Diagram 1 - Dimmer Bypass The Dimming Relay Contacts Provide

   EMBED


Share

Transcript

AD7 INVERTER - INTERRUPTIBLE WITH CIRCUIT BREAKER AND DIMMER BYPASS NORMAL LIGHTING LOAD NORMAL CIRCUIT NORMAL AC INPUT (FLYING LEADS) BRANCH CIRCUIT EMERGENCY CIRCUIT WHT (NEU) ORG (277V) ALTERNATE AC INPUT (120V OR 277V) (277V) (277V) WALL SWITCH (IF PRESENT) DESIGNATED EMERGENCY LOAD GRAY (NEUTRAL) VIOLET (120V) YEL/VIO (120/277V) YELLOW (277V) CIRCUIT BREAKER OPERATES IN BOTH NORMAL AND EMERGENCY MODES. CIRCUIT MUST BE ISOLATED FROM NORMAL CIRCUITS. BLU (NORMALLY OPEN) RED (COMMON) ORG (277V) VIOLET BRN (NORMALLY CLOSED) INVERSION BLK (120V) DIMMING RELAY LEADS BATTERY CONVERSION WHT (NEU) DIMMER CONTROL GREEN INVERTER INPUT LEADS GRAY (120V) VIOLET (120V) GRAY BLK (120V) Diagram 1 - Dimmer Bypass The Dimming Relay contacts provide electrical continuity during normal power conditions allowing your dimming signal to operate the luminaire in the desired, dimmed state. When the inverter transfers into the emergency mode, the dimming relay contacts electrically open the 0-10 dimming reference signal forcing the luminaire to operate at full lumen output regardless of dimmer setting. GROUND WIRE PRIMARY UNSWITCHED INPUT AC INPUT FOR THE INVERTER - MUST BE UNSWITCHED. SELECT PROPER VOLTAGE FLYING LEADS ARE FOR THE NORMAL AC INPUT (SWITCHED OR UNSWITCHED) - SELECT PROPER GROUND WIRE - CONNECT FIXTURE SUPPLY GROUND AND UNIT GROUND IN ACCORDANCE WITH LOCAL AND NATIONAL CODES. IF USING A SECONDARY AC INPUT, SELECT PROPER VOLTAGE LEAD AND CAP UNUSED LEAD. USE A 277V RATED SWITCH IF CONNECTING TO 277V INPUT. INVERTER - INTERRUPTIBLE WITH CIRCUIT AND EMERGENCY DIMMING SIGNAL LEAD AND CAP UNUSED LEAD. VOLTAGE BREAKER LEAD AND CAP UNUSED LEAD. NORMAL CIRCUIT EMERGENCY CIRCUIT WHT (NEU) ORG (277V) (277V) (277V) WALL SWITCH (IF PRESENT) GRAY (NEUTRAL) VIOLET (120V) YEL/VIO (120/277V) YELLOW (277V) CIRCUIT BREAKER DESIGNATED EMERGENCY LOAD OPERATES IN BOTH NORMAL AND EMERGENCY MODES. CIRCUIT MUST BE ISOLATED FROM NORMAL CIRCUITS. BLU (NORMALLY OPEN) RED (COMMON) BATTERY CONVERSION DIMMING RELAY LEADS WHT (NEU) DIMMER CONTROL GREEN INVERTER INPUT LEADS GRAY BRN (NORMALLY CLOSED) INVERSION ORG (277V) BLK (120V) VIOLET (120V) VIOLET (120V) GRAY BLK (120V) ALTERNATE AC INPUT (120V OR 277V) NORMAL LIGHTING LOAD IIS_375_550_DR_WITH CIRCUIT BREAKER_1.EPS NORMAL AC INPUT (FLYING LEADS) BRANCH CIRCUIT CIRCUIT BREAKER CONNECTIONS - CONNECT PROPER LOAD VOLTAGE TO CIRCUIT BREAKER AND CAP UNUSED LEAD. GROUND WIRE Diagram 2 - EM Dimming Signal The Dimming Relay contacts are electrically open during normal power conditions allowing your dimming signal to operate the luminaire in the desired, dimmed state. When the inverter transfers into the emergency mode, the dimming relay contacts electrically short the 0-10 dimming reference signal forcing the luminaire to operate at a reduced lumen output setting based on the dimmable driver being used. Verify operating results of the luminaire with the 0-10 volt reference signal shorted to assure the application and mounting height produce code-compliant egress lighting. PRIMARY UNSWITCHED INPUT AC INPUT FOR THE INVERTER - MUST BE UNSWITCHED. SELECT PROPER VOLTAGE LEAD AND CAP UNUSED LEAD. FLYING LEADS ARE FOR THE NORMAL AC INPUT (SWITCHED OR UNSWITCHED) - SELECT PROPER VOLTAGE LEAD AND CAP UNUSED LEAD. GROUND WIRE - CONNECT FIXTURE SUPPLY GROUND AND UNIT GROUND IN ACCORDANCE WITH LOCAL AND NATIONAL CODES. IF USING A SECONDARY AC INPUT, SELECT PROPER VOLTAGE LEAD AND CAP UNUSED LEAD. USE A 277V RATED SWITCH IF CONNECTING TO 277V INPUT. CIRCUIT BREAKER CONNECTIONS - CONNECT PROPER LOAD VOLTAGE TO CIRCUIT BREAKER AND CAP UNUSED LEAD. IIS_375_550_DR_WITH CIRCUIT BREAKER_2.EPS PHONE (520)-294-3292 FAX (520) 741-2837 WEB www.iotaengineering.com