Transcript
Dimmer Compatibility Report
IPL06
6674
DSL06-1LZ
DSM10-1LZ
IPE04-1LZ
DVCL-153P
CTCL-153P
DVCL-253P
AYCL-253P
DVELV-300P
SELV-300P
NTELV-600
Lutron
Leviton 6615
64156
LED/CL8/12W/30K/FM/RND/STD
64157
LED/CL8/12W/40K/FM/RND/STD
65598
LED/CL11/15W/27K/FM/RND/STD
63298
LED/CL11/15W/30K/FM/RND/STD
63299
LED/CL11/15W/40K/FM/RND/STD
63300
LED/CL11/15W/30K/FM/SQR/STD
63301
LED/CL11/15W/40K/FM/SQR/STD
65599
LED/CL14/25W/27K/FM/RND/STD
63302
LED/CL14/25W/30K/FM/RND/STD
63303
LED/CL14/25W/40K/FM/RND/STD
63304
LED/CL14/25W/30K/FM/SQR/STD
63305
LED/CL14/25W/40K/FM/SQR/STD
65665
LED/CL16/26W/30K/FM/RND/STD
65666
LED/CL16/26W/40K/FM/RND/STD
65667
LED/CL18/32W/30K/FM/RND/STD
65668
LED/CL18/32W/40K/FM/RND/STD
65661
LED/CL20/37W/30K/FM/RND/STD
65662
LED/CL20/37W/40K/FM/RND/STD
65663
LED/CL22/40W/30K/FM/RND/STD
65664
LED/CL22/40W/40K/FM/RND/STD
AAL06
LED/CL6/10W/40K/FM/RND/STD
DAL06P
LED/CL6/10W/30K/FM/RND/STD
64155
9531AW
64154
HCL453P
SLC03P
Legrand
Cooper
LED Indoor Luminaires
Traditional Ceiling Luminaires
*NOTE: The above table shows dimmers that have been tested and have demonstrated proper operation under normal conditions. Each installation being unique, various factors such as load, common neutrals or other electrical products on the circuit can, in certain instances, cause variance in system performance. Read and comply to the dimmer installation instructions. Consult dimming system manufacturer for additional support in operation. Standard recommends to use dimmers designed to work with LED lamps. Older dimmers designed for incandescent lamps may cause erratic operation. Do not mix lamps of different wattages or types on the same dimming circuit. Some dimmers may require more than one lamp for stable operation. The maximum number of lamps is determined by the dimmer wattage rating with LEDs. Be careful, these dimmers have different ratings depending on the lamp type. Again, refer to the dimmer installation instructions. For example, if the dimmer rating is 150W with LED, a user may use up to fifteen (15) 10W PAR30. Specifications are subject to change without notice. August 7, 2017
Dimmer Compatibility Report
PD-6WCL
DVCL-153P
DVELV-300P
SELV-300P
NTELV-600
AYCL-253P
IPE04-1LZ
DVCL-253P
DSM10-1LZ
CTCL-153P
DSL06-1LZ
IPL06
6615
HCL453P
SLC03P
6674
Lutron
Leviton
Legrand
Cooper AAL06
DAL06P
LED Indoor Luminaires
Edge-Lit LED Ceiling Luminaires 65454 65455 65456 65457 65458 65459 65460 65461 65462 65463 65464 65465
LED/CL6/EDGELIT/11W/30K/FM/RND/WH/STD LED/CL6/EDGELIT/11W/40K/FM/RND/WH/STD LED/CL8/EDGELIT/14W/30K/FM/RND/WH/STD LED/CL8/EDGELIT/14W/40K/FM/RND/WH/STD LED/CL12/EDGELIT/22W/30K/FM/RND/WH/STD LED/CL12/EDGELIT/22W/40K/FM/RND/WH/STD LED/CL6/EDGELIT/11W/30K/FM/SQR/WH/STD LED/CL6/EDGELIT/11W/40K/FM/SQR/WH/STD LED/CL8/EDGELIT/14W/30K/FM/SQR/WH/STD LED/CL8/EDGELIT/14W/40K/FM/SQR/WH/STD LED/CL12/EDGELIT/22W/30K/FM/SQR/WH/STD LED/CL12/EDGELIT/22W/40K/FM/SQR/WH/STD
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
*NOTE: The above table shows dimmers that have been tested and have demonstrated proper operation under normal conditions. Each installation being unique, various factors such as load, common neutrals or other electrical products on the circuit can, in certain instances, cause variance in system performance. Read and comply to the dimmer installation instructions. Consult dimming system manufacturer for additional support in operation. Standard recommends to use dimmers designed to work with LED lamps. Older dimmers designed for incandescent lamps may cause erratic operation. Do not mix lamps of different wattages or types on the same dimming circuit. Some dimmers may require more than one lamp for stable operation. The maximum number of lamps is determined by the dimmer wattage rating with LEDs. Be careful, these dimmers have different ratings depending on the lamp type. Again, refer to the dimmer installation instructions. For example, if the dimmer rating is 150W with LED, a user may use up to fifteen (15) 10W PAR30. Specifications are subject to change without notice. August 7, 2017
DSM10-1LZ
IPE04-1LZ
DVCL-153P
CTCL-153P
DVCL-253P
DVELV-300P
SELV-300P
NTELV-600
65607
LED/CLDR/BN/14/25W/30K/FM/RND/STD
65608
LED/CLDR/BN/14/25W/40K/FM/RND/STD
65611
LED/CLDR/BN/16/26W/30K/FM/RND/STD
65612
LED/CLDR/BN/16/26W/40K/FM/RND/STD
AYCL-253P
DSL06-1LZ
6674
IPL06
6615
AAL06
LED/CLDR/BN/12/20W/40K/FM/RND/STD
DAL06P
LED/CLDR/BN/12/20W/30K/FM/RND/STD
65606
9531AW
65605
HCL453P
SLC03P
Lutron
Leviton
LED Indoor Luminaires
Cooper
Legrand
Dimmer Compatibility Report
NTFTV
Lutron
IPL710-DL
TGCL-153PH-WH
S2-L
Leviton
Lutron 600PR-WH
MACL-153MR-WH
LGCL-153P
6683
6674
IPL06
Leviton
Double-Ring Ceiling Luminaires
65515
LHBE/S2/110W/2FT/40K/2/DD1/FP/STD
65516
LHBE/S2/162W/2FT/40K/2/DD1/FP/STD
65517
LHBE/S2/223W/4FT/40K/2/DD1/FP/STD
65518
LHBE/S2/162W/2FT/50K/2/DD1/FP/STD
65519
LHBE/S2/223W/4FT/50K/2/DD1/FP/STD
65559
LHBE/S2/320W/4FT/50K/2/DD1/FP/STD
65560
LHBE/S2/320W/4FT/50K/3/DD1/FP/STD
65561
LHBE/S2/162W/2FT/40K/3/DD1/FP/STD
65562
LHBE/S2/223W/4FT/40K/3/DD1/FP/STD
LED ECONO HIGHBAY 4.0
Brushed Nickel Ceiling Luminaires 64247
LED/CLBN5.75/10W/30K/FM/RND/STD
64248
LED/CLBN5.75/10W/40K/FM/RND/STD
64249
LED/CLBN7.75/12W/30K/FM/RND/STD
64250
LED/CLBN7.75/12W/40K/FM/RND/STD
64095
LED/CLBN11/15W/30K/FM/RND/STD
64096
LED/CLBN11/15W/40K/FM/RND/STD
64099
LED/CLBN14/25W/30K/FM/RND/STD
64100
LED/CLBN14/25W/40K/FM/RND/STD
*NOTE: The above table shows dimmers that have been tested and have demonstrated proper operation under normal conditions. Each installation being unique, various factors such as load, common neutrals or other electrical products on the circuit can, in certain instances, cause variance in system performance. Read and comply to the dimmer installation instructions. Consult dimming system manufacturer for additional support in operation. Standard recommends to use dimmers designed to work with LED lamps. Older dimmers designed for incandescent lamps may cause erratic operation. Do not mix lamps of different wattages or types on the same dimming circuit. Some dimmers may require more than one lamp for stable operation. The maximum number of lamps is determined by the dimmer wattage rating with LEDs. Be careful, these dimmers have different ratings depending on the lamp type. Again, refer to the dimmer installation instructions. For example, if the dimmer rating is 150W with LED, a user may use up to fifteen (15) 10W PAR30. Specifications are subject to change without notice. August 7, 2017
Philips
NTFTV
61989 Transceiver
DVSTV
MS-Z101
NTSTV
SR1200ZTUV
Lutron
NFTV
IP710-LFZ
STANDARD
Leviton
LED Indoor Luminaires
IPL710-DL
Lutron
Leviton
Dimmer Compatibility Report
64697
LPAN/1X4/120-347V-DIM/40W/35K/STD
64698
LPAN/1X4/120-347V-DIM/40W/40K/STD
64082
LRCB/1X4/120-277V-DIM/36W/35K/STD
64083
LRCB/1X4/120-277V-DIM/36W/40K/STD
64084
LRCB/1X4/120-277V-DIM/36W/50K/STD
64085
LRCB/2X2/120-277V-DIM/36W/35K/STD
64086
LRCB/2X2/120-277V-DIM/36W/40K/STD
64087
LRCB/2X2/120-277V-DIM/36W/50K/STD
64088
LRCB/2X4/120-277V-DIM/42W/35K/STD
64089
LRCB/2X4/120-277V-DIM/42W/40K/STD
64090
LRCB/2X4/120-277V-DIM/42W/50K/STD
64091
LRCB/2X4/120-277V-DIM/68W/35K/STD
64092
LRCB/2X4/120-277V-DIM/68W/40K/STD
64093
LRCB/2X4/120-277V-DIM/68W/50K/STD
LED Panels 64699 64700 64701 64702 64703 64704 64705 65542 65543 65544
LPAN/1X4/120-347V-DIM/40W/50K/STD LPAN/2X2/120-347V-DIM/40W/35K/STD LPAN/2X2/120-347V-DIM/40W/40K/STD LPAN/2X2/120-347V-DIM/40W/50K/STD LPAN/2X4/120-347V-DIM/50W/35K/STD LPAN/2X4/120-347V-DIM/50W/40K/STD LPAN/2X4/120-347V-DIM/50W/50K/STD LPAN/S2/2X2/120-347V-DIM/40W/35K/STD LPAN/S2/2X2/120-347V-DIM/40W/40K/STD LPAN/S2/2X2/120-347V-DIM/40W/50K/STD
65545
LPAN/S2/2X4/120-347V-DIM/50W/35K/STD
65546
LPAN/S2/2X4/120-347V-DIM/50W/40K/STD
65547
LPAN/S2/2X4/120-347V-DIM/50W/50K/STD
Center Basket Luminaires
Note: Compatible with most 0-10 V dimmers
*NOTE: The above table shows dimmers that have been tested and have demonstrated proper operation under normal conditions. Each installation being unique, various factors such as load, common neutrals or other electrical products on the circuit can, in certain instances, cause variance in system performance. Read and comply to the dimmer installation instructions. Consult dimming system manufacturer for additional support in operation. Standard recommends to use dimmers designed to work with LED lamps. Older dimmers designed for incandescent lamps may cause erratic operation. Do not mix lamps of different wattages or types on the same dimming circuit. Some dimmers may require more than one lamp for stable operation. The maximum number of lamps is determined by the dimmer wattage rating with LEDs. Be careful, these dimmers have different ratings depending on the lamp type. Again, refer to the dimmer installation instructions. For example, if the dimmer rating is 150W with LED, a user may use up to fifteen (15) 10W PAR30. Specifications are subject to change without notice. August 7, 2017