Transcript
TM
DIGITAL Storage RAID Controllers V2.0 13 February 1998 DIGITAL Systems and Options Catalog DIGITAL StorageWorks HSJ30 CI to FSE SCSI-2 Controllers (21 Devices) DIGITAL StorageWorks HSD30 DSSI to FSE SCSI-2 Array Controller (21 Devices) DIGITAL StorageWorks HSD10 DSSI to FSE SCSI-2 Array Controller (7 Devices) DIGITAL StorageWorks KZESC EISA to FSE SCSI-2 Array Controller DIGITAL StorageWorks HSD50 Series DSSI Array Controller for OpenVMS Systems DIGITAL StorageWorks HSJ50 Series CI Array Controller DIGITAL StorageWorks HSZ50 Series SCSI Array Controller DIGITAL StorageWorks KZPSC PCI to FWSE SCSI-2 RAID Array 230 Storage Controller DIGITAL StorageWorks KZPAC RAID Array 230/Plus Storage Controller DIGITAL RAID Array Controller Support Matrix
DIGITAL believes the information in this publication is accurate as of its publication date; such information is subject to change without notice. DIGITAL is not responsible for any inadvertent errors. DIGITAL conducts its business in a manner that conserves the environment and protects the safety and health of its employees, customers, and the community. DIGITAL, the DIGITAL logo are trademarks of Digital Equipment Corporation. Printed in USA. Copyright 1998 Digital Equipment Corporation. All rights reserved.
Storage
7.35
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks HSJ30 CI to FSE SCSI-2 controller (21 Devices) StorageWorks HSJ30 array controller expands CI support in the StorageWorks family of products. Each HSJ30 occupies one CI address location on the CI bus providing connectivity for up to 21 SCSI devices. The HSJ30 allows customers to significantly expand the number of CI-connected storage devices. HSJ30 array controller features a StorageWorks controller shelf compatible form factor. It can be installed in StorageWorks SW500 or SW800 cabinets, controlling up to 21 DIGITAL SCSI-2 devices, connected to up to three SCSI ports. An HSJ30 must be connected utilizing a star coupler. HSJ30 array controllers standard features include RAID 0 and support 16- or 32 MB read cache as an optional feature. Other optional features include Write-back Cache, Disk Mirroring (RAID Level 1), and Adaptive Raid 3/5. Features
Direct connection to the CI bus Connection for up to 21 SCSI Devices, 7 SCSI devices per StorageWorks shelf Provides controller based striping (Raid 0)
Optional Write-back Cache, Disk Mirroring (RAID Level 1) and Adaptive RAID 3/5 Wide drives supported in 8-bit mode
SCSI 8-bit Devices Supported
RZ25, .426 MB 8-bit disk RZ26, 1.05 GB 8-bit disk RZ26L, 1.05 GB 8-bit disk RZ26N, 1.05 GB 8-bit disk (V2.0 or above) RZ28, 2.1 GB 8-bit disk RZ28B, 2.1 GB 8-bit disk RZ28D, 2.1 GB 8-bit disk (V2.0 or above) RZ28M, 2.1 GB 8-bit disk (V2.0 or above) RZ29B, 4.3 GB 8-bit disk (V2.0 or above) RZ40, 9.1 GB 8 bit disk RZ74, 3.57 GB 8-bit disk, 5.25” EZ51/54/58R SCSI solid state disks EZ64, solid state disk EZ69, solid state disk RRD42/43/44/45/46 optical devices
TLZ06/TLZ6L 4mm tape devices TLZ07/TLZ7L 4mm tape devices (V2.0 /V2.5 or above) TL09/TLZ9L 4 mm tape drive & autoloader TZ86/87/87N tape devices TZ867/77/75 tape devices with loader TL820/810 DLT tape libraries TL812/822/826 DLT tape libraries TKZ60/61/62/63/64 tape devices TSZ07 reel to reel tape device RWZ52/53 optical devices RW524/525/530/531/532 optical juke boxes RW 546/551/552/555/557 optical juke boxes TZ88N tape device TZ885 tape drive loader TZ887 tape drive loader
SCSI 16-bit Devices Supported
RZ26L-VW, 1.05 GB 16-bit disk (V2.7) RZ26N-VW, 1.05 GB 16-bit disk (V2.7) RZ28-VW, 2.1 GB 16-bit disk (V2.7) RZ28D-VW, 2.1 GB 16-bit disk (V2.7) RZ28M-VW, 2.1 GB 16-bit disk (V2.7) RZ29B-VW, 4.3 GB 16-bit disk (V2.7) DS-RZ1BB; 2.1GB Ultra SCSI disk
DS-RZ1CB; 4.3GB Ultra SCSI disk DS-RZ1DB; 9.1GB Ultra SCSI disk TZ89 DLT Tape Drive TL893/894/896 DLT Tape Libraries EZ31/32-VW, solid state disk EZ64-VW, SCSI solid state disk EZ69-VW, SCSI solid state disk
Refer to HSOF Array Controller documentation for device restrictions. Adapters Supported
CIXCD, CIBCA,CI780, CIPCA
Storage
7.36
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks HSJ30 CI to FSE SCSI-2 controller (21 Devices) (continued) StorageWorks Environments Supported BA356-SC BA35X-MG BA35X-MH BA35X-HF BA350-MA/MB BA350-JA SW500-AC/AD SW800-AA/AB
Shelf, no personality module (V2.7 required) 8-bit module for BA356 (V2.7 required) 16-bit module for BA356 150 Watt 48 volt power supply Storage controller shelf Storage BA350-SA shelf kit StorageWorks departmental cabinet StorageWorks data center cabinet
Operating System Support OpenVMS VAX Version 5.5-2 or higher and OpenVMS Alpha V6.1 (or mixed clusters) support the HSJ30 with limitations. The limitations are the devices being identified as generic or unknown device types. The model type identifiers are not present in the operating system software. In addition, complete error log decoding is not provided under ERF. Ordering Information HSJ30-CA HSJ30-CD HSJ30-CF HSJ30-XD HSJ30-XF HSJ30-XE HSJ30-YC QL-4DSA9-AA
StorageWorks Array Controller, 18 SCSI-2 disk, tape, SSD, optical device support in dual-redundant configurations, 21 in non-redundant; RAID 0, base firmware and license StorageWorks Array Controller, 18 SCSI-2 disk, tape, SSD, optical device support in dual-redundant configurations, 21 in non-redundant; RAID 0, 16 MB cache, base firmware and license StorageWorks Array Controller, 18 SCSI-2 disk, tape, SSD, optical device support in dual-redundant configurations, 21 in non-redundant; RAID 0, 32 MB cache, base firmware and license 16 MB read cache option for HSJ30/40-AA 32 MB read cache option for HSJ30/40-AA, 32 MB total 16 MB read cache option for HSJ30/40-AD, 32 MB total, mandatory return of installed 16 MB cache HSJ30/40 Write-back Cache Option., license and batteries HSJ30/40 Disk Mirroring license
Storage
7.37
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks HSD30 DSSI to FSE SCSI-2 Array Controller (21 Devices) StorageWorks HSD30 array controller expands DSSI support in the StorageWorks family of products. Each HSD30 occupies one DSSI address location (there are 8 addresses per DSSI bus) on the DSSI bus providing connectivity for up to 21 SCSI devices. The HSD30 allows customers to significantly expand the number of DSSI-connected storage devices. HSD30 array controller features a StorageWorks controller shelf compatible form factor. It can be installed in StorageWorks SW500 or SW800 cabinets, controlling up to 21 DIGITAL SCSI-2 devices, connected to up to three SCSI ports. It can also be installed in the SW300 cabinet which allows connection for up to 12 DIGITAL SCSI-2 devices. Up to two HSD30 array controllers may be daisy chained together on a single DSSI interconnect. A combined maximum of up to 7 DSSI targets may reside on the same DSSI bus. The DSSI targets include: HSD30 array controllers, TF tapes, RF drives, and HSD10 devices. The tri-link and bus terminator are shipped with the HSD30 array controllers. HSD30 array controllers standard features include RAID 0 and support 16- or 32 MB read cache as an optional feature. Other optional features include Write-back Cache, Disk Mirroring (RAID Level 1), and Adaptive Raid 3/5. Features
Direct connection to the DSSI Bus Connection for up to 21 SCSI Devices, 7 SCSI devices per StorageWorks shelf Provides controller based striping (Raid 0) Optional Write-back Cache, Disk Mirroring (RAID Level 1) and Adaptive RAID 3/5.
Multihost operation, up to 3 hosts on the DSSI bus Supports a 60-foot maximum DSSI bus length with up to 16 feet between DSSI nodes Wide drives operate in 8-bit mode
SCSI 8-bit Devices Supported
RZ25, .426 MB 8-bit disk RZ26, 1.05 GB 8-bit disk RZ26L, 1.05 GB 8-bit disk RZ26N, 1.05 GB 8-bit disk (V2.0 or above) RZ28, 2.1 GB 8-bit disk RZ28B, 2.1 GB 8-bit disk RZ28D, 2.1 GB 8-bit disk (V2.0 or above) RZ28M, 2.1 GB 8-bit disk (V2.0 or above) RZ29B, 4.3 GB 8-bit disk (V2.0 or above) RZ40, 9.1 GB 8-bit disk RZ74, 3.57 GB 8-bit disk, 5.25” EZ51/54/58R SCSI solid state disks EZ64, solid state disk EZ69, solid state disk RRD42/43/44/45/46 optical devices
TLZ06/TLZ6L 4mm tape devices TLZ07/TLZ7L 4mm tape devices (V2.0 /V2.5 or above) TLZ09/TLZ9L 4mm tape drive & autoloader TZ86/87/87N tape devices TZ867/77/75 tape devices with loader TL820/810 DLT tape libraries TL812/822/826 DLT tape libraries TKZ60/61/62/63/64 tape devices TSZ07 reel to reel tape device RWZ52/53 optical devices RW524/525/530/531/532 optical juke boxes RW 546/551/552/555/557 optical juke boxes TZ88N tape device TZ885 tape drive loader TZ887 tape drive loader
SCSI 16-bit Drives Supported RZ26L-VW, 1.05 GB 16-bit disk (V2.7) DS-RZ1CB, 4.3 GB Ultra SCSI disk RZ26N-VW, 1.05 GB 16-bit disk (V2.7) DS-RZ1DB, 9.1 GB Ultra SCSI disk RZ28-VW, 2.1 GB 16-bit disk (V2.7) EZ31/32-VW, solid state disk RZ28D-VW, 2.1 GB 16-bit disk (V2.7) EZ64-VW, SCSI solid state disk RZ28M-VW, 2.1 GB 16-bit disk (V2.7) EZ69-VW, SCSI solid state disk RZ29B-VW, 4.3 GB 16-bit disk (V2.7) TZ89N DLT tape drive DS-RZ1BB, 2.1 GB Ultra SCSI disk TLZ893/894/896 DLT tape libraries Refer to HSOF Array Controller documentation for device restrictions.
Adapters Supported
KFESA/B, KFMSA, KFMSB, KFPSA, SHAC-based embedded, DEC 4000 embedded
Storage
7.38
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks HSD30 DSSI to FSE SCSI-2 Array Controller (21 Devices) (continued) StorageWorks Environments Supported BA35X-MH BA356-SC BA35X-MG BA35X-HF BA350-MA/MB
16-bit module for BA356 Shelf, no personality module (V2.7 required) 8-bit module for BA356 (V2.7 required) 150 Watt 48 volt power supply Storage controller shelf
BA350-JA SW300-AA
Storage BA350-SA shelf kit StorageWorks mini cabinet
SW500-AC/AD
StorageWorks departmental cabinet
SW800-AA/AB
StorageWorks data center cabinet
Operating System Support OpenVMS VAX Version 5.5-2 or greater and OpenVMS Alpha V6.1 or greater (or mixed clusters) support the HSD30 with limitations. The limitations are the devices being identified as generic or unknown device types. The model type identifiers are not present in the operating system software. In addition, complete error log decoding is not provided under ERF. Device/Option Capabilities
Supported - Up to seven disk storage devices on same SCSI bus from HSD30 - Up to two tape storage devices on same SCSI bus from HSD30 - Two solid-state storage devices on SCSI bus from HSD30 - Up to two tapes and two disks or one tape and five disk devices on a SCSI bus from HSD30
- Redundant configurations of two HSD30 on same, or separate, DSSI bus providing controller failover - Tri-host DSSI clusters - Use of devices attached to the HSD30 as boot device on VAX 7000/10000 processors provided the VAX 7000/10000 console code is at V4.0 or higher. - Use of devices attached to the HSD30 as boot device on DEC 7000/10000 systems provided the DEC 7000/10000 console code is at V3.1 or higher.
Not Supported - Combined use of HSD30 and DWZZA/DWZZB adapters - More than two HSD30 on same DSSI bus
Recommendation For optimal performance operate the HSD30 at a maximum of 80% utilization. This will allow for optimal performance with workload peaks. If an HSD30 is more than 80% utilized, order an additional controller and host adapter. Ordering Information HSD30-CA HSD30-CD HSD30-CD HSD30-CF HSD30-XD HSD30-XF HSD30-XE HSD30-YC HSD30-YX QL-4DRA9-AA QL-3HYA9-AA
StorageWorks Array Controller, 18 dual redundant or 21 nonredundant SCSI-2 disk, tape, SSD, optical device support; RAID 0, base firmware and license StorageWorks Array Controller, 18 dual redundant or 21 nonredundant SCSI-2 disk, tape, SSD, optical device support; RAID 0, 16 MB cache, base firmware and license StorageWorks Array Controller, 18 dual redundant or 21 nonredundant SCSI-2 disk, tape, SSD, optical device support; RAID 0, 32 MB cache, base firmware and license StorageWorks Array Controller, 18 SCSI-2 disk, tape, SSD, optical device support; RAID 0, 32 MB cache, base firmware and license 16 MB read cache option for HSD30-AA 32 MB read cache option for HSD30-AA, 32 MB total 16 MB read cache option for HSD30-AD, 32 MB total, mandatory return of installed 16 MB cache Write-back cache batteries and bracket` HSD30 Write-back Cache Option., license and batteries HSD30 Disk Mirroring license HSD30 RAID license
Storage
7.39
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks HSD30 DSSI to FSE SCSI-2 Array Controller (21 Devices) (continued) StorageWorks Cables for the HSD30 BC29S-xx BC29R-xx BC29T-03 BC29T-09 BC29U-02 BC29V-01 BC29V-06 BC29V-16
Storage
7.40
DSSI cable to VAX or DEC 7000, 10000 Alpha systems to HSD DSSI cable to VAX or DEC 4000 Alpha systems to HSD 3-foot DSSI cable horizontal shelf to vertical shelf link for shelves on same side of cab to HSD 9-foot DSSI cable horizontal shelf to vertical shelf link for shelves that have one in front and one in back to HSD 2-foot DSSI cable horizontal shelf to horizontal shelf link for shelves on same side of cab to HSD 1-foot DSSI cable StorageWorks HSD30 to HSD30 cable for when DSSI bus is continued from HSD30 to HSD30 in same StorageWorks shelf HSD 6-foot DSSI cable StorageWorks pedestal to pedestal cable for when DSSI bus is continued from pedestal to pedestal HSD 16-foot DSSI cable StorageWorks pedestal to pedestal cable for when DSSI bus is continued from pedestal to pedestal HSD
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks HSD10 DSSI to FSE SCSI-2 Array Controller (7 Devices) StorageWorks HSD10 array controller expands DSSI support in the StorageWorks family of products. It connects to a single port on the DSSI bus providing connectivity for up to seven non-redundant SCSI-1 or SCSI-2 devices. It allows users the flexibility to expand the amount of DSSI-connected storage devices or to free up DSSI nodes for host connections. The inclusion of 16 or 32 MB of read cache can significantly improve disk I/O performance. The HSD10 replaces the HSD05 array controller. HSD10 array controller is housed in a 3.5-inch StorageWorks System Building Block; it mounts in a BA356-SB shelf, or a BA356-KA StorageWorks Deskside Expansion Unit, along with up to six SCSI devices. The StorageWorks shelves may be mounted in the SW500 or SW800. A tri-link connector and a bus terminator are shipped with the HSD10. The maximum DSSI bus length is 60 feet. Two HSD10 array controllers may be used in conjunction with separate DSSI buses to provide device access with no single point-of-failure. Features
Direct connection to the DSSI Bus Provides controller based Raid 0 (striping) Multihost operation; up to four hosts on the DSSI bus Up to 1000 I/O requests per second and 3.0 MB/second
Attached disks can be warm-swapped 16 or 32 MB of read cache Connection to a VCS console via RS communications port
SCSI Devices Supported
RZ26, 1.05 GB disk RZ26L, 1.05 GB disk RZ28, 2.1 GB disk RZ28B, 2.1 GB disk RZ28D, 2.1 GB disk RZ28M, 2.1 GB disk RZ29B, 4.3 GB disk RZ40, 9.1 GB disk RZ73, 2.1 GB disk RZ74, 3.6 GB disk EZ51R, 107 MB SCSI solid state disk
EZ54R, 428 MB SCSI solid state disk TLZ06, 4mm tape device 4 GB TLZ6L, 4mm tape device with loader 16 GB TLZ07, 4mm tape device 8 GB TLZ7L, 4mm tape device with loader 32 GB TLZ9L/TLZ09 4mm tape drive & autoloader TZ86, 6 GB tape device TZ87, 10 GB DLT tape drive RRD43/44/45/46/46, 600 MB optical devices (read only) TZ88, 20 GB DLT tape drive
Adapters Supported
EDA670, KFDDA/B, KFMSA, KFMSB, KFQSA, KFESA
StorageWorks Environments Supported BA356-SB BA356-KC BA356-SC SW500-AC/AD SW800-AA/AB
Storage shelf assembly, SCSI-2 compliant Storage Deskside Expansion Unit Shelf, no personality module StorageWorks departmental cabinet StorageWorks data center cabinet
Operating System Support OpenVMS VAX Version V5.5-2, V6.0, and OpenVMS Alpha V6.1 or greater Device/Option Capabilities
Supported - Up to six non-redundant disk storage devices (hard disk or solid state disk) on same SCSI bus from HSD10 - Up to two tape storage devices on same SCSI bus from HSD10 - Two solid-state storage devices on SCSI bus from HSD10 - Up to two tapes and two disks or one tape and five disk devices on a SCSI bus from HSD10 Not Supported - Combined use of HSD10 and DWZZA adapters Storage
7.41
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks HSD10 DSSI to FSE SCSI-2 Array Controller (7 Devices) (continued) Device/Option Capabilities
Supported - Up to six non-redundant disk storage devices (hard disk or solid state disk) on same SCSI bus from HSD10 - Up to two tape storage devices on same SCSI bus from HSD10 - Two solid-state storage devices on SCSI bus from HSD10 - Up to two tapes and two disks or one tape and five disk devices on a SCSI bus from HSD10 Not Supported - Combined use of HSD10 and DWZZA adapters
Recommendation For optimal performance operate the HSD10 at a maximum of 80% utilization. This will allow for optimal performance with workload peaks. If an HSD10 is more than 80% utilized, order an additional controller. For optimum performance, tape drives must be mounted on a separate bus from disk drives. Ordering Information HSD10-AA HSD10-AD HSD10-AF
StorageWorks Array Controller StorageWorks Array Controller with 16 MB read cache StorageWorks Array Controller with 32 MB read cache
StorageWorks Cables for the HSD10 BC29R-xx BC29S-xx BC29T-03 BC29T-09 BC29U-02 BC29V-06 BC29V-16
Storage
7.42
DSSI cable to VAX or DEC 4000 systems to HSD (06, 09, 16, 30 ft) DSSI cable to VAX or DEC 7000, 10000 systems to HSD DEC 2000, 2100, VAX 6000, VAX/DEC 7000, VAX/DEC 10000 (06, 09, 16, 30 ft) 3-foot DSSI cable, horizontal shelf to vertical shelf link for shelves on same side of cab to HSD 9-foot DSSI cable, horizontal shelf to vertical shelf link for use with shelves that have one in back of cabinet to HSD 2-foot DSSI cable, horizontal shelf to horizontal shelf link for use when shelves are on same side of the cabinet to HSD 6-foot DSSI cable, StorageWorks pedestal to pedestal cable 16-foot DSSI cable, StorageWorks pedestal to pedestal cable
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks KZESC EISA to FSE SCSI-2 Array Controller StorageWorks RAID Array 210 subsystem is a hardware-based RAID subsystem for Alpha and Intel system platforms that use the industry-standard EISA bus. It provides RAID levels 0 (striping), 1 (shadowing), 0+1 (striped shadowed sets), and 5 (striping with distributed parity). By providing RAID functionality, it binds a collection of disk drives into a smaller number of logical drives to provide data redundancy and/or increased performance. Performance improvements are obtained by striping user data across a number of disk drives, thus overlapping disk operations (RAID 0, 0+1). Redundancy is obtained by keeping additional copies of user data on a redundant disk drive (RAID 1), or by generating and storing data parity so that user information can be reconstructed in the event of a disk failure (RAID 5). In either case, the application continues to run without data loss in the event of a single disk drive failure. For more information on RAID, see the Buyer’s Guide to RAID Systems (EC-G4136-45). StorageWorks RAID Array 210 subsystem comprises a RAID controller, RAID software (drivers and utilities) and documentation, and disk drives with appropriate cables and enclosures. SWXCR-Ex controller provides RAID functionality. It is an EISA backplane controller, and plugs directly into the EISA bus inside system enclosure. Therefore, RAID functionality can be provided for the disk drives inside, as well as outside, the system enclosure. In a standalone RAID subsystem, the disks are housed in separate StorageWorks pedestal enclosures. The combination of an EISA adapter and a RAID controller (as a single component) provides a lower-cost solution than traditional standalone RAID controllers. The SWXCR-Ex controller is available in two models, a single SCSI channel variant that supports up to 7 disk drives, and a three channel model that supports up to 21 drives. RAID software includes device drivers, standalone, and on-line utilities which provide following functionality:
EISA bus configuration RAID subsystem configuration (display drive array map, bind disks into RAID sets, configure array parameters, etc.) RAID subsystem monitoring and fault reporting. Status changes are reported to OPCOM (OpenVMS), System Console (DIGITAL UNIX), Event Viewer (Windows NT); written to a log file (DIGITAL UNIX and OpenVMS); and notification can be sent via MAIL (OpenVMS) RAID subsystem maintenance (parity check and repair, firmware updates)
The hardware components of StorageWorks RAID Array 210 subsystem are standard StorageWorks components. This includes disk drives as well as enclosures. Many of the redundancy attributes of StorageWorks RAID Array 210 subsystem, such as disk drive, power supply, and fan hot swapping, are standard StorageWorks attributes. Supported Systems StorageWorks RAID Array 210 subsystem is supported on Alpha systems and Intel servers that use the industry-standard EISA bus. Software Support The StorageWorks RAID Array 210 subsystem is supported on OpenVMS, DIGITAL UNIX, and Windows NT 3.5.1 or later. Ordering Information StorageWorks RAID Array 210 Subsystem can be configured with disk drives inside system enclosure, or in standalone StorageWorks pedestal enclosures. StorageWorks RAID Array 210 Subsystems include:
SWXCR-Ex EISA-based RAID controller, Software and documentation kit; includes device drivers and RAID utilities for chosen system platform. Software documentation kits are bundled with the controllers. StorageWorks disk drives
Enclosures, as required, to house disks Cables to connect controller to disk drives Additional StorageWorks components (redundant power supplies, fans, etc.) StorageWorks Raid Array 210 Subsystem
Storage
7.43
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks KZESC EISA to FSE SCSI-2 Array Controller (continued) Ordering Information KZESC-AA
KZESC-BA
CK-SWXCR-AA
BN21H-02 BC25R-3B
One port EISA-based RAID controller for Alpha Platforms. Provides one SCSI port through standard 50-pin EISA card connector. Includes StorageWorks RAID Array 200 Subsystem Family Software and Documentation Kit for Open VMS, DIGITAL UNIX, and Windows NT, 4 MB cache. Requires SCSI cable. Three port EISA-based RAID controller for Alpha Platforms. Provides three SCSI ports. One SCSI port is available through standard 50-pin EISA card connector. All three SCSI ports are available on module via standard 50-pin connectors. Includes StorageWorks RAID Array 200 Subsystem Family Software and Documentation Kit for Open VMS, DIGITAL UNIX, and Windows NT, 4 MB cache. Requires SCSI cables. Cable and bulkhead connector kit for KZESC-BA. Includes 0.3-meter (1-foot), internal “Y” cable (17-03998-01) which connects two SCSI ports from controller module to one 68-pin bulkhead connector. Note: 68-pin bulkhead connector is attached to a standard PC connector mounting plate (74-48600-01). AlphaServer 2100 mounting plate (70-47879-03) is also included. Kit also includes external “Y” SCSI cable (17-04000-01) which connects 68-pin bulkhead connector to two 1.7-meter SCSI cables with 50-pin connectors. Use to connect to two external pedestal enclosures. 2-meter SCSI cable. Connects 50-pin EISA card connector to SCSI device enclosure (disk pedestal/cabinet). 38-inch 50 Pos female to 50 Pos female SCSI cable assembly (17-03948-01) for SCSI drives inside AlphaServer 2100 system enclosure. Use one per SCSI channel.
Drives Supported RAID Level
Physical Drives per logical drive
Usable Storage
Data Redundancy
Max. # of Drives KZESC-AA
Max. # of Drives KZESC-BA
0 1 0+1 5 JBOD
2-8 2 3-8 3-8 1
All 50% 50% 66%-87% All
No Yes Yes Yes No
7 6 7 7 7
21 16 21 21 8
Specifications Technical Information System bus interface Controller form factor Supported RAID levels Supported drive channels Number of drive groups (logical drives) suppported SCSI channels Number of disks supported per controller
Industry-standard EISA Industry-standard EISA card 0, 1, 0+1, 5, JBOD (“just a bunch of disks”) 1 or 3 SCSI channels per controller Up to 8 per controller each of which may manage up to 32GB of addressable storage (exclusive of parity if applicable). SCSI-2, 8-bit, Single-Ended, Fast (10 MB/second) Up to 7 per SCSI channel: SWXCR-EA = 7 disk drive maximum SWXCR-EB = 21 disk drive maximum Note: Subject to RAID level and group restrictions
Non-RAID device support Non-Disk device support
Yes, disk drives (JBOD) Yes, tape drives and CD drives (Windows NT, Novell Netware, SCO UNIX)
Drives supported
2.1 GB, Narrow SCSI-2 FSE; DS-RZ28L-VA 4.3 GB, Narrow SCSI-2 FSE, DS-RZ29L-VA 9.4 GB, Narrow SCSI-2 FSE, DS-RZ40-VA 2.1 GB, Wide Ultra SCSI-2, DS-RZ1BB-VW 4.3 GB. Wide Ultra SCSI-2, DS-RZ1CB-VW 9.1 GB, Wide Ultra SCSI-2, DS-RZ1DB-VW
Storage
7.44
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks KZESC EISA to FSE SCSI-2 Array Controller (continued) Specifications (continued) Drive Reconstruct Disk hot swap Disk hot spare Redundant power supplies Redundant controllers Redundant fans Mixed drive types Mixed RAID levels within Drive Group Configurable reconstruct time Stripe size Write through cache Write back cache Boot capability Number of controllers/system
Cache support
Automatic Yes Yes Yes No Yes Yes Yes Yes 864 KB Yes, user selectable (default) Yes, user selectable (optional) Bootable from RAID set (system dependent) 4 RAID controllers in any combination of KZESC or KZPSC with OpenVMS, DIGITAL UNIX, Windows NT, or Novell NetWare are subject to specific CPU configuration limitations Yes (4 MB standard)
Storage
7.45
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks HSD50 Series DSSI Array Controller for OpenVMS Systems StorageWorks HSD50 array controller expands DSSI support in the StorageWorks family of products. Each HSD50 occupies one DSSI address location (there are 8 addresses per DSSI bus) on the DSSI bus providing connectivity for up to 42 SCSI devices. The HSD50 allows customers to significantly expand the number of DSSI-connected storage devices. HSD50 array controller features a StorageWorks controller shelf compatible form factor. It can be installed in StorageWorks SW500 or SW800 cabinets, controlling up to 42 DIGITAL SCSI-2 devices, connected to up to six SCSI ports. It can also be installed in the SW300 cabinet which allows connection for up to 24 DIGITAL SCSI-2 devices. Up to two HSD50 array controllers may be daisy-chained together on a single DSSI interconnect. A combined maximum of up to 7 DSSI targets may reside on the same DSSI bus. The DSSI targets include: HSD50 array controllers, TF tapes, RF drives, and HSD10 devices. The tri-link and bus terminator are shipped with the HSD50 array controllers. HSD50 array controllers standard features include RAID 0 and 1, and Adaptive RAID 3/5, 32 MB write-back cache, disk partitioning and all licenses. The HSD50 may be configured as a redundant pair of controllers providing multi-host bus connection. This high availability option eliminates all single points of failure between storage devices and host CPUs. Features
Direct connection to the DSSI Bus Connection for up to 42 SCSI Devices, 7 SCSI devices per StorageWorks shelf Multihost operation, up to 3 hosts on the DSSI bus Redundant configuration with multi-host bus failover. Supports a 60-foot maximum DSSI bus length with up to 16 feet between DSSI nodes Wide drive operate in 8-bit mode Highest performance DSSI controller with 1700 QIOs/sec and 3.4 MB/sec bandwidth Supports disks, tape, and solid state disks
For easy ordering, standard features include RAID levels 0, 1 and Adaptive RAID 3/5, 32 MB write-back cache, disk partitioning and all licenses Optional 64 and 128 MB write-back cache enhances performance Simm packs on cache modules allow easy field upgrades External cache battery in SBB allows visual monitoring and easy replacement Upgrade program from HSD30 to HSD50 HSOF software now ordered separately with each controller
SCSI 8-bit Devices Supported
RZ25, .426 MB 8-bit disk RZ26, 1.05 GB 8-bit disk RZ26L, 1.05 GB 8-bit disk RZ26N, 1.05 GB 8-bit disk (V2.0 or above) RZ28, 2.1 GB 8-bit disk RZ28B, 2.1 GB 8-bit disk RZ28D, 2.1 GB 8-bit disk (V2.0 or above) RZ28M, 2.1 GB 8-bit disk (V2.0 or above) RZ29B, 4.3 GB 8-bit disk (V2.0 or above) RZ40, 9;1 GB disk RZ74, 3.57 GB 8-bit disk, 5.25” EZ51/54/58R SCSI solid state disks EZ64, solid state disk EZ69, solid state disk RRD42/43/44/45/46 optical devices
TLZ06/TLZ6L 4mm tape devices TLZ07/TLZ7L 4mm tape devices TLZ09/TLZ9L 4mm tape drive & autoloader TZ86/87/87N DLT tape drives TZ867/877/875 tape devices with loader TL820/810 DLT tape library TL812/822/826 DLT tape libraries TKZ60/61/62/63/64 tape devices TSZ07 reel to reel tape device RWZ52/53 optical devices RW524/525/530/531/532 optical juke boxes RW 546/551/552/555/557 optical juke boxes TZ88N DLT tape drives TZ885 tape drive loader TZ887 tape drive loader
SCSI 16-bit Drives Supported
RZ26L-VW, 1.05 GB 16-bit disk (V2.7) RZ26N-VW, 1.05 GB 16-bit disk (V2.7) RZ28-VW, 2.1 GB 16-bit disk (V2.7) RZ28D-VW, 2.1 GB 16-bit disk (V2.7) RZ28M-VW, 2.1 GB 16-bit disk (V2.7) RZ29B-VW, 4.3 GB 16-bit disk (V2.7)
Storage
7.46
DS-RZ1BB; 2.1GB Ultra SCSI disk DS-RZ1CB; 4.3GB Ultra SCSI disk DS-RZ1DB; 9.1GB Ultra SCSI disk EZ31/32-VW, solid state disk EZ64-VW, SCSI solid state disk EZ69-VW, SCSI solid state disk
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks HSD50 Series DSSI Array Controller for OpenVMS Systems (continued) Tape Drives Supported TZ89 DLT Tape Drive TL893/894/896 DLT Tape Libraries Refer to HSOF Array Controller documentation for device restrictions.
Adapters Supported
KFESA/B, KFMSA, KFMSB, KFPSA, SHAC-based embedded, DEC 4000 embedded
StorageWorks Environments Supported BA35X-MH BA356-SC BA35X-MG BA35X-HF BA350-MA/MB BA350-JA SW300-AA SW500-AC/AD SW800-AA/AB
16-bit module for BA356 Shelf, no personality module (V2.7 required) 8-bit module for BA356 (V2.7 required) 150 Watt 48 volt power supply Storage controller shelf Storage BA350-SA shelf kit StorageWorks mini cabinet StorageWorks departmental cabinet StorageWorks data center cabinet
Operating System Support OpenVMS VAX Version 5.5-2 or higher and OpenVMS Alpha V6.1 or higher (or mixed clusters) support the HSD50 with limitations. The limitations are the devices being identified as generic or unknown device types. The model type identifiers are not present in the operating system software. In addition, complete error log decoding is not provided under ERF. Device/Option Capabilities
Supported - Up to seven disk storage devices on same SCSI bus from HSD50 - Up to two tape storage devices on same SCSI bus from HSD50 - Two solid-state storage devices on SCSI bus from HSD50 - Up to two tapes and two disks or one tape and five disk devices on a SCSI bus from HSD50
- Redundant configurations of two HSD50 on same, or separate, DSSI bus providing controller failover - Tri-host DSSI clusters - Use of devices attached to the HSD30 as boot device on VAX 7000/10000 processors provided the VAX 7000/10000 console code is at V4.0 or higher. - Use of devices attached to the HSD30 as boot device on DEC 7000/10000 systems provided the DEC 7000/10000 console code is at V3.1 or higher.
Not Supported - Combined use of HSD50 and DWZZA/B - More than two HSD50 on same DSSI bus HSD50 Single controller with single external cache battery. Order HSOF software kit separately below. Supports up to 42 drives. HSD52 Two HSD50 controllers for use in a dual redundant configuration with dual external cache batteries. Order 2 HSOF software kits separately. Supports up to 36 drives.
Storage
7.47
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks HSD50 Series DSSI Array Controller for OpenVMS Systems (continued) Ordering Information HSD50-AF HSD50-AH HSD50-AJ HSD52-AF HSD52-AH HSD52-AJ HSD5X-AA HSD5X-AD HSD5X-AF QB-5C5AA-SA HSSIM-AA
StorageWorks 6-channel DSSI controller, 32MB write-back cache StorageWorks 6-channel DSSI controller, 64MB write-back cache StorageWorks 6-channel DSSI controller, 128MB write-back cache StorageWorks dual 6-channel DSSI controller, 32MB write-back cache StorageWorks dual 6-channel DSSI controller, 64MB write-back cache StorageWorks dual 6-channel DSSI controller, 128MB write-back cache HSD50-AF upgrade for HSD30-AA/CA HSD50-AD upgrade for HSD30-AD/CD HSD50-AF upgrade for HSD30-AF/CF HSOF software/license for one HSD50 controller 32MB SIMM pack for HSD50/HSJ50 cache upgrade
StorageWorks Cables for the HSD50 BC29S-xx BC29R-xx BC29T-03 BC29T-09 BC29U-02 BC29V-01 BC29V-06 BC29V-16
Storage
7.48
DSSI cable to VAX or DEC 7000, 10000 Alpha systems to HSD DSSI cable to VAX or DEC 4000 Alpha systems to HSD 3-foot DSSI cable horizontal shelf to vertical shelf link for shelves on same side of cab to HSD 9-foot DSSI cable horizontal shelf to vertical shelf link for shelves that have one in front and one in back to HSD 2-foot DSSI cable horizontal shelf to horizontal shelf link for shelves on same side of cab to HSD 1-foot DSSI cable StorageWorks HSD30 to HSD30 cable for when DSSI bus is continued from HSD30 to HSD30 in same StorageWorks shelf HSD 6-foot DSSI cable StorageWorks pedestal to pedestal cable for when DSSI bus is continued from pedestal to pedestal HSD 16-foot DSSI cable StorageWorks pedestal to pedestal cable for when DSSI bus is continued from pedestal to pedestal HSD
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks HSJ50 Series CI Array Controller StorageWorks HSJ50 subsystems improve CI support to the StorageWorks family. These subsystems interface directly to the CI Star Coupler to provide scalability and customer-defined SCSI-2 storage capacity with high performance and availability. HSJ50 array controller features a StorageWorks controller shelf compatible form factor. It can be installed in StorageWorks SW500 or SW800 cabinets, controlling 36 DIGITAL SCSI-2 devices in a dual redundant configuration and 42 devices in a single controller configuration. The HSJ50 must be connected utilizing the star coupler. HSJ50 array controller has a 32MB of cache as a standard feature. HSOF software is purchased separately (see ordering information) and includes 1 PCMCIA card, licenses for RAID 1, RAID 3/5 and write back cache. The HSJ50 may be configured as a redundant pair of controllers providing multi-host bus connection. This high availability option eliminates all single points of failure between storage devices and host CPUs. Features
Direct connection to CI— channel card functionality included Performance increased to over the HSJ40 Array Controller to 4600 I/O per second and 12.7MB/sec, the highest for the CI platform Write-back cache design supports 32, 64, or 128 MB of SIMMS pack memory, assuring maximum performance for today’s and tomorrow’s large capacity disks RAID 0,1,3/5 levels and write-back cache are standard features of HSOF V5.1 for easy ordering Disk partitioning is a new standard feature that lets you create logical disk drives and guarantees dedicated disk capacity for users and applications
External cache battery allows visual health checking and easy operator replacement of the cache battery HSOF software is now ordered separately from the controller Optional controller redundancy with automatic failover and redundant power StorageWorks packaging for maximum configuration flexibility Wide drive ready support (controller operates in 8-bit mode)
HSJ50 Array Controllers The expanded family of HSJ50 Array subsystems provides scaleable solutions for OpenVMS CI Clusters. For all models, storage device support includes a broad and increasing range of disk, tape, solid state disk and optical alternatives. HSOF V5.1software includes standard RAID 0 (striping), Disk Mirroring (Raid 1) and Adaptive RAID 3/5 and write-back cache license. Disk partioning is also a standard feature. For high availability and performance, HSJ50 Array Controllers may be deployed in dual-redundant configurations for dual-path access with automatic failover. Up to 128 MB of Read Cache is available on each Array Controller. Device support has been expanded to include the following storage devices. SCSI 8-bit Devices Supported
RZ25, .426 MB 8-bit disk RZ26, 1.05 GB 8-bit disk RZ26L, 1.05 GB 8-bit disk RZ26N, 1.05 GB 8-bit disk (V2.0 or above) RZ28, 2.1 GB 8-bit disk RZ28B, 2.1 GB 8-bit disk RZ28D, 2.1 GB 8-bit disk (V2.0 or above) RZ28M, 2.1 GB 8-bit disk (V2.0 or above) RZ29B, 4.3 GB 8-bit disk (V2.0 or above) RZ40, 9.1-Gbtye 8-bit disk RZ74, 3.57 GB 8-bit disk, 5.25” EZ51/54/58R SCSI solid state disks EZ64, solid state disk EZ69, solid state disk RRD42/43/44/45/46 optical devices
TLZ06/TLZ6L 4mm tape devices TLZ07/TLZ7L 4mm tape devices (V2.0 /V2.5 or above) TLZ09/TLZ9L 4mm tape drive & autoloader TZ86/87/87N tape devices TZ867/77/75 tape devices with loader TL820/810 DLT tape libraries TL812/822/826 DLT tape libraries TKZ60/61/62/63/64 tape devices TSZ07 reel to reel tape device RWZ52/53 optical devices RW524/525/530/531/532 optical juke boxes RW 546/551/552/555/557 optical juke boxes TZ88N tape device TZ885 tape drive loader TZ887 tape drive loader
Storage
7.49
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks HSJ50 Series CI Array Controller (continued) 16-bit Wide SCSI Drives Supported
RZ28-VW, 2.1 GB 16-bit disk (V2.7) RZ28D-VW, 2.1 GB 16-bit disk (V2.7) RZ29B-VW, 4.3 GB 16-bit disk (V2.7) RZ26L-VW, 1.05 GB 16-bit disk (V2.7) RZ26N-VW, 1.05 GB 16-bit disk (V2.7) RZ28M-VW, 2.1 GB 16-bit disk (V2.7) SWXD3-WF, 1.05 GB 16-bit disk SWXD3-WG, 2.1 GB 16-bit disk SWXD3-WH, 2.1 GB 16-bit disk
SWXD3-WE, 4.3 GB 16-bit disk DS-RZ1BB; 2.1GB Ultra SCSI disk DS-RZ1CB; 4.3GB Ultra SCSI disk DS-RZ1DB; 9.1GB Ultra SCSI disk TZ89 DLT Tape Drive TL893/894/896 DLT Tape Libraries EZ31-VW, 0.134 GB solid disk device EZ32-VW, 0.268 GB solid disk device
Refer to HSOF Software SPD (60.68.00) for device restrictions. Adapters Supported
CIBCA, CIXCD, CIPCA
StorageWorks Environments Supported BA356-SC BA35X-MG BA35X-MH BA35X-HF BA350-MA/MB BBA350-JA BBA350-LA SSW500-AC/AD SSW800-AA/AB BBN21K-xx
Shelf, no personality module (V2.7 required) 8-bit module for BA356 (V2.7 required) 16-bit module for BA356 150 Watt 48 volt Power Supply Storage controller shelf Storage BA350-SA shelf kit Storage shelf assembly, for System Plug-in-unit (PIU) StorageWorks departmental cabinet StorageWorks data center cabinet FWD-SCSI Host Interconnect Cabling
HSJ50—HSJ50 Array Controller supports up to 36 SCSI-2 devices in dual redundant mode, 42 in single mode. Internal performance is 4600 I/O per second. Fast response time requirements are met by the standard 32 MB Read Cache (expandable to 128 MB). Write-Back Cache options may improve performance times. Includes single external cache battery. Order HSOF Software kit separately. HSJ52—Packaged as a dual-redundant HSJ50 configuration, the HSJ52 provides support for a maximum of 36 storage devices per controller in high performance/availability subsystem. Includes dual external cache battery. Order 2 HSOF Software kits separately. HSJ54—The HSJ54 contains two dual-redundant HSJ52s, supporting tape, solid state disk, and optical devices. Includes 2 dual external cache batteries. Order 4 HSOF software kits separately. Operating System Support HSJ-series controller subsystems supported by OpenVMS VAX V5.5-2 and greater; and OpenVMS Alpha V6.1 or greater
Storage
7.50
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks HSJ50 Series CI Array Controller (continued) Ordering Information HSJ50-AF HSJ50-AH HSJ50-AJ HSJ52-AF HSJ52-AH HSJ52-AJ HSJ54-AJ HSJ5X-AD HSJ5X-AF QB-5C4AA-SA HSSIM-AA HS35X-BA HS35X-BB
StorageWorks 6-channel CI controller, 32MB WB cache StorageWorks 6-channel CI controller, 64MB WB cache StorageWorks 6-channel CI controller, 128MB WB cache StorageWorks dual 6-channel CI controller, 64MB WB cache StorageWorks dual 6-channel CI controller, 128MB WB cache StorageWorks dual 6-channel CI controller, 256MB WB cache StorageWorks dual 6-channel CI controller, 512MB WB cache HSJ50-AF upgrade for HSJ40-AD/CD HSJ50-AF upgrade for HSJ40-AF/CF HSOF software and .license for one HSJ controller 32 MB SIMM pack for HSD50 and HSJ50 Single external cache battery in one SBB Dual eternal cache battery in one SBB
Storage
7.51
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks HSZ50 Series CI Array Controller HSZ50 controller series has been designed with new components and HSOF software to provide superior levels of performance in the HSZ50-series of controllers. Designed for open SCSI computing environments, write-back cache, RAID, disk mirroring and partitioning, and the StorageWorks Command Console are now standard features of the HSOF controller software package. Competitively priced, the HSZ50-series also features an easy upgrade process for existing HSZ40 customers. The HSZ50 controllers can be configured as redundant paths to provide high availability management of subsystems. Features
HSZ50 dual-redundant configurations can deliver improved I/O and Bandwidth performance. 32MB of standard onboard controller cache Easy cache expansion to 128MB with 32 MB SIMMS packs Easy upgrade program for HSZ40-series
New HSOF controller software warranty and ordering process Standard features include Adaptive RAID 3/5, write back cache, disk mirroring, disk partitioning, the StorageWorks Command Console, and a new graphical user interface A new externally mounted cache battery in SBB
HSZ50 Array Controllers The expanded family of HSZ50 Array subsystems provide, scaleable solutions for OpenVMS and DIGITAL UNIX customers. For all models, storage device support includes a broad and increasing range of disk, tape, solid state disk and optical alternatives. HSOF V5.1 software includes standard RAID 0 (striping), Disk Mirroring (Raid 1) and Adaptive RAID 3/5 and write-back cache license. For high availability and performance, HSZ50 Array Controllers may be deployed in dual-redundant configurations, with automatic failover. Up to 128 MB of Read Cache is available on each Array Controller. Device support has been expanded to include the following storage devices. SCSI 8-bit Devices Supported
RZ25, .426 MB 8-bit disk RZ26, 1.05 GB 8-bit disk RZ26L, 1.05 GB 8-bit disk RZ26N, 1.05 GB 8-bit disk (V2.0 or above) RZ28, 2.1 GB 8-bit disk RZ28B, 2.1 GB 8-bit disk RZ28D, 2.1 GB 8-bit disk (V2.0 or above) RZ28M, 2.1 GB 8-bit disk (V2.0 or above) RZ29B, 4.3 GB 8-bit disk (V2.0 or above) RZ40, 9.1-Gbtye 8-bit disk
RZ74, 3.57 GB 8-bit disk, 5.25” EZ51/54/58R SCSI solid state disks EZ64/69 solid state disks RRD42/43/44/45/46 optical devices TZ87/87N tape devices TZ877/75 tape devices with loader TL812/822/826 DLT tape libraries TZ88N tape device TZ885/887 DLT tape libraries
16-bit Wide SCSI Drives Supported
RZ28-VW, 2.1 GB 16-bit disk (V2.7) RZ28D-VW, 2.1 GB 16-bit disk (V2.7) RZ29B-VW, 4.3 GB 16-bit disk (V2.7) RZ26L-VW, 1.05 GB 16-bit disk (V2.7) RZ26N-VW, 1.05 GB 16-bit disk (V2.7) RZ28M-VW, 2.1 GB 16-bit disk (V2.7) SWXD3-WF, 1.05 GB 16-bit disk SWXD3-WG, 2.1 GB 16-bit disk SWXD3-WH, 2.1 GB 16-bit disk
SWXD3-WE, 4.3 GB 16-bit disk DS-RZ1BB; 2.1GB Ultra SCSI disk DS-RZ1CB; 4.3GB Ultra SCSI disk DS-RZ1DB; 9.1GB Ultra SCSI disk TZ89 DLT Tape Drive TL893/894/896 DLT Tape Libraries EZ31-VW, 0.134 GB solid disk device EZ32-VW, 0.268 GB solid disk device
Refer to HSOF Software SPD (61.36.02) for device restrictions. Adapters Supported
KZMSA, KZPSA, KZTSA, PMAZC, KZPAA, KFTIA (OpenVMS only)
Storage
7.52
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks HSZ50 Series CI Array Controller (continued) StorageWorks Environments Supported BA350-SA/SB BA356-SC BA35X-MG BA35X-HF BA350-MA/MB BA350-JA BA350-LA SW500-AC/AD SW800-AA/AB BN21K-xx SW300
Storage shelf assembly Shelf, no personality module (V2.7 required) 8-bit module for BA356 (V2.7 required) 150 Watt 48 volt Power Supply Storage controller shelf Storage BA350-SA shelf kit Storage shelf assembly, for System Plug-in-unit (PIU) StorageWorks departmental cabinet StorageWorks data center cabinet FWD-SCSI Host Interconnect Cabling StorageWorks Mini Cabinet
HSZ50—HSZ50 Array Controller supports up to 36 SCSI-2 devices in dual redundant with a 32 LUN maximum mode, 42 in single mode. Internal performance is 4600 I/O per second. Fast response time requirements are met by the standard 32 MB Read Cache (expandable to 64 or 128 MB). Includes single external cache battery. Order HSOF Software kit separately. HSZ52—Packaged as a dual-redundant HSZ50 configuration, the HSZ52 provides support for a maximum of 36 with a 32 LUN maximum storage devices per controller in high performance/availability subsystem. Includes dual external cache battery. Order 2 HSOF Software kits separately. HSZ54—The HSZ54 contains two dual-redundant HSZ52s, supporting tape, solid state disk, and optical devices. Includes 2 dual external cache batteries. Order 4 HSOF software kits separately. Operating System Support DIGITAL UNIX V3.2C, 3.2D, 3.2G, 4.0A, 4.0B, OpenVMS Alpha V6.2, V7.0, V7.1 Ordering Information HSZ50-AF HSZ50-AH HSZ50-AJ HSZ52-AF HSZ52-AH HSZ52-AJ HSZ54-AJ HSZ5X-AA HSZ5X-AD HSZ5X-AF QB-5C4JAA-SA HSSIM-AA HS35X-BA HS35X-BB
StorageWorks 32MB SCSI-II Controller StorageWorks 64MB SCSI-II Controller StorageWorks 128MB SCSI-II Controller 2; StorageWorks 64MB SCSI-II Controller 2;StorageWorks 128MB SCSI-II Controller 2; StorageWorks 256MB SCSI-II Controller 4; StorageWorks 512MB SCSI-II Controller 1 HSZ50-AF upgrade for HSZ40-AA,BA,CA 1 HSZ50-AF upgrade for HSZ40-AD,BD,CD 1 HSZ50-AF upgrade for HSZ40-AF,BF,CF HSOF V5.0 software license for single controller 32 MB SIMM pack for HSZ50 series controllers Single external cache battery in one SBB Dual eternal cache battery in one SBB
Storage
7.53
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks KZPSC RAID Array 230 Storage Controller StorageWorks RAID Array 230 subsystem is a hardware-based RAID solution for Alpha and Intel system platforms that use the industry-standard PCI bus. It provides RAID levels 0 (striping), 1 (mirroring), 0+1 (striped mirrored sets), and 5 (striping with distributed parity). By providing RAID functionality, it binds a collection of disk drives into logical drives to provide data redundancy and/or increased performance. Performance improvements are obtained by striping user data across a number of disk drives, thus overlapping disk operations (RAID 0, 0+1). Redundancy is obtained by keeping additional copies of user data on a redundant disk drive (RAID 1), or by generating and storing data parity so that user information can be reconstructed in the event of a disk failure (RAID 5). In either case, the application continues to run without data loss in the event of a single disk drive failure. For more information on RAID, see the Buyer's Guide to RAID Systems(EC-G4136-45). The StorageWorks RAID Array 230 subsystem comprises a PCI backplane RAID controller, operating system specific RAID drivers and utilities (software), documentation, and disk drives with appropriate cables and enclosures. The controller provides RAID functionality. It is a backplane controller, and plugs directly into PCI bus inside system enclosure. Therefore, RAID functionality can be provided for disk drives inside, as well as outside, system enclosure. In a standalone RAID subsystem, disks are housed in separate StorageWorks pedestal enclosures. The combination of a PCI adapter and a RAID controller (as a single component) provides a lower-cost solution than traditional standalone RAID controllers. The KZPSC controller is available in two models, a single SCSI channel variant that supports up to 7 disk drives, and a three channel model that supports up to 21 drives. RAID drivers and utilities provide the following functionality:
RAID subsystem configuration (display drive array map, bind disks into RAID sets, configure array parameters, etc.) RAID subsystem monitoring and fault reporting. Status changes are reported to OPCOM (OpenVMS), System Console (DIGITAL UNIX) Event Viewer (Windows NT); written to a log file (DIGITAL UNIX and OpenVMS); and notification can be sent via MAIL (OpenVMS). RAID subsystem maintenance (parity check and repair, firmware updates)
System Support The StorageWorks RAID Array 230 subsystem is supported on Alpha systems and Intel Servers that use the industrystandard PCI bus. Refer to system ordering menus. Operating System Support StorageWorks RAID Array 230 subsystem is supported on DIGITAL UNIX V3.0B, OpenVMS 6.2, and Windows NT V3.5/or later. Ordering Information StorageWorks RAID Array 230 Subsystem can be configured with disk drives inside system enclosure, or in standalone configurations, where the disk devices are contained in StorageWorks pedestal enclosures. StorageWorks RAID Array 230 Subsystem consists of the following key components:
PCI backplane RAID controller, which plugs-in directly into PCI system backplane. Software and documentation kit, which includes device drivers and RAID utilities for chosen system platform. (Software/Documentation kits are bundled with controllers).
Storage
7.54
StorageWorks disk drives Enclosures, as required, to house disks Cables to connect controller to disk drives Additional StorageWorks components (redundant power supplies, fans, etc.)
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks KZPSC RAID Array 230 Storage Controller (continued) Ordering Information (continued) KZPSC-AA
KZPSC-BA
MS100-AA MS100-AB KZPSC-UB
One port PCI-based RAID controller for Alpha Platforms. Provides one FWSE SCSI channel through a 68-pin HD connector on module, for internal connection, or via an 0.8 mm 68 pin connector on the module's standard PCI bulkhead for external connection. Includes StorageWorks RAID Array 230 Subsystem Family Software and Documentation Kit for DIGITAL UNIX, Open VMS, and Windows NT, 4 MB Cache. Requires SCSI cable. Three port PCI-based RAID controller for Alpha Platforms. Provides three FWSE SCSI channels through 68-pin HD connectors on module, for internal connection. For external connection, two of the channels are available through 0.8 mm 68 pin connectors on module's standard PCI bulkhead; third channel can be connected to an 0.8 mm 68-pin connector on a standard PCI bulkhead connector via an adapter cable (BN31K-0E). Includes StorageWorks RAID Array 230 Subsystem Family Software and Documentation Kit for DIGITAL UNIX, Open VMS, and Windows NT, 4 MB cache. Requires SCSI cables. 16 MB Cache memory for KZPSC and KZESC. 16 MB, 4 Mx36, 70ns, 72 pin, Industry standard SIMM (54-23170-AA). Replaces 4 MB SIMM on KZPSC and KZESC backplane RAID controller 32 MB Cache memory for KZPSC and KZESC. 32 MB, 8 Mx36, 70ns, 72 pin, Industry standard SIMM (54-21277-AA). Replaces 4 MB SIMM on KZPSC and KZESC backplane RAID controller Battery backup for KZPSC cache memory. Provides up to 20 hours of memory retention for 4 MB of cache memory.
SCSI cables and Builkhead connectors BN31K-0E
KZPAC-SB
BN31L-1E
BN31M-1E
BN31S-1E
SCSI cable and bulkhead assembly for internal connection from KZPSC-BA module to system cabinet bulkhead (17-04108-01). Use to connect KZPSC-BA 3rd SCSI channel to system bulkhead. 16 bit capable - 0.5m Dual bulkhead assembly kit. Allows the third channels from two PCI backplane RAID controllers, in any combination of KZPSC or KZPAC, to share one additional PCI bulkhead assembly, thereby saving a bulkhead slot in comparison to utilizing two BN31K-0Es. External 1.5 m, 8-bit SCSI-2 cable. (17-04107-01). Connects 0.8 mm 68-pin HD connector from PCI bulkhead connector to 50-pin HD SCSI connector on StorageWorks 8-bit device enclosure. Use one for each KZPSC external SCSI channel. External 1.5 m, 16-bit SCSI-2 cable (17-04107-02). Connects 0.8 mm 68-pin HD connector from PCI bulkhead connector to 68-pin HD SCSI connector on StorageWorks 16-bit enclosure (BA364), or to second 68-pin HD SCSI connector on a BA356, StorageWorks 16-bit enclosure, I/O personality module (BA35X-MH), in split-bus configurations. Use one for each KZPSC external SCSI channel. External 1.5 m, 16-bit SCSI-2 cable (17-04107-03). Connects 0.8 mm connector from the PCI bulkhead to primary 68-pin HD SCSI connector on a BA356, StorageWorks 16-bit enclosure, I/O personality module (BA35X-MH). Use one for each KZPSC external SCSI channel.
Drives supported RAID Level
Physical Drives per logical drive
Usable Storage
Data Redundancy
0 1 0+1 5 JBOD
2-8 2 3-8 3-8 1
All 50% 50% 66%-87% All
No Yes Yes Yes No
Max. Number drives Max. Number drives KZPSC-AA KZPSC-BA
7 6 7 7 7
21 16 21 21 8
Storage
7.55
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks KZPSC RAID Array 230 Storage Controller (continued) Specifications System bus interface Controller form factor Supported RAID levels Supported drive channels Number of drive groups (logical drives) supported SCSI channels Number of disks supported per controller
Industry-standard PCI Industry-standard PCI card 0, 1, 0+1, 5, JBOD (“just a bunch of disks”) 1 or 3 SCSI channels per controller Up to 8 per controller each of which may manage up to 32GB of addressable storage (exclusive of parity if applicable.) SCSI-2, 8 and 16 bit, Single-Ended, Fast (10/20 MB/second) Up to 7 per SCSI channel: KZPSC-AA = 7 disk drives maximum KZPSC-BA = 21 disk drives maximum (See drive support table)
Non-RAID device support Non-Disk device support
Yes, disk drives (JBOD) Yes, Tape drives and CD drives (Windows NT V 3.5, Novell NetWare, SCO UNIX)
Drives supported
2.1 GB, Narrow SCSI-2 FSE; DS-RZ28L-VA 4.3 GB, Narrow SCSI-2 FSE, DS-RZ29L-VA 9.4 GB, Narrow SCSI-2 FSE, DS-RZ40-VA 2.1 GB, Wide Ultra SCSI-2, DS-RZ1BB-VW 4.3 GB. Wide Ultra SCSI-2, DS-RZ1CB-VW 9.1 GB, Wide Ultra SCSI-2, DS-RZ1DB-VW
Drive Reconstruct Disk hot swap Disk hot spare Redundant power supplies Redundant controllers Redundant fans Mixed drive types Mixed RAID levels within Drive Group Configurable reconstruct time Stripe size Write through cache Write back cache Battery Backup for Cache Boot capability Number of controllers/system
Automatic Yes Yes Yes No Yes Yes Yes Yes Variable, 8 K-64 KB Yes, User Selectable (default) Yes, User Selectable (optional) Yes Bootable from RAID set (System dependent) 4 RAID controllers in any combination of KZESC or KZPSC with OpenVMS, DIGITAL UNIX, Windows NT, or Novell NetWare are subject to specific CPU configuration limitations 4-32 MB; 4 MB standard
Cache support
Storage
7.56
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks KZPAC RAID Array 230/Plus Storage Controller DIGITAL StorageWorks RAID Array 230/Plus Controller is a member of the PCI-based SCSI RAID Controller family. Available in one- and three-channel versions, it offers all features of the StorageWorks RAID Array 230, but with increased performance. It supports both Ultra SCSI and Fast-Wide SCSI storage enclosures and subsystems. DIGITAL StorageWorks RAID Array 230/Plus Controller can coexist with StorageWorks RAID Array 210 and 230 controllers in the same server. The product includes hardware controller, RAID Configuration Utility (RCU), graphical user interface (GUI) for managing and monitoring the controller, and documentation. The RCU and online GUI utilities, included with RAID Array 230/Plus, support the entire DIGITAL RAID Array 200 family of products. In additional, an optional battery backup module (KZPSC-UB) retains the contents of the cache for approximately 8 to 12 hours, depending on size of cache. RAID Array 230/Plus Controller offers a wide, 16-bit support environment. DIGITAL recommends Ultra BA356 storage shelves be used with the -VW variants of the disk drives for highest performance. The KZPAC is still fully compatible with existing subsystems based on non-Ultra BA356 storage shelves. 4 MB and 8 MB cache options are available on the RAID Array 230/Plus; cache options are not interchangeable with other members of the RAID Array 200 family. The performance of DIGITAL StorageWorks RAID Array 230/Plus Controller (KZPAC), compared to the RAID Array 230 Controller (KZPSC), shows an approximate increase of 25 percent in I/O per second throughput, and approximately a 30 percent increased in bandwidth. Exact performance is greatly dependent on a large number of parameters, including RAID level; RAID subsystem specific attributes (type and size of cache); number of RAID controllers on the system; number and type of disks used; application parameters (read/write ratio, file size, and block size); type of system; overall system activity; and operating system. The default settings in the configuration utility are set to optimize performance for most applications. DIGITAL StorageWorks RAID Array 230/Plus Controller comes with 3-year warranty: first year on-site; second and third year, return to dealer (RTD). Features
Supports Ultra SCSI storage subsystems High-performance RAID controller for AlphaServer systems Ultra SCSI support for new and existing KZPAC controllers can be enabled by simply using the RAID Configuration Utility (RCU) Backplane compatible to existing Fast-Wide SCSI enclosures and devices Replacement for RAID Array 230, PCI-based SCSI RAID controller
Provides RAID Levels 0 (striping), 1 (mirroring), 0+1 (striped mirroring), and 5 (striping with parity) Supports up to 21 disk drives per controller; up to 8 logical drives MS100-BB cache memory allows customers to upgrade an existing KZPAC-CA to a KZPAC-CB at minimal cost and to obtain the highest performance possible from a KZPAC backplane RAID controller
Ordering Information DIGITAL StorageWorks RAID Array 230/Plus Controller (KZPAC) subsystem is available in three models. It can be configured with disk drives inside system enclosure or in standalone StorageWorks pedestal enclosures. DIGITAL StorageWorks RAID Array 230/Plus Controller Note: SCSI cables must be ordered separately KZPAC-AA
KZPAC-CA
One port Ultra SCSI (Ultra SCSI Wide Single-Ended) PCI-based RAID Controller with 4 MB of cache memory, 68-pin HD connector on module for internal connection; 0.8 mm, 68 pin connector on module's standard PCI bulkhead for external connection; StorageWorks RAID Array 230/Plus Subsystem Software; StorageWorks RAID Array 200 Management Utility. Media; licenses, and documentation. Requires SCSI cable. Three port Ultra SCSI (Ultra SCSI Wide Single-Ended) PCI-based RAID Controller with 4 MB of cache memory, 68-pin HD connectors on module for internal connection; two ports are available through 0.8 mm 68 pin connectors on module's standard PCI bulkhead for external connection (third port can be connected to a 0.8 mm 68-pin connector on a standard PCI bulkhead connector via an adapter cable); StorageWorks RAID Array 230/Plus Subsystem Software; StorageWorks RAID Array. 200 Management Utility Media; licenses, and documentation. Requires SCSI cables.
Storage
7.57
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks KZPAC RAID Array 230/Plus Storage Controller (continued) DIGITAL StorageWorks RAID Array 230/Plus Controller Note: SCSI cables must be ordered separately KZPAC-CB
KZPSC-UB KZPAC-SB
Three port Ultra SCSI (Ultra SCSI Wide Single-Ended) PCI-based RAID Controller with 8 MB of cache memory, 68-pin HD connectors on he module for internal connection; two ports available through 0.8 mm 68 pin connectors on module's standard PCI bulkhead for external connection (third port can be connected to a 0.8 mm 68-pin connector on a standard PCI bulkhead connector via an adapter cable); StorageWorks RAID Array 230/Plus Subsystem Software; StorageWorks RAID Array 200 Management Utility Media; licenses, and documentation. Requires SCSI cables. Battery module for all KZPAC cache memory Dual bulkhead assembly for connecting two third channels from KZPAC and/or KZPSC to one bulkhead slot.
SCSI cables and Cache Options BN31L-1E BN31M-1E BN31S-1E BN31S-02 BN31K-0E BN37A-xx MS100-BB
8-bit narrow SCSI cable (1.5 meter) for KZPSC/KZPAC 16-bit wide SCSI cable (1.5 meter) for KZPSC/KZPAC 16-bit wide SCSI right angle cable (1.5 meter) for KZPSC/KZPAC to BA356 StorageWorks enclosure 16-bit wide SCSI right-angle cable (2.0 meter) for KZPSC/KZPAC to BA356 StorageWorks enclosure. Note: BN31S-1E 1.5 meter cable should be used if possible. 16-bit wide SCSI internal cable with bulkhead (0.5 meter) for KZPSC/KZPAC third port external connections General Ultra SCSI cable for connecting the KZPAC to BA356 storage shelves (xx designates required length) 8 MB EDRAM cache memory SIMM which upgrades KZPAC-CA to KZPAC-CB. (Note: The MS100-BB is not supported on the one-channel KZPAC-AA; also MS100-AA and MS100-AB, expanded cache modules for the KZPSC, are not applicable to KZPAC.)
Hardware Support Firmware Revision required V2.42 Note: All servers except AlphaServer 800 require external drives for Ultra SCSI support; see system configuration menus for requirements AlphaServer 800 AlphaServer 2100A AlphaServer 1000 series AlphaServer 4000/4100 series AlphaServer 2000 series AlphaServer 8200/8400 series Software Support Note: See system configuration menus for requirements DIGITAL UNIX V3.2G and V4.0B or later Windows NT 3.51 with Service Pack 4, 4.0 or later OpenVMS V6.2-1H3 or later, V7.1 or later
DIGITAL UNIX V4.0G, Windows NT 4.0, and OpenVMS V7.1 required for AlphaServer 800, AlphaServer 1000A 5/333, 5/400, and 5/500 systems
CD-ROM and Tape Support
CD-ROM or tape support is not available for DIGITAL UNIX or OpenVMS Windows NT pass-through capabilities are provided for the following: - CD-ROM drives RRD43-VA, RRD44-VA, RRD45-VA, and RRD46-VA - Tape drives TKZ10-VA, TKZ11-VA, TLZ06-VA, TLZ07-VA, TLZ09-VA, TZ86-VA, TZ87-VA, TZ88-VA, and TZ89-VW
Storage
7.58
DIGITAL Storage RAID Controllers
DIGITAL StorageWorks KZPAC RAID Array 230/Plus Storage Controller (continued) Disk Drives Supported
RZ26N-VA/VW, 1.05 GB RZ28D-VA/VW, 2.1 GB RZ28M-VA/VW, 2.1 GB RZ29B-VA/VW, 4.3 GB DS-RZ28L-VA, 2.1GB, 7200 RPM SCSI
DS-RZ29L-VA, 4.3GB, 7200 RPM SCSI DS-RZ40-VA, 9.1GB, 7200 RPM SCSI DS-RZ1BB-VW, 2.1GB, Ultra SCSI DS-RZ1CB-VW, 4.3GB, Ultra SCSI DS-RZIDB-VW, 9.1GB, Ultra SCSI
Chart shows number of drives supported per KZPAC controller RAID Level
Physical Drive per logical drive
Usable Storage
Data Redundancy
0 1 0+1 5 JBOD
2 to 8 2 3-8 3-8 1
100 50 percent 50 percent 66-87 percent All
No Yes Yes Yes No
Maximum # of drives per Maximum # of drives per KZPAC-AA KZPAC-CA/CB
7 6 7 7 7
21 16 21 21 8
Specifications System bus interface Supported RAID levels SCSI channels Non-RAID device support Non-disk device support Drive reconstruction Disk hot swap Disk hot spare Redundant power supplies Redundant controllers Redundant fans Mixed drive types Mixed RAID levels within drive Configurable reconstruct time Stripe size Write-through cache Write-back cache Battery backup for cache Boot capability Number of controllers per system Cache support Enclosure support
Industry-standard PCI 2.1-compliant 0, 1, 0+1, 5, JBOD (“Just a Bunch of Disks”) SCSI-2, 16-bit Fast, Wide Single-ended, (20 MB per second) supports 8-bit and 16-bit drives Yes, disk drives (JBOD) Yes, CD-ROM and tapes supported on Windows NT only -- RRD43, RRD44, RRD45, RRD46, TLZ06, TLZ07, TLZ09, TZ86, TZ87, TZ88, TZ89 Automatic Yes Yes Yes No Yes Yes Yes, group Yes Variable 8 to 64 KB Yes, user-selectable (default) Yes, user-selectable (optional) Yes Bootable from RAID set (system dependent) 4 RAID controllers per system in any combination of RAID Array 210, 230, or 230/Plus; subject to minimal operating system levels and system specific configuration guidelines 4 MB on KZPAC-AA, 4 MB on KZPAC-CA, 8 MB on KZPAC-CB Ultra SCSI Enclosures: Seven device Pedestal—DS-BA356-KF, DS-BA356-KG Ultra SCSI Storage Shelves -- DS-BA356-SD/SE, DS-BA356-RC/RD, DS-BA356-JD/JE Fast-Wide SCSI enclosures: Seven device pedestal -- BA356-KC, BA356-KD Storage shelves -- BA356-JC, BA356-SB, BA356-SC
Storage
7.59
DIGITAL Storage RAID Controllers
DIGITAL RAID Array Controller Support Matrix Operating Systems
DIGITAL UNIX V3.2c or higher Open VMS ALPHA V6.1 or higher Open VMS VAX V5.5-2 or higher Windows NT Alpha Server 3.51 or higher Windows NT Intel Server V3.51 or higher Sun Solaris V 2.4 or higher HP-UX V10.0 or higher IBM AIX V4.1.4 or higher Novell NetWare V4.1 Adapters DEC 4000 embedded SHAC-based embedded EDA670 KFDDA/B KFPSA KFMSA KFMSB KFESA KFESB KFTIA KFQSA CIXCD-AB/AC CIBCA-BX CIPCA CI780 KZMSA KZPAA KZPSA KZTSA PMAZC SWXA3-BC SWIA3-BB SWSAP-BC SWHAP-BC SWXA3-BC
Storage
7.60
HSD10
HSD30
HSD50
HSJ30
HSJ50
X X
X X
X X
X X
X X
HSZ50
X X X X X X X X
X X
X X
X X X X
X X X X X
X X X X X
X X X X X X
X X X X X X X X X X X X
DIGITAL Storage RAID Controllers
DIGITAL RAID Array Controller Support Matrix (continued) 8-bit Narrow SCSI Devices
HSD10
HSD30
EZ64-VA EZ69-VA RZ25 RZ26 RZ26L RZ26N RZ28 RZ28B RZ28D RZ28M RZ29B RZ40 RZ73 RZ74 EZ51/54/58R RRD42/43/44/45/46 TLZ06/TLZ6L TLZ09/TLZ9L TLZ07/TLZ7L TZ86/87/87N TZ885/887 TZ867/77/75 TZ87 TZ88 TL820/810/812/822/826 TKZ60/61/62/63/64 TSZ07 RW524/525/530/531/532 RWZ52/53 RW546/551/552/555/557 SWXD3-SF SWXD3-SG SWXD3-SH SWXD3-SE
X X
X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X
HSD50
HSJ30
HSJ50
HSZ50
X X X X X X X X X X
X X X X X X X X X X X X
X X X X X X X X X X X X
X X X X X X X X X X X X
X X X X X X X X X
X X X X X X X X X
X X X X X X X X X
X X X
X X X X X X X X X X X
X X X X X X X
X X X X X X X X X X
X X X X X
X X X X
Storage
7.61
DIGITAL Storage RAID Controllers
DIGITAL RAID Array Controller Support Matrix (continued) 16-bit Wide SCSI Devices
DS-RZ1BB-VW DS-RZ1CB-VW DS-RZ1DB-VW DS-RZ26N-VZ DS-RZ28M-VZ DS-RZ40-VA EZ31-VW EZ32-VW EZ64-VW EZ69-VW RZ28-VW RZ28D-VW RZ29B-VW RZ26L-VW RZ26N-VW RZ28M-VW SWXD3-WF SWXD3-WG SWXD3-WH SWXD3-WE TZ89 TLZ893/TLZ894/TLZ896
Storage
7.62
HSD10
HSD30
HSD50
HSJ30
HSJ50
HSZ50
X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X X
X X X
X X X X X X X X X X
X X X X X X X X X X
X X X X X X X X X X X
X X X X X X X X X X
X X
X X
X X X
X X X X X X X X X X X