Preview only show first 10 pages with watermark. For full document please download

Dial Thermostat - Salus Controls Nl

   EMBED


Share

Transcript

iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:32 Page 1 Dial Thermostat Models: VS05 I N S TA L L E R / U S E R M A N U A L iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:32 Page 2 Contents Contents Introduction. Product Compliance. Safety information. Mounting position and installation. System grouping and communication. User interface. LED indication. Icons used in this manual: Safety For latest PDF installation guide please go to www.salus-controls.com Important info Your benefit Box Contents Dial Thermostat Models: VS05 I N S TA L L E R / U S E R M A N U A L 1 x Installer / User manual 02 VS05 Installer Manual Fixing screws VS05 iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:32 Page 3 Product Compliance & Safety Information INTRODUCTION Thank you for purchasing the SALUS room thermostat VS05. The VS05 is a 230V dial thermostat which offers simple temperature control of your heating system. SALUS recommends that you use your VS05 with the SALUS KL10 wiring centre and VS10 digital room thermostat. The VS10 can be used as a group control thermostat to control groups of VS05’s. Please see pages 6 and 7. Product Compliance This product is CE compliant and meets the following EC Directives Electro-Magnetic Compatibility directive 2004/108/EC Low voltage Directive 2006/95/EC Safety Information Use in accordance with the regulations The SALUS VS05 is to be used for room control of hot water heating systems inside the house. Installation This product must be fitted by a competent person, and installation must comply with the guidance, standards and regulations applicable to the city, country or state where the product is installed. Failure to comply with the requirements of the relevant guidance, standards and regulations could lead to injury, death or prosecution. Always isolate the AC mains supply before installing or working on any components that require 230V AC 50Hz supply. We hope you enjoy this product... VS05 Installer Manual 03 iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:32 Page 4 Product Compliance & Safety Information Sources of danger The thermostat must be disconnected from mains supply before removing the cover. 230V AC Installer parameter settings The SALUS VS05 is equipped with installer parameters. See page 13. For the installer Please enter any parameter changes in the installer notes section. Emergency Switch off the voltage to the individual thermostat wiring centre or complete system. 04 VS05 Installer Manual iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:32 Page 5 Installation – Thermostat Mounting Mounting position and installation To ensure trouble free operation and efficient control, the unit is best positioned in a draft free area and at 130cm from the floor. Do not position the thermostat near any heat source, behind curtains, direct sunlight or an area of high humidity. 130cm Not to be positioned on an exterior wall. VS05 Installer Manual 05 iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:32 Page 6 System Overview Grouping and Communication Power and Switching Cable - used to power thermostats and drive output. Grouping and Communication cable. While the thermostats can function as standalone, installing this optional inexpensive communication cable allows the thermostats to communicate with the SALUS VS10 configured as a group control thermostat and used with the SALUS KL10 WC (both sold separately). The VS05 will follow instructions from the VS10 bringing central control of features such as Time Control, Holiday & Party functions as well as Frost Control. The VS05 can leave or re-enter group control at the slide of a switch. 06 VS05 Installer Manual VS10 Group Control Thermostat (sold separately ) iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:32 Page 7 System Overview Grouping and Communication The maximum number of groups per KL10 wiring centre is two. The group selection communication cable must correspond to the group terminals on the KL10 WC. Please refer to note 5 and the KL10 installation guide. Group 1 – For Example Down stairs Group 2 – For Example upstairs SALUS KL10 Wiring Centre VS05 Installer Manual 07 iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:32 Page 8 Installation – Thermostat Mounting 1 2 Gently remove front housing. 3 08 VS05 Installer Manual Wall Mounting For wall mounting, mark and mount the rear case to the wall. The VS05 is suitable for wall boxes with a centre hole distance of: 60mm iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:32 Page 9 Installation – Terminal Connections Understanding your terminal connections 1 Rear of VS05 2 3 3 2 1 Power Terminals 230 Vac Used for supplying power to the unit and switched output. Sensor Terminals Can be used for external Air or Floor sensor. Communication Terms 12VDC Two wire twisted pair can be used for grouping functions between VS10 and VS05. Also required for Heat/Cool changeover. VS05 Installer Manual 09 iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:33 Page 10 Installation – Thermostat Connections 5 x 20mm 5 x 20mm SL N L ZONE 1 SL N L SL N L ZONE 2 SL N L ZONE 3 SL N L ZONE 4 ZONE 5 SL N L ZONE 6 SL N L SL N L ZONE 7 ZONE 8 Optional communication connection 12VDC While the VS05 can function on its own, installing this optional, inexpensive communication cable allows the VS05 to communicate with the SALUS VS10 (sold separately). SL N L Zone 1 Example For more detail refer to note 5 on the wiring centre installation guide. 10 VS05 Installer Manual GND GND Group Group 11 iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:33 Page 11 Installation – Terminal Connections Check that the wiring is completed for: 1 Power Terminals 2 Sensor Terminals (if applicable) 3 Communication Terminals (optional but recommended) You are ready to secure the rear housing to the wall box Please use the screws provided. Ensure the orientation arrow is pointing upwards. VS05 Installer Manual 11 iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:33 Page 12 Installation 3 2 1 4 1 2 If any parameter settings need to be changed please refer to next page. 12 VS05 Installer Manual Fit the front housing to the rear housing as shown above. iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:33 Page 13 Installation – parameter setting 1 FUNCTION External sensor (optional) If you are fitting an external sensor for air/floor sensing please select temp here. It can be set from 0-45ºC and is preset at 27ºC. Please note the dip switches 2 need to be set for the correct external sensor type, see below. 2 DESCRIPTION DEFAULT Valve Exercising If the installer setting is to enable the valve exercising the dial thermostat will additionally send 5 minute pulse on actuator once a week. ENABLE PWM PWM output to drive actuator open/close. ON External sensor type Actuator type Air or floor. AIR Normally Closed or Normally Open. NC Reduced temp offset / Night setback 0, 4, 6 or 8 (only when used with VS10 and KL10). 4ºC VS05 Installer Manual 13 iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:33 Page 14 User Interface LED Indication Temperature Adjustment 5-30 oC The VS05 is no longer a member of the group and will ignore commands from the VS10 group control thermostat. Mode Selection The VS05 is a group member and will follow commands from the VS10 group control thermostat. The VS10 is switched off, frost protection of 5ºC is active. 14 VS05 Installer Manual iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:33 Page 15 LED Indication - Group Member Slide switch must be in position to follow group control thermostat VS10, see page 14. RED LED indicates that power is going to the thermostat in normal operation. The top LED will illuminate when room temperature falls below your required temperature. Green LED means that the thermostat is calling for heat. The group control thermostat will be in one of the following modes: VS10 group control thermostat display 1. 2. 3. For more details on VS10 please refer to VS10 manual If you do not want a VS05 to follow the group control thermostat VS10 please select or see previous page. VS05 Installer Manual 15 iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:33 Page 16 LED Indication - Group Member Slide switch must be in position to follow group control thermostat VS10, see page 14. To reduce annoyance factor, no LED is shown when the group control thermostat is in reduced temperature/night setback mode. See below. To adjust reduced temperature offset please refer to page 13. VS10 group control thermostat display Amber LED means that the thermostat is calling for heat in reduced/night setback mode. The group control thermostat will be in one of the following modes: 1. 2. For more details on VS10 please refer to VS10 manual If you do not want a VS05 to follow the group control thermostat VS10 please select or see page 14. 16 VS05 Installer Manual iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:33 Page 17 LED Indication - Group Member Slide switch must be in position to follow group control thermostat VS10, see page 14. Blue LED indicates the thermostat is in frost protection mode. Frost protection temperature is fixed at 5ºC. Green LED means that the temperature has fallen below the frost protection level the thermostat is calling for heat. The group control thermostat will be in one of the following modes: VS10 group control thermostat display 1. 2. For more details on VS10 please refer to VS10 manual If you do not want a VS05 to follow the group control thermostat VS10 please select or see page 14. VS05 Installer Manual 17 iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:33 Page 18 LED Indication - Manual mode To enter manual mode, slide the switch to the position. The thermostat will not follow the group control thermostat VS10 and will no longer be part of the group. The VS05 will work as a stand alone thermostat. RED Led indicates that power is going to the unit in normal operation. The top LED will illuminate when room temperature falls below your required temp. Green LED means that the unit is calling for heat. To return the VS05 to the group (if applicable) move the slide switch to 18 VS05 Installer Manual iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:33 Page 19 LED Indication -Permanent Frost Mode To enter manual mode, slide the switch to the position. The thermostat will not follow the group control thermostat VS10 and will no longer be part of the group. The VS05 will be in permanent frost protection. Blue LED indicates the thermostat is in frost protection mode. Frost protection temperature is fixed at 5ºC. Green LED indicates the temperature has fallen below the frost protection level and the thermostat is calling for heat. To return the VS05 to the group (if applicable) move the slide switch to VS05 Installer Manual 19 iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:33 Page 20 Technical Detail MODEL TYPE TEMPERATURE Scale Tolerance Set Temperature range Frost Protection CONTROL ENVIRONMENT RATINGS Operating Temperature Storage Temperature Operating Humidity (non condensed) POWER SOURCE CONTROL SWITCH AND RATING Loading Input AGENCY APPROVED 20 VS05 Installer Manual VS05 Wired dial thermostat designed for 230V AC heating/cooling applications Celsius 0.5 ºC 5-30 ºC 5ºC ON-OFF control / PWM control 0ºC to +50 ºC -20ºC to +60 ºC 5-95 %RH 230Vac 50Hz Maximum 3A at SL terminal Comm Connection 12VDC CE iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:33 Page 21 Installer Notes VS05 Installer Manual 21 iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:33 Page 22 Installer Notes 22 VS05 Installer Manual iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:33 Page 23 Warranty SALUS Controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its specification, for a period of five years from the date of installation. SALUS Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product. Customer Name: ............................................................................................................................. Customer Address: .......................................................................................................................... ............................................................................... Post Code: ........................................................ Tel No: ........................................................ Email: ......................................................................... Engineers Company: ....................................................................................................................... Tel No: ......................................................... Email: ........................................................................ Instalation Date: .............................................................................................................................. Engineers Name: ............................................................................................................................ Engineers Signature: ....................................................................................................................... VS05 Installer Manual 23 iT600 VS05 Installer - User Manual 005_Layout 1 02/07/2014 16:33 Page 24 SALUS Controls plc SALUS House Dodworth Business Park South, Whinby Road, Dodworth, Barnsley S75 3SP, UK. SALES: T: +44 (0) 1226 323961 E: [email protected] TECHNICAL: T: +44 (0) 1226 323961 E: [email protected] www.salus-controls.com SALUS Controls is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification, design and materials of products listed in this brochure without prior notice. Issue Date: April 2014 00086/2 For PDF Installation guide please go to www.salus-controls.com