Preview only show first 10 pages with watermark. For full document please download

Devtech Hid Fugen 35w

   EMBED


Share

Transcript

Warehouse/Parking Lot Bridges & Tunnels 91, Alps Avenue, #03-01, Singapore 498787 www.devtechm2m.com 9580 Topanga Canyon Blvd, Chatsworth, CA. 91311 www.mevtechm2m.com IP66 AC 90~305V Input Frequency 50~60Hz Power Factor 0.98 THD 5% Lamp Op. Frequency 147Hz Max Ignition Voltage 4KV~5KV Case Temp (tc) 80 C -40 C...+55 C Ambient Temp (ta) R 3. S UAE A4/45, SAIF Zone, P.O. Box 9562, Sharjah, United Arab Emirates www.devtechm2m.com Devtech M2M Pte. Ltd. INDIA Mines Website : www.devtechm2m.com SAVA House, Off New Airport Road, Viman Nagar, Pune – 411014 India www.devtechm2m.com Hazardous locations IT Campus Commercial Lighting Devtech M2M Ltd. MADE IN INDIA Path way/Road way Industrial Lighting R All product specifications are subject to change without prior notice. Visit our website for updated documents. SINGAPORE Devtech M2M Pte. Ltd. USA Devtech M2M LLC logo and LonWorks R are registered trademarks of Echelon Corporation. Municipal Corporations Parks & Townships R s PLC (110kHz - 140kHz) Rated Voltage Note : Disconnect line voltage before installing or replacing controller Enabling Smart Cities Ballast Input Red Black Yellow/Green Neutral Earth Line Ballast Output Lamp(+) Red Lamp(-) Black High Mast/High Bay Lighting INPUT Surge Guard 1510/1520 OUTPUT DEVTECH FUGEN (HPS/MH/CDM-T) Street Lighting Applications Line Neutral Earth Lamp+ Lamp- Connection Diagram R R 3. S LonMark International Certified Power Line based energy Efficient Electronic Control gear or Ballast of wattage's ranging from 35W to 1000W for driving HID lamp types such as HPS/MH/CMH/CDM-T/CXL lamps with remote monitoring, controlling, dimming, scheduling, alarming, data logging, Energy consumption (kWh), Failure information, Metering information such as voltage, current, active power, Power Factor (PF), Device/Lamp running hours and communicates with segment controller or gateway using bidirectional LonWorks® Power line carrier communication (PLCC) mesh technology. It is provided with all kinds of input and output protections, wide operating input voltage range from 90 to 305VAC, Unity power factor and Total Harmonics (THD) less than 5%. It can be used for all Industrial, Commercial and Street lighting applications. DEVTECH HID FUGEN 35W-1000W Enabling Smart Cities ISO/IEC 14908-1 ISO/IEC 14908-3 LonWorks R ? High Power Factor with value 0.98. ? Low Total Harmonic Distortion (THD) with value 5%. ? Enables remote command and control at each and every lamp. ? Built in metering engine with Class 1 accuracy which captures and Feeder Pillar Authorized users over HTTP or HTTPS Segment Controller/ Gateway Devtech HID Fugen Devtech HID Fugen Secured WAN IP network GSM/GPRS/3G/4G/ Ethernet/Wi-Fi Feeder Pillar HID Luminaires Data Centre Segment Controller/ Gateway Feeder Pillar HID Luminaires Web Application Server Website : www.devtechm2m.com Database Communication Server Access Router Central Server Devtech Segment Controller/ Gateway Unit Devtech HID Fugen level of dimming by PWM current regulation to adjust lighting levels & increase energy saving. ? Wide range of dimming 50 to 100% output power with 1% step dissipation (IP67 / IP68 version also available). ? Aluminium Extrusion IP66 casing with fins for proper heat operation in hostile environments for outdoor and indoor installations. ? Thermal Silicone Potting/encapsulation for trouble free the HID lamp for easy maintenance access. ? Ballast can be located at distance of Maximum 50 meters from All product specifications are subject to change without prior notice. Visit our website for updated documents. End users Segment Controller/ Gateway Devtech HID Fugen HID Luminaires System Architecture ? Comprehensive warranty . ? Compliant to ROHS, CE and LonMark Standards. ? Lightweight and easy to install. ? Quiet , cool operation and Environmentally friendly. down. ? Automatic detection of failures and warnings, reporting and shut reports all the real time energy metering parameters as well as records the historical usage type data such as energy consumption (KWh) and lamp/device running hours. 1.4 Kg 90mm 88mm 180mm 180mm DFG 100W DFG 150W 88mm 1.0 Kg 1.0 Kg DFG 400W DFG 320W DFG 250W DEVTECH HID FUGEN 100W/150W/200W 90mm 90mm DFG 200W 220mm 220mm 220mm 180mm Length (L) 115mm 115mm 115mm 88mm 114mm 114mm 114mm 90mm Width (W) Height (H) 2.6 Kg 2.6 Kg 2.6 Kg 1.4 Kg Nett Weight 80°C 80°C 80°C 80°C 80°C 80°C 80°C 80°C 80°C Website : www.devtechm2m.com DEVTECH HID FUGEN 250W/320W/400W All product specifications are subject to change without prior notice. Visit our website for updated documents. DEVTECH HID FUGEN 35W/50W/70W 1.4 Kg 90mm 88mm 145mm 88mm 1.0 Kg DFG 70W Nett Weight 145mm 90mm DFG 50W 88mm 145mm DFG 35W Width (W) Height (H) Length (L) Product Code Dimensional Data 1.80A Product Code Up to 50 meters 5% 0.98 240VAC DFG 400W 400W 5% Up to 50 meters Up to 50 meters 5% 0.98 0.98 1.12A 1.43A 240VAC DFG 250W DFG 320W 240VAC 200W DFG 200W 320W Up to 50 meters Up to 50 meters 250W 5% 5% 0.98 0.68A 240VAC Up to 50 meters 0.98 150W DFG 150W 5% 0.98 0.458A 240VAC Up to 50 meters Up to 50 meters Up to 50 meters 0.90A 100W DFG 100W 5% 0.98 0.325A 5% 0.98 0.229A 240VAC 240VAC 5% THD 0.98 Power Factor 0.158A 240VAC Input Voltage 240VAC 70W 50W DFG 70W 35W DFG 50W Wattage DFG 35W Product Code Electrical Data Max Cable length to lamp tc point Max IEC 61347-2-11 Safety ? High efficiency beyond 92%. meshing/Repeating. ? Optimizes communications with integrated power line Line Current 13. Fast Transient Lamp Under-Voltage Protection and shutdown 6. High Ballast EN 61547 7. Lamp EOLL (End of lamp life) shutdown 12. Ballast / Lamp failure Protection and Shutdown 5. High Harmonic distortion Cut OFF CISPR 15 Edition 8.0 Immunity LonWorks R Frequency CENELEC C Band (110kHz - 140kHz) Emission maintenance over wide operating range of Universal input Voltages 90 ~ 305VAC, 50 ~ 60Hz. ? Provides constant Power output to HID Lamp with Steady lumen Soft start, Input and Output ballast lamp protection. ? ASIC and Embedded DSP control for proper Ballast operation, schedule and modified due to schedule changes “on the fly”. Type of Protection 11. Lamp Open circuit / Ignition failure Protection and Shutdown i.LON Smart Server located on LT power line network feeder and Intelligent Streetlight control Devtech iStreet.Network software (Standalone/Cloud based server application) for remote monitoring, controlling operations and data acquisition of electrical parameters from off-site location with substantial amount of energy savings and reduced maintenance operating cost. ? Connects directly to ? Light levels can be programmed to synchronize with usage 4. Low Power Factor Cut OFF 9. Ballast/Lamp Operating Hours Standards Protection / Alarm 5. KWh Energy consumption 4. Power Factor 7. Lamp Current 8. Ballast / Lamp Status 6. Lamp Voltage 2. Step Dimming (50 ~ 100% Lamp Power/Brightness) 9. Lamp over voltage protection and Shut down 10. Lamp Short Circuit Protection and Shutdown Max 80°C -40 to +55°C 3. Input Power 1. Ballast Power ON/OFF 1. Supply Voltage 2. Supply Current 8. Lamp undervoltage / Warm up failure protection and Shut down Case Temperature (tc) Ambient Temperature (ta) Monitoring Controlling Devtech HID Fugen Control/Monitor/Protection or Alarm (Using function) Description 2. High/Low Input Current Cut OFF 3. High/Low Input Power Cut OFF Ballast, PF improvement Capacitor and External Ignitor. ? Retrofit one box solution that replaces conventional Magnetic 0.98 5% 147Hz 4 ~ 5kV 50 ~ 60Hz Line Frequency Power Factor THD Lamp Op. Frequency Max. Ignition Voltage AC 90 ~ 305V Technical Data Rated Voltage 1. High/Low Input Voltage Cut OFF or Ballast for HPS/MH/CMH/CDM-T/CXL lamp types and communicates with Segment Controller/Gateway. ? LonWorks R Power line-based energy efficient Electronic Control Gear Key Features Devtech HID Fugen (HPS/MH/CMH/CDM-T/CXL) DFG 35W-1000W