Transcript
english
TIME
9900642
1210
We reserve the right to make technical modifications and improvements.
Digital and analogue time switches
Catalogue_ZEIT_GB_2010.indd 1
24.03.10 12:03
TIME
2
Catalogue_ZEIT_GB_2010.indd 2
http
weitere technische Daten unter: www.theben.de/produkt/ Artikel-Nr.
1
24.03.10 12:03
TIME Digital time switches
Section overview
Program
Number of channels
Memory locations
External inputs
PC interface Memory card Connection type included
Type
Page
1
56
–
✓
–
Spring terminals
TR 610 top2
8
2
56
–
✓
–
Spring terminals
TR 612 top2
8
TR 611 top2 TR 611 top2 RC
8 10 10
DIN rail, 2 modules Weekly program
1
84
1
✓
✓
Spring terminals
84
2
✓
✓
Spring terminals
TR 622 top2
54
–
✓
–
Spring terminals
SELEKTA 170 top2
12
84
1
✓
–
Spring terminals
SELEKTA 171 top2 RC
12
2
84
2
✓
–
Spring terminals
SELEKTA 172 top2
12
1
28
–
–
–
Screw terminals
TR 610 top 24V
15
2
42
–
–
–
Screw terminals
TR 612 top 24V
15
1
28
–
–
–
Screw terminals
TR 608 top
14
Yearly program, Astronomical program
1
800
1
✓
2
800
2
✓
–
–
–
–
–
Yearly program, Astronomical program
4
800
4
✓
–
4
–
4
2
42
1
2 Weekly program, Astronomical program Weekly program
1
DIN rail, 1 module Weekly program
DIN rail, 3 modules –
Spring terminals
TR 641 top2
20
✓
Spring terminals
TR 641 top2 RC
20
–
Spring terminals
TR 642 top2
20
✓
Spring terminals
TR 642 top2 RC
20
–
Spring terminals
EM LAN top2
22
–
Spring terminals
TR 644 top2
20
✓
Spring terminals
TR 644 top2 RC
20
–
–
Spring terminals
EM 4 top2
22
–
–
–
Screw terminals
TR 685/2 top
23
42
–
–
–
Screw terminals
TR 635 top
24
2
42
–
–
–
Screw terminals
TR 636 top
24
Weekly program
1
42
–
–
–
Screw terminals
TR 030 top
26
Weekly program
36
–
–
–
Plug-in
theben-eltimo 020 S
27
1
33
–
–
–
Plug-in
theben-eltimo 020 S DCF
27
DIN rail, 4 modules
Wall installation/3-point mounting Weekly program
Front panel/wall installation Weekly program
Flush-mounted
Socket (plug-in)
http
weitere technische Daten unter:
15.03.2010
Catalogue_ZEIT_GB_2010.indd 3
www.theben.de/produkt/ Artikel-Nr.
3
24.03.10 12:03
Digital time switches
TIME
TR 611 top2
DIN-rail installation
Everything top: Programming with operator guidance
Precise programming, every second Daily and weekly program
4
Catalogue_ZEIT_GB_2010.indd 4
24.03.10 12:03
Digital time switches
TIME
Long Breals, Small Cost. Of course students, employers and workers need breaks. Theben digital timers control the signals that mark the start and end of breaks - reliably and to the second. They are quick and easy to set up via text guidance on the timer, OBELISK top2 memory card, or with complex programs that can be used from the comfort of your desk via drag and drop OBELISK top2 software.
TR 611 top2
DIN-rail installation
DCF77 Step by step text guidance in illuminated screen makes programming fun even in the darkest cellars.
QUICK SETTING Thanks to Theben's ingenious copier function, weekly program settings are even easier to set. Additional days of the week with the same switching times can be copied using the OK button.
EXACT CONTROL Time signals and cycle switching times (PULSE/PAUSE) can be quickly and easily programmed at the required time.
DUAL PROGRAMMING With the memory card inserted, an alternative stored program can be carried out. When the card is removed, the program stored in the time switches carries on seamlessly.
EXTERNAL CONTROL INPUT One switch or several buttons per channel can be connected to the external control input. The permanent ON, permanent OFF, switching pre-selection, sequence timer (egg timer function) and channel enabling (activation of timer) functions are available.
DCF77-/GPS RADIO CONTROL Extremely accurate timing through automatic time synchronisation with the DCF 77 time signal transmitter in Mainflingen near Frankfurt or time synchronisation with the GPS-Signal (DCF and/or GPS antenna optional)
CAN BE CONFIGURED FOR SINGLE OR DOUBLE USE Two wires can be connected per terminal. Each of the wires is secured by its own spring clamp.
5
Catalogue_ZEIT_GB_2010.indd 5
24.03.10 12:03
OBELISK top2 programming set
TIME
OBELISK top2
Programming
"Á la carte": the easy alternative
OBELISK top2* programming set for all top2 devices: TR top2 LUNA top2 SELEKTA top2
*OBELISK top2 software can be downloaded free of charge at www.theben.de
6
Catalogue_ZEIT_GB_2010.indd 6
24.03.10 12:04
OBELISK top2 programming set
TIME
Time to rinse. In restaurants, bars and clubs the regular and correct rinsing of urinals is a hygienic necessity. Here the TR 611 top2 time switch offers a water saving and costefficient solution. The rinsing cycles can be adapted to the prevailing circumstances – visitor frequency, opening hours, days of the week– and the precise, to the second, programming controls water consumption.
OBELISK top2
Programming
Day of the week Block formation UP/DOWN minute and/or second settings
Graph or table programming possible
Intuitive OBELISK top2 PC software programming with its simple drag and drop selections. This makes entering switching times as simple as editing, printing and copying. Programs are easily saved using the OBELISK memory card. Free demo software is available at www.theben.de
SPECIAL PROGRAM Insert memory card and overwrite program or perform set special program. The standard program is restored once it is removed.
COPYING FROM TIME SWITCH TO TIMER Ideal if several timers with the same program are installed, e. g. for street lighting, shopping chains, public buildings etc.
CHANGING SWITCHING TIMES By clicking the times, ± fields then appear for editing or overwriting switching times. Day of the week blocks can be changed by clicking on the ticks.
DOCUMENTATION Printing and storing on a hard drive for straightforward program changes on PC.
PROGRAM OVERVIEW It shows at a glance what the week's switching program looks like. Subsequent changes and to the minute time changes can be made at any time.
ON BUTTON Click on the program button again for the desired day of the week and pull across to the approximate time and pull down; this programs additional days for the same switching time. The program line now appears at the bottom.
7
Catalogue_ZEIT_GB_2010.indd 7
24.03.10 14:03
Digital time switches
TIME
DIN-rail, 2 modules
TimeDigital time switchesDIN-rail, 2 modules
TR top2
Digital time switches with weekly program TR 610 top2
TR 612 top2
Description Common functions ■ ■ ■ ■ ■ ■ ■ ■
■
Digital time switch with weekly program DuoFix spring terminals Text-oriented user guidance in the display 56 memory locations Interface for OBELISK top2 memory card (PC programming) 10 year power reserve (lithium battery) Zero-cross switching for relay-saving switching and high lamp loads ON-OFF switching times
■ ■ ■ ■ ■ ■
Switching preselection Permanent ON/OFF switching Integrated operating hour counter Holiday program Display backlit (can be turned off) PIN coding Automatic summer/winter time changeover
TR 610 top2 G
As TR 610 top2, but: ■
special device with extra relais (gold-bonded contacts) for switching of very low loads
TR 612 top2 ■
2 channels
TR 610 top2 ■
1 channel
Product selection Program
Programfunctions
Number of channels
1 Weekly program
Switching load < 1 mA
Operating voltage
Type
Article number
–
230 – 240 V AC
TR 610 top2
61001031)
✓
230 – 240 V AC
TR 610 top2 G
6100110
12 – 24 V UC
TR 610 top2 24V
6104100*
–
230 – 240 V AC
TR 612 top2
61201031)
12 – 24 V UC
TR 612 top2 24V
6124100*
ON/OFF 2
*Available June 2010 1) Languages: GB, E, P, F, D (other article numbers with additional languages on request)
8
Catalogue_ZEIT_GB_2010.indd 8
http
Additional technical data at: www.theben.de/product/ Article number
24.03.10 12:04
Digital time switches
TIME
Technical data TR 610 top2
TR 610 top2 G
TR 610 top2 24V
TR 612 top2
TR 612 top2 24V
12 – 24 V UC
230 – 240 V AC
12 – 24 V UC
230 – 240 V AC
Operating voltage Frequency
50-60 Hz
Width
2 modules
Installation type
DIN-rail
Power reserve
10 years
Max. switching capacity at 250 V AC, cos φ = 1
TR top2
DIN-rail, 2 modules
16 A
Max. switching capacity at 250 V AC, cos φ = 0.6
10 A
2A
2600 W
Incandescent/halogen lamps
approx.10 mA
Min. switching capacity
10 A 1400 W
2600 W
<1 mA
1400 W
approx.10 mA 1 min
Shortest switching time
≤ ± 0.5 s/day(Quartz)
Time accuracy
3 VA
Power consumption V
Test approvals
–
V
V
V
IP 20
Type of protection
II in accordance with EN 60 730-1
Protection class
–30 °C … +55 °C
Ambient temperature
Accessories Front panel mounting kit ■
Art.No.: 9070001 Details Page 54
▶
OBELISK top2 PC set ■
Art.No.: 9070409 Details Page 54
▶
OBELISK top2 memory card ■
Art.No.: 9070404 Details Page 55
Wall installation kit 35 mm ■
▶
Art.No.: 9070064 Details Page 55
▶
Connection example TR 610 top2
TR 612 top2
L N
4
5
6
L
C2
C1 1
2
C1 3
1
2
N L L
3 N N L L
http
Additional technical data at: www.theben.de/product/ Article number
Catalogue_ZEIT_GB_2010.indd 9
9
24.03.10 12:04
Digital time switches
TIME
DIN-rail, 2 modules
TimeDigital time switchesDIN-rail, 2 modules
TR top2
Digital time switches with weekly program TR 611 top2
TR 611 top2 RC
TR 622 top2
Description Common functions ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■
Digital time switch with weekly program DuoFix spring terminals Text-oriented user guidance in the display 84 memory locations Interface for OBELISK top2 memory card (PC programming) OBELISK memory card included in delivery 10 year power reserve (lithium battery) Zero-cross switching for relay-saving switching and high lamp loads ON-OFF switching times Pulse program Cycle program
■ ■ ■ ■ ■ ■ ■ ■
Switching preselection Permanent ON/OFF switching Count-down timer Integrated operating hour counter Holiday program 2 random programs Display backlit (can be turned off) PIN coding Automatic summer/winter time changeover
TR 611 top2 RC ■
■ ■
Time synchronisation option via connection of external DCF or GPS antenna (additional power unit required for GPS if only one device is connected to the antenna). 1 channel External control input
TR 622 top2 ■ ■
2 channels 2 external control inputs
TR 611 top2 ■ ■
1 channel External control input
Product selection Program
Programfunctions
Number of channels
Control inputs
Time based on
Operating voltage
Type
Article number
230 – 240 V AC
TR 611 top2
61101031)
12 – 24 V UC
TR 611 top2 24V
6114100*
230 – 240 V AC
TR 611 top2 RC
6110300
Quartz Weekly program
ON/OFF Pulse Cycle
1
1 Quartz/DCF77/ GPS
2
2
Quartz
12 – 24 V UC
TR 611 top2 RC 24V
6114300*
230 – 240 V AC
TR 622 top2
62201031)
12 – 24 V UC
TR 622 top2 24V
6224100*
*Available June 2010 Languages: GB, E, P, F, D (other article numbers with additional languages on request)
1)
10
Catalogue_ZEIT_GB_2010.indd 10
http
Additional technical data at: www.theben.de/product/ Article number
24.03.10 12:04
Digital time switches
TIME
Technical data
Operating voltage
TR 611 top2
TR 611 top2 24V
TR 611 top2 RC
TR 611 top2 RC 24V
TR 622 top2
TR 622 top2 24V
230 – 240 V AC
12 – 24 V UC
230 – 240 V AC
12 – 24 V UC
230 – 240 V AC
12 – 24 V UC
Frequency
50-60 Hz
Width
2 modules
Installation type
DIN-rail
Power reserve
10 years
Max. switching capacity at 250 V AC, cos φ = 1
16 A
Max. switching capacity at 250 V AC, cos φ = 0.6
10 A
TR top2
DIN-rail, 2 modules
2600 W
Incandescent/halogen lamps
approx.10 mA
Min. switching capacity
1s
Shortest switching time
≤ ± 0.5 s/day (Quartz) or DCF77/ GPS
≤ ± 0.5 s/day (Quartz)
Time accuracy
≤ ± 0.5 s/day (Quartz)
3 VA
Power consumption V
Test approvals
V
V
V
V
V
IP 20
Type of protection
II in accordance with EN 60 730-1
Protection class
–30 °C … +55 °C
Ambient temperature
Accessories OBELISK top2 PC set ■
OBELISK top2 memory card
Art.No.: 9070409 Details Page 54
■
▶
Art.No.: 9070404 Details Page 55
Wall installation kit 35 mm ■
▶
Additional accessories
Art.No.: 9070064 Details Page 55
■
▶
■
■
■
Front panel mounting kit Page 54 Details top2 RC–DCF antenna Details Page 54 Antenna top2 RC-GPS Page 54 Details Power unit top2 GPS Details Page 54
▶ ▶ ▶ ▶
Connection example TR 611 top2
TR 611 top2 RC L N
TR 622 top2
L N
Ext1
4
Ext1
5
6
L
C2
RC GPS
C1 1
2
max. 100 m max. 100 m
max. 100 m
max. 100 m
RC DCF RC
Ext1 Ext2
C1 3
1 N L L
2
C1 3
1 N L L
http
2
3 N N L L
Additional technical data at: www.theben.de/product/ Article number
Catalogue_ZEIT_GB_2010.indd 11
11
24.03.10 12:04
Digital time switches
TIME
DIN-rail, 2 modules
SELEKTA top2
TimeDigital time switchesDIN-rail, 2 modules
Astronomical time switches with weekly program SELEKTA 170 top2
SELEKTA 171 top2 RC
SELEKTA 172 top2
Description Common functions ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■
■
Astronomical time switch with weekly program Astronomical switching function (automatic calculation of sunrise and sunset times for the whole year) DuoFix spring terminals Text-oriented user guidance in the display Interface for OBELISK top2 memory card (PC programming) 10 year power reserve (lithium battery) Zero-cross switching for relay-saving switching and high lamp loads Calculated astronomical switching times Programmable ON-OFF switching times Switching preselection Permanent ON/OFF switching
■ ■ ■ ■
Integrated operating hour counter Holiday program Display backlit (can be turned off) PIN coding Automatic summer/winter time changeover
■
1 channel 54 memory locations
■ ■
■
84 memory locations 3 special programs with yearly date function per channel Count-down timer
As SELEKTA 170 top2, but: ■ ■
SELEKTA 171 top2 RC ■
■
SELEKTA 172 top2
SELEKTA 170 top2 ■
■
Time synchronisation via connection of external DCF or GPS antenna (additional positioning for astronomical program with GPS antenna, top2 GPS power unit required, if only one device is connected to the antenna) 1 channel External control input
■ ■ ■ ■
2 channels Channel 1 or channel 2 can also be used purely as time switch channel 2 external control inputs 84 memory locations 3 special programs with yearly date function per channel Count-down timer
Product selection Program
Special program
Number of channels
Control inputs
Time based on
–
Quartz
1
Quartz/DCF77/GPS
2
Quartz
– Weekly program, Astronomical program
1 Yearly date function
2
Operating voltage
Type
Article number
230-240 V AC
SELEKTA 170 top2
1700100
12-24 V UC
SELEKTA 170 top2 24V
1704100*
230-240 V AC
SELEKTA 171 top2 RC
1710100
12-24 V UC
SELEKTA 171 top2 RC 24V
1714100*
230-240 V AC
SELEKTA 172 top2
1720100
12-24 V UC
SELEKTA 172 top2 24V
1724100*
*Available June 2010
12
Catalogue_ZEIT_GB_2010.indd 12
http
Additional technical data at: www.theben.de/product/ Article number
24.03.10 12:04
Digital time switches
TIME
Technical data
Operating voltage
SELEKTA 170 top2
SELEKTA 170 top2 24V
SELEKTA 171 top2 RC
SELEKTA 171 top2 RC 24V
SELEKTA 172 top2
SELEKTA 172 top2 24V
230-240 V AC
12-24 V UC
230-240 V AC
12-24 V UC
230-240 V AC
12-24 V UC
2600 W
1400 W
Frequency
50-60 Hz
Width
2 modules
Installation type
DIN-rail
Power reserve
10 years
Max. switching capacity at 250 V AC, cos φ = 1
16 A
Max. switching capacity at 250 V AC, cos φ = 0.6
10 A 2600 W
Incandescent/halogen lamps
1400 W
2600 W
1400 W
SELEKTA top2
DIN-rail, 2 modules
approx.10 mA
Min. switching capacity
1 min
Shortest switching time
≤ ± 0.5 s/day (Quartz) or DCF77/GPS
≤ ± 0.5 s/day (Quartz)
Time accuracy
≤ ± 0.5 s/day (Quartz)
3 VA
Power consumption V
Test approvals
V
V
V
V
V
IP 20
Type of protection
II in accordance with EN 60 730-1
Protection class
-30 °C … +55 °C
Ambient temperature
Accessories OBELISK top2 PC set ■
OBELISK top2 memory card
Art.No.: 9070409 Details Page 54
▶
■
Wall installation kit 35 mm
Art.No.: 9070404 Details Page 55
■
▶
Additional accessories
Art.No.: 9070064 Details Page 55
■
▶
■
■
■
Front panel mounting kit Page 54 Details antenna top2 RC–DCF Details Page 54 Antenna top2 RC-GPS Page 54 Details Power unit top2 GPS Details Page 54
▶ ▶ ▶ ▶
Connection example SELEKTA 170 top2
L
SELEKTA 171 top2 RC
N
L
SELEKTA 172 top2
4
N
Ext1
max. 100 m
Data
RC DCF
1
2
1 N L L
2
L
C1 1
3 N L L
http
6
Ext1 Ext2
RC GPS
C1 3
max. 100 m max. 100 m
– +
C1
5 C2
2
3 N N L L
Additional technical data at: www.theben.de/product/ Article number
Catalogue_ZEIT_GB_2010.indd 13
13
24.03.10 12:04
Digital time switches
TIME
DIN-rail, 1 module
TimeDigital time switchesDIN-rail, 1 module
TR top
TR 608 top Description Digital time switch with weekly program 1 channel Screw terminals Text-oriented user guidance in the display 28 memory locations 3 year power reserve (exchangeable lithium battery)
■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■
ON-OFF switching times Switching preselection Permanent ON/OFF switching PIN coding Automatic summer/winter time changeover
Product selection Program
Number of channels
Memory locations
Programfunctions
Operating voltage
Type
Article number
Weekly program
1
28
ON/OFF
230 V AC
TR 608 top
6080002
Technical data TR 608 top Operating voltage
230 V AC
Incandescent/halogen lamps
Frequency
50-60 Hz
Shortest switching time
Width
1 module
Time accuracy
1000 W 1 min ≤ ± 1 s/day(Quartz)
Installation type
DIN-rail
Power consumption
Power reserve
3 years
Test approvals
V
Type of protection
IP 20
Max. switching capacity at 250 V AC, cos φ = 1
16 A
Max. switching capacity at 250 V AC, cos φ = 0.6
6A
Wall installation kit 17.5 mm
Art.No.: 9070065 Page 55 Details
▶
II in accordance with EN 60 730-1
Protection class
–10 °C … +55 °C
Ambient temperature
Accessories
■
2.5 VA
Connection example Front panel mounting kit ■
Art.No.: 9070001 Page 54 Details
▶
TR 608 top
L
N
C1 1
2
3 N L L
14
Catalogue_ZEIT_GB_2010.indd 14
http
Additional technical data at: www.theben.de/product/ Article number
24.03.10 12:04
Digital time switches
TIME
DIN-rail, 1 module
TimeDigital time switchesDIN-rail, 2 modules
TR top
Digital time switches with weekly program – 110–120 V AC/12–24 V UC Description Digital time switch with weekly program Screw terminals Text-oriented user guidance in the display 10 year power reserve (lithium battery) ON-OFF switching times Switching preselection Permanent ON/OFF switching PIN coding Automatic summer/winter time changeover
■ ■ ■ ■ ■ ■ ■ ■ ■
TR 610 top 120V/24V ■ ■
1 channel 28 memory locations
TR 612 top 120V/24V ■ ■
2 channels 42 memory locations
Product selection Program
Number of channels
Memory locations
1
Programfunctions
28
Weekly program
ON/OFF 2
42
Operating voltage
Type
Article number
–
110 – 120 V AC
TR 610 top 120V
6101814
–
12 – 24 V UC
TR 610 top 24V
6104002
✓
110 – 120 V AC
TR 610 top 120V
6101814
–
110 – 120 V AC
TR 612 top 120V
6121814
–
12 – 24 V UC
TR 612 top 24V
6124002
Technical data TR 610 top 120V/24 V, TR 612 top 120V/24V 110-120 V AC/12-24 V UC
Operating voltage Frequency
50-60 Hz
Shortest switching time
Width
2 modules
Time accuracy
Installation type
DIN-rail
Power reserve
10 years
Max. switching capacity at 250 V AC, cos φ = 1
16 A
Max. switching capacity at 250 V AC, cos φ = 0.6
10 A
Wall installation kit 35 mm
Art.No.: 9070064 Page 55 Details
▶
1 min ≤ ± 1 s/day(Quartz) 6 VA
Power consumption
VW
Test approvals Protection rating
IP 20
Protection class
II in accordance with EN 60 730-1
Ambient temperature
–10 °C … +55 °C
Connection example
Accessories
■
1150 W
Incandescent/halogen lamps
Front panel mounting kit ■
TR 610 top 120V
Art.No.: 9070001 Page 54 Details
▶
TR 612 top 120V
L N
4
5
6
L
C2
C1 1
2
C1 3
1 N L L
http
2
3 N N L L
Additional technical data at: www.theben.de/product/ Article number
Catalogue_ZEIT_GB_2010.indd 15
15
24.03.10 12:04
Digital yearly time switches
TR 644 top2 RC
TR top2
TIME
Yearly time switches with GPS and 4 channel extension
16
Catalogue_ZEIT_GB_2010.indd 16
24.03.10 12:04
Digital yearly time switches
TIME
Annual and Astronomical Programs: If the switching channel is operated with an astronomical program, then the digital time switch calculates the sunrise and sunset times for each day of the year. As these vary according to location and time zone, the location coordinates, consisting of longitude and latitude, time zone and the current date, are required to perform the calculation. The lighting connected to the timer is switched on to the minute in the evening and off again in the morning, based on the calculated times.
TR 644 top2 RC
TR top2
C1 C2
The simple annual program can be upgraded and optimised with diverse additional functions. Holiday and bank holiday programmes as well as break signals or various programmes for lighting, heating, ventilation and air conditioning are viable for every season. ASTRO FUNCTION The astronomical program, in addition to the time switch program, switches to sunrise and sunset times depending on the season and location. Offset for taking into account remaining light after sunset or mountain shadows. Easy set-up using city databases with stored coordinates.
Zero cross switching
LAN LAN module enables direct remote access via LAN network or the internet on the time switch. Furthermore, remote reading of the switching program and remote programming is possible. COPY The same program can be saved on several clocks in a flash with an insert able memory card, even without software. The annual clock program is copied on the inserted memory card and can then be copied onto as many clocks as needed and also used as a back-up copy of the program.
EXTENSION Extension devices can be connected to the data bus. 4 channel upgrade module EM 4 top2 enables upgrading to 5, 6 and/or 8 channels.
DUAL PROGRAMMING In schools and gyms, e.g. occupancy changes often occur. No problem - an adjusted program on the memory card can be inserted in the time switch. If the old program is needed once more, then just remove the memory card.
DCF77/GPS Time synchronisation via connection of external DCF77 or GPS antennas. Additional positioning required for astronomical program with GPS.
SIMULATION IN DISPLAY Simulation takes into account priority levels, bank holidays and holiday times of individual programmes and displays the switch times on all channels.
INPUT External button/switch input per channel for easy pre-selection switch, lapsed time counter or permanent ON and/or OFF switching. SERVICE Integrated elapsed time counter separate for each channel with reset option available. Additional service function for monitoring maintenance intervals e.g for light sources. TERMINALS Duo Fix spring terminal for 2 conductor, wire or cable. In this case, each wire is held by its own DuoFix screwless terminals. ZERO-CROSS SWITCHING Zero-cross switching enables the switching of higher motor and lamp loads and extends the life of the builtin relay and lamps being switched.
17
Catalogue_ZEIT_GB_2010.indd 17
24.03.10 12:04
Digital time switches
OBELISK top2
Programming
TIME
Intuitive programming on PC
18
Catalogue_ZEIT_GB_2010.indd 18
24.03.10 12:04
Digital time switches
TIME
OBELISK top2 programming set for TR top2, LUNA top2 and SELEKTA top2. Suitable for PC operating systems Windows/XP, VISTA and WINDOWS 7. Connection via USB interface. Delivery includes OBELISK CD, programming adapter, USB cable and OBELISK memory card.
SOFTWARE OBELISK top2, intuitively operable Software for 19 different Theben devices, from a twilight switch to an astronomical switch as well as weekly and annual time switches. That means no rethinking, because the programming principle is the same for all devices that naturally saves time and money.
OFFSET AND ASTRO-IMPULSE The offset function enables individual adjustment of astronomical times up to +- 120 min. This correction factor enables adjustment for e.g. valleys where the sun sets earlier. Energy can be saved by turning lighting on later and off earlier. The power-on time can be individually determined with the Astro-Impulse.
PROGRAM Annual clock with basic weekly program and 14 different weekly programs with priority levels and date ranges. In addition to switching times, impulse and cyclical switching times are programmable as well.
PUBLIC HOLIDAYS Public holidays do not have to be programmed individually, because legal public holidays have already been sorted by country and state in OBELISK top2 database. Annual reprogramming of public holidays is no longer necessary, because public holidays are automatically updated to the correct date for the following year.
ASTRO PROGRAMM Many functions within a building need to be controlled depending upon sunrise and sunset times. Since this occurs at different times depending on the season, an astronomical program is required. It takes the geographical location in the calculation into account as well, so that the clock switches directly to sunrise and sunset times. Location input is simple via the city database or naturally by entering the longitude and latitude.
OPERATING HOURS Even operating hour monitoring of each channel and maintenance interval displayed for the user is already integrated into the time switch. A signal is sent via a common switch channel of when maintenance is required. Manual switching by the user via external buttons/ switches is possible at any time and is included in the operating hours.
OBELISK top2
Programming
SIMULATION ON THE PC Simulation takes into account priority levels, bank holidays, astronomical times and holiday times of individual programmes and displays the switch times on all channels. Every short impulse can be checked via the scroll and zoom function. REMOTE MAINTENANCE The customer can change the program with the LAN interface module from their desk - this saves driving expenses and allows for fast service. Users can also use remote software operation via the network or the internet. PROJECT DOCUMENTATION Every project can be saved on the PC with customer address, number, etc as well as users, who are connected to individual channels. This makes calculation and later program changes easier. The OBELISK top2 program enables smooth program documentation for the customer on paper with just a push of a button. Even data export is possible e.g. via EXCEL.
19
Catalogue_ZEIT_GB_2010.indd 19
24.03.10 12:04
Digital time switches
TIME
DIN-rail, 3 modules, 4 modules
TimeDigital time switchesDIN-rail, 3 modules, 4 modules
TR top2
Digital time switches with yearly and astronomical time program TR 641 top2
TR 642 top2 RC
TR 644 top2
Description Common functions ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■
■
Digital time switch with yearly and astronomical time program DuoFix spring terminals Text-oriented user guidance in the display 800 memory locations Interface for OBELISK top2 memory card (PC programming) 8 year power reserve (lithium battery) Zero-cross switching for relay-saving switching and high lamp loads ON-OFF switching times Pulse program Cycle program Extensive annual clock functions Astronomical time switch function (automatic calculation of sunrise and sunset times for the whole year) Switching preselection
■ ■ ■ ■ ■ ■ ■
Permanent ON/OFF switching Count-down timer Integrated operating hour counter Holiday program 2 random programs Display backlit (can be turned off) PIN coding Automatic summer/winter time changeover
■ ■
TR 642 top2 ■ ■
■ ■
As TR 641 top2 RC, but: ■
1 channel External control input
■ ■
2 channels 2 external control inputs
TR 644 top2 ■
TR 641 top2 RC ■
2 channels 2 external control inputs
TR 642 top2 RC
■
TR 641 top2
Extension module can be connected OBELISK memory card included in delivery
■
Time synchronisation via connection of external DCF or GPS antenna (additional positioning for astronomical program with GPS antenna) 1 channel External control input
4 channels 4 external control inputs
TR 644 top2 RC
As TR 641 top2 RC, but: ■ ■
4 channels 4 external control inputs
Product selection Program
Number of channels
Control inputs
1
1
Yearly program, Astronomical program
2
2
4
4
Time based on
Memory card included
Quartz
–
Quartz/DCF77/GPS
✓
Quartz
–
Quartz/DCF77/GPS
✓
Program functions
ON/OFF Pulse Cycle
Operating voltage
Type
Article number
110-240 V AC
TR 641 top2
6410100*
110-240 V AC
TR 641 top2 RC
6410300*
110-240 V AC
TR 642 top2
6420100*
110-240 V AC
TR 642 top2 RC
6420300*
Quartz
–
110-240 V AC
TR 644 top2
6440100*
Quartz/DCF77/GPS
✓
110-240 V AC
TR 644 top2 RC
6440300*
*Available July 2010
20
Catalogue_ZEIT_GB_2010.indd 20
http
Additional technical data at: www.theben.de/product/ Article number
24.03.10 12:04
Digital time switches
TIME
Technical data TR 641 top2 RC
TR 641 top2
TR 642 top2 RC
TR 642 top2
TR 644 top2 RC
TR 644 top2
110-240 V AC
Operating voltage
50-60 Hz
Frequency 3 modules
Width
TR top2
DIN-rail, 3 modules, 4 modules
4 modules DIN-rail
Installation type
8 years
Power reserve Max. switching capacity at 250 V AC, cos φ = 1
16 A
2 x 16 A + 2 x 10 A
Max. switching capacity at 250 V AC, cos φ = 0.6
10 A 2600 W
Incandescent/halogen lamps
approx.10 mA
Min. switching capacity
1s
Shortest switching time ≤ ± 0.5 s/day (Quartz) or DCF77/GPS
≤ ± 0.5 s/day (Quartz)
Time accuracy
≤ ± 0.5 s/day (Quartz) or DCF77/GPS
≤ ± 0.5 s/day (Quartz)
≤ ± 0.5 s/day (Quartz) or DCF77/GPS
≤ ± 0.5 s/day (Quartz)
0.5 VA
Power consumption
V
Test approvals
IP 20
Type of protection
II in accordance with EN 60 730-1
Protection class
-30 °C … +55 °C
Ambient temperature
Accessories OBELISK top2 PC set ■
Antenna top2 RC–DCF
Art.No.: 9070409 Details Page 54
■
▶
■
Antenna top2 RC-GPS
for TR 641 top2 RC, TR 642 top2 RC, TR 644 top2 RC Art.No.: 9070410 Page 54 Details
■ ■
▶
Additional accessories
for TR 641 top2 RC, TR 642 top2 RC, TR 644 top2 RC Art.No.: 9070610 Page 54 Details
▶
■
■
■
■
Wall installation kit 52.5 mm Details Page 55 Front panel mounting kit Page 54 Details Wall installation kit 70 mm Page 55 Details OBELISK top2 memory card Details Page 55
▶ ▶ ▶ ▶
Connection example TR 641 top2 RC
TR 642 top2 RC L
N
4
5
6
TR 644 top2 RC L
N
4
C2
Ext1 Ext2
RC GPS
C1 2
C4
N
RC DCF
Data
max. 100 m max. 100 m max. 100 m max. 100 m
RC GPS
1
6 10 11 12 L
RC DCF
Data
max. 100 m max. 100 m
max. 100 m
RC DCF Ext1
5 C2
Ext1 Ext2
1 N L L
2
C1
3
1
N L L
http
Data
RC GPS
C1 3
Ext3 Ext4
2
C3 3 7
8
9 N L L
Additional technical data at: www.theben.de/product/ Article number
Catalogue_ZEIT_GB_2010.indd 21
21
24.03.10 12:05
Digital time switches
TIME
DIN-rail, 4 modules, 3 modules
EXTENSION
TimeDigital time switchesDIN-rail, 4 modules, 3 modules
Extension modules EM 4 top2
EM LAN top2
Description EM 4 top2 ■ ■ ■ ■ ■ ■ ■
■
Extension module for TR 641 top2 RC, TR 642 top2 RC and TR 644 top2 RC 4 channels Width: 4 modules DuoFix spring terminals 4 external inputs Switching preselection Permanent ON/OFF switching
■
4 LEDs for displaying switching status Zero-cross switching for relay-saving switching and high lamp loads
Remote programming using OBELISK top2 PC software Direct remote access to time switch (e.g. reading out switching status, performing manual switching, checking time) Width: 3 modules
■ ■
EM LAN top2 ■
Ethernet communication module for remote access via LAN-DSL network to time switches TR 641 top2 RC, TR 642 top2 RC and TR 644 top2 RC
■
Product selection Type
Article number
EM 4 top2
6490104*
EM LAN top2
6490900*
*Available July 2010
Front panel mounting kit ■
Art.No.: 9070001 Details Page 54
▶
Connection example Additional accessories ■
■
Wall installation kit 70 mm Details Page 55 Wall installation kit 52.5 mm Details Page 55
▶ ▶
EM 4 top2
EM LAN top2 4
max. 100 m max. 100 m max. 100 m max. 100 m
Accessories
5
6 10 11 12 L
C2
C4
Ext1 Ext2
Ext3 Ext4
C1 1
2
L
N
Data
C3 3 7
8
9 N L L
22
Catalogue_ZEIT_GB_2010.indd 22
N
Data
N L
http
Additional technical data at: www.theben.de/product/ Article number
24.03.10 12:05
Digital time switches
TIME
Wall installation/3-point mounting
TimeDigital time switchesWall installation/3-point mounting
Description ■ ■ ■ ■ ■ ■ ■
Digital tariff time switch with weekly program 2 channels Text-oriented user guidance in the display 42 memory locations 6 year power reserve (exchangeable lithium battery) ON-OFF switching times Switching preselection
■ ■ ■ ■ ■ ■
Permanent ON/OFF switching PIN coding Holiday program Display and control panel can be turned by 90° Control LED for battery change Automatic summer/winter time changeover
TR top
TR 685/2 top
Product selection Program
Number of channels
Memory locations
Programfunctions
Operating voltage
Type
Article number
Weekly program
2
42
ON/OFF
110 /230 V AC
TR 685/2 top
6850012
Technical data TR 685/2 top 110-230 V AC
Operating voltage
50-60 Hz
Frequency
6 years
Power reserve Max. switching capacity at 250 V AC, cos φ = 1
8A
Max. switching capacity at 250 V AC, cos φ = 0.6
2A
≤ ± 0.25 s/day(Quartz)
Time accuracy
10 VA
Power consumption
IP 54
Type of protection
II in accordance with EN 62,054-21
Protection class
-25 °C … +55 °C
Ambient temperature
Scale drawings
Connection example
TR 685/2 top
TR 685/2 top 74
175
121,5
6,5
105
1 min
Shortest switching time
230V~ 110V~
1
2 1a 3
C1 4
C2 5 6
7
8 N L L
84,5 101,5
http
Additional technical data at: www.theben.de/product/ Article number
Catalogue_ZEIT_GB_2010.indd 23
23
24.03.10 12:05
Digital time switches
TIME
Front panel installation/wall installation
TimeDigital time switchesFront panel installation/wall installation
TR top
Digital time switches – wall installation TR 635 top
TR 636 top
Description Common functions ■ ■ ■ ■ ■
■
Digital time switch with weekly program Text-oriented user guidance in the display 42 memory locations 10 year power reserve (lithium battery) ON-OFF switching times
■ ■ ■ ■ ■ ■
Pulse program Cycle program Switching preselection Permanent ON/OFF switching Holiday program Random program PIN coding
■
Automatic summer/winter time changeover
TR 635 top ■
1 channel
TR 636 top ■
2 channels
Product selection Program
Number of channels
Memory locations
1
42
2
42
Weekly program
24
Catalogue_ZEIT_GB_2010.indd 24
Programfunctions ON/OFF, Pulse, Cycle ON/OFF, Pulse, Cycle
Operating voltage
Type
Article number
230-240 V AC
TR 635 top
6350002
230-240 V AC
TR 636 top
6360002
http
Additional technical data at: www.theben.de/product/ Article number
24.03.10 12:05
Digital time switches
TIME
Front panel installation/wall installation
TR 635 top
TR 636 top 230-240 V AC
Operating voltage
50-60 Hz
Frequency
Front panel installation/wall installation
Installation type
10 years
Power reserve Max. switching capacity at 250 V AC, cos φ = 1
16 A
6A
Max. switching capacity at 250 V AC, cos φ = 0.6
10 A
6A
2300 W
Incandescent/halogen lamps
1200 W 1s
Shortest switching time
≤ ± 1 s/day(Quartz)
Time accuracy 6 VA
Power consumption
8 VA
Test approvals
V
Type of protection
IP 20 II in accordance with EN 60 730-1
Protection class
-10 °C … +55 °C
Ambient temperature
Accessories
Scale drawings
Quick fastening 72 x 72
TR 635 top, TR 636 top
■
TR top
Technical data
Art.No.: 9070071 Details Page 55
▶
69 54 16
104
72
66
72
65
25
Connection example TR 635 top
TR 636 top
C1 1
2
C1 3
7
1
8
2
C2 3 4
N L L
5
6 7
8 N L L
http
Additional technical data at: www.theben.de/product/ Article number
Catalogue_ZEIT_GB_2010.indd 25
25
24.03.10 12:05
Digital time switches
TIME
Flush-mounted
TimeDigital time switchesFlush-mounted
TR top
TR 030 top Description Digital time switch with weekly program 1 channel Text-oriented user guidance in the display 42 memory locations 10 year power reserve (lithium battery) ON-OFF switching times Pulse program Cycle program
■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■
Switching preselection Permanent ON/OFF switching Holiday program Random program PIN coding Automatic summer/winter time changeover
Product selection Program
Number of channels
Memory locations
Weekly program
1
42
Programfunctions ON/OFF Pulse, Cycle
Operating voltage
Type
Article number
230 V AC
TR 030 top
0300002
Technical data TR 030 top 230 V AC
Operating voltage
50 Hz
Frequency
Flush-mounted wall installation
Installation type
10 years
Power reserve Max. switching capacity at 250 V AC, cos φ = 1
10 A
Max. switching capacity at 250 V AC, cos φ = 0.6
10 A
≤ ± 1 s/day(Quartz)
Time accuracy Power consumption
6 VA
Test approvals
V
Type of protection
IP 20 II in accordance with EN 60 730-1
Protection class
-10 °C … +35 °C
Ambient temperature
2300 W
Incandescent/halogen lamps
Scale drawings
Connection example
TR 030 top
TR 030 top
84
C1
6,5
L
17
N
48
Catalogue_ZEIT_GB_2010.indd 26
1
2
3 N L L
50
26
1s
Shortest switching time
http
weitere technische Daten unter: www.theben.de/produkt/ Artikel-Nr.
24.03.10 12:05
Digital time switches
TIME
Flush-mounted
TimeDigital time switchesPlug-in
theben-eltimo 020 S
Description Common functions ■ ■ ■ ■
■ ■ ■
■
Digital plug-in timer with weekly program Use with earthed sockets (additional socket types upon request) 1 channel Easy operation via keys for program function and day of the week, hours and minutes ON-OFF switching times Switching preselection Permanent ON/OFF switching
■
Random program Automatic summer/winter time changeover
ELTIMO
Digital plug-in timers
theben-eltimo 020 S ■
36 memory locations
theben-eltimo 020 S DCF ■ ■
DCF radio control 33 memory locations
Product selection Program
Number of channels
Weekly program
1
Memory locations
Time based on
Operating voltage
Type
Article number
36
Quartz
230 V AC
theben-eltimo 020 S
0200000
33
Quartz/DCF77
230 V AC
theben-eltimo 020 S DCF
0200300
Technical data theben-eltimo 020 S
theben-eltimo 020 S DCF 230 V AC
Operating voltage
50 Hz
Frequency
Socket (plug-in)
Installation type
20 days
Power reserve Max. switching capacity at 250 V AC, cos φ = 1
16 A
Max. switching capacity at 250 V AC, cos φ = 0.6
2A 3500 W
Incandescent/halogen lamps
1 min
Shortest switching time ≤ ± 1 s/day (Quartz)
Time accuracy
≤ ± 1 s/day (Quartz) or DCF77 synchronous
Power consumption
5 VA
Type of protection
IP 20 II for housing, I for plug system as per EN 62 730-1
Protection class
-10 °C … +40 °C
Ambient temperature
Scale drawings theben-eltimo 020 S, theben-eltimo 020 S DCF 64,8
129,4
41,3
101,9
55
http
weitere technische Daten unter: www.theben.de/produkt/ Artikel-Nr.
Catalogue_ZEIT_GB_2010.indd 27
27
24.03.10 12:05
TIME
28
Catalogue_ZEIT_GB_2010.indd 28
http
weitere technische Daten unter: www.theben.de/produkt/ Artikel-Nr.
24.03.10 12:05
TIME Analogue time switches
Section overview
Program
Number of channels
Type of contact
Power reserve
Shortest switching time
Programmable every
Connection type
Type
Daily program
1
NO contact
Weekly program
1
NO contact
60 minute program
1
changeover contact
Daily program
1
changeover contact
Weekly program
1
changeover contact
1
changeover contact
2
Page
–
15 min
15 min
Screw terminals
SYN 160 a
32
3 days
15 min
15 min
Screw terminals
SUL 180 a
32
3 days
2h
2h
Screw terminals
MEM 190 a
32
–
37.5 s
37.5 s
Spring terminals
SYN 151 h
36
–
15 min
15 min
Spring terminals
SYN 161 d
36
200 hours
15 min
15 min
Spring terminals
SUL 181 d
36
200 hours
2h
2h
Spring terminals
SUL 191 w
36
–
20 min/2 h
5 min, 30 min
Screw terminals
SYN 269 h
42
2 changeover contacts
–
20 min/2 h
5 min, 30 min
Screw terminals
SYN 269 g
42
1
changeover contact
3 days
20 min/2 h
5 min, 30 min
Screw terminals
SUL 289 h
42
2
2 changeover contacts
3 days
20 min/2 h
5 min, 30 min
Screw terminals
SUL 289 g
42
60 minute program
1
changeover contact
–
1.25 min
18.5 s
Screw terminals
TM 179 h
44
Daily program and 1/2 day OFF function
1
changeover contact
3 days
30 min/12 h
15 min/12 h
Screw terminals
SUL 189 hw
44
–
15 min
15 min
Screw terminals
SYN 169 s
46
Daily program
1
changeover contact
3 days
15 min
15 min
Screw terminals
SUL 189 s
46
DIN rail, 1 module
DIN rail, 3 modules
Front panel/wall installation
Daily program
Wall installation/3-point mounting 1
changeover contact
6 days
20 min
5 min
Screw terminals
SUL 285/1 T
48
2
2 changeover contacts
6 days
20 min
5 min
Screw terminals
SUL 285/2 T
48
Daily program
1
NO contact
–
15 min
15 min
Socket intermedi- theben timer 26 ate connector theben-timer 26 IP 44
Weekly program
1
NO contact
–
2h
2h
Socket intermediate connector
theben timer 27
50
1
changeover contact
–
2 min/1 h
1 min/1 h
Screw terminals
FRI 77 h
52
2
2 changeover contacts
–
2 min/1 h
1 min/1 h
Screw terminals
FRI 77 g
52
1
changeover contact
–
2 min/1 h
1 min/1 h
Screw terminals
FRI 77 h-2
52
2
2 changeover contacts
–
2 min/1 h
1 min/1 h
Screw terminals
FRI 77 g-2
52
Daily program
Socket (plug-in) 50 50
Wall-mounted Daily and defrost program
Quick fastening for DIN rail Daily and defrost program
29
Catalogue_ZEIT_GB_2010.indd 29
24.03.10 12:05
Time switches with segments
SYN, SUL, MEM
DIN-rail installation
TIME
16 Amperes time switch, Small yet powerful
30
Catalogue_ZEIT_GB_2010.indd 30
24.03.10 12:05
Time switches with segments
TIME
Please pre-heat! In many industrial production plants pre-heating phases are an absolute necessity, e. g. with packaging or injection moulding machines in electronics production. Time switches accurately and reliably ensure that the plants are pre-heated before production starts and that the production process can proceed without delays.
Narrow and compact – the tried and tested time switch all-rounder for every application. With SYN, SUL or MEM you can control time, regardless of what has to be controlled, aquarium light, circulation pump or illuminated advertising.
STRAIGHTFORWARD SEGMENT PROGRAMMING The 15 minute segments provide fast and accurate setting of the desired time program.
SOLID TERMINALS DESPITE THE MOST NARROW OF DESIGNS They ensure the secure connection of the consumer by wire or strand even if 2 wires have to attached per terminal.
EXCHANGEABLE BATTERY CELL The Button Battery Cell provides reliability in the event of power loss, e.g. Power off during maintainance work, so that there is no need to reset the timer.
SIMPLE RETROFITTING The right terminal cover with screw fixings ensures secure installation during modernisation work and this is naturally sealable.
SYN, SUL, MEM
DIN-rail installation
SEALABLE COVER FLAPS This protects the switching program from being changed by unauthorised users
THREE POSITION MANUAL SWITCH FOR CONTINUOUS ON/OFF The switching program can be turned off at any time if required, e. g. During holiday time.
31
Catalogue_ZEIT_GB_2010.indd 31
24.03.10 12:05
Analogue time switches
TIME
SYN, SUL, MEM
DIN-rail, 1 module
TimeAnalogue time switchesDIN-rail, 1 module
Analogue time switches – 1 module – switching segments SYN 160 a
SUL 180 a
MEM 190 a
Description Common functions ■ ■ ■ ■ ■
Analogue time switch 1 channel Screw terminals Manual switch with 3 positions: Permanent ON/AUTO/permanent OFF Switching status display
■ ■ ■
Daily program
MEM 190 a ■ ■ ■
SUL 180 a
■
As SYN 160 a, but:
■
Weekly program With power reserve (exchangeable NiMH rechargeable battery) 84 switching segments Quartz controlled Shortest switching time: 2 hours
With power reserve (exchangeable NiMH rechargeable battery) Quartz controlled
■
SYN 160 a ■
Without power reserve 96 switching segments Synchronised with mains Shortest switching time: 15 minutes
■
■
Product selection Program
Number of channels
Daily program
1
Weekly program
1
32
Catalogue_ZEIT_GB_2010.indd 32
Power reserve
Shortest switching time
Programmable every
Type of contact
Operating voltage
Type
Article number
–
15 min
15 min
NO contact
230 V AC
SYN 160 a
1600001
3 days
15 min
15 min
NO contact
230 V AC
SUL 180 a
1800001
3 days
2h
2h
NO contact
230 V AC
MEM 190 a
1900001
http
Additional technical data at: www.theben.de/product/ Article number
24.03.10 12:06
Analogue time switches
TIME
SYN, SUL, MEM
DIN-rail, 1 module
Technical data SYN 160 a Operating voltage Frequency
SUL 180 a
MEM 190 a
230 V AC
230-240 V AC
50 Hz
50-60 Hz 1 module
Width
DIN-rail
Installation type Daily program
Program
Weekly program
–
Power reserve
3 days
Max. switching capacity at 250 V AC, cos φ = 1
16 A
Max. switching capacity at 250 V AC, cos φ = 0.6
4A
Shortest switching time
15 min
2h
Programmable every
15 min
2h
Synchronised with mains
Time accuracy
≤ ± 1 s/day(Quartz)
Power consumption
1 VA
Test approvals
V
Type of protection
IP 20 II in accordance with EN 60 730-1
Protection class –25 °C … +50 °C
Ambient temperature
Accessories Wall installation kit 17.5 mm ■
Art.No.: 9070065 Page 55 Details
▶
–10 °C … +50 °C
Connection example Front panel mounting kit ■
SYN 160 a, SUL 180 a, MEM 190 a
Art.No.: 9070001 Page 54 Details
▶
C1 2
N
1
L N L L
http
Additional technical data at: www.theben.de/product/ Article number
Catalogue_ZEIT_GB_2010.indd 33
33
24.03.10 12:06
Time switches with segments
SYN and SUL
DIN-rail, 1 module
TIME
40% faster wiring with DuoFix spring terminals
34
Catalogue_ZEIT_GB_2010.indd 34
24.03.10 12:06
Time switches with segments
TIME
There is something in the air. Fresh air in offices, schools public buildings and factories is usually provided by ventilation systems. They can be controlled by a time program which guarantees a regular and controlled supply of fresh air at set times. This is proved to be beneficial in terms of health, concentration and well being, but without wasting energy.
The SYN and SUL time switches from Theben have been proven a million times over and have still been improved. Precisely programmable, faster to connect and this is all "Made in Germany".
24 HR. – LINE DESCRIPTIONS Lettering on the clock face ensures that the day and night programmes are not accidentally mixed up. It is very clear when setting, when e.g. 3:00am or 3:00pm is displayed next to the hand. 15 MINUTE SEGMENTS For precise time programmes with precise 15 minute settings. 96 folding segments can be programmed in just seconds.
SYN and SUL
DIN-rail, 1 module
DuoFix spring terminals 2 wires can be connected per terminal. Each of the wires is secured by its own spring. 40% time saved Connection is even faster thanks to DuoFix spring terminals. It is instantly wired regardless of 0.5mm2, 1.5mm2 or 2.5 mm2 wire or cable. Thanks to the integrated button, the plug-in connection to the phase tester can be easily released.
PERMANENT SWITCH: ON/TIMED/OFF Manually connected consumers can be switched permanently ON or permanent OFF at any time, e.g. with pond pumps, Christmas lighting etc. SWITCHING STATUS DISPLAY AND SWITCHING PRE-SELECTION If you leave home early or come back home early – that's not a problem: One turn of the pre-selection switch and the unit is turned on or off early on time only.
35
Catalogue_ZEIT_GB_2010.indd 35
24.03.10 12:06
Analogue time switches
TIME
DIN-rail, 3 modules
SYN und SUL
TimeAnalogue time switchesDIN-rail, 3 modules
Analogue time switches – 3 modules – switching segments SYN 151 h
SUL 181 d
SUL 191 w
SYN 161 d
SUL 191 w
Description Common functions ■ ■ ■ ■ ■ ■
Analogue time switch 1 channel DuoFix spring terminals Switching preselection Manual switch with 3 positions: Permanent ON/AUTO/permanent OFF Switching status display
■ ■ ■ ■
■ ■ ■ ■ ■ ■
SYN 151 h ■
Daily program Without power reserve 96 switching segments Synchronised with mains Shortest switching time: 15 minutes Clock hands for time display and in addition 12/24 hour recognition Simple summer/winter time correction
■
60 minute program Without power reserve 96 switching segments Synchronised with mains Shortest switching time: 37.5 seconds
■ ■ ■ ■ ■ ■ ■
SUL 181 d
Weekly program With power reserve (NiMH rechargeable battery) 84 switching segments Quartz controlled Shortest switching time: 2 hours Clock hands for time display and in addition 12/24 hour recognition Simple summer/winter time correction
As SYN 161 d, but: With power reserve (NiMH rechargeable battery) Quartz controlled
■ ■
Product selection Program
Number of channels
Power reserve
Shortest switching time
Programmable every
60 minute program
1
–
37.5 s
37.5 s
Daily program
–
15 min
15 min
1 200 hours
15 min
15 min
Weekly program
1
200 hours
2h
2h
36
Catalogue_ZEIT_GB_2010.indd 36
Type of contact Changeover contact Changeover contact Changeover contact Changeover contact
Operating voltage
Type
Article number
230 V AC
SYN 151 h
1510011
230 V AC
SYN 161 d
1610011
SUL 181 d
1810011
SUL 191 w
1910011
110 – 230 V AC 110 – 230 V AC
http
Additional technical data at: www.theben.de/product/ Article number
24.03.10 12:06
Analogue time switches
TIME
SYN und SUL
DIN-rail, 3 modules
Technical data SYN 151 h Operating voltage
SYN 161 d
SUL 181 d
SUL 191 w
230 V AC
110-230 V AC
50 Hz
50-60 Hz
Frequency
3 modules
Width
DIN-rail
Installation type 60 minute program
Program
Daily program
Weekly program
–
Power reserve Max. switching capacity at 250 V AC, cos φ = 1
200 hours
10 A
16 A
Max. switching capacity at 250 V AC, cos φ = 0.6
4A
Shortest switching time
37.5 s
15 min
2h
Programmable every
37.5 s
15 min
2h
Synchronised with mains
Time accuracy
≤ ± 1 s/day(Quartz)
Power consumption
1 VA
Test approvals
V
Type of protection
IP 20 II in accordance with EN 60 730-1
Protection class
–20 °C … +55 °C
Ambient temperature
Accessories Wall installation kit 52.5 mm ■
Art.No.: 9070050 Page 55 Details
▶
Connection example Front panel mounting kit ■
SYN 151 h, SYN 161 d, SUL 181 d, SUL 191 w
Art.No.: 9070001 Page 54 Details
▶
C1 1
2
3
L
N N L L
http
Additional technical data at: www.theben.de/product/ Article number
Catalogue_ZEIT_GB_2010.indd 37
37
24.03.10 12:06
Analogue time switches
TIME
DIN-rail, 3 modules
TimeAnalogue time switchesDIN-rail, 3 modules
Analogue time switches – 3 modules – tappet SUL 188 hw
SUL
SUL 188 g
Description Common functions ■ ■ ■ ■ ■ ■ ■
SUL 188 g
Analogue time switch With power reserve (NiMH rechargeable battery) Quartz controlled Tappets Screw terminals Switching status display Operating indication
■ ■ ■ ■ ■
SUL 188 hw
Daily program 2 channels Fine adjustment to set the time to the minute Shortest switching time: 30 minutes 10 tappets included in delivery
■ ■ ■ ■ ■
Daily program and 1/2 day OFF function for the weekdays 1 channel (with series connection of the 2 contacts) Tappets and turning segments Shortest switching time: 45 minutes (12 hours for the 1/2 day OFF function) 6 tappets included in delivery
Product selection Program Daily program Daily program and 1/2 day OFF function
38
Catalogue_ZEIT_GB_2010.indd 38
Number of channels
Power reserve
Shortest switching time
Programmable every
2
3 days
30 min
30 min
1
3 days
45 min/12 h
45 min/12 h
Type of contact
Operating voltage
Type
Article number
2 Changeover contacts
230 V AC
SUL 188 g
1880033
Changeover contact
230 V AC
SUL 188 hw
1880108
http
Additional technical data at: www.theben.de/product/ Article number
24.03.10 12:06
Analogue time switches
TIME
DIN-rail, 3 modules
SUL 188 g
SUL 188 hw
Operating voltage
230 V AC
Frequency
50-60 Hz
Width
3 modules DIN-rail
Installation type Daily program
Program
Daily program with 1/2 day OFF function 3 days
Power reserve Max. switching capacity at 250 V AC, cos φ = 1
10 A
Max. switching capacity at 250 V AC, cos φ = 0.6
4A
Shortest switching time
30 min
45 min/12 h
Programmable every
30 min
45 min/12 h ≤ ± 1 s/day(Quartz)
Time accuracy Power consumption
1 VA
Test approvals
V
Type of protection
IP 20 II in accordance with EN 60 730-1
Protection class
–20 °C … +55 °C
Ambient temperature
Accessories Terminal box cover plate 52.5 mm ■
Art.No.: 9070061 Page 54 Details
▶
SUL
Technical data
Connection example Front panel mounting kit ■
SUL 188 g
SUL 188 hw
Art.No.: 9070001 Page 54 Details
▶
C2 4
5
7d 6
7
4
C1 1
2
3
8
1 N L L
http
5
6
7
3
8
24h 2
N L L
Additional technical data at: www.theben.de/product/ Article number
Catalogue_ZEIT_GB_2010.indd 39
39
24.03.10 12:07
Time switches with tappets
SYN and SUL
Front panel installation/wall mounting
TIME
Day or week? It's up to you.
40
Catalogue_ZEIT_GB_2010.indd 40
24.03.10 12:07
Time switches with tappets
TIME
At the heart of the system. Circulation pumps ensure an immediate supply of hot water from in all the water outlets in the building. Easy to use but costintensive. Energy expenditure can be significantly reduced by using timers: Programmed for the periods of highest demand, the pump only switches on, for example, in the morning and evening – an environmentally-friendly and economic solution.
Switchable for daily or weekly programs. Ideal mounted timer for rental properties, e. g. with weekly program for pump control for single people or employed couples, night switch off for families with children who are at home during the day.
SWITCHING THE TIME SWITCH It is very easy to switch the time switch from daily to weekly program by lifting the graduated ring. The graduated ring printed on both sides is reset here with weekly sections. The pins can now be inserted for the weekly program for the days of the week from 1– 7. SWITCHING DISPLAY AND SWITCHING PRE-SELECTION If you leave home early or come back home early – that's not a problem: One turn of the pre-selection switch and heating or lighting will switch ON or OFF early on time only.
SYN and SUL
Front panel installation/wall mounting
FRONT PANEL INSTALLATION The device can be installed in a cut-out of 69 x 69 mm and for walls up to 19 mm thick. Connection either by terminal screws or 2.8 mm flat pins. SEMI-AUTOMATIC Thanks to flexible use of the tappet, semiautomatic function is possible, when e.g. it is switched on manually and then the OFF pins are used in the evening.
PERMANENT ON/OFF Manually connected consumers can be switched permanently ON or OFF at any time, e. g. in the case of fountains, Christmas lighting etc. The existing or manually set relay status can be easily fixed by releasing the switching lever.
41
Catalogue_ZEIT_GB_2010.indd 41
24.03.10 12:07
Analogue time switches
TIME
Front panel installation/wall installation
SYN und SUL
TimeAnalogue time switchesFront panel installation/wall installation
Analogue time switches – wall installation – tappet SYN 269 h
SUL 289 g
Description Common functions ■ ■ ■ ■ ■
■
Analogue time switch with daily or weekly program (switching disc can be turned) Tappets Shortest switching time: 20 minutes or 2 hours Clock hands for time display Switching status display
SYN 269 h ■ ■
■ ■ ■ ■
SYN 269 g ■ ■ ■
1 channel Without power reserve
Synchronised with mains Switching preselection Permanent ON/OFF switch Simple summer/winter time correction 32 tappets included in delivery
■
2 channels Without power reserve Synchronised with mains 49 tappets included in delivery
SUL 289 h
As SYN 269 h, but: ■ ■
With power reserve (NiMH rechargeable battery) Quartz controlled
SUL 289 g ■ ■ ■ ■
2 channels With power reserve (NiMH rechargeable battery) Quartz controlled 49 tappets included in delivery
Product selection Program
Daily program or weekly program
42
Catalogue_ZEIT_GB_2010.indd 42
Number of channels
Power reserve
Shortest switching time
Programmable every
1
–
20 min or 2 h
5 min or 30 min
2
–
20 min or 2 h
5 min or 30 min
1
3 days
20 min or 2 h
5 min or 30 min
2
3 days
20 min or 2 h
5 min or 30 min
Type of contact Changeover contact 2 Changeover contacts Changeover contact 2 Changeover contacts
Operating voltage
Type
Article number
230 V AC
SYN 269 h
2690008
230 V AC
SYN 269 g
2690033
230 V AC
SUL 289 h
2890008
230 V AC
SUL 289 g
2890033
http
Additional technical data at: www.theben.de/product/ Article number
24.03.10 12:07
Analogue time switches
TIME
SYN und SUL
Front panel installation/wall installation
Technical data SYN 269 h
SYN 269 g
SUL 289 h 230 V AC
Operating voltage 50 Hz
Frequency
50-60 Hz Front panel installation/wall installation
Installation type
Daily program or weekly program
Program –
Power reserve
3 days
Max. switching capacity at 250 V AC, cos φ = 1
10 A
Max. switching capacity at 250 V AC, cos φ = 0.6
2A 20 min or 2 h
Shortest switching time
5 min or 30 min
Programmable every Synchronised with mains
Time accuracy
≤ ± 1 s/day(Quartz)
Power consumption
1 VA
Type of protection
IP 20 II in accordance with EN 60 730-1
Protection class
–10 °C … +55 °C
Ambient temperature
Accessories
Scale drawings
Quick fastening 72 x 72
SYN 269 h, SYN 269 g, SUL 289 h, SUL 289 g
■
SUL 289 g
Art.No.: 9070071 Page 55 Details
▶
69 54 16
104
65
72
66
72
25
Connection example SYN 269 h, SUL 289 h
SYN 269 g, SUL 289 g
C1 1
2
C1 3
7
1
8
2
C2 3 4
N L L
5
6 7
8 N L L
http
Additional technical data at: www.theben.de/product/ Article number
Catalogue_ZEIT_GB_2010.indd 43
43
24.03.10 12:07
Analogue time switches
TIME
Front panel installation/wall installation
TM und SUL
TimeAnalogue time switchesFront panel installation/wall installation
Analogue time switches – wall installation – tappets TM 179 h
SUL 189 hw
Description TM 179 h ■ ■ ■ ■ ■ ■ ■
■
Analogue time switch with 60 minute program 1 channel Without power reserve Synchronised with mains Tappets Shortest switching time: 75 seconds Switching preselection
■
Switching status display 6 tappets included in delivery
■
SUL 189 hw ■ ■
■
Analogue time switch with daily program and 1/2 day OFF function for the weekdays 1 channel (with series connection of the 2 contacts)
■ ■ ■ ■
With power reserve (NiMH rechargeable battery) Quartz controlled Tappets and turning segments Shortest switching time: 30 minutes (12 hours for the 1/2 day OFF function) Switching status display 6 tappets included in delivery
Product selection Program 60 minute program Daily program and 1/2 day OFF function
44
Catalogue_ZEIT_GB_2010.indd 44
Number of channels
Power reserve
Shortest switching time
Programmable every
1
–
1.25 min
18.5 s
1
3 days
30 min/12 h
15 min/12 h
Type of contact
Operating voltage
Type
Article number
Changeover contact
230 V AC
TM 179 h
1790008
Changeover contact
230 V AC
SUL 189 hw
1890108
http
Additional technical data at: www.theben.de/product/ Article number
24.03.10 12:07
Analogue time switches
TIME
TM und SUL
Front panel installation/wall installation
Technical data TM 179 h
SUL 189 hw 230 V AC
Operating voltage 50 Hz
Frequency
50-60 Hz Front panel installation/wall installation
Installation type Program
60 minute program
Daily program with 1/2 day OFF function
–
3 days
Power reserve Max. switching capacity at 250 V AC, cos φ = 1
10 A
Max. switching capacity at 250 V AC, cos φ = 0.6
2A 1.25 min
30 min/12 h
18.5 s
15 min/12 h
Synchronised with mains
≤ ± 1 s/day(Quartz)
Shortest switching time Programmable every Time accuracy Power consumption
1 VA
Type of protection
IP 20 II in accordance with EN 60 730-1
Protection class
–10 °C … +55 °C
Ambient temperature
Accessories
Scale drawings
Quick fastening 72 x 72
TM 179 h, SUL 189 hw
■
Art.No.: 9070071 Page 55 Details
▶
69 54 16
104
65
72
66
72
25
Connection example TM 179 h
SUL 189 hw
24h
C1 1
2
3
7
1
8
2
7d 3 4
N L L
5
6 7
8 N L L
http
Additional technical data at: www.theben.de/product/ Article number
Catalogue_ZEIT_GB_2010.indd 45
45
24.03.10 12:07
Analogue time switches
TIME
Front panel installation/wall installation
SYN und SUL
TimeAnalogue time switchesFront panel installation/wall installation
Analogue time switches – wall installation – switching segments SYN 169 s
SUL 189 s
Description Common functions ■ ■ ■ ■ ■ ■
■
Analogue time switch with daily program 1 channel 96 switching segments Shortest switching time: 15 minutes Clock hands for time display Switching preselection
■ ■
Permanent ON/OFF switch Switching status display Simple summer/winter time correction
■
■ ■
SYN 169 s ■
SUL 189 s
With power reserve (NiMH rechargeable battery) Quartz controlled
Without power reserve Synchronised with mains
Product selection Program
Daily program
46
Catalogue_ZEIT_GB_2010.indd 46
Number of channels
Power reserve
Shortest switching time
Programmable every
–
15 min
15 min
Changeover contact
3 days
15 min
15 min
Changeover contact
1
Type of contact
Operating voltage
Type
Article number
230 V AC
SYN 169 s
1690801
230 V AC
SUL 189 s
1890801
110 V AC
SUL 189 s 110V
1891801
http
Additional technical data at: www.theben.de/product/ Article number
24.03.10 12:07
Analogue time switches
TIME
SYN und SUL
Front panel installation/wall installation
Technical data SYN 169 s
SUL 189 s
SUL 189 s 110V
230 V AC
Operating voltage
110 V AC
50 Hz
Frequency
50-60 Hz Front panel installation/wall installation
Installation type
Daily program
Program –
Power reserve
3 days
Max. switching capacity at 250 V AC, cos φ = 1
10 A
Max. switching capacity at 250 V AC, cos φ = 0.6
2A
Shortest switching time
15 min
Programmable every
15 min Synchronised with mains
Time accuracy
≤ ± 1 s/day(Quartz) 1 VA
Power consumption
W
Test approvals
IP 20
Type of protection
II in accordance with EN 60 730-1
Protection class
–10 °C … +55 °C
Ambient temperature
Accessories
Scale drawings
Connection example
Quick fastening 72 x 72
SYN 169 s, SUL 189 s
SYN 169 s, SUL 189 s
■
Art.No.: 9070071 Details Page 55
▶
69 54 16
104
72
66
72
C1 65
25
1
2
3
7
8 N L L
http
Additional technical data at: www.theben.de/product/ Article number
Catalogue_ZEIT_GB_2010.indd 47
47
24.03.10 12:08
Analogue time switches
TIME
Wall installation/3-point mounting
TimeAnalogue time switchesWall installation/3-point mounting
SUL 285
Analogue time switch – wall installation/3-point mounting SUL 285/1 T
SUL 285/2 T
Description Common functions ■ ■ ■ ■
■
Analogue time switch with daily program With power reserve (exchangeable NiMH battery) Quartz controlled Tappets
■ ■ ■ ■ ■
Shortest switching time: 20 minutes Clock hands for time display Switching status display Simple summer/winter time correction Control LED for battery change 32 tappets included in delivery
SUL 285/1 T ■
1 channel
SUL 285/2 T ■
2 channels
Product selection Program
Number of channels
Power reserve
Shortest switching time
Programmable every
1
6 days
20 min
5 min
2
6 days
20 min
5 min
Daily program
48
Catalogue_ZEIT_GB_2010.indd 48
Type of contact Changeover contact 2 Changeover contacts
Operating voltage
Type
Article number
110/230 V AC
SUL 285/1 T
2850008
110/230 V AC
SUL 285/2 T
2850033
http
Additional technical data at: www.theben.de/product/ Article number
24.03.10 12:08
Analogue time switches
TIME
SUL 285
Wall installation/3-point mounting
Technical data SUL 285/1 T
SUL 285/2 T 110 V AC/230 V AC
Operating voltage
50-60 Hz
Frequency
Daily program
Program
6 days
Power reserve Max. switching capacity at 250 V AC, cos φ = 1
6A
Max. switching capacity at 250 V AC, cos φ = 0.6
2A
Shortest switching time
20 min
Programmable every
5 min ≤ ± 1 s/day(Quartz)
Time accuracy Power consumption
1 VA
Type of protection
IP 54 II in accordance with EN 62,054-21
Protection class
–10 °C … +55 °C
Ambient temperature
Scale drawings
Connection example
SUL 285/1 T, SUL 285/2 T
SUL 285/1 T 74
175
121,5
6,5
105
SUL 285/2 T
C1 1
2 1a 3
4
C1 5
N L L
84,5 101,5
http
C2
L 1a N 3 4 5 6 7 8
N L L
Additional technical data at: www.theben.de/product/ Article number
Catalogue_ZEIT_GB_2010.indd 49
49
24.03.10 12:08
Analogue time switches
TIME
Plug-in
Analogue socket time switches – switching segments theben-timer 26
theben-timer 27
theben-timer 26
theben-timer 27
N TIMER BE
!
.4
YEAR
.4
%%
*AHRE
!
'!2
theben-timer 26 IP 44
¬
THE
theben-timer
TimeAnalogue time switchesPlug-in
)%¬ ' 5 ! 2
Description Common functions ■ ■ ■ ■ ■ ■ ■
Analogue plug-in timer 1 channel Without power reserve Synchronised with mains Use with earthed sockets (additional socket types upon request) Switching preselection Switching status display
■ ■ ■
Daily program 96 switching segments Shortest switching time: 15 minutes
■ ■ ■
Weekly program 84 switching segments Shortest switching time: 2 hours
theben-timer 26 IP 44
As theben-timer 26, but: ■ ■
Waterproof protection for damp locations and outdoor areas Transparent cover
Product selection Program
Shortest switching time
Programmable every
Type of contact
Operating voltage
Daily program
15 min
15 min
NO contact
230 V AC
Weekly program
2h
2h
NO contact
230 V AC
50
Catalogue_ZEIT_GB_2010.indd 50
Type
Article number
theben-timer 26
0260030
theben-timer 26 IP 44
0260855
theben-timer 27
0270930
http
Additional technical data at: www.theben.de/product/ Article number
24.03.10 12:08
Analogue time switches
TIME
theben-timer
Plug-in
Technical data theben-timer 26
theben-timer 26 IP 44
theben-timer 27
230 V AC
Operating voltage
50 Hz
Frequency
Socket (plug-in)
Installation type Daily program
Program
Weekly program
Max. switching capacity at 250 V AC, cos φ = 1
16 A
Max. switching capacity at 250 V AC, cos φ = 0.6
4A
Shortest switching time
15 min
2h
Programmable every
15 min
2h Synchronised with mains
Time accuracy
0.8 VA
Power consumption
V
Test approvals IP 20
Type of protection
IP 44
IP 20
I in accordance with EN 60 730-1
Protection class –10 °C … +55 °C
Ambient temperature
Scale drawings
–40 °C … +55 °C
–10 °C … +55 °C
Connection example
13
12 11 10 9
14
5
19 18 17
6
16
7
15
10
10
8
71
41
4
3
20
2
1
24 23 22 2 1
http
Additional technical data at: www.theben.de/product/ Article number
Catalogue_ZEIT_GB_2010.indd 51
51
24.03.10 12:08
Analogue time switches
TIME
Wall installation/DIN rail
TimeAnalogue time switchesWall installation/DIN rail
FRI 77
Analogue cooling timers - tappets FRI 77 h
FRI 77 g-2
Description Common functions ■ ■ ■ ■ ■
FRI 77 h
Analogue cooling timer with daily and short time program for defrosting Tappets Synchronised with mains Shortest switching time: 2 minutes / 1 hour 2 separate switching discs
■ ■ ■
FRI 77 h-2
1 channel Wall-mounted 6 tappets included in delivery
FRI 77 g ■ ■ ■ ■
■
1 channel Drive with quick fastening for DIN rail
■
6 tappets included in delivery
■
2 channels Wall-mounted 8 tappets included in delivery Optional delayed switching on of fan
FRI 77 g-2
As FRI 77 g, but: ■
Drive with quick fastening for DIN rail
Product selection Type of contact
Installation type
Shortest switching time
Programmable every
Operating voltage
Type
Article number
Changeover contact
Wall-mounted
2 min/1 h
1 min/1 h
230 V AC
FRI 77 h
0770008
2 Changeover contacts
Wall-mounted
2 min/1 h
1 min/1 h
230 V AC
FRI 77 g
0770033
2 min/1 h
1 min/1 h
230 V AC
FRI 77 h-2
0770802
2 min/1 h
1 min/1 h
230 V AC
FRI 77 g-2
0770832
Changeover contact 2 Changeover contacts
52
Catalogue_ZEIT_GB_2010.indd 52
Drive with quick fastening for DIN rail Drive with quick fastening for DIN rail
http
Additional technical data at: www.theben.de/product/ Article number
24.03.10 12:08
Analogue time switches
TIME
Wall installation/DIN rail
FRI 77 h
FRI 77 g
FRI 77 h-2
FRI 77
Technical data FRI 77 g-2
230 V AC
Operating voltage
50 Hz
Frequency Wall-mounted
Installation type
Drive with quick fastening for DIN rail Daily and defrost program
Program Max. switching capacity at 250 V AC, cos φ = 1
16 A
Max. switching capacity at 250 V AC, cos φ = 0.6
2.5 A
Shortest switching time
2 min/1 h
Programmable every
1 min/1 h Synchronised with mains
Time accuracy Power consumption
2.5 VA
Test approvals
VW IP 20
Type of protection
IP 00 II in accordance with EN 60 730-1
Protection class
–10 °C … +50 °C
Ambient temperature
Scale drawings FRI 77 h-2, FRI 77 g-2
FRI 77 h-2, FRI 77 g-2 82
61
48
105
55
105
Connection example FRI 77 h, FRI 77 h-2
1
K1 2
3
FRI 77 g, FRI 77 g-2
7
1
8
K1 2
3 4
N L L
K2 5
6 7
8 N L L
http
Additional technical data at: www.theben.de/product/ Article number
Catalogue_ZEIT_GB_2010.indd 53
53
24.03.10 12:08
Analogue time switches
ACCESSORIES
Wall installation/DIN rail
ACCESSORIES
ACCESSORIES
Description Antenna top2 RC-DCF
Suitable for
Type
Article number
TR 611 top2 RC LUNA 121 top2 RC LUNA 122 top2 RC SELEKTA 171 top2 RC TR 641 top2 RC TR 642 top2 RC TR 644 top2 RC
Antenna top2 RC-DCF
9070410
TR 611 top2 RC LUNA 121 top2 RC LUNA 122 top2 RC SELEKTA 171 top2 RC TR 641 top2 RC TR 642 top2 RC TR 644 top2 RC
Antenna top2 RC-GPS (Available July 2010)
9070610
■
All DIN rail installation devices
Front panel kit
9070001
■
TR 611 top2 RC LUNA 121 top2 RC LUNA 122 top2 RC SELEKTA 171 top2 RC
Power unit top2 GPS (Available July 2010)
9070892
Terminal cover 52.5 mm
9070061
OBELISK top2 PC set
9070409
■ ■ ■ ■
Time synchronisation with DCF antennas for top2 devices Installation see DCF77 antennas
■ ■ ■ ■ ■
■
Antenna top2 RC-GPS
Worldwide time synchronisation and positioning via receiving GPS satellite signal. The antenna is connected by a 2 wire cable (max. 100 m) to Theben top2 RC devices (up to 10 devices can be connected). A top2 GPS power unit (item number 9070892) is also required when connecting to TR 611 op2 RC, LUNA 121 top2 RC, LUNA 122 top2 RC or SELEKTA 171 top2 RC devices. No additional power un it is required when connecting to TR 641 top2 RC, TR 642 top2 RC, TR 644 top2 RC devices or several devices to one antenna. Positioning is possible with TR 641 top2 RC, TR 642 top2 RC, TR 644 top2 RC and SELEKTA 171 top2 RC devices.
■ ■ ■ ■ ■ ■ ■
Front panel kit ■
■
■
Power unit top2 GPS
■
Front panel installation set is suitable for Theben DIN rail installation devices of 17.5 to 107.5 mm width. Walls from 1 to 5 mm thick
Necessary for antennas top2 RC-GPS in combination with TR 611 top2 RC, LUNA 121 top2 RC, LUNA 122 top2 RC or SELEKTA 171 top2 RC (the power unit is not necessary when 2 or more devices are connected to the antenna) Width 2 modules (35 mm)
■ ■ ■
■
Terminal cover 52.5 mm
■ ■ ■ ■
Terminal box cover plate for assembly, sealable
■ ■ ■ ■ ■
TM 178 h SYN 168 h SUL 188 h SUL 188 g MEM 198 h SUL 188 hw TM 171 h SYN 161 h SUL 181 h
OBELISK top2 PC set ■
54
Catalogue_ZEIT_GB_2010.indd 54
OBELISK top2 memory card, USB plug-in adapter, software Updates of existing OBELISK top2 software are available as free downloads at www.theben.de .
■ ■ ■
TR top2 LUNA top2 SELEKTA top2
http
weitere technische Daten unter: www.theben.de/produkt/ Artikel-Nr.
24.03.10 12:08
Analogue time switches
ACCESSORIES
Description
Suitable for
Type
Article number
■
All time switches for front panel/wall installation
Quick fastening 72 x 72
9070071
■
TR top2 LUNA top2 SELEKTA top2
Memory card OBELISK top2
9070404
All DIN rail installation devices with 1 modules width
Wall mounting kit 17.5 mm
9070065
All DIN rail installation devices with 2 modules width
Wall mounting kit 35 mm
9070064
All DIN rail installation devices with 3 modules width
Wall mounting kit 52.5 mm
9070050
All DIN rail installation devices with 4 modules width
Wall mounting kit 70 mm
9070049
Quick fastening 72 x 72
■
Snap-on mounting for 35 mm DIN rails
■
Individual memory card
Memory card OBELISK top2
■ ■
ACCESSORIES
Wall installation/DIN rail
Wall mounting kit 17.5 mm
■ ■
Wall installation set for top mounting, sealable
■
Wall installation set for top mounting, sealable
■
Wall installation set for top mounting, sealable
■
Wall installation set for top mounting, sealable
Wall mounting kit 35 mm
■
Wall mounting kit 52.5 mm
■
Wall mounting kit 70 mm
■
http
weitere technische Daten unter: www.theben.de/produkt/ Artikel-Nr.
Catalogue_ZEIT_GB_2010.indd 55
55
24.03.10 12:08
1210
We reserve the right to make technical modifications and improvements. Catalogue_ZEIT_GB_2010.indd 56
9900642
Theben AG Hohenbergstraße 32, 72401 Haigerloch, GERMANY Postfach 56, 72394 Haigerloch, GERMANY Phone +49 (0) 74 74/6 92-0 Fax +49 (0) 74 74/6 92-150
[email protected], www.theben.de
24.03.10 12:02