Dh400 Series - Fire-lite

   EMBED


Share

Transcript

June 18, 1998 F-575 DH400 Series 2-Wire Duct Detector Housings for Ionization and Photoelectric Sensors Section: Conventional Initiating Devices GENERAL HVAC systems supply conditioned air to virtually every area of a building. Smoke introduced into an air recirculation system is distributed to occupied areas of a building. The System Sensor DH400 Series Duct Detector Housing is designed to sample air currents passing through a duct, allowing early detection of a developing fire. When sufficient smoke is sensed, an alarm signal is initiated at the fire alarm panel monitoring the detector, and appropriate action can be taken to shut off fans and blowers, change over air handling systems, etc. This can prevent the rapid distribution or isolation of toxic smoke and fire gases throughout the areas served by the duct system. California State Fire Marshal 3240-1209:155 CS308 S911 MEA 427-91-E 0V3A0.AY The System Sensor DH400 duct detector system is easy to install and maintain. NOTE: The System Sensor DH400 Duct Detector Housing is supplied with either the 1451DH Ionization Sensor (DH400I) or the 2451 Photoelectric Sensor (DH400P). FEATURES • • • • • • • • • • • 12/24 VDC operation. Accommodates ionization or photoelectric heads. Simple change-out of detectors heads; twist-in, twist-out. Powered output for remote LED. Air velocity rating from 500 to 4,000 feet (152.4 to 1219.2 meters) per minute. UL 268A listed to two-wire control panels. Clear polycarbonate cover for convenient visual inspection of sampling tube filters. Rugged Noryl® housing (mounting portion). Remote test station option. Easy and quick mounting to round or rectangular ducts from 1' to 12' (0.6 to 3.66 meters) wide. Three-year limited warranty. APPLICATIONS Duct smoke detectors have specific limitations. Duct detectors are: • NOT a substitute for open area smoke detectors. • NOT a substitute for early warning detection. • NOT a replacement for a building’s regular fire detection system. System Sensor duct detector “Applications and Installation Instructions” should be used for reference, as well as “Guide for Proper Use of System Smoke Detectors” (I56407-000). Call Fire•Lite for information. DH400 Series Duct Detector Housing CONSTRUCTION AND INSTALLATION The twist-in, twist-out detector and base allow the removal of detectors easily and quickly for cleaning and maintenance. In addition, detector heads can be changed to fit the application without removing the duct housing. The DH400 comes with built-in exhaust tube. Sampling tubes are available to fit ducts from 1 to 12 feet (0.6 to 3.66 meters) wide. SPECIFICATIONS DIMENSIONS: Width: 14-1/2" (36.83 cm). Height: 5" (12.70 cm). Depth (installed): 4" (10.16 cm). Weight: 4 lbs. (1.814 kg.). OPERATING RANGES: Temperature: 0°C to 49°C (32°F to 120°F). Humidity: 10% to 93% relative humidity. Air duct velocity: 500' (152.4 m) to 4,000' (1219.2 m) per minute. Reset time: 0.3 seconds (maximum). UL listed to 268A. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. Phone: (800) 6273473, Toll Free FAX: (877) 699-4105, FAX Back:(888) 388-3299 WEB: www.firelite.com DF-51096 — Page 1 of 2 ELECTRICAL RATINGS (includes base and detector) System voltage: 12/24 VDC. Maximum ripple voltage: 4 volts peak to peak. Start-up capacitance: 0.02 µF maximum. Standby ratings: 8.5 VDC minimum, 35 VDC maximum, 120 µA maximum. Alarm ratings: 4.2 VDC minimum at 10 mA; 6.6 VDC maximum at 100 mA; alarm current must be limited to 100 mA or less by the control panel. If used, the RA400Z remote lamp operates within the specified alarm currents. PRODUCT LINE INFORMATION Model DH400I 1451DH Replacement ionization smoke detector head. DH400P Duct detector housing with photoelectric smoke detector. 2451 Replacement photoelectric smoke detector head. ST-1.5 Metal sampling tube, duct widths 1' to 2' (see table at left for metric lengths). Metal sampling tube, duct widths 2' to 4'. Metal sampling tube, duct widths 4' to 8'. Metal sampling tube, duct widths 8' to 12'. Remote annunciator alarm LED. Test magnet. Remote test station. Mounts in single-gang box. Includes red alarm LED and magnet test switch (separate 24 VDC/VAC is required). Sensitivity test kit. Ionization cover removal tool. ST-3 Reset voltage: 2.5 VDC minimum. ST-5 Reset time: 0.3 seconds maximum. ST-10 INLET TUBE SELECTION RA400Z M02-04-00 Outside Duct Width Inlet Tube Required* Up to 2 feet (0.6096 m) ST-1.5 2 to 4 feet (0.6096 to 1.2192 m) ST-3 4 to 8 feet (1.2192 to 2.4384 m) ST-5 8 to 10 feet (2.4384 to 3.0480 m) ST-10 Description Duct detector housing with ionization smoke detector. RTS451 MOD400R CRT-400 *NOTE: Inlet tube is required and must be purchased separately. Order one inlet tube for each duct detector housing ordered. The RTS451 Page 2 of 2 — DF-51096 The RA400Z