Transcript
0330
Direct-acting 2/2- or 3/2-way pivoted armature valve
• Direct-acting, media-separated valve with diameter of up to DN 5 • Maintenance-free pivoted armature technology • Vibration-proof, block screwed coil system • Suitable for aggressive alkaline and acidic solutions • Service-friendly, robust manual operation • Explosion proof versions The 0330 valve is a direct-acting, media-separated pivoted armature valve. It is available in 3/2- and 2/2-way versions. As a 3/2-way version, it can be used as a distributor or mixing valve. Various diaphragm material combinations and methods of operation are available depending on the application. The standard brass housing satisfies all European drinking water requirements. Stainless steel (316), PVDF, and polypropylene housing versions complete the offering. The solenoid coils are moulded with a chemically resistant epoxy. The 0330 is equipped with manual override for commissioning and testing. For reduced energy requirements all coils can be delivered with electronic power reduction or as an impulse version. The switching status can be indicated with position feedback as a binary or NAMUR signal. In combination with a plug in accordance with DIN EN 17301-803 Form A, the valves satisfy protection class IP65/67 – in combination with a stainless steel or plastic housing NEMA 250 Cat. 4X.
Content: Standard version Technical data Additional options Dimensions & Pin Assignment Ordering chart
p. 1 p. 4 p. 5 p. 6
Explosion proof version Technical data Additional options Dimensions & Pin Assignment Ordering chart
p. 7 p. 9 p. 10 p. 11
Technical data Available housing materials
Port connection Seal material Medium for NBR
Brass Stainless steel (1.4401) PP (Polypropylene) PVDF (Polyvinylfluoride) G 1/4; NPT 1/4; (RC 1/4 and G 1/8 on request) EDPM / FKM / FFKM / NBR
Neutral medium such as compressed air, town gas, water, hydraulic oil, oils and fats without additives, oxygen EPDM Alkalis, acids to medium concentrations, alkaline washing and bleaching lyes for FKM Oxydizing acids and substances, hot oils with additives, salt solutions, waste gases, oxygen for FFKM aggressive mediums, hot air, hot oils All Materials - For more exact info. please refer to our chemical resistance chart Medium temperature NBR 0 to +80 °C for body material EPDM -30 to +90 °C brass or stainless steel FKM 0 to +90 °C FFKM +5 to +90 °C Medium temperature NBR 0 to +80 °C for body material EPDM -30 to +80 °C PP or PVDF FKM 0 to +80 °C FFKM +5 to +80 °C Viscosity Max. 37mm²/s Ambient temperature max. +55 °C Voltages 24V 50Hz; 110V 50Hz; 230V 50Hz; 120V 60Hz; 240V 60Hz; 12V DC; 24V DC; (further voltages on request) Voltage tolerance +/- 10% Duty cycle for brass and 100% stainless steel. Duty cycle for PP and PVDF 40% ED (60% intermittent operation) in 30min for 8W version 100% ED for 5W version
continued
www.burkert.com
p. 1/12
0330
Circuit function
2 (A)
A 2/2 way direct-acting solenoid valve, normally closed
1 (P)
Technical data (continued) Electrical connection
Pin terminal acc. to DIN EN 175301-803 Form A for cable pug Type 2508/2509 (also on request with moulded cable or terminal box) IP65 with Cable Plug H As required, preferably with actuator upright
2 (B)
B 2/2 way direct-acting solenoid valve, normally open
1 (P) 2(A)
C 3/2 way direct-acting solenoid valve, normally closed
12
D 3/2 way direct-acting solenoid valve, normally open
10
1(P)
3(R) 2(B)
1(P)
3(R) 2(A)
E 3/2 way mixing solenoid valve
F 3/2 way direct-acting, distribution solenoid valve
1(P1)
3(P2)
4(A)
2(B)
Protection class Coil insulation class Installation Weight [kg] with metal body with plastic hausing
0.47 0.40
Standard power consumption Frequency AC Inrush [VA] 30
Hold [VA] 15
Operation [W] 8
Frequency DC Cold [W] 11
Warm [W] 8
Impulse (inrush winding) Frequency AC Hold [VA] 20
Frequency DC Cold [W] 11
Operation [W] 11
Warm [W] 8
1(P)
T
3/2 way direct-acting solenoid valve, flow direction optional
Response times NC
NO
Orifice [mm] 2-4
Frequency AC Opening [ms] 8-15
Closing [ms] 8-15
Frequency DC Opening [ms] 10-20
Closing [ms] 10-20
Response times [ms]: Measured at valve outlet at 6 bar and +20 °C Opening: Pressure rise 0 to 90%, Closing: Pressure drop 100 to 10%
Pressure range and flow rate for metal body Circuit function
DN
Kv value water [m³/h]: DC
A/B/C/D/F
E
T
2.0 3.0 4.0 5.0 2.0 3.0 4.0 5.0 2.0 3.0 4.0 5.0
0.08 0.14 0.17 0.29 0.08 0.14 0.17 0.29 0.08 0.14 0.17 0.29
AC [50 or 60Hz] 0.11 0.18 0.23 0.29 0.11 0.18 0.23 0.29 0.11 0.18 0.23 0.29
Standard Pressure range [bar] 0 - 16 5) 0 - 10 0-5 0 - 2.5 0 - 10 0-6 0-3 0 - 1.5 0 - 12 0-8 0-4 0 - 2.5
4)
1)
Vacuum 3) Pressure range -0.98 - 10 -0.98 - 6 -0.98 - 3 -0.98 - 1 -0.98 - 8 -0.98 - 5 -0.98 - 2.5 -0.98 - 1 -0.98 - 8 -0.98 - 5 -0.98 - 2.5 -0.98 - 1
Impulse 4)
[bar]
2)
Pressure range [bar] 0 - 16 5) 0 - 10 0-5 0 - 2.5 0 - 10 0-6 0-3 0-1 0 - 10 0-6 0-5 -
4)
Pressure range and flow rate for plastic body Circuit function
A/B/C/D/F
E/T
DN Kv value water
2.0 3.0 4.0 5.0 2.0 3.0 4.0
[m3/h]6) 0.13 0.25 0.30 0.40 0.13 0.25 0.30
Standard 1) Pressure range 4) [bar] AC [50 or 60Hz] 0 - 16 5) 0 - 10 0-5 0 - 4.5 0 - 10 0-6 0-3
Pressure range [bar] DC 0 - 12 0-8 0-4 0-3 0-7 0-4 0-2
4)
Vacuum Pressure range -0.98 - 10 -0.98 - 6 -0.98 - 3 -0.98 - 1 -0.98 - 7 -0.98 - 5 -0.98 - 2.5
4)
Impulse 2) Pressure range [bar] [bar] 0 - 12 0-8 0-4 0-3 0-7 0-4 0-2
4)
1)
Rated power consumtion 8W Inrush power 11W Vacuum possible for all seal materials 4) Pressure values [bar] with respect to atmospheric pressure 5) For seal material FKM and FFKM the max. mediums pressure is 12 bar 6) At frequency DC the KV value is reduced till 10% to fulfil the function 2) 3)
p. 2/12
0330
Other circuit functions The valves are fitted with different springs for a specific circuit function. When used in other circuit functions the permissable operating pressure changes acc. to the following table. Metal body (8W respectively 11W) Circuit function
Max. operating pressure [bar] when using the valve in a new circuit function Orifice 2mm A1)
C D T
16 4 8
B1) 1.5 16 8
Orifice 3mm C 16 4.5 10
D 1.5 16 10
E 1.5 4 10
F 16 4 8
A 10 2.5 6
B 1 10 6
Orifice 4mm C 10 2.5 6
D 1 10 6
E 1 2 6
F 10 3 6
A 5 2 3
B 0.8 5 3
C 5 2 3
D 0.8 5 3
E 0.8 2 3
F 5 2 3
C 5 2 4
D 0.8 5 1
E 0.8 2 1
F 5 2 5
Plastic body (8W respectively 11W) Circuit function C D F 1)
Max. operating pressure [bar] when using the valve in a new circuit function Orifice 2mm A1) 16 4 16
B1) 1.5 16 1.5
Orifice 3mm C 16 4.5 10
D 1.5 16 1.5
E 1.5 4 1.5
F 16 4 16
A 10 2.5 6
B 1 10 1
Orifice 4mm C 10 2.5 6
D 1 10 1
E 1 2 1
F 10 3 10
A 5 2 4
B 0.8 5 1
For circuit function A and B the valve must be connected acc. to the pin assignment of 3/2-way valve.
Additional options
Coil
Epoxy
Diaphragm
EDPM, FKM, FFKM, NBR
O-Ring
EDPM, FKM, FFKM, NBR
Seat
Brass Stainless steel (1.4401) PP (Polypropylene) PVDF (Polyvinylfluoride)
Valve body
Brass Stainless steel (1.4401) PP (Polypropylene) PVDF (Polyvinylfluoride)
p. 3/12
0330 Ex
Additional options Option Impulse version
Variable Code CF02
Oxygen versions
NL02
Increased purity requirements e.g. oil, grease and silicone-free Increased tightness requirements Electrical feedback High-power electronics
NL50/NL05 PCxx LF02 / LF03 CZ05
Vacuum version Increased purity and tightness requirements Increased purity and tightness requirements and vacuum version Coil with reduced power (5W)
NA02 NA03 NA01
Cable plug
JFxx / JGxx
Approvals
PD01 PD02 PD24
PD45
PD07 possible conformities (depending on the assembly) Approvals
PE84
Description Bistable magnetic system with inrush and drop-off coil;Continuous operation or operation with short current pulses (min. 150 ms) possible Suitable for applications with oxygen (non-metal materials that are in contact with the medium, are tested and approved according to BAM) Wetted parts are specially cleaned and packaged in accordance with the valves Standard units are tested at 10-2 mbar x l / sec; feasible up to 106 mbar See Type 1060 Inrush power 60 W, nominal holding current 3 W; with plastic versions 100% ED is now feasible Suitable for vacuums up to -0.98bar Wetted parts are specially cleaned and leak tested to 10-4 mbar x l/sec Wetted parts are specially cleaned and leak tested up to 10-4 mbar x l/sec and suited for vacuum up to -0.98 bar Devices have lower pressure range; with plastic versions 100% ED is now feasible Cable plug is included in delivery. Cable plug versions (acc. to DIN EN 175301-803 Form A), see datasheet Type 2508 and 2509 CSA General Purpose valve CSA General Purpose valve UL recognized General Purpose valve UL listed Genaral Purpose valve CSA Genaral Purpose valve FM non-incendive for class I / II / III Div.2 T4 FM explosionproof for class I Div. 1 and dust-ingnitionproof for class II / III Div. 1 T4 CSA General Purpose valve for hazardous location class I / II Div. 2 and class III T4 DNV-GL (formerly Germanischer Lloyd) EAC, trinking water, FDA NSF61 - drinking water approval USA
p. 4/12
0330
Dimensions [mm]
Plastic body
104
53
82
Metal body
9
9
G1/4
G1/4
22 13
100
71
9
12 56
34 24
34 32 24
9
38 46
38 46
- For metal housings, the minimum thread length at the middle connection is 7.5mm - Mounting device: By drilling M4 x 8 (metal housing) or self-tapping screws (plastic housing) on underside of the housing on the hole pattern 38 x 24.
Port connections The connections marked with 1, 2 and 3 are labelled in the drawing according to the circuit function table.
2
1
3
1
Circuit function
Connection 1
Connection 2
A
P
A
Connection 3
B
B
P
C
P
A
R
D
R
B
P
E
P1
A
P2
F
A
P
B
T
NC
In/Out
NO
2
p. 5/12
0330
Ordering chart (products with reduced delivery time) All devices with connection thread G 1/4, manual override and cable plug Type 2508
FKM FKM FKM EPDM NBR
3.0
NBR
230/50
4.0 4.0 4.0 4.0 2.0
024/50
D
FKM FKM FKM FKM NBR EPDM FKM FKM FKM FKM NBR EPDM EPDM FKM FKM EPDM EPDM FKM FKM FKM FKM NBR NBR FKM NBR
024/DC
C
3.0 3.0 3.0 3.0 3.0 3.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 5.0 5.0 5.0 5.0 3.0 4.0 3.0 4.0 2.0 3.0 3.0 4.0
Housing or seat material
B 2)
Seal Material
A 2)
Orifice [mm]
Circuit function
Item no. per voltage/frequency [V/Hz]
Brass Stainless steel PP PVDF Brass PP Brass Stainless steel PP PVDF Brass PP PVDF PP PVDF PP PVDF Brass Brass Stainless steel Stainless steel Brass Brass Stainless steel
020 293 020 292 018 410 018 188 020 294 067 214 024 019 018 276 062 695 023 472 025 084 021 660 057 573 062 624 064 512 061 321 120 184 141 917 141 920 141 928 141 932 041 103 041 107 052 344 042 218
022 883 023 984 088 496 020 286 086 553 022 105 025 246 018 857 043 005 069 079 067 731 067 007 054 261 059 802 130 146 141 921 141 929 141 933 042 129 041 108 045 024 042 695
124 909 024 563 045 653 069 006 024 902 062 398 124 912 020 873 063 116 087 837 046 007 063 118 125 507 022 619 063 786 049 969 130 117 141 919 141 923 141 931 141 935 041 105 041 116 052 059 042 329
050 483 055 788 056 984
043 324 088 420 041 858
050 979 019 078 063 625 041 137
041 139
041 141
041 147
043 129
042 696
042 903
069 917 078 556 061 077 022 340 067 160 020 528 124 922
066 230 086 921 020 550 044 693 138 316
022 294 078 559 053 406 085 599 066 033 066 032 124 925
124 927
124 928
124 930
124 932 124 937
124 933 124 938
124 935 124 940
Brass Stainless steel PP PVDF PP Brass Brass
4.0 E
F T
NBR
3.0 3.0 4.0 4.0 4.0 4.0 4.0 2.0
FKM EPDM FKM FKM EPDM FKM EPDM FKM
3.0
FKM
Brass PP PP PP PVDF PP PP PP Brass
2.0 3.0 2)
FKM FKM
Brass Stainless steel Stainless steel
The listed ID numbers and circuit functions have a body with a straight channel
Note: Further versions on request
Mounting plate cpl. for DIN rail mounting
Valve
Item no.
Description
Order chart for accessories
013 253
Mounting plate cpl.
p. 6/12
0330 Ex
Explosion proof version Technical data Available body materials Port connection Seal material Medium for NBR
Circuit function
2 (A)
A 2/2 way direct-acting solenoid valve, normally closed
1 (P) 2 (B)
B 2/2 way direct-acting solenoid valve, normally open
1 (P) 2(A)
C 3/2 way direct-acting solenoid valve, normally closed
12
D 3/2 way direct-acting solenoid valve, normally open
10
1(P)
3(R)
Neutral medium such as compressed air, town gas, water, hydraulic oil, oils and fats without additives, oxygen for EPDM Alkalis, acids to medium concentrations, alkaline washing and bleaching lyes for FKM Oxydizing acids and substances, hot oils with additives, salt solutions, waste gases, oxygen for FFKM Aggressive mediums, hot air, hot oils All Materials - For more exact info. please refer to our chemical resistance chart Medium temperature NBR 0 to +80 °C for body material EPDM -30 to +90°C brass or stainless FKM 0 to +90 °C steel FFKM +5 to 90°C Medium temperature NBR 0 to +80 °C for body material EPDM -30 to +80°C PP or PVDF FKM 0 to +80 °C FFKM +5 to +80°C Viscosity Max. 37mm²/s Ambient temperature. Max. +55°C Voltages 24V, 230V (further voltages on request) Frequency AC/DC Voltage tolerance +/- 10% Duty cycle 100% Electrical connection Moulded cable (For more detailed information, refer to the instruction manual ACP016, chapter 7.6.1)
2(B)
1(P)
2(A)
E 3/2 way mixing solenoid valve
F 3/2 way direct-acting, distribution solenoid valve
3(R)
3/2 way direct-acting solenoid valve, flow direction optional
Protection class Coil insulation class Type of protection
1(P1)
3(P2)
Certificate
4(A)
2(B)
Installation
1(P)
T
NC
NO
Brass, stainless steel (1.4401), PP (Polypropylene) PVDF (Polyvinylfluoride) G 1/4; NPT 1/4; (RC 1/4 and G 1/8 on request) EDPM / FKM / FFKM / NBR
Terminal box without safety fuse IP65 H II 2 G Ex mb IIC T4 Gb II 2 D EX mb IIIC T130° Db EPS 16 ATEX 1 111 X IECEx EPS 16.0049X As required, preferably with actuator upright
Cycling rate Variant 1 Variant 2
Max. cycling rate 20/min 5/min
For mediums temp Up to +70 °C Up to +90 °C
For ambient temp. Up to +40 °C Up to +40 °C
Power consumption Inrush [W] 40
Operation [W] 3
Response times Orifice [mm] 2-4
Opening [ms] 30
Closing [ms] 40
Response times [ms]: Measured at valve outlet at 6 bar and +20 °C Opening: Pressure rise 0 to 90%, Closing: Pressure drop 100 to 10%
p. 7/12
0330 Ex
Technical data (continued) Pressure range and flow rate for metal body Circuit function
A/B/C/D/F
E
T
DN
2.0 3.0 4.0 5.0 2.0 3.0 4.0 5.0 2.0 3.0
Kv value water [m3/h]
0.11 0.18 0.23 0.29 0.11 0.18 0.23 0.29 0.11 0.18
Standard Pressure range
2) 3)
[bar]
2) 3)
[bar]
0 - 16 0 - 10 0–5 0–4 0 – 10 0–6 0 – 3.5 0–3 0 – 10 0–6
Vacuum Pressure range [bar] -0.98 – 10 -0.98 – 6 -0.98 – 3 -0.98 – 2.5 -0.98 – 8 -0.98 – 5 -0.98 – 2.5 -0.98 – 2 -0.98 – 8 -0.98 – 5
Pressure range and flow rate for plastic body Circuit function
A/B/C/D/F
E/T
DN
2.0 3.0 4.0 5.0 2.0 3.0 4.0
Kv value water [m3/h]
0.13 0.25 0.30 0.40 0.13 0.25 0.30
Standard Pressure range 0 - 16 0 – 10 0–5 0 – 4.5 0 - 10 0–6 0–3
Vacuum Pressure range [bar] -0.98 – 10 -0.98 – 6 -0.98 – 3 -0.98 – 1 -0.98 – 7 -0.98 – 5 -0.98 – 2.5
1)
Measured at +20 °C, 1 bar2) pressure at valve inlet and free outlet. Devices with FKM or FFKM diaphragm are reduced to a max. pressure of 12 bar 3) Pressure data [bar]: Measured as overpressure to the atmospheric pressure 2)
p. 8/12
0330 Ex
Other circuit functions The valves are fitted with different springs for a specific circuit function. When used in other circuit functions the permissable operating pressure changes acc. to the following table. Metal body Valve operation
Max. operating pressure [bar] when using the valve in a new circuit function Orifice 2mm A1)
C D T
16 4 8
B1) 1.5 16 8
Orifice 3mm C 16 4.5 10
D 1.5 16 10
E 1.5 4 10
F 16 4 8
A 10 2.5 6
B 1 10 6
Orifice 4mm C 10 2.5 6
D 1 10 6
E 1 2 6
F 10 3 6
A 5 2 3
B 0.8 5 3
C 5 2 3
D 0.8 5 3
E 0.8 2 3
F 5 2 3
C 5 2 4
D 0.8 5 1
E 0.8 2 1
F 5 2
Plastic body Valve operation C D F 1)
Max. operating pressure [bar] when using the valve in a new circuit function Orifice 2mm A1) 16 4 16
B1) 1.5 16 1.5
Orifice 3mm C 16 4.5 10
D 1.5 16 1.5
E 1.5 4 1.5
F 16 4 16
A 10 2.5 6
B 1 10 1
Orifice 4mm C 10 2.5 6
D 1 10 1
E 1 2 1
F 10 3 10
A 5 2 4
B 0.8 5 1
For circuit function A and B the valve must be connected acc. to the pin assignment of 3/2-way valve.
Additional options Option Oxygen versions
Increased purity requirements e.g. oil, grease and silicone-free Increased hermetic requirements Vacuum version Increased purity and hermetic requirements Increased purity and hermetic requirements and vacuum version Electrical feedback
Variable Code NL02
Description
Suitable for applications with oxygen (non-metal materials that are in contact with the medium, are tested and approved according to BAM) NL50/NL05 Wetted parts are specially cleaned and packaged in accordance with the valves PCxx Standard units are tested at 10-2 mbar x l / sec; feasable up to 10-6 mbar NA02 Suitable for vacuums up to -0.98bar NA03 Wetted parts are specially cleaned and leak tested to 10-4 mbar x l/sec NA01 Wetted parts are specially cleaned and leak tested up to 10-4 mbar x l/sec and suited for vacuum up to -0.98 bar CF15 Coil with intrinsically safe proximity switches (PTB 00 ATEX 2048X) instead of manual override
p. 9/12
0330 Ex
Dimensions [mm] Terminal connection box version
45°
D
D 9
36.6 54
9
100.3 95.3
cable gland M20x1.5 or NPT 1/2-14
18
Swing radius of cover R84
L
7.5 32 64.6 74.4
24 34.6
46 54.8
38 D1 G 1/8 G 1/4
98 130
L1 9 9
D2
L2
NPT 1/4 7.5
For G threads the dimensions D1 and L1are valid For NPT threads the dimensions D2 and L2 are valid
Cable outlet version
D 9
18
36.6
9
Cable length according order
L 46 55.8
24 34.6
40.7
6.2
78.5
38
p. 10/12
0330 Ex
Port connections The connections marked with 1, 2 and 3 are labelled in the drawing according to the circuit function table on the left. Circuit function A B C D E F
Connection 1 Connection 2 Connection 3 P B P R P1 A
A P A B A P
R P P2 B
2
3
1
1
2
Ordering chart All devices with connection thread G 1/4 and manual override Circuit function
Orifice [mm]
Seal Material
Housing or seat material
Electrical connection
024/UC
230/UC
Item no. per voltage/ frequency [V/Hz]
A2)
3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 4.0 4.0
NBR NBR FKM FKM NBR NBR FKM FKM FKM FKM FKM FKM FKM FKM
MS MS Stainless steel Stainless steel MS MS Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel
Terminal box cable Terminal box cable Terminal box cable Terminal box cable Terminal box cable Terminal box cable Terminal box cable
306 165 306 005 306 168 306 007 304 531 305 982 306 154 306 003 306 171 306 009 306 198 306 011 306 151 306 050
306 167 306 006 306 169 306 008 306 149 305 985 306 164 306 004 306 157 306 010 306 172 306 012 – –
C
E F
Note: Further versions on request
p. 11/12
0330 Ex
Ex-Cable glands (polyamide version included in delivery / surcharge applied for brass nickel plated version
Brass. nickelplated, 6-13 mm
PTB 04 ATEX 1112 X, IECEx PTB 13.0027X
Polyamide, PTB 13 ATEX 1015 X, 7-13 mm IECEx PTB 13.0034X
II 2 G Ex e IIC Gb, II 2 D Ex tb IIIC Db IP68,
II 2 G Ex e IIC Gb, II 2 D Ex tb IIIC Db IP68
Drawing
Item no
Identification
Certification
Description
Photo
Ex Approvals
773 278
TL L D SW E
29-37 mm 6 mm 20 24 mm 27 mm
773 277
TL L D SW E
36-45 mm 10 mm 20 24 mm 28 mm
Set SC02-AC10 Special wrench Service Manual
To find your nearest Bürkert facility, click on the orange box In case of special application conditions, please consult for advice.
Item no.
Photo
Description
Special tool to turn the junction box (not included in delivery)
293 488
www.burkert.com
Subject to alterations © Christian Bürkert GmbH & Co. KG
1708/17_EU-en_00891622