351 Pis ton Guide 18mm 3 14 AR 1260420 O R ing for Se al Holde r (AR KIT1874) 3 15 AR 1260450 Pis ton Se al 18mm (AR KIT1874) 3 16 AR 1260460 Oil Se al (AR KIT1872) 3 17 AR 1320320 Bung 1 18 AR 1320360 O R ing (AR KIT1872) 1 19 AR 1260790 Circlip 52mm 1 20 AR 1320370 Crank Be aring 1 21 AR 1320330 Crank Be aring Bus h 1 22 AR 1320010 Pump Body Cas ting 1 23 AR 880130 Oil Plug With D ips tick 1 24 AR 1260110 Pis ton N ut (AR KIT2629) 3 25 AR 1260100 Coppe r Was he r XT Pis ton N ut (AR KIT2629) 3 26 AR 1260210 Pis ton 18mm (AR KIT2629) 3 27 AR 480480 Pis ton O R ing (AR KIT2629) 3 28 AR 1260091 Se pe ration D is k (AR KIT2629) 3 29 AR 1260070 Pis ton Guide 3 30 AR 1260080 Pis ton Pin 3 31 AR 1260760 Bolt M 5x20 6 32 AR 1329010 Comple te Cove r 1 36 AR 1320140 Con R od (Bronze ) 3 37 AR 1260040 Gas ke t (AR KIT1872) 1 38 AR 740290 O R ing 2 39 AR 880530 Bung N ut 1/2" 2 40 AR 1320020 XT Cylinde r He ad (Bras s ) 1 41 AR 180101 O R ing 2 42 AR 820360 Bung N ut 1/2" 1 43 AR 1260180 Cranks haft XT9.14 1 43 AR 1260200 Cranks haft XT11.14 1 43 AR 1320260 Cranks haft XT13.12 1 44 AR 1380520 Ke y 1 45 AR 1320370 Crank Be aring 1 46 AR 1260750 Oil Se al (AR KIT1872) 1 83 AR 1260790 Circlip 52" 1 Demon Tempest Manual - Issue 12/01 page 39 Quantity Demon Tempest Manual - Issue 12/01 page 40 Demon Tempest Manual - Issue 12/01 page 41 Demon Tempest Manual - Issue 12/01 page 42 Demon Tempest Manual - Issue 12/01 page 43 Demon Tempest Manual - Issue 12/01 page 44 Demon Tempest Manual - Issue 12/01 page 45 Demon Tempest Manual - Issue 12/01 page 46 ANNOVI GM 3B UNLOAD ER VALVE Part Numbe r ARGM 3B D e s cription Comple te Unloade r Valve AR1560580 Cap AR1660210 Nut AR1560400 Adjus ting Knob AR1560420 Adjus ting Cap AR1080070 M ini M atic Pin AR1560410 Spring Holde r AR1560440 Spring Cap AR1560350 Spring AR1080610 Spring Plate AR1080660 Pin GM Unloade r AR1540080 Banjo Bolt AR1560010 Valve Body (G) AR1080540 Uppe r Pis ton GM Unloade r AR1560100 Non Re turn Body AR1560140 Spring AR1560490 Che mical Barb AR1250280 Ball AR1560520 Spring AR1560510 Nut AR1560500 Exit Pie ce with Che mical Inje ctor AR1560110 Exit Pie ce 3/8" AR1560111 Exit Pie ce 3/8" AR1560320 By Pas s Pis ton AR880270 O'Ring AR1560050 By Pas s Tube ( Gymatic) AR1540050 Inle t 1/2" BSP AR1540090 Banjo Bolt AR1540020 Low Pre s s ure Hous ing ARKIT2611 Unloade r Valve Kit ( 200 Bar) Demon Tempest Manual - Issue 12/01 page 47