Transcript
ODSL 8
Optical laser distance sensors
Art. Nr. 501 09345
Dimensioned drawing
25 … 45mm 18 - 30 V DC
z Reflection-independent distance information z Highly insensitive to extraneous light z Analogue current and voltage output z Measurement range and mode adjustable z Teachable switching output z M12 turning connector
A B C D E F
Receiver Transmitter Optical axis 90° turning connector LED yellow, green Reference edge for the measurement (cover glass)
We reserve the right to make changes • ods_21gb.fm
Electrical connection
IEC 60947...
IEC 60947...
IP 69K IP 67
Accessories: (available separately)
z z z z z
Mounting systems Configuration adaptor UPG 5 Configuration software Cable with M12 connector (K-D …) Control guard
Leuze electronic GmbH + Co. KG
[email protected] • www.leuze.com
In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
ODSL 8/V4-45-S12 - 05
ODSL 8 Specifications
Tables
Optical data
Measurement range 1) Resolution Light source Wavelength Light spot Laser warning notice
25 … 45mm 0.01mm laser 650nm (visible red light) divergent, 1x6mm2 at 45mm see remarks
Error limits (relative to measurement distance) Absolute measurement accuracy 1) Repeatability 2) b/w detection thresh. (6 … 90% rem.)
0.5% 0.1% ≤ 0.5%
Timing Measurement time Response time Delay before start-up
2 … 5ms ≤ 150ms ≤ 300ms
Electrical data Operating voltage UB Residual ripple Open-circuit current Switching output Signal voltage high/low Analogue output
Indicators Green LED continuous light flashing off Yellow LED continuous light flashing off
18 … 30VDC (incl. residual ripple) ≤ 15% of UB ≤ 50mA PNP transistor, high-active ≥ (UB -2 V)/≤ 2V voltage 1 … 10V, RL ≥ 2kΩ current 4 … 20mA, RL ≤ 500Ω
teach-in on GND
Diagrams
teach-in on +UB
ready fault teaching procedure no voltage object inside teach-in measurement distance teaching procedure object outside teach-in measurement distance
Mechanical data Housing Optics cover Weight Connection type
metal glass 70g M12 connector, 8-pin, turning
Environmental data Ambient temp. (operation/storage) Protective circuit 3) VDE safety class 4) Protection class 5) Laser class Standards applied 1) 2) 3) 4) 5) 6)
-20°C … +50°C/-40°C … +70°C 2, 3 II, all-insulated IP 67, IP 69K 6) 2 (acc. to EN 60825-1) IEC 60947-5-2
Remarks
Luminosity coefficient 6% … 90%, over the entire temperature range, measurement object ≥ 50x50mm² Same object, identical environmental conditions, measurement object ≥ 50x50mm² 2=polarity reversal protection, 3=short-circuit protection for all outputs Rating voltage 250VAC In stop position of the turning connector (turning connector locked) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test
A B C D E F
Area not defined Linearity not defined Measurement range Object present No object detected Measurement distance
z Measurement time depends on the reflectivity of the measurement object and on the measurement mode. z Teaching procedure: Position measured object at desired measurement distance. Connect teach input to +UB for ≥ 2s. Reconnect teach input to GND, switching output is programmed. z The voltage output of the analogue version is calibrated before delivery. z Approved purpose: The ODSL 8 laser distance sensors are optical electronic sensors for the optical, contactless measurement of distance to objects.
Order guide Designation With M12 connector
ODSL 8/V4-45-S12
501 01883
Configuration adaptor
UPG 5
500 39627
ODSL 8/V4-45-S12 - 05
0803