Direct Gas Heat, 100 Degree Temp. Rise

   EMBED


Share

Transcript

INDUSTRIAL BELT DRIVE 16 ™ Direct Gas Heated Air Curtain 100° Temp. Rise Data Sheet For Door Heights To 16’ (environmental separation) STANDARD CONSTRUCTION • • • • • • • Single speed T.E.F.C. motor - belt drive Gray powder coated exterior (Optional: Custom Color or Stainless) Split cabinet construction for fan assembly removal Removable access panels Top Mounting only Front air intake (Optional: top) Motor location top right (Optional: top left, front left or front right) • Factory mounted duct transition with bottom access panels • Factory mounted modulating direct fired heater with FM/IRI gas train • Factory mounted wired heater control panel • Steel cabinet with gray finish • Spark ignited intermittent pilot 2 Year Limited Warranty MODEL Nozzle Width (in) Max Vel. at Nozzle (fpm) Avg. Outlet Vel. (fpm) IBC16-1060D 60.00 5,145 3,302 5,359 85% 2.80 1@3 581.9 3/4” 100° 425 82 220 IBC16-1072D 72.00 5,005 2,944 6,256 91% 2.90 1@3 679.5 3/4” 100° 471 97 220 IBC16-1084D 84.00 4,644 2,732 6,772 89% 3.00 1@3 734.7 3/4” 100° 517 112 220 IBC16-1096D 96.00 5,352 3,148 8,920 87% 4.10 1@5 968.4 1” 100° 623 121 270 IBC16-1108D 108.00 5,236 3,080 9,817 86% 4.20 1@5 1,065.1 1” 100° 749 136 270 IBC16-1120D 117.00 6,012 3,627 12,526 87% 4.80 1 @ 7.5 1,359.0 1 1/4” 100° 789 136 360 IBC16-1132D 132.00 5,602 3,296 12,839 86% 4.90 1 @ 7.5 1,393.5 1 1/4” 100° 846 154 360 IBC16-1144D 144.00 5,225 3,074 13,062 85% 5.40 1 @ 7.5 1,417.2 1 1/4” 100° 892 169 360 IBC16-1156D 156.00 4,943 2,908 13,388 84% 5.50 1 @ 7.5 1,452.7 1 1/4” 100° 948 178 400 IBC16-1168D 168.00 5,203 3,061 15,176 89% 7.00 1 @ 7.5 1,646.9 1 1/4” 100° 1,059 193 400 IBC16-1180D 180.00 5,143 3,026 16,073 87% 7.10 1 @ 7.5 1,744.6 1 1/4” 100° 1,130 202 440 IBC16-1192D 192.00 5,352 3,148 17,840 87% 8.20 1 @ 10 1,935.9 1 1/4” 100° 1,201 217 440 Air Outlet Power Heater Motor Volume Vel. Rating Output @ HP (cfm) Uniformity (kW) (MBH) Max Net Wt. Net Wt. Net Wt. Gas Air Temp. Air Duct Burner Train Rise Curtain Trans. Box Size (°F) (lbs) (lbs) (lbs) NOTES: 1. Operation at 50 Hz will generate approximately a 17% reduction in performance. 2. Performance data based on AMCA licensed data from unheated IDC16 units. 3. Maximum leaving air temperature shall not exceed 120°F. 4. Duct transition and direct fired gas heater are factory mounted to air curtain and each require individual support. 5. Gas supply pressure: minimum 1 psi, maximum 5 psi. 6. Vertically mounted Industrial Belt Drive air curtains not available. 7. Gas train size is not the main gas supply line size. See sheet EP-439 for amp draws/total load requirements. MODEL NUMBER CONFIGURATION IBC16-1 060 D D-F T-SS Series # of Motors IBC16 1 Opening Width 060” - 192” Heat D=Direct Gas Heated Voltage D=208/3/60 E=240/3/60 H=480/3/60 I=600/3/60 T=380/3/50 Intake Motor Location T=Top T=Top F=Front F=Front Opt. Cabinet Finish SS=Stainless Steel CC=Custom Color Sound level measured 10’ (3m) from the unit in free field: 3, 5, 7½ & 10 hp motor(s): 68 dBA, 70 dBA, 72 dBA & 73 dBA Berner reserves the right to alter specifications without prior notice. www.berner.com Berner International Corporation 111 Progress Ave. / New Castle / PA / 16101 / USA 800.245.4455 DS-439B July, 2015 ©Copyright, 2015 Berner International Corporation INDUSTRIAL BELT DRIVE 16 ™ Direct Gas Heated Air Curtain Electrical Performance Sheet 208/3/60 (voltage code D) 240/3/60 (voltage code E) 480/3/60 (voltage code H) MOTOR AMP DRAW PER HP MOTOR AMP DRAW PER HP MOTOR AMP DRAW PER HP MODEL Qty @ HP # CKTS AMPS PER CIRCUIT BREAKER RATING PER CIRCUIT # CKTS AMPS PER CIRCUIT BREAKER RATING PER CIRCUIT # CKTS AMPS PER CIRCUIT BREAKER RATING PER CIRCUIT IBC16-1060D IBC16-1072D IBC16-1084D 1@3 1 12.0 15 1 10.9 15 1 5.5 15 IBC16-1096D IBC16-1108D 1@5 1 17.2 30 1 15.4 30 1 7.8 15 IBC16-1120D IBC16-1132D IBC16-1144D IBC16-1156D IBC16-1168D IBC16-1180D 1 @ 7.5 1 23.6 50 1 21.3 45 1 10.7 25 IBC16-1192D 1 @ 10 1 30.1 60 1 27.0 60 1 13.6 30 600/3/60 (voltage code I) 380/3/50 (voltage code T) MOTOR AMP DRAW PER HP MOTOR AMP DRAW PER HP MODEL Qty @ HP # CKTS AMPS PER CIRCUIT BREAKER RATING PER CIRCUIT # CKTS AMPS PER CIRCUIT BREAKER RATING PER CIRCUIT IBC16-1060D IBC16-1072D IBC16-1084D 1@3 1 4.5 15 1 5.9 15 IBC16-1096D IBC16-1108D 1@5 1 6.4 15 1 6.4 15 IBC16-1120D IBC16-1132D IBC16-1144D IBC16-1156D IBC16-1168D IBC16-1180D 1 @ 7.5 1 8.5 15 1 11.1 25 IBC16-1192D 1 @ 10 1 10.9 20 1 14.0 30 * Includes 750VA transformer load for gas fired burner panel. Berner reserves the right to alter specifications without prior notice. www.berner.com Berner International Corporation 111 Progress Ave. / New Castle / PA / 16101 / USA 800.245-4455 EP-439 June, 2015 ©Copyright, 2015 Berner International Corporation