Preview only show first 10 pages with watermark. For full document please download

Digital I/o Module Engineering Information

   EMBED


Share

Transcript

Digital I/O Module Engineering Information I/O MODULES Our line of pluggable input and output modules provide a low cost, versatile method for interconnecting real world analog and digital signals to data acquisition, monitoring, or control systems. All modules provide an optically isolated barrier between sensitive microprocessor or digital logic circuits and field power devices. In the G5 and OpenLine® packages, analog and digital I/O modules are available with the same pin-out. This gives the flexibility of mixing and matching module types on the same mounting rack or base; making them perfect in applications which require interface to a variety of different sensors and loads. The case color of the single point modules identify their function. The industry standard for single point I/O module case colors is: Digital AC Output Module = Black Case Digital DC Output Module = Red Case Digital AC Input Module = Yellow Case Digital DC Input Module = White Case DIGITAL OUTPUT MODULES Digital output modules are used to switch AC and DC loads such as solenoids, motors, or lamps from logic signal levels. Their inputs are directly compatible with TTL or CMOS interface circuitry. AC output modules have zero voltage turn-on of the load to greatly reduce generated EMI and RFI. They are highly immune to electrical transients, and have built-in RC snubber networks for increased capability with inductive loads. DC output modules can operate DC loads over a wide voltage range and have built-in voltage spike protection. DIGITAL INPUT MODULES Digital input modules are used to monitor the status of a load or a sensor (such as a limit switch, pressure switch, or temperature switch). The output of these modules is a logic level signal which corresponds to the status of the device being monitored. A high level output signal indicates the load is off (the switch is open). A low level output signal indicates the load is on (the switch is closed). Input modules are designed to give fast, clean switching by providing filtering and hysteresis. Input and output modules are compatible in that the output of one can drive the input of the other. UL, CSA AND CE APPROVALS As one of the world's leading manufacturers of I/O modules, we strive to assure that our products comply with all of the applicable international standards. In doing so, we believe your products will also be readily accepted and easily certified. All modules shown in this section have been tested to UL Standard 508 and are documented in UL file number E58632. Similarly, they have been tested to CSA Standard 22.2 No. 14-95M and are documented in CSA file LR38763. Additionally, OpenLine® modules were tested and passed CSA 22.2 No. 213-M1987 Class I, Div. 2 Groups A, B, C and D. Parts bearing the CE logo indicate conformance with EN50082-2 and EN50081-2 (89/336/EEC EMC directive) as well as EN60950 (61010-1) for the low voltage directive. Contact Grayhill for copies of our Declaration of Conformity or visit out website. Parts bearing the TÜV logo indicate that they were the agency which performed the EN60950 evaluation. CONSTRUCTION AND LIFETIME WARRANTY All of our I/O modules are hard potted with thermally conductive epoxy to withstand harsh industrial environments. The modules provide optical isolation, immunity to mechanical shock and vibration, and operate over a wide temperature range. The module cases are a solvent resistant thermoplastic which meets UL94-V-0 rating. The terminal pins are a tinplated copper wire. Component selection and surface mount construction allow low operating junction temperatures for long life. Superior design, rigorous testing, and field data give us the confidence to back our I/O modules with the industry's first lifetime warranty. I/O MODULE WIRING Analog and digital modules can be placed at any I/O location, however, to minimize the possibility of crosstalk and noise pickup it is a good practice to group similar module types together. 14 or 16 gauge wire is typically used to wire the field devices to the I/O rack terminal block. PART NUMBER EXPLANATION: Digital I/O Modules I/O Modules Module Type 70 = Digital Module, Standard Package 70G = Digital Module, G5 Package 70L = Digital Module, OpenLine® Package 70M = Digital Module, Mini Package 70M-ODC5A Function OAC = ODC = IAC = IDC = Digital Output AC Digital Output DC Digital Input AC Digital Input DC Suffix AC Inputs: DC Inputs: AC Outputs: DC Outputs: Blank = 120 Vac Blank = 3-32 Vdc G = 35-60 Vac/Vdc L = Inductive loads A = 220 Vac B = Fast Switching D = 2.5–28 Vdc S = Dry Contacts Blank = 120 Vac MA = 120 Vac, Manual Override AMA = 240 Vac, Manual Override Blank = 3-60 Vdc Fast MA = 3-60 Vdc, Manual Override NP = 15-32 Vac/10-32 Vdc K = 2.5-16 Vdc A = 220 Vac A-11 = Non-Zero Cross A-5 = Normally Closed A = 4-200 Vdc R = Dry Contact B = 3-60 Vdc, Low Leakage Logic Supply Voltage or Range Digital Modules: Blank = 4.5-28 Vdc (OpenLine®) 5 Vdc, 15 Vdc, 24 Vdc = Logic Supply Voltage (Standard, Mini, G5) Analog Modules: 4.75-5.25 Vdc H-3 Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com Digital I/O Modules Engineering Information DIMENSIONS: OpenLine® Digital Modules Dimensions shown in inches (and millimeters). Tolerances are ± .010 (0,25) unless indicated otherwise. Module Type I/O Module Pin # 1 2 3 4 5 6 7 8 9 Output Function Output A+ Output AOutput B+ Output BLogic Gnd Vcc Ch. A Input Ch. B Input Module ID Input Function Input A+ Input AInput B+ Input BLogic Gnd Vcc Ch. A Status Ch. B Status Module ID FUSE HOLDERS (OUTPUTS ONLY) GREEN STATUS LEDS DATE CODE .025 (0,635) SQ. .34 (8,64) .51 (12,95) 2.09 (53,09) .19 (4,83) .03 (0,76) .10 (2,54) .22 (5,59) PIN 9 PIN 8 PIN 7 PIN 6 PIN 5 PIN 4 PIN 3 PIN 2 PIN 1 .14 (3,56) 2.49 (63,25) 2.23 (56,64) .38 (9,65) .24 (6,10) 2.70 (68,58) Note: For PC board layout information, request Bulletin #745 DIMENSIONS: G5 Digital Modules Dimensions shown in inches (and millimeters). Tolerances are ± .010 (0,25) unless indicated otherwise. Input Modules Ouput Modules 1.90 (48,3) 1.90 (48,3) .46 (11,7) .46 (11,7) GREEN STATUS LED I/O Modules GREEN STATUS LED FUSE HOLDER 4-40 X 2-1/2" PHILLIPS HOLDDOWN SCREW INCLUDED WITH EACH MODULE MAXIMUM TORQUE = 5 FT-LB 2.55 (64,8) 2.20 (55,9) 5 4 3 2 1 2.20 (55,9) O .040/.042 (1,02/1,07) .235 (5,97) 4 3 2 .20 (5,1) 1.15 (29,2) 1.35 (34,3) .235 (5,97) .20 (5,1) .40 (10,2) .90 (22,9) 1 O .040/.042 (1,02/1,07) .40 (10,2) .20 (5,1) .15 (3,8) .90 (22,9) 1.15 (29,2) .20 (5,1) .15 (3,8) 1.35 (34,3) 1.55 (39,4) Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com H-4 Digital I/O Modules Engineering Information DIMENSIONS: Standard and Miniature Digital Modules Dimensions shown in inches (and millimeters). Tolerances are ± .010 (0,25) unless indicated otherwise. Standard Module Miniature Module 1.00 (25,4) .60 (15,2) .40 (10,2) 4–40 X 1-1/2" PHILLIPS HOLDDOWN SCREW INCLUDED WITH EACH MODULE MAXIMUM TORQUE = 5 FT-LB 1.70 (43,2) 1.70 (43,2) 1.25 (31,8) 5 4 3 2 Ø .040/.042 (1,02/1,07) .235 ± .02 (6,0 ± 0,52) 1 1.00 (25,4) 5 4 3 2 Ø .040/.042 (1,02/1,07) 1 .20 (5,1) .235 ±.020 (6,0 ± 0,52) .30 (7,6) .30 (7,6) .30 (7,6) .10 (2,5) .40 (10,2) .90 (22,9) 1.10 (27,9) 1.30 (33,0) .40 (10,2) OUTPUT MODULES HAVE ONLY TERMINALS NUMBER 1-4 .90 (22,9) 1.10 (27,9) 1.30 (33,0) OUTPUT MODULES HAVE ONLY TERMINALS NUMBER 1-4 WIRING DIAGRAM: Digital I/O Modules DIGITAL AC OUTPUT I/O Modules H-5 LOAD 2 1 DIGITAL DC OUTPUT 2 1 DIGITAL AC INPUT 2 1 DIGITAL DC INPUT 2 1 DIGITAL CONTACT CLOSURE 2 LOAD HOT AC SUPPLY NEUTRAL + DC SUPPLY – HOT AC SUPPLY NEUTRAL + DC SUPPLY – 1 Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com AC Output Modules FEATURES • Transient Protection: Meets the requirements of IEEE 472, “Surge Withstanding Capability Test” • SPST, Normally Open • Zero Crossing Turn-On • UL, CSA, CE, TÜV Certified • Optical Isolation • OpenLine® and G5 Modules Provide Replaceable 5x20 mm Glass Fuses • Built-in Status LED • Lifetime Warranty •• TUV R h e i n l a n d 70L-OAC 70G-OAC 70-OAC 70M-OAC 4 LOAD CURRENT (AMPS) Maximum Current Versus Ambient Temperature The chart indicates continuous current to limit the junction temperatures to 100°C. Information is based on steady state heat transfer in a 2 cubic foot sealed enclosure. 3 2 STANDARD, G5 PACKAGES MINIATURE PACKAGE DIMENSIONS For complete dimensional drawings, see pages H-4 or H-5. OPENLINE PACKAGE/CH 1 FUSES -40˚ G5 Fuses are 5 Amp Littelfuse part number 217005 or equivalent. OpenLine® fuses are 3.15 Amp Littelfuse part number 217315. -20˚ 0 20˚ 40˚ 60˚ 80˚ AMBIENT TEMPERATURE (˚C) 100˚ Fuse kits available, see page H-106. Figure 1 CIRCUITRY Standard, Mini, G5 LOAD OpenLine TYPICAL WIRING FOR MODULE 0 SNUBBER 2 GND 5 Vcc 6 CHANNEL A A TRIGGER CIRCUIT CH. A CONTROL Rx OPTICAL ISOLATION CH. B CONTROL 3 1 1 2 2 3 3 4 4 LOAD SNUBBER SNUBBER LOAD CHANNEL B DC CONTROL – OPTICAL ISOLATION 7 B + I/O MODULE PIN # 1 VAC LOAD ® 2.15K 4 MODULE ID RACK OR BASE MODULE Fuse and status LED in G5 and OpenLine modules only. TERMINAL BLOCK # I/O Modules SPECIFICATIONS: By Package Style Package Style Specifications Load Current Range Maximum 1 Cycle Surge2 Maximum Turn-On-Time (60 Hz)3 Maximum Turn-Off Time (60 Hz) Static dv/dt7 Typ. Power Dissipation Isolation Voltage4 Vibration5 Mechanical Shock6 Storage Temp. Range Operating Temp. Range Warranty 2 3 4 5 6 7 Mini (70M-) G5 (70G-) OL (70L-) 0.03 to 3.5 80 8.33 8.33 3000 1.0 4000 MIL-STD-202 MIL-STD-202 -40 to 125 -40 to 100 Lifetime 0.03 to 3.0 80 8.33 8.33 3000 1.0 4000 MIL-STD-202 MIL-STD-202 -40 to 125 -40 to 100 Lifetime 0.03 to 3.5 80 8.33 8.33 3000 1.0 4000 MIL-STD-202 MIL-STD-202 -40 to 125 -40 to 100 Lifetime 0.03 to 2.0/CH 30 8.33 8.33 3000 1.0 2500 IEC68-2-6 IEC68-2-27 -40 to 100 -40 to 85 Lifetime Units 1 1 Std (70-) A rms A rms mSec mSec V/µsec W/A V rms °C °C See Figure 1 for derating. Maximum 10 cycle surge is 50% of 1 cycle surge. Application of maximum surge may not be repeated until module temperature has returned to its steady state value. Except 70-OAC5A5 which is 200 µSec and 70-OAC5A-11, 70M-OAC5A-11, and 70G-OAC5A-11 which are 100 µSec. Field to logic and channel-to-channel if Grayhill racks are used. MIL-STD-202, Method 204, 20 , 10-2000 Hz or IEC68-2-6, 0.15 mm/sec2, 10-150 Hz. MIL-STD-202, Method 213, Condition F, 1500G or IEC68-2-27, 11 mS, 15g. Except part numbers with -L suffix which have a dv/dt rating of 200 V/µSec. H-7 Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com AC Output Modules SPECIFICATIONS: By Part Number Standard and Miniature Modules Type/Function Grayhill Part Number Miniature, Normally Open, Random Turn-on 70M-OAC5A-11 Miniature, Normally Open, Zero Voltage Turn-on (ZVT) 70M-OAC5 70M-OAC5A Miniature, Normally Open, ZVT, Inductive Load 70M-OAC5-L 70M-OAC5A-L Standard, Normally Closed, Random Turn-on 70M-OAC15A 70M-OAC24 70M-OAC24A 70-OAC15 70-OAC15A 70-OAC24 70-OAC24A 120 24-140 400 2 24 15-30 9 2700 1 -5 240 24-280 600 4 24 15-30 9 2700 1 -5 70G-OAC24 70G-OAC24A 70-OAC5A5 Standard, Normally Open, Random Turn-on 70-OAC5A-11 Standard, Normally Open, ZVT Standard, Normally Open, ZVT, Inductive Load Specifications Nominal Line Voltage Load Voltage Range Minimum Peak Blocking Voltage Maximum Off-state Leakage @ 60Hz Nominal Logic Voltage (Vcc) Logic Voltage Range Max. Logic Supply Current @ Nominal Vcc Nominal Input Resistance (Rx) Minimum Drop Out Voltage Maximum Reverse Logic Voltage 70M-OAC15 Units Vac Vac Volts mA, rms Vdc Vdc mA Ω Vdc Vdc 70-OAC5 70-OAC5A 70-OAC5-L 70-OAC5A-L 120 24-140 400 2 5 2.5-10 16 240 1 -5 70-OAC24A-11 240 24-280 600 4 5 2.5-10 16 240 1 -5 120 24-140 400 2 15 10-18 9 1800 1 -5 240 24-280 600 4 15 10-18 9 1800 1 -5 G5 Modules Grayhill Part Number Type/Function G5 Fusible, Normally Open, ZVT 70G-OAC5 G5 Fusible, Normally Open, ZVT, Inductive Load 70G-OAC5-L 70G-OAC5A-L G5 Fusible, Normally Open, Random Turn-on Specifications 70G-OAC5A 70G-OAC15 70G-OAC15A 70G-OAC15-L 70G-OAC15A-L 70G-OAC24-L 70G-OAC24A-L 70G-OAC5A-11 Units Nominal Line Voltage Load Voltage Range Minimum Peak Blocking Voltage Maximum Off-state Leakage @ 60Hz Nominal Logic Voltage (Vcc) Logic Voltage Range Max. Logic Supply Current @ Nominal Vcc Nominal Input Resistance (Rx) Minimum Drop Out Voltage Maximum Reverse Logic Voltage Vac Vac Volts mA, rms Vdc Vdc mA W Vdc Vdc 120 24-140 400 2 5 4-6 20 100 1 -5 240 24-280 600 4 5 4-6 20 100 1 -5 120 24-140 400 2 15 8-20 12 1000 1 -5 240 24-280 600 4 15 8-20 12 1000 1 -5 120 24-140 400 2 24 18-32 8 2700 1 -5 240 24-280 600 4 24 18-32 8 2700 1 -5 Type/Function Grayhill Part Number Dual, Fusible, Normally Open, ZVT Dual, Fusible, Normally Open, ZVT, Inductive Load Specifications Units Nominal Line Voltage Load Voltage Range Minimum Peak Blocking Voltage Maximum Off-State Leakage @ 60 Hz Nominal Logic Voltage Logic Voltage Range Max. Logic Supply Current @ Nominal Vcc Module ID Resistance to Logic Ground Minimum Drop Out Voltage Vac Vac Volts mA, rms Vdc Vdc mA Ω Vdc 70L-OAC 70L-OACA 70L-OAC-L 70L-OACA-L 120 24-140 600 2 5 4.5-28 7/CH 2.15K 1 240 24-280 600 4 5 4.5-28 7/CH 2.15K 1 Available from your local Grayhill Distributor. For prices and discounts, contact a local Sales Office, an authorized local Distributor or Grayhill. Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com H-8 I/O Modules OpenLine® Modules DC Output Modules FEATURES • Transient Protection: Meets the requirements of IEEE 472, "Surge Withstanding Capability Test" • SPST, Normally Open • UL Recognized, CSA Certified, CE Mark, TÜV (see Engineering Information) • Optical Isolation • OpenLine® and G5 Modules Provide Replaceable 5 x 20 mm Glass Fuse • Built-in Status LED • Lifetime Warranty •• TUV R h e i n l a n d 70L-ODC 70G-ODC 70-ODC 70M-ODC 4 LOAD CURRENT (AMPS) Maximum Current Versus Ambient Temperature The chart indicates continuous current to limit the junction temperatures to 115°C. Information is based on steady state heat transfer in a 2 cubic foot sealed enclosure. 3 2 1 DIMENSIONS STANDARD, G5 PACKAGES For complete dimensional drawings, see pages H-4 or H-5. MINIATURE PACKAGE OPENLINE PACKAGE/CH FUSES G5 Fuses are 5 Amp Littelfuse part number 217005 or equivalent. OpenLine® fuses are 3.15 Amp Littelfuse part number 217315. 200 VDC STYLE -40˚ -20˚ 0 20˚ 40˚ 60˚ 80˚ AMBIENT TEMPERATURE (˚C) OpenLine ® Standard, Mini, G5 LOAD VOLTAGE SPIKE PROTECTION LOAD GND 5 Vcc 6 CHANNEL A A 2 CH. A CONTROL 7 OPTICAL ISOLATION DRIVER CIRCUIT DRIVER CIRCUIT OPTICAL ISOLATION – 1 1 LOAD 2 2 DC SUPPLY 3 3 DC SUPPLY 4 4 LOAD DRIVER CIRCUIT CHANNEL B CH. B 8 CONTROL Rx 3 – I/O Modules 2.15K DC CONTROL – + + B + I/O MODULE PIN # TYPICAL WIRING FOR MODULE 0 1 VDC – Fuse kits available, see page H-106. Figure 1 CIRCUITRY + 100˚ MODULE ID 9 4 BASE OR RACK Fuse and status LED in G5 and OpenLine modules only. TERMINAL BLOCK # SPECIFICATIONS: By Package Style Package Style Specifications Load Current Range Surge Current for 1 Sec. Maximum Reverse Logic Voltage Isolation Voltage2 Vibration3 Mechanical Shock4 Storage Temp. Range Operating Temp. Range Warranty 2 3 4 Mini (70M-) G5 (70G-) OL (70L-) 0.02-3.5 5 -5 4000 MIL-STD-202 MIL-STD-202 -40 to 125 -40 to 100 Lifetime 0.02-3.0 5 -5 4000 MIL-STD-202 MIL-STD-202 -40 to 125 -40 to 100 Lifetime 0.02-3.5 5 -5 4000 MIL-STD-202 MIL-STD-202 -40 to 125 -40 to 100 Lifetime 0.02-2.0/CH 5 -5 2500 IEC68-2-6 IEC68-2-27 -40 to 100 -40 to 85 Lifetime Units 1 1 Std (70-) A A Vdc Vrms °C °C See Figure 1 for derating. Field to logic and channel-to-channel if Grayhill racks are used. MIL-STD-202, Method 204, 20 G, 10-2000 Hz or IEC68-2-6, 0.15 mm/sec2, 10-150 Hz. MIL-STD-202, Method 213, Condition F, 1500 G or IEC68-2-27, 11 mS, 15g. H-9 Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com DC Output Modules SPECIFICATIONS: By Part Number Standard and Miniature Modules Type/Function Grayhill Part Number Miniature, Normally Open Standard, Normally Open 70M-ODC5 70M-ODC5A 70M-ODC5B 70M-ODC15 70-ODC5 70-ODC5A 70-ODC5B 70-ODC15 70M-ODC15B 70-ODC15B 70M-ODC24 70M-ODC24B 70-ODC24 70-ODC24B Specifications Units Maximum Line Voltage Load Voltage Range Max. Off-State Leakage @ Max. Line Maximum Turn-On Time Maximum Turn-Off Time Typ. Power Dissipation Clamping Voltage Nominal Logic Voltage (Vcc) Logic Voltage Range Maximum Logic Supply Current @ Nominal Vcc Nominal Input Resistance (Rx) Minimum Drop Out Voltage Vdc Vdc mA µSec µSec W/A Vdc Vdc Vdc 60 3-60 1.5 20 50 1 80 5 2.5-10 200 4-200 0.01 75 750 1.5 360 5 2.5-9 60 3-60 0.01 75 500 1 80 5 2.5-10 60 3-60 1.5 20 50 1 80 15 10-18 60 3-60 0.01 75 500 1 80 15 10-18 60 3-60 1.5 20 50 1 80 24 15-30 60 3-60 0.01 75 500 1 80 24 15-30 mA Ω Vdc 14 300 1 18 220 1 14 300 1 9 1800 1 9 1800 1 9 2700 1 9 2700 1 G5 and OpenLine® Modules Grayhill Part Number Type/Function Fusible, Normally Open Specifications 70G-ODC5 70G-ODC5A 70G-ODC5B 70G-ODC15 70G-ODC15B 70G-ODC24 70G-ODC24B Units Maximum Line Voltage Load Voltage Range Max. Off-State Leakage @ Max. Line Maximum Turn-On Time Maximum Turn-Off Time Typ. Power Dissipation Clamping Voltage Nominal Logic Voltage (Vcc) Logic Voltage Range Maximum Logic Supply Current @ Nominal Vcc Nominal Input Resistance (Rx) Minimum Drop Out Voltage Vdc Vdc mA µSec µSec W/A Vdc Vdc Vdc 60 3-60 1.5 20 50 1 80 5 4-6 200 4-200 0.01 75 750 1.5 360 5 4-6 60 3-60 0.01 75 500 1 80 5 4-6 60 3-60 1.5 20 50 1 80 15 10-20 60 3-60 0.01 75 500 1 80 15 10-20 60 3-60 1.5 20 50 1 80 24 18-32 60 3-60 0.01 75 500 1 80 24 18-32 mA Ω Vdc 13 150 1 13 150 1 13 150 1 9 1500 1 9 1500 1 9 2700 1 9 2700 1 OpenLine® Modules Type/Function Grayhill Part Number 70L-ODC 70L-ODCA 70L-ODCB Specifications Units Maximum Line Voltage Load Voltage Range Max. Off-State Leakage @ Max. Line Maximum Turn-On Time Maximum Turn-Off Time Typ. Power Dissipation Clamping Voltage Nominal Logic Voltage (Vcc) Logic Voltage Range Maximum Logic Supply Current @ Nominal Vcc Module ID Resistance to Logic Ground Minimum Drop Out Voltage Vdc Vdc mA µSec µSec WA Vdc Vdc Vdc 60 3-60 1.5 20 50 1 80 5 4.5-28 200 4-200 .01 75 750 1.5 360 5 4.5-28 60 3-60 .01 75 500 1 80 5 4.5-28 mA 7/CH 7/CH 7/CH Ω Vdc 2.15K 1 2.15K 1 2.15K 1 Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com H-10 I/O Modules Dual, Fusible, Normally Open Available from your local Grayhill Distributor. For prices and discounts, contact a local Sales Office, an authorized local Distributor or Grayhill. AC Input Modules FEATURES • Transient Protection: Meets the requirements of IEEE 472, “Surge Withstanding Capability Test” • UL, CSA, CE, TÜV Certified (TÜV not available on OpenLine) • Optical Isolation • OpenLine ® and G5 Modules have Built-in Status LED • Lifetime Warranty •• TUV R h e i n l a n d 70L-IAC 70G-IAC 70-IAC 70M-IAC DIMENSIONS For complete dimensional drawings, see pages H-4 or H-5. CIRCUITRY OpenLine® Standard, Mini, G5 I/O MODULE PIN # Rx 1 TYPICAL WIRING FOR MODULE 70 VDC 6 Vcc 7 CH. A STATUS 5 GND 8 CH. B STATUS 9 MODULE ID A 2 INPUT DEVICE 1 1 FILTER OPTICAL ISOLATION +VCC 3 INPUT VOLTAGE HYST. CIRC. INPUT DEVICE CURRENT REGULATING OUTPUT 2 2 3 3 OPTICAL ISOLATION 4 4 GROUND TERMINAL BLOCK # 5 B FILTER * HYSTERESIS HYSTERESIS 4 BASE OR RACK Status LED in G5 modules only. 0Ω MODULE * Separate supplies may also be used. SPECIFICATIONS: By Package Style I/O Modules Package Style 1 2 3 Specifications Units Output Current Range Minimum Output Breakdown Voltage Maximum Turn-On Time Maximum Turn-Off Time Isolation Voltage 1 Vibration2 Mechanical Shock3 Storage Temp. Range Operating Temp. Range Warranty mA Vdc mS mS Vrms °C °C Std (70-) Mini (70M-) G5 (70G-) OL (70L-) 1-50 50 20 20 4000 MIL-STD-202 MIL-STD-202 -40 to +125 -40 to +100 Lifetime 1-50 50 20 20 4000 MIL-STD-202 MIL-STD-202 -40 to +125 -40 to +100 Lifetime 1-50 50 20 20 4000 MIL-STD-202 MIL-STD-202 -40 to +125 -40 to +100 Lifetime 1-50 50 20 20 2500 IEC68-2-6 IEC68-2-27 -40 to +100 -40 to +85 Lifetime Field to logic and channel-to-channel if Grayhill racks are used. MIL-STD-202, Method 204, 20 G, 10-2000 Hz or IEC68-2-6, 0.15 mm/sec2, 10-150 Hz. MIL-STD-202, Method 213, Condition F, 1500 G or IEC68-2-27, 11 mS, 15g. H-15 Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com AC Input Modules SPECIFICATIONS: By Part Number Standard and Miniature Modules Type/Function Grayhill Part Number Miniature Standard 70M-IAC5 70-IAC5 Specifications 70M-IAC5A 70-IAC5A 70M-IAC15 70M-IAC15A 70M-IAC24 70-IAC15 70-IAC15A 70-IAC24 70M-IAC24A 70-IAC24A Units Nominal Input Voltage Vac Vac/Vdc Input Voltage Range1 Input Current @ Maximum Input Voltage mA, rms Nominal Input Resistance (Rx) Ω Maximum Pick-Up Voltage (Output Low) Vac Minimum Drop-Out Voltage (Output High) Vac Nominal Logic Voltage (Vcc) Vdc Logic Voltage Range Vdc Max. Logic Supply Current @ Nominal Vcc mA 120 90-140 8 22K 90 25 5 3-6 10 240 180-280 6 60K 180 50 5 3-6 10 120 90-140 8 22K 90 25 15 8-18 10 240 180-280 6 60K 180 50 15 8-18 10 120 90-140 8 22K 90 25 24 15-30 10 240 180-280 6 60K 180 50 24 15-30 10 G5 Modules Type/Function Grayhill Part Number G5, Status LED 70G-IAC5 Specifications 70G-IAC5A 70G-IAC15 70G-IAC15A 70G-IAC24 70G-IAC24A Units Nominal Input Voltage Vac Input Voltage Range1 Vac/Vdc Input Current @ Maximum Input Voltage mA, rms Nominal Input Resistance (Rx) Ω Maximum Pick-Up Voltage (Output Low) Vac Minimum Drop-Out Voltage (Output High) Vac Nominal Logic Voltage (Vcc) Vdc Logic Voltage Range Vdc Max. Logic Supply Current @ Nominal Vcc mA 120 0-140 8 22K 90 25 5 4.5-6 10 240 0-280 6 60K 180 50 5 4.5-6 10 120 0-140 8 22K 90 25 15 10-18 10 240 0-280 6 60K 180 50 15 10-18 10 120 0-140 8 22K 90 25 24 17-30 10 240 0-280 6 60K 180 50 24 17-30 10 OpenLine® Modules Grayhill Part Number Type/Function Dual, Status LED Specifications 1 70L-IACA 120 0-140 8 22K 90 25 5 4.5-28 6/CH 0 240 0-280 6 64K 180 50 5 4.5-28 6/CH 0 Units Vac Vac/Vdc mA, rms " Vac Vac Vdc Vdc mA " I/O Modules Nominal Input Voltage Input Voltage Range1 Input Current @ Max. Input Voltage Nominal Input Resistance (Rx) Max. Pick-Up Voltage (Output Low) Min. Drop-Out Voltage (Output High) Nominal Logic Voltage (Vcc) Logic Voltage Range Max. Logic Supply Current @ Nominal Vcc Module ID Resistance to Logic Ground 70L-IAC Available from your local Grayhill Distributor. For prices and discounts, contact a local Sales Office, an authorized local Distributor or Grayhill. For input voltages in the range of 15-32 Vac, or 35-60 Vac, see DC input Modules with the NP or G suffix. Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com H-16 DC Input Modules FEATURES • Fast Switching Polarized Input Types • UL, CSA, CE, TÜV Certified (TÜV not available on OpenLine®) • Optical Isolation • OpenLine® and G5 Modules have Built-in Status LED •• TUV R h e i n l a n d 70L-IDC 70G-IDC 70-IDC DIMENSIONS 70M-IDC For complete dimensional drawings, see pages H-4 or H-5. CIRCUITRY OpenLine® Standard, Mini, G5 + I/O MODULE PIN # Rx 1 TYPICAL WIRING FOR MODULE 0 VDC 2 INPUT DEVICE 1 1 FILTER OPTICAL ISOLATION FILTER OPTICAL ISOLATION – +VCC 3 INPUT VOLTAGE HYST. CIRC. CURRENT REGULATING OUTPUT INPUT DEVICE + 2 2 3 3 + DC SUPPLY 4 – GROUND 5 TERMINAL BLOCK # Status LED in G5 modules only. 4 4 6 Vcc A + HYSTERESIS B 7 CH. A STATUS 5 GND 8 CH. B STATUS 9 MODULE ID HYSTERESIS – BASE OR RACK 0Ω MODULE SPECIFICATIONS: By Package Style Package Style I/O Modules 1 2 3 Specifications Units Output Current Range Minimum Output Breakdown Voltage Isolation Voltage1 Vibration2 Mechanical Shock3 Storage Temp. Range Operating Temp. Range Warranty mA Vdc Vrms °C °C Std (70-) Mini (70M-) G5 (70G-) OL (70L-) 1-50 50 4000 MIL-STD-202 MIL-STD-202 -40 to 125 -40 to 100 Lifetime 1-50 50 4000 MIL-STD-202 MIL-STD-202 -40 to 125 -40 to 100 Lifetime 1-50 50 4000 MIL-STD-202 MIL-STD-202 -40 to 125 -40 to 100 Lifetime 1-50 50 2500 IEC68-2-6 IEC68-2-27 -40 to 100 -40 to 85 Lifetime Field to logic and channel-to-channel if Grayhill racks are used. MIL-STD-202, Method 204, 20G, 10-2000 Hz or IEC68-2-6, 0.15 mm/sec2, 10-150 Hz. MIL-STD-202, Method 213, Condition F, 1500G or IEC68-2-27, 11 mS, 15g. H-19 Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com DC Input Modules SPECIFICATIONS: By Part Number Standard and Miniature Modules Type/Function Grayhill Part Number Miniature, Polarized Standard, Non-Polarized Specifications Units Maximum Input Voltage Input Voltage Range1 Input Current @ Maximum Input Voltage Maximum Turn-On Time Maximum Turn-Off Time Nominal Input Resistance (Rx) Maximum Pick-Up Voltage (Output Low) Minimum Drop-Out Voltage (Output High) Nominal Logic Voltage (Vcc) Logic Voltage Range Max. Logic Supply Current @ Nominal Vcc Vdc Vdc mA mSec mSec Ω Vdc Vdc Vdc Vdc mA 70M-IDC5 70-IDC5 70-IDC5B 32 3-32 18 0.20 0.40 1.8K 3 1 5 3-6 10 32 3-32 18 0.050 0.075 1.8K 3 1 5 3-6 18 70-IDC5K 16 2.5-16 30 0.025 0.030 500 2.5 1 5 3.5-6 18 70M-IDC15 70-IDC15 32 3-32 18 0.20 0.40 1.8K 3 1 15 8-18 10 70M-IDC24 70-IDC24 32 3-32 18 0.20 0.40 1.8K 3 1 24 15-30 10 G5 Modules Type/Function Grayhill Part Number G5, Polarized, Status LED 70G-IDC5 Specifications Units Maximum Input Voltage Input Voltage Range1 Input Current @ Maximum Input Voltage Maximum Turn-On Time Maximum Turn-Off Time Nominal Input Resistance (Rx) Maximum Pick-Up Voltage (Output Low) Minimum Drop-Out Voltage (Output High) Nominal Logic Voltage (Vcc) Logic Voltage Range Max. Logic Supply Current @ Nominal Vcc Vdc Vdc mA mSec mSec Ω Vdc Vdc Vdc Vdc mA 32 3-32 18 0.20 0.40 1.8K 3 1 5 4.5-6 10 70G-IDC5B 70G-IDC5D 70G-IDC5K 32 3-32 18 0.050 0.075 1.8K 3 1 5 4.5-6 18 28 2.5-28 23 0.050 0.075 1.2K 2.5 1 5 4.5-6 10 16 2.5-16 30 0.025 0.030 500 2.5 1 5 4.5-6 18 70G-IDC15 70G-IDC24 32 3-32 18 0.20 0.40 1.8K 3 1 15 10-18 10 32 3-32 18 0.20 0.40 1.8K 3 1 24 17-30 10 OpenLine® Modules Type/Function Grayhill Part Number Dual, Polarized 70L-IDCB Specifications Units Maximum Input Voltage Input Voltage Range1 Input Current @ Max. Input Voltage Maximum Turn-on Time Maximum Turn-off Time Nominal Input Resistance (Rx) Maximum Pick-Up Voltage (Output Low) Minimum Drop-Out Voltage (Output High) Nominal Logic Voltage (Vcc) Logic Voltage Range Max. Logic Supply Current @ Nominal Vcc Module ID Resistance to Logic Ground Vdc Vdc mA mSec mSec Ω Vdc Vdc Vdc Vdc 32 0-32 18 0.20 0.40 1800 3 0.9 5 4.5-28 32 0-32 18 0.05 0.075 900 3 0.9 5 4.5-28 mA Ω 6/CH 0 6/CH 0 I/O Modules 1 70L-IDC Available from your local Grayhill Distributor. For prices and discounts, contact a local Sales Office, an authorized local Distributor or Grayhill. For input voltages in the range of 90 to 140 Vdc, use AC input modules 70-IAC5, 70M-IAC5, 70G-IAC5 or 70L-IAC. For input voltages in the range of 180 to 280 Vdc, use AC input modules 70-IAC5A, 70M-IAC5A, 70G-IAC5A or 70L-IACA. Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com H-20