Transcript
Digital Meters With A Multicolour Bargraph LEL-NA3 – one-channel LEL-NA5 – one-channel LEL-NA6 – two-channel
Inputs: Pt100
LEL-NA3 (-200…+850)°C
Pt500
(-200…+850)°C
Pt100
(-200…+850)°C
J (Fe-CuNi)
(-30…+1100)°C
K (NiCr-NiAl)
(-50…+1370)°C
N (NiCrSi-NiSi)
(-100…+1300)°C
E (NiCr-CuNi)
(-20…+850)°C
R (PtRh13-Pt) S (PtRh10-Pt) T (Cu-CuNi) Resistance measurement Voltage measurement
Digital-analogue meters of LEL-NA series with a multicolour bargraph have a universal input destined to measure temperature, resistance, shunt voltage, standard signals, d.c. Voltage and d.c. Current. They are used in various industrial fields, e.g. food industry, pumping stations and sewage-treatment plants, chemical industry, weather stations, brewing industry and many other fields where they provide a visualisation of the measured value and evaluation of the monitored manufacturing process change trend. They can also find application in automation systems where programmable controllers are applied. LEL-NA meters can have optionally: analogue continuous outputs, relay outputs, OC type outputs and RS-485 digital output. These meters are programmed by means of a keyboard and through RS485 LEL-NA meters have the following functions: • Measurement of the input quantity and display on the LED display and bargraph • Evaluation of the input signal into the indication on the base of the individual linear characteristic • Arithmetical: raising to a power, extraction of roots (additionally in LEL-NA6, operations in channels: summation, subtraction multiplication, division) • Programming of the bargraph colour and resolution • Signalling of the set alarm value exceeding • Recording of the measured signal in programmed time intervals • Peak and valley memory • Averaging of reading values over time • Programming of filter resolution • Lockout function by means of a password • Conversion of the measured quantity into an output voltage or current signal • Servicing of the RS-485 interface in MODBUS protocol, both in ASCII and RTU mode
Current measurement
Intensity of the current flowing through the resistance thermometer Resistance of wires linking the resistance thermometer with the meter
0…400 Ω 0…4000 Ω
LEL-NA(5/6) (-200…+850)°C measuring sub-range: 320°C (-200…+850)°C measuring sub-range: 230°C (-200…+850)°C measuring sub-range: 290°C (-100…+1100)°C measuring sub-ranges: 350°C, 700°C (-100…+1370)°C measuring sub-ranges: 450°C, 950°C (-100…+1300)°C measuring sub-ranges: 550°C, 1000°C (-100…+1100)°C measuring sub-ranges: 250°C, 520°C (-0…+1760)°C (-0…+1760)°C (-50…+400)°C 0…10kΩ measuring sub-ranges: 100Ω, 220Ω, 460Ω, 950Ω, 2100Ω, 5000Ω ±300 mV input resistance > 9MΩ ±600 V input resistance > 4,2 MΩ measuring sub-ranges: 19 mV, 35 mV, 75 mV, 155 mV, 5 V, 11 V, 22 V, 45 V, 90 V, 180 V, 360 V
0…60 mV input resistance > 9 MΩ 0…3 V input resistance > 4 MΩ 0…10 V input resistance > 4 MΩ 0…200 V input resistance > 4 MΩ 0…600 V input resistance > 4 MΩ 0…5 mA input resistance 4 Ω 0…20 mA input resistance 4 Ω 0…2A input resistance 10 mΩ ± 10 % 0…5A input resistance 10 mΩ ± 10 %
<170 µA
± 40 mA input resistance < 4 Ω ±5A input resistance 10 mΩ ± 10% measuring sub-ranges: 5 mA: 11 mA, 23 mA, 1.8 A, 3.8 A
<400 µA
< 20 Ω/wire
Thermocouple characteristics, acc. EN 60584-1 Resistance thermometer characteristicas, acc. IEX 751+A1+A2 OUTPUTS Analogue outputs • Galvanically isolated, with a resolution 0.025% of the range • Current programmed: 0/4…20 mA, load resistance ≤ 500Ω • Voltage programmed: 0…10 V, load resistance ≥ 500Ω • Output response time 100 ms • Output error 0.2% of the range
•
Additional error from ambient temperature change ± (0.1% of the range / 10K)
London Electronics Limited, Unit 4, Warren Court, Chicksands, Shefford, SG17 5QB Tel: +44 1462 850 967 Fax: +44 1462 850 968 Email:
[email protected] Web: www.london-electronics.com
•
Relay outputs: o 2 relays LEL-NA3 or 4 relays LEL-NA5, NA6, o voltageless make contacts – macimal load: voltage 250 V a.c., 150 V d.c. current 5 A 30 V d.c., 250 V a.c. resistance load 1250 VA, 150 W o programmed alarm thresholds o three types of alarms o hysteresis defined by means of the lower and upper alarm threshold o signalling of alarm operation on the bargraph 2 (LEL-NA3) or 8 (LEL-NA(5/6) outputs of OC type (open collector): voltageless, of OC type with npn transistor (macimal load 25 mA) range of added voltages: 5…24 V d.c.
•
•
Digital outputs Interface RS-485 Transmission protocol MODBUS ASCII 8N1, 7E1, 7O1 RTU 8N2, 8E1, 801, 8N1 o Baud rate 2400, 4800, 9600 bauds o Maximal response time to the query frame 300 ms
o o
•
Memory parameters: Meter memory (recording): LEL-NA3 750 samples LEL-NA(5/6) 750 samples(channel 1 or 2) Or 375 samples (channel 1) + 375 samples (channel 2) o minimal recording interval 1s
o
Basic error: o LEL-NA3 0.2% ± 1 digit o LEL-NA(5/6) 0.05% of the range/10K • Averaging time min 200 ms, min 500 ms (temp. ranges) •
• o o o o o o o •
Rated operation conditions: Supply voltage depending on the version code 95…230…253 V a.c./d.c. Frequency of the supply voltage 40…50/60…440 Hz ambient temperature –10…23…55°C storage temperature –25…+85°C relative humidity <95% (no condensation) pre-heating time of the meter 10 minutes working position any
Sustained overload o Thermocouples, resistance thermometers 1% o Voltage, current and resistance measurement 10%
• o o o
NA3-F
NA3-B NA3-D
NA5
NA6
4 seven segment LED displays, digit height 7mm, indication range –1999…9999 multicolour bargraph of 82mm length 45 segments in 3 colour version 25 segments in 7 colour version Multicolour bargraph as above 4 seven segment LED displays digit height: 14mm indication range –1999.9999 4 seven segment LED displays, digit height 7mm, indication range –1999…9999 multicolour bargraph of 88mm length 55 segments in 3 colour version 29 segments in 7 colour version 2x4 seven segment LED displays, digit height 7mm, indication range –1999…9999 multicolour bargraph of 88mm length 48 segments in 3 colour version 27 segments in 7 colour version
Bargraph resolution Bargraph accuracy Servicing
programmable ± 0.5 segment
3 keys
Protection grade ensured: By the housing LEL-NA3 IP40 LEL-NA(5/6) IP 50 From terminal side IP20 Dimensions: LEL-NA3 LEL-NA(5/6)
96x24x125mm (with terminals) 48x144x100mm (with terminals)
Cut-out dimensions in the panel: LEL-NA3 22.2+0.5 x 92+0.5mm LEL-NA(5/6) 44+0.5 x 137.5+0.5mm Weight
<0.4kg
Power consumption: LEL-NA3 < 8VA LEL-NA(5/6) <12 VA Resistance against voltage decay according to EN 61000-6-2 Electromagnetic compatibility Immunity EN 61000-6-2 Emission EN 61000-6-4 Safety requirements according EN 61010-1: Installation category III Pollution level 2 Working voltage in relation to the groud 600 V a.c.
Short duration overload (3s) Inputs of sensors 30 V Voltage input > 2.5V 10 Un (<1000V) Current input 10ln
London Electronics Limited, Unit 4, Warren Court, Chicksands, Shefford, SG17 5QB Tel: +44 1462 850 967 Fax: +44 1462 850 968 Email:
[email protected] Web: www.london-electronics.com
External Connections Diagrams NA3 Meter
Connection of input signals to NA5 and NA6 meters
NA5 NA6 meters
Lack of channel 2 in the NA5 meter
London Electronics Limited, Unit 4, Warren Court, Chicksands, Shefford, SG17 5QB Tel: +44 1462 850 967 Fax: +44 1462 850 968 Email:
[email protected] Web: www.london-electronics.com
Ordering codes
London Electronics Limited, Unit 4, Warren Court, Chicksands, Shefford, SG17 5QB Tel: +44 1462 850 967 Fax: +44 1462 850 968 Email:
[email protected] Web: www.london-electronics.com
London Electronics Limited, Unit 4, Warren Court, Chicksands, Shefford, SG17 5QB Tel: +44 1462 850 967 Fax: +44 1462 850 968 Email:
[email protected] Web: www.london-electronics.com