Preview only show first 10 pages with watermark. For full document please download

Digital Clock

   EMBED


Share

Transcript

MECHANICAL 1.335 3.00 .590 TYP 45° 4 PL. M802 DIGITAL CLOCK 15:54:26GMT C 23:54:26 .050 L GREENWICH MEAN TIME LOCAL TIME ELAPSED TIME - Count Down Timer 2.375 Local Time 2.250 +.005-015 MODE MENU 4-40 CS 82° TYP 4 PL. DATA PLATE / SERIAL NUMBER MOUNTED ON BOTTOM 1.875 ELECTRICAL Digital Probe Data (Orange) Keep Alive .01A 5 Ground to Start Flight Time 9 4 .25A + M802 Battery GRAPHICS LCD Dimming 5V 8 4V to 28V Starts Flight Time 3 7 Digital Probe 5V DC (White) 2 6 14 to 28 Volts, 1A 1 Digital Probe Ground (Blue) GND SPECIFICATIONS    Greenwich Mean Time: 24 hour format. Local Time: 24 hour format. Elapsed Time: Displays up to 99 hours, 59 minutes, 59 seconds.  Count Down Time: Displays hours, minutes, and seconds.  Elapsed Time Alarm: Activates at zero when counting down.       Graphics LCD Keep Alive Current: .01 Amps. Input Current: .1 Amps. Input Voltage: 14V to 28V (backlight available 5V). FEATURES  Two button control system. Setting operations are identical for both alarm and time setting.   Graphics LCD. Weight: 4.5 ounces. Warranty: 1 year. 427 HILLCREST WAY REDWOOD CITY (Emerald Hills), CA 94062 (650) 369-1188 • (866) 369-5588 www.davtron.com Illuminated buttons.    Elapsed Time. Countdown Timer. Temperature compensated crystal for premium time. M802 DIGITAL CLOCK CLOCK OPERATION Normal Operation MODE selects what is to be displayed on the graphics LCD. Pressing MODE sequentially selects Local Time, Elapsed Time, and Count Down Timer. Menu Screen Simultaneously pressing both buttons will enter the menu screen. The menu screen allows the user to set GMT, Local Time, Contrast, and Backlight. Pressing SELECT scrolls through each setting option. To exit menu and return to the previous screen, select the “Exit” option and press ENTER. Setting GMT Enter into Menu Screen, select “SET GMT”, and press ENTER. The tens of hour digit will start flashing. Once the tens of hour is set, pressing NEXT scrolls through each digit setting. After seconds have been set, press DONE to go back into Menu Screen. To exit menu and return to normal operation, select the “Exit” option from the menu screen and press ENTER. Setting LT Enter the Menu Screen, select “SET Local Time”, and press ENTER. The tens of hour digit will start flashing. By default, the hours and minutes are synchronized with GMT, but the minutes can be changed in increments of 15 minutes relative to GMT. Minutes and seconds cannot be set in LT with the exception of the 15 minute increments. Pressing DONE will return to Menu Screen. To exit menu and return to normal operation, select the “Exit” option and press ENTER. Elapsed Time In normal operation, select Elapsed Time function. Pressing START activates ET. ET counts up to 99 hours, 59 minutes, and 59 seconds. Pressing STOP pauses ET. Pressing CLEAR will reset ET to zero. Countdown Timer Local Time Menu Elapsed Time Count Down Timer In normal operation, select Count Down Timer function. To set CDT, hold MODE down for 3 seconds until “Set CDT” screen appears. The tens of hour digit will start flashing. Once the tens of hour is set, pressing NEXT scrolls through each digit setting. After seconds have been set, press DONE to go back into CDT function. Pressing START will activate CDT. When CDT reaches zero, the display will flash and begin counting up. Pressing CANCEL will deactivate the alarm. Pressing STOP pauses CDT overflow. Pressing RESET will reset the CDT to zero.