Preview only show first 10 pages with watermark. For full document please download

Diagram 6 3 4

   EMBED


Share

Transcript

Orange Brown Black Black Out. Fan Relay 65 3 Blue Red Black 1 3 Yout 55 1 Low Ambient Control (Opt.) 15 Black 6 12 62 Red Black 70 C 12 Blue Y 40 Blue B O1 W1 Purple 51 35 Y1 30 40 L DH Transformer R Low Pressure Bypass Low Pressure Control L1 L2 L3 Y Yo C Phase Monitor Red 44 45 L1 L2 COM 3 NC C Defrost Control R 2 Defrost CC Control LOR-1 L0 Lockout Relay Control LI High Pressure Control #1 Defrost Sensor Y L L B B W2 W2 SENSOR LOR-2 DFC-1 DFC-2 Y1 7 Black 63 Fuse Block 61 Red Out. Fan Relay C 1 LAB 2 RV Reversing Valve C High Speed Solenoid NC AC SW L3 Ground Lug 29 G High Pressure Control #2 W3 8 Yellow 62 Fuses Black Compressor Contactor 24VAC 1 2 35 Capacitor Black Yellow A Low Ambient Control AC Red Transformer Black Current Sensor Yellow Brown Crankcase Heater Bypass Relay 2 4 Terminal Block 24 DELAY ON BREAK R E Red 18 20 22 16 24 14 26 12 28 10 30 W3 24 VAC G 18 20 25 W2 Low Voltage Term. Block 5 C 15 C 10 Black (High Spd) Pink Ground A C Current Sensor HPS 41 Transformer 16 52 CURRENT TRIP SETPOINT High Speed Solenoid NC Outdoor Fan Motor Capacitor L3 Disch. Line Tstat Y COM Black NO NC COM 33 480V 53 T1 T2 T3 46 12 AWG WIRE Crankcase Heater Outdoor Fan Motor (see chart) R Compressor Contactor 12 Black L3 TB L1 Compressor Brown 20 Black T2 Brown 59 60 42 14 Black 22 NC 3 Black Compressor T1 T3 2 13 L1 L2 L3 Aux. 1000 1 L3 11 C 10 Low Pressure Bypass 9 Yellow Black 19 500 38 Red Red (Low Spd) 58 L2 10 SECONDS Discharge Line TStat C 54 Black Hi Pressure Hi Pressure Control #1 Control #2 Y Black Phase Monitor L1 46 Coil Sensor Transformer L2 Aux. 57 Terminal Block 64 A Yellow L3 C 56 Bypass Relay (Optional) A L2 NC Yellow Black 30 Low Pressure Control Black L2 Black Red Red Blue Fuse Outdoor Fan Relay Brown 67 Red 17 Reversing Valve Yellow Black Black Pink Brown 17 Blue Red/White Yellow Orange Low Voltage Term. Block Purple Line 3 to power source or optional heater package Yellow Line 2 to power source or optional heater package Red Blue 39 5 Pin Plug for Indoor Blower Motor 4 5 3 L1 L2 L3 Line 1 to power source or optional heater package Yellow 23 22 4 Yellow C 3 Red CC 1 Black Y 6 Red C 2 4 Black L1 5 Red W2 RV L 3 Move Red Wire to 208V tap for 208V operation Black SENSOR R Blue B 9 Fuse Yellow R 14 L1 L1 Compressor Contactor Blue LO 6 Black 59 22 2 15 10 12 Yellow NC 1 460-60-3 Power Source 6 Pin Plug for Optional Heater Package 34 5 Pin Plug 47 Yellow NO COM 3 SEN JMP SPEEDUP 43 Indoor Blower Motor 16 Pin Plug 48 90 60 30 Note: Factory set on 60 min. cycle. Reconnect on 30 min. for 30 min. cycle or 90 min. for 90 min. cycle. Defrost Control C 6 1 4 3 6 Pin Plug for Heater Package A 15 10 2 14 9 6 12 3 1 16 Pin Plug for Indoor Blower Motor Wire Identification numbers Wires Connect 99 for Bard use only. if Option Not Used Factory Field Optional Standard High Voltage Diagram Low Voltage ! Ladder Diagram WARNING USE COPPER CONDUCTORS ONLY SUITABLE FOR AT LEAST 75° C. ! DANGER *ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING. Bard Mfg. Co. Bryan, Ohio 4096-335 B