Dip switch settings of trackballs
Ver. 1.5
All NSI trackball series and all NSI keyboards with integrated trackball are using trackball modules which are labelled as : (f.i. P38-540420)
Pxx-xXxxxx Oxx-xXxxxx Lxx-xXxxxx Xxx-xXxxxx
X : denotes the output protocol 0 = Phase quadrature output 4 = “PS/2 only” output 5 = “USB only” output denotes ball diameter in mm 6 = “Combo PS/2 & USB” output A = “RS232 only” output
Current range (identified by the label XXX on the IC of the motherboard of the trackball, f.i. LC602A) COMBO protocol types (PS/2 & USB) Partnumber P50-x6xxxx , O50-x6xxxx , L50-x6xxxx and X50-x6xxxx Dip Switch Function OFF ON 1 Orientation 1 See Figure 1 2 Orientation 2 3 VX3 - Virtual 3 Axis Feature disabled Feature enabled 4 Smart feature Feature disabled Feature enabled 5 Tracking mode Ballistic tracking Linear tracking 6 N/A N/A N/A 7 N/A N/A N/A 8 N/A N/A N/A
Orientation table
Y+ X+
Orientation 2 ON
Orientation 2 OFF
Orientation 1 ON Orientation 1 OFF
X : Dip switch must be in this position
VX3™ VX3 is patent protected facility that provides the same 2 modes of functionality as a scroll wheel on a 3-axis mouse. Operation: Press middle button once to latch scroll mode one (e.g. dynamic pan feature); Press middle button again to latch scroll mode two (e.g. 3rd axis zoom feature); Further middle button presses toggles between scroll mode one and scroll mode two; Press either left or right buttons to cancel feature and resume normal X-Y cursor operation Smart Switch A patent protected button latch facility. Press right button for 3 seconds or more to enable; Once enabled, pressing any button for approximately 1 second latches that button on; Press any button momentarily to de-latch; Disabled with a further press of the right button for 3 seconds or more; Tracking Mode Ballistic Tracking: Intuitive tracking algorithm to provide increased cursor resolution when tracking fast whilst retaining the original resolution for tracking accurately at slow speeds. Linear Tracking: No tracking algorithm. 620 counts per ball revolution maintained at all tracking speeds.
NSI bvba, Haakstraat 1A, B-3740 Bilzen, Belgium Tel. : ++32 (0) 89 51 90 00 Website : www.nsi-be.com Fax : ++32 (0) 89 51 90 09 E-mail :
[email protected] The company reserves the right to alter without prior knowledge the specification or design of any standard product or service.
www.nsi-be.com/support.htm
1/2
Dip switch settings of trackballs
Ver. 1.5
Former range (identified by the label XXXXX on the IC of the motherboard of the trackball, f.i. 199) COMBO protocol types (PS/2 & USB) Partnumber P50-x6xxxx, P75-x6xxxx, P25-x6xxxx and O50-x6xxxx Dip Switch Function 1 Orientation 1 2 Orientation 2 3 VX3 - Virtual 3 Axis 4 Smart feature Double track.(P75) 5 Y inverted 6 7 8 -
OFF
Orientation table
ON
See orientation table Feature enabled Feature enabled Feature enabled Feature disabled X X X
Feature disabled Feature disabled Feature disabled Feature enabled -
Y+ X+
Orientation 2 ON
Orientation 2 OFF
Orientation 1 ON Orientation 1 OFF
X : Dip switch must be in this position
USB protocol types
Partnumber P38-x5xxxx, P38-x6xxxx
Dip Switch Function OFF ON 1 Orientation 1 See orientation table 2 Orientation 2 3 VX3 - Virtual 3 Axis Feature enabled Feature disabled 4 Smart feature Feature enabled Feature disabled X : Dip switch must be in this position
PS/2 protocol types
Orientation table
Y+ X+
X : Dip switch must be in this position
Orientation 2 OFF
Orientation 1 ON Orientation 1 OFF
Partnumber P38-x4xxxx-5257
Dip Switch Function OFF ON 1 Orientation 1 See orientation table 2 3 VX3 - Virtual 3 Axis Feature enabled Feature disabled See orientation table 4 Orientation 2
Orientation 2 ON
Orientation table
Y+ X+
Orientation 2 ON
Orientation 2 OFF
Orientation 1 ON Orientation 1 OFF
SERIAL protocol types Partnumber P38-xAxxxx and P50-xAxxxx Dip Switch 1 2 3 4 5 6 7 8
Function OFF ON Protocol mode Microsoft RS232 Mouse systems Orientation 1 See orientation table Orientation 2 Tracking mode Ballistic Lineair Virtual 3 axis* Feature Disabled Feature enabled Baud rate selection* 1200 9600 Smart feature Feature Disabled Feature enabled X Output level Std. RS232 TTL
Orientation table
Y+ X+
Orientation 2 ON
Orientation 2 OFF
Orientation 1 ON Orientation 1 OFF
X : Dip switch must be in this position * Microsoft mode: VX3 Mouse system: Baud rate selection