Specifications Nominal Voltage (V) Nominal Capacity (AH) Length Width Dimensions Height Total Height Approx. Weight Standard Terminals Case Material 2 1000 474 mm 18.66 inch 173 mm 6.81 inch 329 mm 12.95 inch 366 mm 14.41 inch 65 kgs 140.99 lbs V10 ABS UL 94-V0 LVT1000-2 VRLA (valve-regulated lead acid) battery is designed for telecom application with 20 years standby life at 25°C. This battery is rechargeable, highly-efficient, leak-proof and maintenance-free. LivEn is ISO9001 and UL certified for quality assurance. Characteristics 20 hour rate 53.0 A 1060 Ah 10 hour rate 100.0 A 1000 Ah Capacity 5 hour rate 186.0 A 930 Ah 1 hour rate 625.0 A 625 Ah 15 Min Rate 1320.0 A 330 Ah Internal Resistance 0.74 mΩ Max. Discharge Current ( 5 sec ) 6000 A Constant Max. Charge Current 300 A Voltage Standby Use 2.23 V /Cell Charge Cycle Use 2.25 V /Cell Method °C ( 5 ~ 122 °F) Discharge: -15 ~ 50 Operating Charge: -15 ~ 40 °C ( 5 ~ 104 °F) Temperature Range Storage: -15 ~ 40 °C ( 5 ~ 104 °F) For standby use: -3.3mV / °C /Cell Temperature coefficient For cycle use: -5.0mV / °C /Cell After 3-month 91% Self discharge After 6-month 82% 25℃ (77℉) After 12-month 64% 40 °C (104 °F) 102% Temperature 25 °C (77 °F) 100% dependency of °C °F) 0 (32 85% Capacity -15 °C (5 °F) 65% 0.1CA 1CA 2CA 0.63CA (Min-Hrs) Discharge Voltage vs Discharge Current Final Discharge Voltage (V/Cell) 1.90 1.80 1.75 1.70 1.60 Discharge Current (A) 0.05C > (A) 0.15C > (A) ≧ 0.05C 0.20C > (A) ≧ 0.15C 0.40 C > (A) ≧ 0.20C (A) > 0.40C Dimensions 474 (18.66) 329 (12.95) 366 (14.41) 173 (6.81) e Characteristics Unit:A (25 ,77 ) Constant Current Discharge Characteristics Unit:A (25 ,77 ) VpcEnd 1.60 1.67 1.70 1.75 1.80 1.83 15MIN 1426 1300 1206 1050 916 796 30MIN 980 936 910 840 736 650 60MIN 650 620 610 560 530 488 2HR 382 370 362 342 330 310 3HR 288 272 270 252 242 232 4HR 228 220 218 206 198 188 5HR 193 185 183 173 168 160 6HR 168 160 158 150 148 140 8HR 10HR 12HR 133 113 92.6 130 110 92.0 128 108 90.6 123 103 89.0 120 100 87.0 114 97.6 85.6 20HR 57.8 57.5 56.9 56.1 54.9 54.0 24HR 48.8 48.6 48.2 47.6 46.6 45.8 20HR 122 120 116 114 112 110 24HR 105 104 99.6 98.0 96.6 94.6 e Characteristics Unit:W (25 ,77 ) Constant Power Discharge Characteristics Unit:W (25 ,77 ) �20 M8 VpcEnd 1.60 1.67 1.70 1.75 1.80 1.83 15MIN 2330 2136 2036 1840 1680 1430 30MIN 1720 1650 1596 1490 1336 1156 60MIN 1156 1150 1116 1040 980 906 2HR 696 690 676 646 620 580 3HR 520 516 506 482 462 442 4HR 418 413 410 393 378 360 5HR 353 350 348 333 323 308 6HR 310 308 303 290 283 270 8HR 10HR 12HR 250 210 188 248 208 184 243 205 178 238 200 175 230 198 171 220 190 168 www.liven-battery.com 201103