Preview only show first 10 pages with watermark. For full document please download

Dimensions Specifications Characteristics

   EMBED


Share

Transcript

Specifications Nominal Voltage (V) Nominal Capacity (AH) Length Width Dimensions Height Total Height Approx. Weight Standard Terminals Case Material 96 mm 25 mm 62 mm 62 mm 0.36 kgs 12 0.8 3.78 inch 0.98 inch 2.44 inch 2.44 inch 0.79 lbs LV 0.8-12 VRLA (valve-regulated lead acid) battery is designed for general purpose application with 5 years standby life at 25°C. This battery is rechargeable, highly-efficient, leak-proof and maintenance-free. LivEn is ISO9001 and UL certified for quality assurance. ABS UL 94-HB Characteristics 20 hour rate 0.04 A 0.80 Ah 10 hour rate 0.07 A 0.74 Ah Capacity 5 hour rate 0.13 A 0.64 Ah 1 hour rate 0.54 A 0.54 Ah 15 Min Rate 1.48 A 0.37 Ah Internal Resistance 250 mΩ Max. Discharge Current ( 5 sec ) 8A Constant Max. Charge Current 0.24 A Voltage Standby Use 2.25 - 2.30 V /Cell Charge Cycle Use 2.40 - 2.50 V /Cell Method Discharge: -15 ~ 50 °C ( 5 ~ 122 °F) Operating Charge: -15 ~ 40 °C ( 5 ~ 104 °F) Temperature Range Storage: -15 ~ 40 °C ( 5 ~ 104 °F) For standby use: -3.3mV / °C /Cell Temperature coefficient For cycle use: -5.0mV / °C /Cell After 3-month 91% Self discharge After 6-month 82% 25℃ (77℉) After 12-month 64% °C °F) 40 (104 102% Temperature 25 °C (77 °F) 100% dependency of 0 °C (32 °F) 85% Capacity -15 °C (5 °F) 65% 140 0.20 2.60 120 0.17 2.40 100 0.14 2.20 80 0.11 2.00 60 0.08 1.80 40 0.05 1.60 20 0.02 1.40 )Ratio 2.275V/Cell Discharge Voltage vs Discharge Current Final Voltage V/Cell Discharge Current (A) 1.75 0.2C>(A) 1.70 1.30 1.60 0.2C<(A)<0.5C 0.5C<(A)<1.0C (A)>1.0C 25 (0.98) 62 (2.44) 96 (3.70) 4 8 12 16 20 24 Constant Current Discharge Characteristics Unit:A (25 ,77 ) VpcEnd 1.60 1.65 1.70 1.75 1.80 1.85 Dimensions 47 (1.85) 0 5MIN 3.16 3.05 2.88 2.60 2.32 2.04 10MIN 2.11 2.03 1.96 1.84 1.71 1.58 15MIN 1.62 1.57 1.53 1.45 1.37 1.29 20MIN 1.18 1.14 1.10 1.04 0.98 0.93 30MIN 0.93 0.92 0.91 0.89 0.79 0.85 60MIN 0.55 0.55 0.54 0.54 0.53 0.53 2HR 0.28 0.28 0.27 0.26 0.26 0.25 3HR 0.21 0.21 0.20 0.20 0.19 0.18 4HR 0.17 0.17 0.16 0.15 0.15 0.15 5HR 0.14 0.14 0.14 0.14 0.13 0.12 6HR 10HR 20HR 0.09 0.08 0.04 0.09 0.08 0.04 0.09 0.08 0.04 0.09 0.08 0.04 0.09 0.07 0.04 0.09 0.07 0.04 Constant Power Discharge Characteristics Unit:W (25 ,77 ) VpcEnd 1.60 1.65 1.70 1.75 1.80 1.85 5MIN 34.0 33.0 32.0 30.9 27.1 26.2 10MIN 22.4 22.4 21.8 20.8 19.5 18.1 15MIN 18.2 17.9 17.5 16.6 15.7 14.8 20MIN 13.1 12.9 12.6 12.2 11.9 11.6 30MIN 11.20 11.08 11.00 10.74 10.48 10.23 60MIN 6.65 6.63 6.62 6.51 6.40 6.29 2HR 3.46 3.44 3.43 3.38 3.33 3.28 3HR 2.45 2.44 2.44 2.42 2.40 2.39 4HR 2.00 2.00 2.00 1.98 1.97 1.95 5HR 1.96 1.95 1.94 1.93 1.92 1.91 6HR 10HR 20HR 1.07 0.94 0.52 1.06 0.93 0.50 1.05 0.92 0.49 1.04 0.91 0.48 1.00 0.90 0.46 0.97 0.88 0.45 www.liven-battery.com 201104