Preview only show first 10 pages with watermark. For full document please download

Digital And Analogue Time Switches

   EMBED


Share

Transcript

english TIME 9900642 1210 We reserve the right to make technical modifications and improvements. Digital and analogue time switches Catalogue_ZEIT_GB_2010.indd 1 24.03.10 12:03 TIME 2 Catalogue_ZEIT_GB_2010.indd 2 http weitere technische Daten unter: www.theben.de/produkt/ Artikel-Nr. 1 24.03.10 12:03 TIME Digital time switches Section overview Program Number of channels Memory locations External inputs PC interface Memory card Connection type included Type Page 1 56 – ✓ – Spring terminals TR 610 top2 8 2 56 – ✓ – Spring terminals TR 612 top2 8 TR 611 top2 TR 611 top2 RC 8 10 10 DIN rail, 2 modules Weekly program 1 84 1 ✓ ✓ Spring terminals 84 2 ✓ ✓ Spring terminals TR 622 top2 54 – ✓ – Spring terminals SELEKTA 170 top2 12 84 1 ✓ – Spring terminals SELEKTA 171 top2 RC 12 2 84 2 ✓ – Spring terminals SELEKTA 172 top2 12 1 28 – – – Screw terminals TR 610 top 24V 15 2 42 – – – Screw terminals TR 612 top 24V 15 1 28 – – – Screw terminals TR 608 top 14 Yearly program, Astronomical program 1 800 1 ✓ 2 800 2 ✓ – – – – – Yearly program, Astronomical program 4 800 4 ✓ – 4 – 4 2 42 1 2 Weekly program, Astronomical program Weekly program 1 DIN rail, 1 module Weekly program DIN rail, 3 modules – Spring terminals TR 641 top2 20 ✓ Spring terminals TR 641 top2 RC 20 – Spring terminals TR 642 top2 20 ✓ Spring terminals TR 642 top2 RC 20 – Spring terminals EM LAN top2 22 – Spring terminals TR 644 top2 20 ✓ Spring terminals TR 644 top2 RC 20 – – Spring terminals EM 4 top2 22 – – – Screw terminals TR 685/2 top 23 42 – – – Screw terminals TR 635 top 24 2 42 – – – Screw terminals TR 636 top 24 Weekly program 1 42 – – – Screw terminals TR 030 top 26 Weekly program 36 – – – Plug-in theben-eltimo 020 S 27 1 33 – – – Plug-in theben-eltimo 020 S DCF 27 DIN rail, 4 modules Wall installation/3-point mounting Weekly program Front panel/wall installation Weekly program Flush-mounted Socket (plug-in) http weitere technische Daten unter: 15.03.2010 Catalogue_ZEIT_GB_2010.indd 3 www.theben.de/produkt/ Artikel-Nr. 3 24.03.10 12:03 Digital time switches TIME TR 611 top2 DIN-rail installation Everything top: Programming with operator guidance Precise programming, every second Daily and weekly program 4 Catalogue_ZEIT_GB_2010.indd 4 24.03.10 12:03 Digital time switches TIME Long Breals, Small Cost. Of course students, employers and workers need breaks. Theben digital timers control the signals that mark the start and end of breaks - reliably and to the second. They are quick and easy to set up via text guidance on the timer, OBELISK top2 memory card, or with complex programs that can be used from the comfort of your desk via drag and drop OBELISK top2 software. TR 611 top2 DIN-rail installation DCF77 Step by step text guidance in illuminated screen makes programming fun even in the darkest cellars. QUICK SETTING Thanks to Theben's ingenious copier function, weekly program settings are even easier to set. Additional days of the week with the same switching times can be copied using the OK button. EXACT CONTROL Time signals and cycle switching times (PULSE/PAUSE) can be quickly and easily programmed at the required time. DUAL PROGRAMMING With the memory card inserted, an alternative stored program can be carried out. When the card is removed, the program stored in the time switches carries on seamlessly. EXTERNAL CONTROL INPUT One switch or several buttons per channel can be connected to the external control input. The permanent ON, permanent OFF, switching pre-selection, sequence timer (egg timer function) and channel enabling (activation of timer) functions are available. DCF77-/GPS RADIO CONTROL Extremely accurate timing through automatic time synchronisation with the DCF 77 time signal transmitter in Mainflingen near Frankfurt or time synchronisation with the GPS-Signal (DCF and/or GPS antenna optional) CAN BE CONFIGURED FOR SINGLE OR DOUBLE USE Two wires can be connected per terminal. Each of the wires is secured by its own spring clamp. 5 Catalogue_ZEIT_GB_2010.indd 5 24.03.10 12:03 OBELISK top2 programming set TIME OBELISK top2 Programming "Á la carte": the easy alternative OBELISK top2* programming set for all top2 devices: TR top2 LUNA top2 SELEKTA top2 *OBELISK top2 software can be downloaded free of charge at www.theben.de 6 Catalogue_ZEIT_GB_2010.indd 6 24.03.10 12:04 OBELISK top2 programming set TIME Time to rinse. In restaurants, bars and clubs the regular and correct rinsing of urinals is a hygienic necessity. Here the TR 611 top2 time switch offers a water saving and costefficient solution. The rinsing cycles can be adapted to the prevailing circumstances – visitor frequency, opening hours, days of the week– and the precise, to the second, programming controls water consumption. OBELISK top2 Programming Day of the week Block formation UP/DOWN minute and/or second settings Graph or table programming possible Intuitive OBELISK top2 PC software programming with its simple drag and drop selections. This makes entering switching times as simple as editing, printing and copying. Programs are easily saved using the OBELISK memory card. Free demo software is available at www.theben.de SPECIAL PROGRAM Insert memory card and overwrite program or perform set special program. The standard program is restored once it is removed. COPYING FROM TIME SWITCH TO TIMER Ideal if several timers with the same program are installed, e. g. for street lighting, shopping chains, public buildings etc. CHANGING SWITCHING TIMES By clicking the times, ± fields then appear for editing or overwriting switching times. Day of the week blocks can be changed by clicking on the ticks. DOCUMENTATION Printing and storing on a hard drive for straightforward program changes on PC. PROGRAM OVERVIEW It shows at a glance what the week's switching program looks like. Subsequent changes and to the minute time changes can be made at any time. ON BUTTON Click on the program button again for the desired day of the week and pull across to the approximate time and pull down; this programs additional days for the same switching time. The program line now appears at the bottom. 7 Catalogue_ZEIT_GB_2010.indd 7 24.03.10 14:03 Digital time switches TIME DIN-rail, 2 modules TimeDigital time switchesDIN-rail, 2 modules TR top2 Digital time switches with weekly program TR 610 top2 TR 612 top2 Description Common functions ■ ■ ■ ■ ■ ■ ■ ■ ■ Digital time switch with weekly program DuoFix spring terminals Text-oriented user guidance in the display 56 memory locations Interface for OBELISK top2 memory card (PC programming) 10 year power reserve (lithium battery) Zero-cross switching for relay-saving switching and high lamp loads ON-OFF switching times ■ ■ ■ ■ ■ ■ Switching preselection Permanent ON/OFF switching Integrated operating hour counter Holiday program Display backlit (can be turned off) PIN coding Automatic summer/winter time changeover TR 610 top2 G As TR 610 top2, but: ■ special device with extra relais (gold-bonded contacts) for switching of very low loads TR 612 top2 ■ 2 channels TR 610 top2 ■ 1 channel Product selection Program Programfunctions Number of channels 1 Weekly program Switching load < 1 mA Operating voltage Type Article number – 230 – 240 V AC TR 610 top2 61001031) ✓ 230 – 240 V AC TR 610 top2 G 6100110 12 – 24 V UC TR 610 top2 24V 6104100* – 230 – 240 V AC TR 612 top2 61201031) 12 – 24 V UC TR 612 top2 24V 6124100* ON/OFF 2 *Available June 2010 1) Languages: GB, E, P, F, D (other article numbers with additional languages on request) 8 Catalogue_ZEIT_GB_2010.indd 8 http Additional technical data at: www.theben.de/product/ Article number 24.03.10 12:04 Digital time switches TIME Technical data TR 610 top2 TR 610 top2 G TR 610 top2 24V TR 612 top2 TR 612 top2 24V 12 – 24 V UC 230 – 240 V AC 12 – 24 V UC 230 – 240 V AC Operating voltage Frequency 50-60 Hz Width 2 modules Installation type DIN-rail Power reserve 10 years Max. switching capacity at 250 V AC, cos φ = 1 TR top2 DIN-rail, 2 modules 16 A Max. switching capacity at 250 V AC, cos φ = 0.6 10 A 2A 2600 W Incandescent/halogen lamps approx.10 mA Min. switching capacity 10 A 1400 W 2600 W <1 mA 1400 W approx.10 mA 1 min Shortest switching time ≤ ± 0.5 s/day(Quartz) Time accuracy 3 VA Power consumption V Test approvals – V V V IP 20 Type of protection II in accordance with EN 60 730-1 Protection class –30 °C … +55 °C Ambient temperature Accessories Front panel mounting kit ■ Art.No.: 9070001 Details Page 54 ▶ OBELISK top2 PC set ■ Art.No.: 9070409 Details Page 54 ▶ OBELISK top2 memory card ■ Art.No.: 9070404 Details Page 55 Wall installation kit 35 mm ■ ▶ Art.No.: 9070064 Details Page 55 ▶ Connection example TR 610 top2 TR 612 top2 L N 4 5 6 L C2 C1 1 2 C1 3 1 2 N L L 3 N N L L http Additional technical data at: www.theben.de/product/ Article number Catalogue_ZEIT_GB_2010.indd 9 9 24.03.10 12:04 Digital time switches TIME DIN-rail, 2 modules TimeDigital time switchesDIN-rail, 2 modules TR top2 Digital time switches with weekly program TR 611 top2 TR 611 top2 RC TR 622 top2 Description Common functions ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Digital time switch with weekly program DuoFix spring terminals Text-oriented user guidance in the display 84 memory locations Interface for OBELISK top2 memory card (PC programming) OBELISK memory card included in delivery 10 year power reserve (lithium battery) Zero-cross switching for relay-saving switching and high lamp loads ON-OFF switching times Pulse program Cycle program ■ ■ ■ ■ ■ ■ ■ ■ Switching preselection Permanent ON/OFF switching Count-down timer Integrated operating hour counter Holiday program 2 random programs Display backlit (can be turned off) PIN coding Automatic summer/winter time changeover TR 611 top2 RC ■ ■ ■ Time synchronisation option via connection of external DCF or GPS antenna (additional power unit required for GPS if only one device is connected to the antenna). 1 channel External control input TR 622 top2 ■ ■ 2 channels 2 external control inputs TR 611 top2 ■ ■ 1 channel External control input Product selection Program Programfunctions Number of channels Control inputs Time based on Operating voltage Type Article number 230 – 240 V AC TR 611 top2 61101031) 12 – 24 V UC TR 611 top2 24V 6114100* 230 – 240 V AC TR 611 top2 RC 6110300 Quartz Weekly program ON/OFF Pulse Cycle 1 1 Quartz/DCF77/ GPS 2 2 Quartz 12 – 24 V UC TR 611 top2 RC 24V 6114300* 230 – 240 V AC TR 622 top2 62201031) 12 – 24 V UC TR 622 top2 24V 6224100* *Available June 2010 Languages: GB, E, P, F, D (other article numbers with additional languages on request) 1) 10 Catalogue_ZEIT_GB_2010.indd 10 http Additional technical data at: www.theben.de/product/ Article number 24.03.10 12:04 Digital time switches TIME Technical data Operating voltage TR 611 top2 TR 611 top2 24V TR 611 top2 RC TR 611 top2 RC 24V TR 622 top2 TR 622 top2 24V 230 – 240 V AC 12 – 24 V UC 230 – 240 V AC 12 – 24 V UC 230 – 240 V AC 12 – 24 V UC Frequency 50-60 Hz Width 2 modules Installation type DIN-rail Power reserve 10 years Max. switching capacity at 250 V AC, cos φ = 1 16 A Max. switching capacity at 250 V AC, cos φ = 0.6 10 A TR top2 DIN-rail, 2 modules 2600 W Incandescent/halogen lamps approx.10 mA Min. switching capacity 1s Shortest switching time ≤ ± 0.5 s/day (Quartz) or DCF77/ GPS ≤ ± 0.5 s/day (Quartz) Time accuracy ≤ ± 0.5 s/day (Quartz) 3 VA Power consumption V Test approvals V V V V V IP 20 Type of protection II in accordance with EN 60 730-1 Protection class –30 °C … +55 °C Ambient temperature Accessories OBELISK top2 PC set ■ OBELISK top2 memory card Art.No.: 9070409 Details Page 54 ■ ▶ Art.No.: 9070404 Details Page 55 Wall installation kit 35 mm ■ ▶ Additional accessories Art.No.: 9070064 Details Page 55 ■ ▶ ■ ■ ■ Front panel mounting kit Page 54 Details top2 RC–DCF antenna Details Page 54 Antenna top2 RC-GPS Page 54 Details Power unit top2 GPS Details Page 54 ▶ ▶ ▶ ▶ Connection example TR 611 top2 TR 611 top2 RC L N TR 622 top2 L N Ext1 4 Ext1 5 6 L C2 RC GPS C1 1 2 max. 100 m max. 100 m max. 100 m max. 100 m RC DCF RC Ext1 Ext2 C1 3 1 N L L 2 C1 3 1 N L L http 2 3 N N L L Additional technical data at: www.theben.de/product/ Article number Catalogue_ZEIT_GB_2010.indd 11 11 24.03.10 12:04 Digital time switches TIME DIN-rail, 2 modules SELEKTA top2 TimeDigital time switchesDIN-rail, 2 modules Astronomical time switches with weekly program SELEKTA 170 top2 SELEKTA 171 top2 RC SELEKTA 172 top2 Description Common functions ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Astronomical time switch with weekly program Astronomical switching function (automatic calculation of sunrise and sunset times for the whole year) DuoFix spring terminals Text-oriented user guidance in the display Interface for OBELISK top2 memory card (PC programming) 10 year power reserve (lithium battery) Zero-cross switching for relay-saving switching and high lamp loads Calculated astronomical switching times Programmable ON-OFF switching times Switching preselection Permanent ON/OFF switching ■ ■ ■ ■ Integrated operating hour counter Holiday program Display backlit (can be turned off) PIN coding Automatic summer/winter time changeover ■ 1 channel 54 memory locations ■ ■ ■ 84 memory locations 3 special programs with yearly date function per channel Count-down timer As SELEKTA 170 top2, but: ■ ■ SELEKTA 171 top2 RC ■ ■ SELEKTA 172 top2 SELEKTA 170 top2 ■ ■ Time synchronisation via connection of external DCF or GPS antenna (additional positioning for astronomical program with GPS antenna, top2 GPS power unit required, if only one device is connected to the antenna) 1 channel External control input ■ ■ ■ ■ 2 channels Channel 1 or channel 2 can also be used purely as time switch channel 2 external control inputs 84 memory locations 3 special programs with yearly date function per channel Count-down timer Product selection Program Special program Number of channels Control inputs Time based on – Quartz 1 Quartz/DCF77/GPS 2 Quartz – Weekly program, Astronomical program 1 Yearly date function 2 Operating voltage Type Article number 230-240 V AC SELEKTA 170 top2 1700100 12-24 V UC SELEKTA 170 top2 24V 1704100* 230-240 V AC SELEKTA 171 top2 RC 1710100 12-24 V UC SELEKTA 171 top2 RC 24V 1714100* 230-240 V AC SELEKTA 172 top2 1720100 12-24 V UC SELEKTA 172 top2 24V 1724100* *Available June 2010 12 Catalogue_ZEIT_GB_2010.indd 12 http Additional technical data at: www.theben.de/product/ Article number 24.03.10 12:04 Digital time switches TIME Technical data Operating voltage SELEKTA 170 top2 SELEKTA 170 top2 24V SELEKTA 171 top2 RC SELEKTA 171 top2 RC 24V SELEKTA 172 top2 SELEKTA 172 top2 24V 230-240 V AC 12-24 V UC 230-240 V AC 12-24 V UC 230-240 V AC 12-24 V UC 2600 W 1400 W Frequency 50-60 Hz Width 2 modules Installation type DIN-rail Power reserve 10 years Max. switching capacity at 250 V AC, cos φ = 1 16 A Max. switching capacity at 250 V AC, cos φ = 0.6 10 A 2600 W Incandescent/halogen lamps 1400 W 2600 W 1400 W SELEKTA top2 DIN-rail, 2 modules approx.10 mA Min. switching capacity 1 min Shortest switching time ≤ ± 0.5 s/day (Quartz) or DCF77/GPS ≤ ± 0.5 s/day (Quartz) Time accuracy ≤ ± 0.5 s/day (Quartz) 3 VA Power consumption V Test approvals V V V V V IP 20 Type of protection II in accordance with EN 60 730-1 Protection class -30 °C  … +55 °C Ambient temperature Accessories OBELISK top2 PC set ■ OBELISK top2 memory card Art.No.: 9070409 Details Page 54 ▶ ■ Wall installation kit 35 mm Art.No.: 9070404 Details Page 55 ■ ▶ Additional accessories Art.No.: 9070064 Details Page 55 ■ ▶ ■ ■ ■ Front panel mounting kit Page 54 Details antenna top2 RC–DCF Details Page 54 Antenna top2 RC-GPS Page 54 Details Power unit top2 GPS Details Page 54 ▶ ▶ ▶ ▶ Connection example SELEKTA 170 top2 L SELEKTA 171 top2 RC N L SELEKTA 172 top2 4 N Ext1 max. 100 m Data RC DCF 1 2 1 N L L 2 L C1 1 3 N L L http 6 Ext1 Ext2 RC GPS C1 3 max. 100 m max. 100 m – + C1 5 C2 2 3 N N L L Additional technical data at: www.theben.de/product/ Article number Catalogue_ZEIT_GB_2010.indd 13 13 24.03.10 12:04 Digital time switches TIME DIN-rail, 1 module TimeDigital time switchesDIN-rail, 1 module TR top TR 608 top Description Digital time switch with weekly program 1 channel Screw terminals Text-oriented user guidance in the display 28 memory locations 3 year power reserve (exchangeable lithium battery) ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ON-OFF switching times Switching preselection Permanent ON/OFF switching PIN coding Automatic summer/winter time changeover Product selection Program Number of channels Memory locations Programfunctions Operating voltage Type Article number Weekly program 1 28 ON/OFF 230 V AC TR 608 top 6080002 Technical data TR 608 top Operating voltage 230 V AC Incandescent/halogen lamps Frequency 50-60 Hz Shortest switching time Width 1 module Time accuracy 1000 W 1 min ≤ ± 1 s/day(Quartz) Installation type DIN-rail Power consumption Power reserve 3 years Test approvals V Type of protection IP 20 Max. switching capacity at 250 V AC, cos φ = 1 16 A Max. switching capacity at 250 V AC, cos φ = 0.6 6A Wall installation kit 17.5 mm Art.No.: 9070065 Page 55 Details ▶ II in accordance with EN 60 730-1 Protection class –10 °C … +55 °C Ambient temperature Accessories ■ 2.5 VA Connection example Front panel mounting kit ■ Art.No.: 9070001 Page 54 Details ▶ TR 608 top L N C1 1 2 3 N L L 14 Catalogue_ZEIT_GB_2010.indd 14 http Additional technical data at: www.theben.de/product/ Article number 24.03.10 12:04 Digital time switches TIME DIN-rail, 1 module TimeDigital time switchesDIN-rail, 2 modules TR top Digital time switches with weekly program – 110–120 V AC/12–24 V UC Description Digital time switch with weekly program Screw terminals Text-oriented user guidance in the display 10 year power reserve (lithium battery) ON-OFF switching times Switching preselection Permanent ON/OFF switching PIN coding Automatic summer/winter time changeover ■ ■ ■ ■ ■ ■ ■ ■ ■ TR 610 top 120V/24V ■ ■ 1 channel 28 memory locations TR 612 top 120V/24V ■ ■ 2 channels 42 memory locations Product selection Program Number of channels Memory locations 1 Programfunctions 28 Weekly program ON/OFF 2 42 Operating voltage Type Article number – 110 – 120 V AC TR 610 top 120V 6101814 – 12 – 24 V UC TR 610 top 24V 6104002 ✓ 110 – 120 V AC TR 610 top 120V 6101814 – 110 – 120 V AC TR 612 top 120V 6121814 – 12 – 24 V UC TR 612 top 24V 6124002 Technical data TR 610 top 120V/24 V, TR 612 top 120V/24V 110-120 V AC/12-24 V UC Operating voltage Frequency 50-60 Hz Shortest switching time Width 2 modules Time accuracy Installation type DIN-rail Power reserve 10 years Max. switching capacity at 250 V AC, cos φ = 1 16 A Max. switching capacity at 250 V AC, cos φ = 0.6 10 A Wall installation kit 35 mm Art.No.: 9070064 Page 55 Details ▶ 1 min ≤ ± 1 s/day(Quartz) 6 VA Power consumption VW Test approvals Protection rating IP 20 Protection class II in accordance with EN 60 730-1 Ambient temperature –10 °C … +55 °C Connection example Accessories ■ 1150 W Incandescent/halogen lamps Front panel mounting kit ■ TR 610 top 120V Art.No.: 9070001 Page 54 Details ▶ TR 612 top 120V L N 4 5 6 L C2 C1 1 2 C1 3 1 N L L http 2 3 N N L L Additional technical data at: www.theben.de/product/ Article number Catalogue_ZEIT_GB_2010.indd 15 15 24.03.10 12:04 Digital yearly time switches TR 644 top2 RC TR top2 TIME Yearly time switches with GPS and 4 channel extension 16 Catalogue_ZEIT_GB_2010.indd 16 24.03.10 12:04 Digital yearly time switches TIME Annual and Astronomical Programs: If the switching channel is operated with an astronomical program, then the digital time switch calculates the sunrise and sunset times for each day of the year. As these vary according to location and time zone, the location coordinates, consisting of longitude and latitude, time zone and the current date, are required to perform the calculation. The lighting connected to the timer is switched on to the minute in the evening and off again in the morning, based on the calculated times. TR 644 top2 RC TR top2 C1 C2 The simple annual program can be upgraded and optimised with diverse additional functions. Holiday and bank holiday programmes as well as break signals or various programmes for lighting, heating, ventilation and air conditioning are viable for every season. ASTRO FUNCTION The astronomical program, in addition to the time switch program, switches to sunrise and sunset times depending on the season and location. Offset for taking into account remaining light after sunset or mountain shadows. Easy set-up using city databases with stored coordinates. Zero cross switching LAN LAN module enables direct remote access via LAN network or the internet on the time switch. Furthermore, remote reading of the switching program and remote programming is possible. COPY The same program can be saved on several clocks in a flash with an insert able memory card, even without software. The annual clock program is copied on the inserted memory card and can then be copied onto as many clocks as needed and also used as a back-up copy of the program. EXTENSION Extension devices can be connected to the data bus. 4 channel upgrade module EM 4 top2 enables upgrading to 5, 6 and/or 8 channels. DUAL PROGRAMMING In schools and gyms, e.g. occupancy changes often occur. No problem - an adjusted program on the memory card can be inserted in the time switch. If the old program is needed once more, then just remove the memory card. DCF77/GPS Time synchronisation via connection of external DCF77 or GPS antennas. Additional positioning required for astronomical program with GPS. SIMULATION IN DISPLAY Simulation takes into account priority levels, bank holidays and holiday times of individual programmes and displays the switch times on all channels. INPUT External button/switch input per channel for easy pre-selection switch, lapsed time counter or permanent ON and/or OFF switching. SERVICE Integrated elapsed time counter separate for each channel with reset option available. Additional service function for monitoring maintenance intervals e.g for light sources. TERMINALS Duo Fix spring terminal for 2 conductor, wire or cable. In this case, each wire is held by its own DuoFix screwless terminals. ZERO-CROSS SWITCHING Zero-cross switching enables the switching of higher motor and lamp loads and extends the life of the builtin relay and lamps being switched. 17 Catalogue_ZEIT_GB_2010.indd 17 24.03.10 12:04 Digital time switches OBELISK top2 Programming TIME Intuitive programming on PC 18 Catalogue_ZEIT_GB_2010.indd 18 24.03.10 12:04 Digital time switches TIME OBELISK top2 programming set for TR top2, LUNA top2 and SELEKTA top2. Suitable for PC operating systems Windows/XP, VISTA and WINDOWS 7. Connection via USB interface. Delivery includes OBELISK CD, programming adapter, USB cable and OBELISK memory card. SOFTWARE OBELISK top2, intuitively operable Software for 19 different Theben devices, from a twilight switch to an astronomical switch as well as weekly and annual time switches. That means no rethinking, because the programming principle is the same for all devices that naturally saves time and money. OFFSET AND ASTRO-IMPULSE The offset function enables individual adjustment of astronomical times up to +- 120 min. This correction factor enables adjustment for e.g. valleys where the sun sets earlier. Energy can be saved by turning lighting on later and off earlier. The power-on time can be individually determined with the Astro-Impulse. PROGRAM Annual clock with basic weekly program and 14 different weekly programs with priority levels and date ranges. In addition to switching times, impulse and cyclical switching times are programmable as well. PUBLIC HOLIDAYS Public holidays do not have to be programmed individually, because legal public holidays have already been sorted by country and state in OBELISK top2 database. Annual reprogramming of public holidays is no longer necessary, because public holidays are automatically updated to the correct date for the following year. ASTRO PROGRAMM Many functions within a building need to be controlled depending upon sunrise and sunset times. Since this occurs at different times depending on the season, an astronomical program is required. It takes the geographical location in the calculation into account as well, so that the clock switches directly to sunrise and sunset times. Location input is simple via the city database or naturally by entering the longitude and latitude. OPERATING HOURS Even operating hour monitoring of each channel and maintenance interval displayed for the user is already integrated into the time switch. A signal is sent via a common switch channel of when maintenance is required. Manual switching by the user via external buttons/ switches is possible at any time and is included in the operating hours. OBELISK top2 Programming SIMULATION ON THE PC Simulation takes into account priority levels, bank holidays, astronomical times and holiday times of individual programmes and displays the switch times on all channels. Every short impulse can be checked via the scroll and zoom function. REMOTE MAINTENANCE The customer can change the program with the LAN interface module from their desk - this saves driving expenses and allows for fast service. Users can also use remote software operation via the network or the internet. PROJECT DOCUMENTATION Every project can be saved on the PC with customer address, number, etc as well as users, who are connected to individual channels. This makes calculation and later program changes easier. The OBELISK top2 program enables smooth program documentation for the customer on paper with just a push of a button. Even data export is possible e.g. via EXCEL. 19 Catalogue_ZEIT_GB_2010.indd 19 24.03.10 12:04 Digital time switches TIME DIN-rail, 3 modules, 4 modules TimeDigital time switchesDIN-rail, 3 modules, 4 modules TR top2 Digital time switches with yearly and astronomical time program TR 641 top2 TR 642 top2 RC TR 644 top2 Description Common functions ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Digital time switch with yearly and astronomical time program DuoFix spring terminals Text-oriented user guidance in the display 800 memory locations Interface for OBELISK top2 memory card (PC programming) 8 year power reserve (lithium battery) Zero-cross switching for relay-saving switching and high lamp loads ON-OFF switching times Pulse program Cycle program Extensive annual clock functions Astronomical time switch function (automatic calculation of sunrise and sunset times for the whole year) Switching preselection ■ ■ ■ ■ ■ ■ ■ Permanent ON/OFF switching Count-down timer Integrated operating hour counter Holiday program 2 random programs Display backlit (can be turned off) PIN coding Automatic summer/winter time changeover ■ ■ TR 642 top2 ■ ■ ■ ■ As TR 641 top2 RC, but: ■ 1 channel External control input ■ ■ 2 channels 2 external control inputs TR 644 top2 ■ TR 641 top2 RC ■ 2 channels 2 external control inputs TR 642 top2 RC ■ TR 641 top2 Extension module can be connected OBELISK memory card included in delivery ■ Time synchronisation via connection of external DCF or GPS antenna (additional positioning for astronomical program with GPS antenna) 1 channel External control input 4 channels 4 external control inputs TR 644 top2 RC As TR 641 top2 RC, but: ■ ■ 4 channels 4 external control inputs Product selection Program Number of channels Control inputs 1 1 Yearly program, Astronomical program 2 2 4 4 Time based on Memory card included Quartz – Quartz/DCF77/GPS ✓ Quartz – Quartz/DCF77/GPS ✓ Program functions ON/OFF Pulse Cycle Operating voltage Type Article number 110-240 V AC TR 641 top2 6410100* 110-240 V AC TR 641 top2 RC 6410300* 110-240 V AC TR 642 top2 6420100* 110-240 V AC TR 642 top2 RC 6420300* Quartz – 110-240 V AC TR 644 top2 6440100* Quartz/DCF77/GPS ✓ 110-240 V AC TR 644 top2 RC 6440300* *Available July 2010 20 Catalogue_ZEIT_GB_2010.indd 20 http Additional technical data at: www.theben.de/product/ Article number 24.03.10 12:04 Digital time switches TIME Technical data TR 641 top2 RC TR 641 top2 TR 642 top2 RC TR 642 top2 TR 644 top2 RC TR 644 top2 110-240 V AC Operating voltage 50-60 Hz Frequency 3 modules Width TR top2 DIN-rail, 3 modules, 4 modules 4 modules DIN-rail Installation type 8 years Power reserve Max. switching capacity at 250 V AC, cos φ = 1 16 A 2 x 16 A + 2 x 10 A Max. switching capacity at 250 V AC, cos φ = 0.6 10 A 2600 W Incandescent/halogen lamps approx.10 mA Min. switching capacity 1s Shortest switching time ≤ ± 0.5 s/day (Quartz) or DCF77/GPS ≤ ± 0.5 s/day (Quartz) Time accuracy ≤ ± 0.5 s/day (Quartz) or DCF77/GPS ≤ ± 0.5 s/day (Quartz) ≤ ± 0.5 s/day (Quartz) or DCF77/GPS ≤ ± 0.5 s/day (Quartz) 0.5 VA Power consumption V Test approvals IP 20 Type of protection II in accordance with EN 60 730-1 Protection class -30 °C  … +55 °C Ambient temperature Accessories OBELISK top2 PC set ■ Antenna top2 RC–DCF Art.No.: 9070409 Details Page 54 ■ ▶ ■ Antenna top2 RC-GPS for TR 641 top2 RC, TR 642 top2 RC, TR 644 top2 RC Art.No.: 9070410 Page 54 Details ■ ■ ▶ Additional accessories for TR 641 top2 RC, TR 642 top2 RC, TR 644 top2 RC Art.No.: 9070610 Page 54 Details ▶ ■ ■ ■ ■ Wall installation kit 52.5 mm Details Page 55 Front panel mounting kit Page 54 Details Wall installation kit 70 mm Page 55 Details OBELISK top2 memory card Details Page 55 ▶ ▶ ▶ ▶ Connection example TR 641 top2 RC TR 642 top2 RC L N 4 5 6 TR 644 top2 RC L N 4 C2 Ext1 Ext2 RC GPS C1 2 C4 N RC DCF Data max. 100 m max. 100 m max. 100 m max. 100 m RC GPS 1 6 10 11 12 L RC DCF Data max. 100 m max. 100 m max. 100 m RC DCF Ext1 5 C2 Ext1 Ext2 1 N L L 2 C1 3 1 N L L http Data RC GPS C1 3 Ext3 Ext4 2 C3 3 7 8 9 N L L Additional technical data at: www.theben.de/product/ Article number Catalogue_ZEIT_GB_2010.indd 21 21 24.03.10 12:05 Digital time switches TIME DIN-rail, 4 modules, 3 modules EXTENSION TimeDigital time switchesDIN-rail, 4 modules, 3 modules Extension modules EM 4 top2 EM LAN top2 Description EM 4 top2 ■ ■ ■ ■ ■ ■ ■ ■ Extension module for TR 641 top2 RC, TR 642 top2 RC and TR 644 top2 RC 4 channels Width: 4 modules DuoFix spring terminals 4 external inputs Switching preselection Permanent ON/OFF switching ■ 4 LEDs for displaying switching status Zero-cross switching for relay-saving switching and high lamp loads Remote programming using OBELISK top2 PC software Direct remote access to time switch (e.g. reading out switching status, performing manual switching, checking time) Width: 3 modules ■ ■ EM LAN top2 ■ Ethernet communication module for remote access via LAN-DSL network to time switches TR 641 top2 RC, TR 642 top2 RC and TR 644 top2 RC ■ Product selection Type Article number EM 4 top2 6490104* EM LAN top2 6490900* *Available July 2010 Front panel mounting kit ■ Art.No.: 9070001 Details Page 54 ▶ Connection example Additional accessories ■ ■ Wall installation kit 70 mm Details Page 55 Wall installation kit 52.5 mm Details Page 55 ▶ ▶ EM 4 top2 EM LAN top2 4 max. 100 m max. 100 m max. 100 m max. 100 m Accessories 5 6 10 11 12 L C2 C4 Ext1 Ext2 Ext3 Ext4 C1 1 2 L N Data C3 3 7 8 9 N L L 22 Catalogue_ZEIT_GB_2010.indd 22 N Data N L http Additional technical data at: www.theben.de/product/ Article number 24.03.10 12:05 Digital time switches TIME Wall installation/3-point mounting TimeDigital time switchesWall installation/3-point mounting Description ■ ■ ■ ■ ■ ■ ■ Digital tariff time switch with weekly program 2 channels Text-oriented user guidance in the display 42 memory locations 6 year power reserve (exchangeable lithium battery) ON-OFF switching times Switching preselection ■ ■ ■ ■ ■ ■ Permanent ON/OFF switching PIN coding Holiday program Display and control panel can be turned by 90° Control LED for battery change Automatic summer/winter time changeover TR top TR 685/2 top Product selection Program Number of channels Memory locations Programfunctions Operating voltage Type Article number Weekly program 2 42 ON/OFF 110 /230 V AC TR 685/2 top 6850012 Technical data TR 685/2 top 110-230 V AC Operating voltage 50-60 Hz Frequency 6 years Power reserve Max. switching capacity at 250 V AC, cos φ = 1 8A Max. switching capacity at 250 V AC, cos φ = 0.6 2A ≤ ± 0.25 s/day(Quartz) Time accuracy 10 VA Power consumption IP 54 Type of protection II in accordance with EN 62,054-21 Protection class -25 °C … +55 °C Ambient temperature Scale drawings Connection example TR 685/2 top TR 685/2 top 74 175 121,5 6,5 105 1 min Shortest switching time 230V~ 110V~ 1 2 1a 3 C1 4 C2 5 6 7 8 N L L 84,5 101,5 http Additional technical data at: www.theben.de/product/ Article number Catalogue_ZEIT_GB_2010.indd 23 23 24.03.10 12:05 Digital time switches TIME Front panel installation/wall installation TimeDigital time switchesFront panel installation/wall installation TR top Digital time switches – wall installation TR 635 top TR 636 top Description Common functions ■ ■ ■ ■ ■ ■ Digital time switch with weekly program Text-oriented user guidance in the display 42 memory locations 10 year power reserve (lithium battery) ON-OFF switching times ■ ■ ■ ■ ■ ■ Pulse program Cycle program Switching preselection Permanent ON/OFF switching Holiday program Random program PIN coding ■ Automatic summer/winter time changeover TR 635 top ■ 1 channel TR 636 top ■ 2 channels Product selection Program Number of channels Memory locations 1 42 2 42 Weekly program 24 Catalogue_ZEIT_GB_2010.indd 24 Programfunctions ON/OFF, Pulse, Cycle ON/OFF, Pulse, Cycle Operating voltage Type Article number 230-240 V AC TR 635 top 6350002 230-240 V AC TR 636 top 6360002 http Additional technical data at: www.theben.de/product/ Article number 24.03.10 12:05 Digital time switches TIME Front panel installation/wall installation TR 635 top TR 636 top 230-240 V AC Operating voltage 50-60 Hz Frequency Front panel installation/wall installation Installation type 10 years Power reserve Max. switching capacity at 250 V AC, cos φ = 1 16 A 6A Max. switching capacity at 250 V AC, cos φ = 0.6 10 A 6A 2300 W Incandescent/halogen lamps 1200 W 1s Shortest switching time ≤ ± 1 s/day(Quartz) Time accuracy 6 VA Power consumption 8 VA Test approvals V Type of protection IP 20 II in accordance with EN 60 730-1 Protection class -10 °C  … +55 °C Ambient temperature Accessories Scale drawings Quick fastening 72 x 72 TR 635 top, TR 636 top ■ TR top Technical data Art.No.: 9070071 Details Page 55 ▶ 69 54 16 104 72  66 72 65 25 Connection example TR 635 top TR 636 top C1 1 2 C1 3 7 1 8 2 C2 3 4 N L L 5 6 7 8 N L L http Additional technical data at: www.theben.de/product/ Article number Catalogue_ZEIT_GB_2010.indd 25 25 24.03.10 12:05 Digital time switches TIME Flush-mounted TimeDigital time switchesFlush-mounted TR top TR 030 top Description Digital time switch with weekly program 1 channel Text-oriented user guidance in the display 42 memory locations 10 year power reserve (lithium battery) ON-OFF switching times Pulse program Cycle program ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Switching preselection Permanent ON/OFF switching Holiday program Random program PIN coding Automatic summer/winter time changeover Product selection Program Number of channels Memory locations Weekly program 1 42 Programfunctions ON/OFF Pulse, Cycle Operating voltage Type Article number 230 V AC TR 030 top 0300002 Technical data TR 030 top 230 V AC Operating voltage 50 Hz Frequency Flush-mounted wall installation Installation type 10 years Power reserve Max. switching capacity at 250 V AC, cos φ = 1 10 A Max. switching capacity at 250 V AC, cos φ = 0.6 10 A ≤ ± 1 s/day(Quartz) Time accuracy Power consumption 6 VA Test approvals V Type of protection IP 20 II in accordance with EN 60 730-1 Protection class -10 °C … +35 °C Ambient temperature 2300 W Incandescent/halogen lamps Scale drawings Connection example TR 030 top TR 030 top  84 C1 6,5 L 17 N 48 Catalogue_ZEIT_GB_2010.indd 26 1 2 3 N L L 50 26 1s Shortest switching time http weitere technische Daten unter: www.theben.de/produkt/ Artikel-Nr. 24.03.10 12:05 Digital time switches TIME Flush-mounted TimeDigital time switchesPlug-in theben-eltimo 020 S Description Common functions ■ ■ ■ ■ ■ ■ ■ ■ Digital plug-in timer with weekly program Use with earthed sockets (additional socket types upon request) 1 channel Easy operation via keys for program function and day of the week, hours and minutes ON-OFF switching times Switching preselection Permanent ON/OFF switching ■ Random program Automatic summer/winter time changeover ELTIMO Digital plug-in timers theben-eltimo 020 S ■ 36 memory locations theben-eltimo 020 S DCF ■ ■ DCF radio control 33 memory locations Product selection Program Number of channels Weekly program 1 Memory locations Time based on Operating voltage Type Article number 36 Quartz 230 V AC theben-eltimo 020 S 0200000 33 Quartz/DCF77 230 V AC theben-eltimo 020 S DCF 0200300 Technical data theben-eltimo 020 S theben-eltimo 020 S DCF 230 V AC Operating voltage 50 Hz Frequency Socket (plug-in) Installation type 20 days Power reserve Max. switching capacity at 250 V AC, cos φ = 1 16 A Max. switching capacity at 250 V AC, cos φ = 0.6 2A 3500 W Incandescent/halogen lamps 1 min Shortest switching time ≤ ± 1 s/day (Quartz) Time accuracy ≤ ± 1 s/day (Quartz) or DCF77 synchronous Power consumption 5 VA Type of protection IP 20 II for housing, I for plug system as per EN 62 730-1 Protection class -10 °C … +40 °C Ambient temperature Scale drawings theben-eltimo 020 S, theben-eltimo 020 S DCF 64,8 129,4 41,3 101,9 55 http weitere technische Daten unter: www.theben.de/produkt/ Artikel-Nr. Catalogue_ZEIT_GB_2010.indd 27 27 24.03.10 12:05 TIME 28 Catalogue_ZEIT_GB_2010.indd 28 http weitere technische Daten unter: www.theben.de/produkt/ Artikel-Nr. 24.03.10 12:05 TIME Analogue time switches Section overview Program Number of channels Type of contact Power reserve Shortest switching time Programmable every Connection type Type Daily program 1 NO contact Weekly program 1 NO contact 60 minute program 1 changeover contact Daily program 1 changeover contact Weekly program 1 changeover contact 1 changeover contact 2 Page – 15 min 15 min Screw terminals SYN 160 a 32 3 days 15 min 15 min Screw terminals SUL 180 a 32 3 days 2h 2h Screw terminals MEM 190 a 32 – 37.5 s 37.5 s Spring terminals SYN 151 h 36 – 15 min 15 min Spring terminals SYN 161 d 36 200 hours 15 min 15 min Spring terminals SUL 181 d 36 200 hours 2h 2h Spring terminals SUL 191 w 36 – 20 min/2 h 5 min, 30 min Screw terminals SYN 269 h 42 2 changeover contacts – 20 min/2 h 5 min, 30 min Screw terminals SYN 269 g 42 1 changeover contact 3 days 20 min/2 h 5 min, 30 min Screw terminals SUL 289 h 42 2 2 changeover contacts 3 days 20 min/2 h 5 min, 30 min Screw terminals SUL 289 g 42 60 minute program 1 changeover contact – 1.25 min 18.5 s Screw terminals TM 179 h 44 Daily program and 1/2 day OFF function 1 changeover contact 3 days 30 min/12 h 15 min/12 h Screw terminals SUL 189 hw 44 – 15 min 15 min Screw terminals SYN 169 s 46 Daily program 1 changeover contact 3 days 15 min 15 min Screw terminals SUL 189 s 46 DIN rail, 1 module DIN rail, 3 modules Front panel/wall installation Daily program Wall installation/3-point mounting 1 changeover contact 6 days 20 min 5 min Screw terminals SUL 285/1 T 48 2 2 changeover contacts 6 days 20 min 5 min Screw terminals SUL 285/2 T 48 Daily program 1 NO contact – 15 min 15 min Socket intermedi- theben timer 26 ate connector theben-timer 26 IP 44 Weekly program 1 NO contact – 2h 2h Socket intermediate connector theben timer 27 50 1 changeover contact – 2 min/1 h 1 min/1 h Screw terminals FRI 77 h 52 2 2 changeover contacts – 2 min/1 h 1 min/1 h Screw terminals FRI 77 g 52 1 changeover contact – 2 min/1 h 1 min/1 h Screw terminals FRI 77 h-2 52 2 2 changeover contacts – 2 min/1 h 1 min/1 h Screw terminals FRI 77 g-2 52 Daily program Socket (plug-in) 50 50 Wall-mounted Daily and defrost program Quick fastening for DIN rail Daily and defrost program 29 Catalogue_ZEIT_GB_2010.indd 29 24.03.10 12:05 Time switches with segments SYN, SUL, MEM DIN-rail installation TIME 16 Amperes time switch, Small yet powerful 30 Catalogue_ZEIT_GB_2010.indd 30 24.03.10 12:05 Time switches with segments TIME Please pre-heat! In many industrial production plants pre-heating phases are an absolute necessity, e. g. with packaging or injection moulding machines in electronics production. Time switches accurately and reliably ensure that the plants are pre-heated before production starts and that the production process can proceed without delays. Narrow and compact – the tried and tested time switch all-rounder for every application. With SYN, SUL or MEM you can control time, regardless of what has to be controlled, aquarium light, circulation pump or illuminated advertising. STRAIGHTFORWARD SEGMENT PROGRAMMING The 15 minute segments provide fast and accurate setting of the desired time program. SOLID TERMINALS DESPITE THE MOST NARROW OF DESIGNS They ensure the secure connection of the consumer by wire or strand even if 2 wires have to attached per terminal. EXCHANGEABLE BATTERY CELL The Button Battery Cell provides reliability in the event of power loss, e.g. Power off during maintainance work, so that there is no need to reset the timer. SIMPLE RETROFITTING The right terminal cover with screw fixings ensures secure installation during modernisation work and this is naturally sealable. SYN, SUL, MEM DIN-rail installation SEALABLE COVER FLAPS This protects the switching program from being changed by unauthorised users THREE POSITION MANUAL SWITCH FOR CONTINUOUS ON/OFF The switching program can be turned off at any time if required, e. g. During holiday time. 31 Catalogue_ZEIT_GB_2010.indd 31 24.03.10 12:05 Analogue time switches TIME SYN, SUL, MEM DIN-rail, 1 module TimeAnalogue time switchesDIN-rail, 1 module Analogue time switches – 1 module – switching segments SYN 160 a SUL 180 a MEM 190 a Description Common functions ■ ■ ■ ■ ■ Analogue time switch 1 channel Screw terminals Manual switch with 3 positions: Permanent ON/AUTO/permanent OFF Switching status display ■ ■ ■ Daily program MEM 190 a ■ ■ ■ SUL 180 a ■ As SYN 160 a, but: ■ Weekly program With power reserve (exchangeable NiMH rechargeable battery) 84 switching segments Quartz controlled Shortest switching time: 2 hours With power reserve (exchangeable NiMH rechargeable battery) Quartz controlled ■ SYN 160 a ■ Without power reserve 96 switching segments Synchronised with mains Shortest switching time: 15 minutes ■ ■ Product selection Program Number of channels Daily program 1 Weekly program 1 32 Catalogue_ZEIT_GB_2010.indd 32 Power reserve Shortest switching time Programmable every Type of contact Operating voltage Type Article number – 15 min 15 min NO contact 230 V AC SYN 160 a 1600001 3 days 15 min 15 min NO contact 230 V AC SUL 180 a 1800001 3 days 2h 2h NO contact 230 V AC MEM 190 a 1900001 http Additional technical data at: www.theben.de/product/ Article number 24.03.10 12:06 Analogue time switches TIME SYN, SUL, MEM DIN-rail, 1 module Technical data SYN 160 a Operating voltage Frequency SUL 180 a MEM 190 a 230 V AC 230-240 V AC 50 Hz 50-60 Hz 1 module Width DIN-rail Installation type Daily program Program Weekly program – Power reserve 3 days Max. switching capacity at 250 V AC, cos φ = 1 16 A Max. switching capacity at 250 V AC, cos φ = 0.6 4A Shortest switching time 15 min 2h Programmable every 15 min 2h Synchronised with mains Time accuracy ≤ ± 1 s/day(Quartz) Power consumption 1 VA Test approvals V Type of protection IP 20 II in accordance with EN 60 730-1 Protection class –25 °C … +50 °C Ambient temperature Accessories Wall installation kit 17.5 mm ■ Art.No.: 9070065 Page 55 Details ▶ –10 °C … +50 °C Connection example Front panel mounting kit ■ SYN 160 a, SUL 180 a, MEM 190 a Art.No.: 9070001 Page 54 Details ▶ C1 2 N 1 L N L L http Additional technical data at: www.theben.de/product/ Article number Catalogue_ZEIT_GB_2010.indd 33 33 24.03.10 12:06 Time switches with segments SYN and SUL DIN-rail, 1 module TIME 40% faster wiring with DuoFix spring terminals 34 Catalogue_ZEIT_GB_2010.indd 34 24.03.10 12:06 Time switches with segments TIME There is something in the air. Fresh air in offices, schools public buildings and factories is usually provided by ventilation systems. They can be controlled by a time program which guarantees a regular and controlled supply of fresh air at set times. This is proved to be beneficial in terms of health, concentration and well being, but without wasting energy. The SYN and SUL time switches from Theben have been proven a million times over and have still been improved. Precisely programmable, faster to connect and this is all "Made in Germany". 24 HR. – LINE DESCRIPTIONS Lettering on the clock face ensures that the day and night programmes are not accidentally mixed up. It is very clear when setting, when e.g. 3:00am or 3:00pm is displayed next to the hand. 15 MINUTE SEGMENTS For precise time programmes with precise 15 minute settings. 96 folding segments can be programmed in just seconds. SYN and SUL DIN-rail, 1 module DuoFix spring terminals 2 wires can be connected per terminal. Each of the wires is secured by its own spring. 40% time saved Connection is even faster thanks to DuoFix spring terminals. It is instantly wired regardless of 0.5mm2, 1.5mm2 or 2.5 mm2 wire or cable. Thanks to the integrated button, the plug-in connection to the phase tester can be easily released. PERMANENT SWITCH: ON/TIMED/OFF Manually connected consumers can be switched permanently ON or permanent OFF at any time, e.g. with pond pumps, Christmas lighting etc. SWITCHING STATUS DISPLAY AND SWITCHING PRE-SELECTION If you leave home early or come back home early – that's not a problem: One turn of the pre-selection switch and the unit is turned on or off early on time only. 35 Catalogue_ZEIT_GB_2010.indd 35 24.03.10 12:06 Analogue time switches TIME DIN-rail, 3 modules SYN und SUL TimeAnalogue time switchesDIN-rail, 3 modules Analogue time switches – 3 modules – switching segments SYN 151 h SUL 181 d SUL 191 w SYN 161 d SUL 191 w Description Common functions ■ ■ ■ ■ ■ ■ Analogue time switch 1 channel DuoFix spring terminals Switching preselection Manual switch with 3 positions: Permanent ON/AUTO/permanent OFF Switching status display ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ SYN 151 h ■ Daily program Without power reserve 96 switching segments Synchronised with mains Shortest switching time: 15 minutes Clock hands for time display and in addition 12/24 hour recognition Simple summer/winter time correction ■ 60 minute program Without power reserve 96 switching segments Synchronised with mains Shortest switching time: 37.5 seconds ■ ■ ■ ■ ■ ■ ■ SUL 181 d Weekly program With power reserve (NiMH rechargeable battery) 84 switching segments Quartz controlled Shortest switching time: 2 hours Clock hands for time display and in addition 12/24 hour recognition Simple summer/winter time correction As SYN 161 d, but: With power reserve (NiMH rechargeable battery) Quartz controlled ■ ■ Product selection Program Number of channels Power reserve Shortest switching time Programmable every 60 minute program 1 – 37.5 s 37.5 s Daily program – 15 min 15 min 1 200 hours 15 min 15 min Weekly program 1 200 hours 2h 2h 36 Catalogue_ZEIT_GB_2010.indd 36 Type of contact Changeover contact Changeover contact Changeover contact Changeover contact Operating voltage Type Article number 230 V AC SYN 151 h 1510011 230 V AC SYN 161 d 1610011 SUL 181 d 1810011 SUL 191 w 1910011 110 – 230 V AC 110 – 230 V AC http Additional technical data at: www.theben.de/product/ Article number 24.03.10 12:06 Analogue time switches TIME SYN und SUL DIN-rail, 3 modules Technical data SYN 151 h Operating voltage SYN 161 d SUL 181 d SUL 191 w 230 V AC 110-230 V AC 50 Hz 50-60 Hz Frequency 3 modules Width DIN-rail Installation type 60 minute program Program Daily program Weekly program – Power reserve Max. switching capacity at 250 V AC, cos φ = 1 200 hours 10 A 16 A Max. switching capacity at 250 V AC, cos φ = 0.6 4A Shortest switching time 37.5 s 15 min 2h Programmable every 37.5 s 15 min 2h Synchronised with mains Time accuracy ≤ ± 1 s/day(Quartz) Power consumption 1 VA Test approvals V Type of protection IP 20 II in accordance with EN 60 730-1 Protection class –20 °C … +55 °C Ambient temperature Accessories Wall installation kit 52.5 mm ■ Art.No.: 9070050 Page 55 Details ▶ Connection example Front panel mounting kit ■ SYN 151 h, SYN 161 d, SUL 181 d, SUL 191 w Art.No.: 9070001 Page 54 Details ▶ C1 1 2 3 L N N L L http Additional technical data at: www.theben.de/product/ Article number Catalogue_ZEIT_GB_2010.indd 37 37 24.03.10 12:06 Analogue time switches TIME DIN-rail, 3 modules TimeAnalogue time switchesDIN-rail, 3 modules Analogue time switches – 3 modules – tappet SUL 188 hw SUL SUL 188 g Description Common functions ■ ■ ■ ■ ■ ■ ■ SUL 188 g Analogue time switch With power reserve (NiMH rechargeable battery) Quartz controlled Tappets Screw terminals Switching status display Operating indication ■ ■ ■ ■ ■ SUL 188 hw Daily program 2 channels Fine adjustment to set the time to the minute Shortest switching time: 30 minutes 10 tappets included in delivery ■ ■ ■ ■ ■ Daily program and 1/2 day OFF function for the weekdays 1 channel (with series connection of the 2 contacts) Tappets and turning segments Shortest switching time: 45 minutes (12 hours for the 1/2 day OFF function) 6 tappets included in delivery Product selection Program Daily program Daily program and 1/2 day OFF function 38 Catalogue_ZEIT_GB_2010.indd 38 Number of channels Power reserve Shortest switching time Programmable every 2 3 days 30 min 30 min 1 3 days 45 min/12 h 45 min/12 h Type of contact Operating voltage Type Article number 2 Changeover contacts 230 V AC SUL 188 g 1880033 Changeover contact 230 V AC SUL 188 hw 1880108 http Additional technical data at: www.theben.de/product/ Article number 24.03.10 12:06 Analogue time switches TIME DIN-rail, 3 modules SUL 188 g SUL 188 hw Operating voltage 230 V AC Frequency 50-60 Hz Width 3 modules DIN-rail Installation type Daily program Program Daily program with 1/2 day OFF function 3 days Power reserve Max. switching capacity at 250 V AC, cos φ = 1 10 A Max. switching capacity at 250 V AC, cos φ = 0.6 4A Shortest switching time 30 min 45 min/12 h Programmable every 30 min 45 min/12 h ≤ ± 1 s/day(Quartz) Time accuracy Power consumption 1 VA Test approvals V Type of protection IP 20 II in accordance with EN 60 730-1 Protection class –20 °C … +55 °C Ambient temperature Accessories Terminal box cover plate 52.5 mm ■ Art.No.: 9070061 Page 54 Details ▶ SUL Technical data Connection example Front panel mounting kit ■ SUL 188 g SUL 188 hw Art.No.: 9070001 Page 54 Details ▶ C2 4 5 7d 6 7 4 C1 1 2 3 8 1 N L L http 5 6 7 3 8 24h 2 N L L Additional technical data at: www.theben.de/product/ Article number Catalogue_ZEIT_GB_2010.indd 39 39 24.03.10 12:07 Time switches with tappets SYN and SUL Front panel installation/wall mounting TIME Day or week? It's up to you. 40 Catalogue_ZEIT_GB_2010.indd 40 24.03.10 12:07 Time switches with tappets TIME At the heart of the system. Circulation pumps ensure an immediate supply of hot water from in all the water outlets in the building. Easy to use but costintensive. Energy expenditure can be significantly reduced by using timers: Programmed for the periods of highest demand, the pump only switches on, for example, in the morning and evening – an environmentally-friendly and economic solution. Switchable for daily or weekly programs. Ideal mounted timer for rental properties, e. g. with weekly program for pump control for single people or employed couples, night switch off for families with children who are at home during the day. SWITCHING THE TIME SWITCH It is very easy to switch the time switch from daily to weekly program by lifting the graduated ring. The graduated ring printed on both sides is reset here with weekly sections. The pins can now be inserted for the weekly program for the days of the week from 1– 7. SWITCHING DISPLAY AND SWITCHING PRE-SELECTION If you leave home early or come back home early – that's not a problem: One turn of the pre-selection switch and heating or lighting will switch ON or OFF early on time only. SYN and SUL Front panel installation/wall mounting FRONT PANEL INSTALLATION The device can be installed in a cut-out of 69 x 69 mm and for walls up to 19 mm thick. Connection either by terminal screws or 2.8 mm flat pins. SEMI-AUTOMATIC Thanks to flexible use of the tappet, semiautomatic function is possible, when e.g. it is switched on manually and then the OFF pins are used in the evening. PERMANENT ON/OFF Manually connected consumers can be switched permanently ON or OFF at any time, e. g. in the case of fountains, Christmas lighting etc. The existing or manually set relay status can be easily fixed by releasing the switching lever. 41 Catalogue_ZEIT_GB_2010.indd 41 24.03.10 12:07 Analogue time switches TIME Front panel installation/wall installation SYN und SUL TimeAnalogue time switchesFront panel installation/wall installation Analogue time switches – wall installation – tappet SYN 269 h SUL 289 g Description Common functions ■ ■ ■ ■ ■ ■ Analogue time switch with daily or weekly program (switching disc can be turned) Tappets Shortest switching time: 20 minutes or 2 hours Clock hands for time display Switching status display SYN 269 h ■ ■ ■ ■ ■ ■ SYN 269 g ■ ■ ■ 1 channel Without power reserve Synchronised with mains Switching preselection Permanent ON/OFF switch Simple summer/winter time correction 32 tappets included in delivery ■ 2 channels Without power reserve Synchronised with mains 49 tappets included in delivery SUL 289 h As SYN 269 h, but: ■ ■ With power reserve (NiMH rechargeable battery) Quartz controlled SUL 289 g ■ ■ ■ ■ 2 channels With power reserve (NiMH rechargeable battery) Quartz controlled 49 tappets included in delivery Product selection Program Daily program or weekly program 42 Catalogue_ZEIT_GB_2010.indd 42 Number of channels Power reserve Shortest switching time Programmable every 1 – 20 min or 2 h 5 min or 30 min 2 – 20 min or 2 h 5 min or 30 min 1 3 days 20 min or 2 h 5 min or 30 min 2 3 days 20 min or 2 h 5 min or 30 min Type of contact Changeover contact 2 Changeover contacts Changeover contact 2 Changeover contacts Operating voltage Type Article number 230 V AC SYN 269 h 2690008 230 V AC SYN 269 g 2690033 230 V AC SUL 289 h 2890008 230 V AC SUL 289 g 2890033 http Additional technical data at: www.theben.de/product/ Article number 24.03.10 12:07 Analogue time switches TIME SYN und SUL Front panel installation/wall installation Technical data SYN 269 h SYN 269 g SUL 289 h 230 V AC Operating voltage 50 Hz Frequency 50-60 Hz Front panel installation/wall installation Installation type Daily program or weekly program Program – Power reserve 3 days Max. switching capacity at 250 V AC, cos φ = 1 10 A Max. switching capacity at 250 V AC, cos φ = 0.6 2A 20 min or 2 h Shortest switching time 5 min or 30 min Programmable every Synchronised with mains Time accuracy ≤ ± 1 s/day(Quartz) Power consumption 1 VA Type of protection IP 20 II in accordance with EN 60 730-1 Protection class –10 °C … +55 °C Ambient temperature Accessories Scale drawings Quick fastening 72 x 72 SYN 269 h, SYN 269 g, SUL 289 h, SUL 289 g ■ SUL 289 g Art.No.: 9070071 Page 55 Details ▶ 69 54 16 104 65 72  66 72 25 Connection example SYN 269 h, SUL 289 h SYN 269 g, SUL 289 g C1 1 2 C1 3 7 1 8 2 C2 3 4 N L L 5 6 7 8 N L L http Additional technical data at: www.theben.de/product/ Article number Catalogue_ZEIT_GB_2010.indd 43 43 24.03.10 12:07 Analogue time switches TIME Front panel installation/wall installation TM und SUL TimeAnalogue time switchesFront panel installation/wall installation Analogue time switches – wall installation – tappets TM 179 h SUL 189 hw Description TM 179 h ■ ■ ■ ■ ■ ■ ■ ■ Analogue time switch with 60 minute program 1 channel Without power reserve Synchronised with mains Tappets Shortest switching time: 75 seconds Switching preselection ■ Switching status display 6 tappets included in delivery ■ SUL 189 hw ■ ■ ■ Analogue time switch with daily program and 1/2 day OFF function for the weekdays 1 channel (with series connection of the 2 contacts) ■ ■ ■ ■ With power reserve (NiMH rechargeable battery) Quartz controlled Tappets and turning segments Shortest switching time: 30 minutes (12 hours for the 1/2 day OFF function) Switching status display 6 tappets included in delivery Product selection Program 60 minute program Daily program and 1/2 day OFF function 44 Catalogue_ZEIT_GB_2010.indd 44 Number of channels Power reserve Shortest switching time Programmable every 1 – 1.25 min 18.5 s 1 3 days 30 min/12 h 15 min/12 h Type of contact Operating voltage Type Article number Changeover contact 230 V AC TM 179 h 1790008 Changeover contact 230 V AC SUL 189 hw 1890108 http Additional technical data at: www.theben.de/product/ Article number 24.03.10 12:07 Analogue time switches TIME TM und SUL Front panel installation/wall installation Technical data TM 179 h SUL 189 hw 230 V AC Operating voltage 50 Hz Frequency 50-60 Hz Front panel installation/wall installation Installation type Program 60 minute program Daily program with 1/2 day OFF function – 3 days Power reserve Max. switching capacity at 250 V AC, cos φ = 1 10 A Max. switching capacity at 250 V AC, cos φ = 0.6 2A 1.25 min 30 min/12 h 18.5 s 15 min/12 h Synchronised with mains ≤ ± 1 s/day(Quartz) Shortest switching time Programmable every Time accuracy Power consumption 1 VA Type of protection IP 20 II in accordance with EN 60 730-1 Protection class –10 °C … +55 °C Ambient temperature Accessories Scale drawings Quick fastening 72 x 72 TM 179 h, SUL 189 hw ■ Art.No.: 9070071 Page 55 Details ▶ 69 54 16 104 65 72  66 72 25 Connection example TM 179 h SUL 189 hw 24h C1 1 2 3 7 1 8 2 7d 3 4 N L L 5 6 7 8 N L L http Additional technical data at: www.theben.de/product/ Article number Catalogue_ZEIT_GB_2010.indd 45 45 24.03.10 12:07 Analogue time switches TIME Front panel installation/wall installation SYN und SUL TimeAnalogue time switchesFront panel installation/wall installation Analogue time switches – wall installation – switching segments SYN 169 s SUL 189 s Description Common functions ■ ■ ■ ■ ■ ■ ■ Analogue time switch with daily program 1 channel 96 switching segments Shortest switching time: 15 minutes Clock hands for time display Switching preselection ■ ■ Permanent ON/OFF switch Switching status display Simple summer/winter time correction ■ ■ ■ SYN 169 s ■ SUL 189 s With power reserve (NiMH rechargeable battery) Quartz controlled Without power reserve Synchronised with mains Product selection Program Daily program 46 Catalogue_ZEIT_GB_2010.indd 46 Number of channels Power reserve Shortest switching time Programmable every – 15 min 15 min Changeover contact 3 days 15 min 15 min Changeover contact 1 Type of contact Operating voltage Type Article number 230 V AC SYN 169 s 1690801 230 V AC SUL 189 s 1890801 110 V AC SUL 189 s 110V 1891801 http Additional technical data at: www.theben.de/product/ Article number 24.03.10 12:07 Analogue time switches TIME SYN und SUL Front panel installation/wall installation Technical data SYN 169 s SUL 189 s SUL 189 s 110V 230 V AC Operating voltage 110 V AC 50 Hz Frequency 50-60 Hz Front panel installation/wall installation Installation type Daily program Program – Power reserve 3 days Max. switching capacity at 250 V AC, cos φ = 1 10 A Max. switching capacity at 250 V AC, cos φ = 0.6 2A Shortest switching time 15 min Programmable every 15 min Synchronised with mains Time accuracy ≤ ± 1 s/day(Quartz) 1 VA Power consumption W Test approvals IP 20 Type of protection II in accordance with EN 60 730-1 Protection class –10 °C … +55 °C Ambient temperature Accessories Scale drawings Connection example Quick fastening 72 x 72 SYN 169 s, SUL 189 s SYN 169 s, SUL 189 s ■ Art.No.: 9070071 Details Page 55 ▶ 69 54 16 104 72  66 72 C1 65 25 1 2 3 7 8 N L L http Additional technical data at: www.theben.de/product/ Article number Catalogue_ZEIT_GB_2010.indd 47 47 24.03.10 12:08 Analogue time switches TIME Wall installation/3-point mounting TimeAnalogue time switchesWall installation/3-point mounting SUL 285 Analogue time switch – wall installation/3-point mounting SUL 285/1 T SUL 285/2 T Description Common functions ■ ■ ■ ■ ■ Analogue time switch with daily program With power reserve (exchangeable NiMH battery) Quartz controlled Tappets ■ ■ ■ ■ ■ Shortest switching time: 20 minutes Clock hands for time display Switching status display Simple summer/winter time correction Control LED for battery change 32 tappets included in delivery SUL 285/1 T ■ 1 channel SUL 285/2 T ■ 2 channels Product selection Program Number of channels Power reserve Shortest switching time Programmable every 1 6 days 20 min 5 min 2 6 days 20 min 5 min Daily program 48 Catalogue_ZEIT_GB_2010.indd 48 Type of contact Changeover contact 2 Changeover contacts Operating voltage Type Article number 110/230 V AC SUL 285/1 T 2850008 110/230 V AC SUL 285/2 T 2850033 http Additional technical data at: www.theben.de/product/ Article number 24.03.10 12:08 Analogue time switches TIME SUL 285 Wall installation/3-point mounting Technical data SUL 285/1 T SUL 285/2 T 110 V AC/230 V AC Operating voltage 50-60 Hz Frequency Daily program Program 6 days Power reserve Max. switching capacity at 250 V AC, cos φ = 1 6A Max. switching capacity at 250 V AC, cos φ = 0.6 2A Shortest switching time 20 min Programmable every 5 min ≤ ± 1 s/day(Quartz) Time accuracy Power consumption 1 VA Type of protection IP 54 II in accordance with EN 62,054-21 Protection class –10 °C … +55 °C Ambient temperature Scale drawings Connection example SUL 285/1 T, SUL 285/2 T SUL 285/1 T 74 175 121,5 6,5 105 SUL 285/2 T C1 1 2 1a 3 4 C1 5 N L L 84,5 101,5 http C2 L 1a N 3 4 5 6 7 8 N L L Additional technical data at: www.theben.de/product/ Article number Catalogue_ZEIT_GB_2010.indd 49 49 24.03.10 12:08 Analogue time switches TIME Plug-in Analogue socket time switches – switching segments theben-timer 26 theben-timer 27 theben-timer 26 theben-timer 27 N TIMER BE ! .4 YEAR .4 %% *AHRE ! '!2 theben-timer 26 IP 44 ¬ THE theben-timer TimeAnalogue time switchesPlug-in )%¬ ' 5 ! 2 Description Common functions ■ ■ ■ ■ ■ ■ ■ Analogue plug-in timer 1 channel Without power reserve Synchronised with mains Use with earthed sockets (additional socket types upon request) Switching preselection Switching status display ■ ■ ■ Daily program 96 switching segments Shortest switching time: 15 minutes ■ ■ ■ Weekly program 84 switching segments Shortest switching time: 2 hours theben-timer 26 IP 44 As theben-timer 26, but: ■ ■ Waterproof protection for damp locations and outdoor areas Transparent cover Product selection Program Shortest switching time Programmable every Type of contact Operating voltage Daily program 15 min 15 min NO contact 230 V AC Weekly program 2h 2h NO contact 230 V AC 50 Catalogue_ZEIT_GB_2010.indd 50 Type Article number theben-timer 26 0260030 theben-timer 26 IP 44 0260855 theben-timer 27 0270930 http Additional technical data at: www.theben.de/product/ Article number 24.03.10 12:08 Analogue time switches TIME theben-timer Plug-in Technical data theben-timer 26 theben-timer 26 IP 44 theben-timer 27 230 V AC Operating voltage 50 Hz Frequency Socket (plug-in) Installation type Daily program Program Weekly program Max. switching capacity at 250 V AC, cos φ = 1 16 A Max. switching capacity at 250 V AC, cos φ = 0.6 4A Shortest switching time 15 min 2h Programmable every 15 min 2h Synchronised with mains Time accuracy 0.8 VA Power consumption V Test approvals IP 20 Type of protection IP 44 IP 20 I in accordance with EN 60 730-1 Protection class –10 °C … +55 °C Ambient temperature Scale drawings –40 °C … +55 °C –10 °C … +55 °C Connection example 13 12 11 10 9 14 5 19 18 17 6 16 7 15 10 10 8  71 41 4 3 20 2 1 24 23 22 2 1 http Additional technical data at: www.theben.de/product/ Article number Catalogue_ZEIT_GB_2010.indd 51 51 24.03.10 12:08 Analogue time switches TIME Wall installation/DIN rail TimeAnalogue time switchesWall installation/DIN rail FRI 77 Analogue cooling timers - tappets FRI 77 h FRI 77 g-2 Description Common functions ■ ■ ■ ■ ■ FRI 77 h Analogue cooling timer with daily and short time program for defrosting Tappets Synchronised with mains Shortest switching time: 2 minutes / 1 hour 2 separate switching discs ■ ■ ■ FRI 77 h-2 1 channel Wall-mounted 6 tappets included in delivery FRI 77 g ■ ■ ■ ■ ■ 1 channel Drive with quick fastening for DIN rail ■ 6 tappets included in delivery ■ 2 channels Wall-mounted 8 tappets included in delivery Optional delayed switching on of fan FRI 77 g-2 As FRI 77 g, but: ■ Drive with quick fastening for DIN rail Product selection Type of contact Installation type Shortest switching time Programmable every Operating voltage Type Article number Changeover contact Wall-mounted 2 min/1 h 1 min/1 h 230 V AC FRI 77 h 0770008 2 Changeover contacts Wall-mounted 2 min/1 h 1 min/1 h 230 V AC FRI 77 g 0770033 2 min/1 h 1 min/1 h 230 V AC FRI 77 h-2 0770802 2 min/1 h 1 min/1 h 230 V AC FRI 77 g-2 0770832 Changeover contact 2 Changeover contacts 52 Catalogue_ZEIT_GB_2010.indd 52 Drive with quick fastening for DIN rail Drive with quick fastening for DIN rail http Additional technical data at: www.theben.de/product/ Article number 24.03.10 12:08 Analogue time switches TIME Wall installation/DIN rail FRI 77 h FRI 77 g FRI 77 h-2 FRI 77 Technical data FRI 77 g-2 230 V AC Operating voltage 50 Hz Frequency Wall-mounted Installation type Drive with quick fastening for DIN rail Daily and defrost program Program Max. switching capacity at 250 V AC, cos φ = 1 16 A Max. switching capacity at 250 V AC, cos φ = 0.6 2.5 A Shortest switching time 2 min/1 h Programmable every 1 min/1 h Synchronised with mains Time accuracy Power consumption 2.5 VA Test approvals VW IP 20 Type of protection IP 00 II in accordance with EN 60 730-1 Protection class –10 °C … +50 °C Ambient temperature Scale drawings FRI 77 h-2, FRI 77 g-2 FRI 77 h-2, FRI 77 g-2 82 61 48 105 55 105 Connection example FRI 77 h, FRI 77 h-2 1 K1 2 3 FRI 77 g, FRI 77 g-2 7 1 8 K1 2 3 4 N L L K2 5 6 7 8 N L L http Additional technical data at: www.theben.de/product/ Article number Catalogue_ZEIT_GB_2010.indd 53 53 24.03.10 12:08 Analogue time switches ACCESSORIES Wall installation/DIN rail ACCESSORIES ACCESSORIES Description Antenna top2 RC-DCF Suitable for Type Article number TR 611 top2 RC LUNA 121 top2 RC LUNA 122 top2 RC SELEKTA 171 top2 RC TR 641 top2 RC TR 642 top2 RC TR 644 top2 RC Antenna top2 RC-DCF 9070410 TR 611 top2 RC LUNA 121 top2 RC LUNA 122 top2 RC SELEKTA 171 top2 RC TR 641 top2 RC TR 642 top2 RC TR 644 top2 RC Antenna top2 RC-GPS (Available July 2010) 9070610 ■ All DIN rail installation devices Front panel kit 9070001 ■ TR 611 top2 RC LUNA 121 top2 RC LUNA 122 top2 RC SELEKTA 171 top2 RC Power unit top2 GPS (Available July 2010) 9070892 Terminal cover 52.5 mm 9070061 OBELISK top2 PC set 9070409 ■ ■ ■ ■ Time synchronisation with DCF antennas for top2 devices Installation see DCF77 antennas ■ ■ ■ ■ ■ ■ Antenna top2 RC-GPS Worldwide time synchronisation and positioning via receiving GPS satellite signal. The antenna is connected by a 2 wire cable (max. 100 m) to Theben top2 RC devices (up to 10 devices can be connected). A top2 GPS power unit (item number 9070892) is also required when connecting to TR 611 op2 RC, LUNA 121 top2 RC, LUNA 122 top2 RC or SELEKTA 171 top2 RC devices. No additional power un it is required when connecting to TR 641 top2 RC, TR 642 top2 RC, TR 644 top2 RC devices or several devices to one antenna. Positioning is possible with TR 641 top2 RC, TR 642 top2 RC, TR 644 top2 RC and SELEKTA 171 top2 RC devices. ■ ■ ■ ■ ■ ■ ■ Front panel kit ■ ■ ■ Power unit top2 GPS ■ Front panel installation set is suitable for Theben DIN rail installation devices of 17.5 to 107.5 mm width. Walls from 1 to 5 mm thick Necessary for antennas top2 RC-GPS in combination with TR 611 top2 RC, LUNA 121 top2 RC, LUNA 122 top2 RC or SELEKTA 171 top2 RC (the power unit is not necessary when 2 or more devices are connected to the antenna) Width 2 modules (35 mm) ■ ■ ■ ■ Terminal cover 52.5 mm ■ ■ ■ ■ Terminal box cover plate for assembly, sealable ■ ■ ■ ■ ■ TM 178 h SYN 168 h SUL 188 h SUL 188 g MEM 198 h SUL 188 hw TM 171 h SYN 161 h SUL 181 h OBELISK top2 PC set ■ 54 Catalogue_ZEIT_GB_2010.indd 54 OBELISK top2 memory card, USB plug-in adapter, software Updates of existing OBELISK top2 software are available as free downloads at www.theben.de . ■ ■ ■ TR top2 LUNA top2 SELEKTA top2 http weitere technische Daten unter: www.theben.de/produkt/ Artikel-Nr. 24.03.10 12:08 Analogue time switches ACCESSORIES Description Suitable for Type Article number ■ All time switches for front panel/wall installation Quick fastening 72 x 72 9070071 ■ TR top2 LUNA top2 SELEKTA top2 Memory card OBELISK top2 9070404 All DIN rail installation devices with 1 modules width Wall mounting kit 17.5 mm 9070065 All DIN rail installation devices with 2 modules width Wall mounting kit 35 mm 9070064 All DIN rail installation devices with 3 modules width Wall mounting kit 52.5 mm 9070050 All DIN rail installation devices with 4 modules width Wall mounting kit 70 mm 9070049 Quick fastening 72 x 72 ■ Snap-on mounting for 35 mm DIN rails ■ Individual memory card Memory card OBELISK top2 ■ ■ ACCESSORIES Wall installation/DIN rail Wall mounting kit 17.5 mm ■ ■ Wall installation set for top mounting, sealable ■ Wall installation set for top mounting, sealable ■ Wall installation set for top mounting, sealable ■ Wall installation set for top mounting, sealable Wall mounting kit 35 mm ■ Wall mounting kit 52.5 mm ■ Wall mounting kit 70 mm ■ http weitere technische Daten unter: www.theben.de/produkt/ Artikel-Nr. Catalogue_ZEIT_GB_2010.indd 55 55 24.03.10 12:08 1210 We reserve the right to make technical modifications and improvements. Catalogue_ZEIT_GB_2010.indd 56 9900642 Theben AG Hohenbergstraße 32, 72401 Haigerloch, GERMANY Postfach 56, 72394 Haigerloch, GERMANY Phone +49 (0) 74 74/6 92-0 Fax +49 (0) 74 74/6 92-150 [email protected], www.theben.de 24.03.10 12:02