Preview only show first 10 pages with watermark. For full document please download

Diamond E-400i Data Sheet

   EMBED


Share

Transcript

DIAMOND E-400i Liquid-Cooled, RF-Excited OEM Industrial CO2 Laser Features • Wide operating power range • Integrated but detachable RF power supply • Peak power >_1.7 kW • Pulse frequency from single-shot to 100 kHz • Fast rise-and-fall time • Compact design • Equipped with on-board internet-accessible diagnostics and control • Outstanding beam quality • Excellent power stability • Low-cost OEM configuration Top View Mechanical Specifications 3X Ø 6.6 mm Thru (0.26 in.) 254 mm (10.0 in.) Min. Clearance Required for Lifting Spreader 203 mm (8.0 in.) Min. Clearance 336.5 mm (13.25 in.) 50 mm (1.97 in.) 26.5 mm (1.05 in.) 25 mm (0.98 in.) Min. Clearance Required for Service Access 948.8 mm (37.35 in.) 9.5 mm (0.38 in.) 320.4 mm 80 mm (12.62 in.) (3.15 in.) 151.8 mm 120.4 mm (5.98 in.) (4.74 in.) 53.9 mm (2.12 in.) Center of Gravity 38.2 mm (1.51 in.) 138.4 mm (5.45 in.) 182.9 mm (7.2 in.) Front View Ø12 mm (0.47 in.) Side View Ø63.5 mm (2.5 in.) 40 mm (1.57 in.) Min. Clearance Required for Interface Connections Output Beam 49.8 mm (1.96 in.) 203 mm (8.0 in.) 40.7 mm (1.6 in.) 21 mm (0.83 in.) Customer Mounting Surface 1066.7 mm (42.0 in.) 536 mm (21.1 in.) 30.6 mm (1.21 in.) 1036.1 mm (40.79 in.) 995 mm (39.17 in.) 162 mm (6.38 in.) 221.1 mm (8.71 in.) 218.9 mm (8.62 in.) 38.2 mm (1.51 in.) 115.3 mm (4.54 in.) Center of Gravity Bottom View Superior Reliability & Performance 203 mm (8.0 in.) DIAMOND™ E-400i Liquid-Cooled, RF-Excited OEM Industrial CO2 Laser System Specifications1 Wavelength (µm) Output Power (W) Power Range2 (W) Nominal Peak Power3 (W) Power Stability (%) Mode Quality (M2) Beam Waist Diameter4 at 1/e2 (mm) Full-Angle Beam Divergence (mrad) Polarization (perpendicular to baseplate) Beam Ellipticity Pulse Frequency (kHz) RF Excitation Pulse Width Range (µsec) Duty Cycle Limit (%) Fall Time (µs) Weight Dimensions Facilities Requirements DC Coolant Heat Load (kW) Coolant Flow Rate (l/min.) Coolant Temperature Range Coolant5 Coolant Differential Pressure6 (kPa) Coolant Maximum Static Pressure (kPa) <_7.5 >_ 9.5 Ambient Temperature Relative Humidity7 (non-condensing)(%) Altitude 5 to 45°C (41 to 113°F) <_95 <_2000 m (<_6500 ft.) Environmental Conditions 1 2 3 4 5 6 7 DC Power Supply (VDC) Maximum DC Current (A) Peak Current (A) 9.1 to 9.5 >_ 350 35 to 350 1700 ±6 <_1.2 9.0 ±1.5 <_1.6 Linear _> 100:1 _ > 0.83, <_1.2 Single-shot to 100 2 to 800 <_40 <_55 75 kg (165 lbs.) 948.8 x 336.4 x 320.4 mm (37.35 x 13.25 x 12.62 in.) 48 ±1.0% <_150 <_260 for a minimum of 1 ms 23°C ±3 (73.4°F ±1) Anti-corrosion treated water 344 (50 psi) @ 9.5 l/min (2.5 gpm) 827 (120 psi) All specifications apply when the product is operated in accordance with the guidelines defined in the operators manual. Output stability specification may not be met at lowest power or at acoustic resonances. Measured for a 50 µs pulse width at 1 kHz repetition frequency. Beam diameter is measured at the waist location, located ~0.5 m from the laser output. See manual for details. This differential pressure is from system input to output and does not include the pressure drop from chiller fittings and the supply and return hose. Do not operate at or below dew point. All specifications subject to change without notice. Coherent, Inc. warrants to the original purchaser for a period of two years from the date of delivery that the Diamond E-400i is free from defects in material and workmanship. The warranty does not apply to any unit damaged by accident, abuse or operation in a manner inconsistent with the procedures and specifications outlined in the manual supplied with the laser. The Diamond E-400i is a laser component that does not include all safety features as required by the FDA and the Center for Devices and Radiological Health (CDRH). It is sold solely to qualified manufacturers who in their end product will supply all interlocks and indicators, and will comply fully with CDRH regulations and/or local regulatory agencies. www.Coherent.com Printed in the U.S.A. MC-046-08-0M1110Rev.B Copyright © 2010 Coherent, Inc. Coherent, Inc. 5100 Patrick Henry Drive Santa Clara, CA 95054 phone (800) 527-3786 (408) 764-4983 fax (408) 764-4646 e-mail [email protected] Benelux +31 (30) 280 6060 China +86 (10) 6280 0209 France +33 (0)1 6985 5145 Germany +49 (6071) 968 333 Italy +39 (02) 34 530 214 Japan +81 (3) 5635 8700 Korea +82 (2) 460 7900 UK +44 (1353) 658 833 INVISIBLE AND VISIBLE LASER RADIATION. AVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION. CLASS 4 LASER PRODUCT PER IEC60825-1:2007/EN60825-1:2007 635 nm to 670 nm VISIBLE (1 mW) 9.1 µm to 10.8 µm INVISIBLE 650W MAX. AVG. 4J MAX. 1 ms PULSE