Direct Immersion Resistance Thermometer Configurations

   EMBED


Share

Transcript

DIRECT IMMERSION RESISTANCE THERMOMETER CONFIGURATIONS WIRE & REMOTE CONNECTION BOX II 2G/D Ex d PRA-PT100WD D19-PRA PRA All specifications are subject to change without notice © Rodax Antwerp Belgium F-D0502NOV13 E-mail: [email protected] 1 Features Technical specification High quality RTD element with MgO mineral insulated metal sheathed cable, providing excellent stability and reproducibility. • The unique properties make this basic element ideally suited for a wide variety of applications up to 600°C . • • Lead wire with flexible stainless steel hose and Ex d certified cable gland The connection head has 4x ½”NPT threads. 2 off plugged. The PT100 is bendable over the total length except on the tip over 50 mm. • • • • • • Connection head 4x ½”NPT Aluminium Epoxy coated RAL 7035 with 2” pipe mounting bracket SS304 • Terminal block Code CB: ceramic block Code RB: high tech thermoplast: moisture and Shock-proof Code TP :mounting plate for transmitter • Adjustable compression fitting :optional High vibration resistant models available. ATEX : code A G=gas D=Dust Max. temperature depending on thermocouple type and metal sheath Minimum insulation resistance : 1000 MOhm at 500VDC, ambient Metal sheath: see list. Transition: standard permissible temperature 250°C. Welded attachment of sheath to transition Accuracy according to DIN- IEC-EN 60584 class 1 Lead wire: Teflon with stainless steel Hose Wire gauge size : standard AWG24 Cable gland: for SS Hose and wire OD3.2-8.7 IECEx : code I All specifications are subject to change without notice © Rodax Antwerp Belgium F-D0502NOV13 E-mail: [email protected] G=gas D=Dust 2 Technical specification sensor S D Single Dual A1 A2 A3 A5 A6 A10 Class A Class B 1/3 DIN 1/5 DIN 1/6 DIN 1/10 DIN IEC DIN EN 60751 ±(0.15+0.002│t│)°C IEC DIN EN 60751 ±(0.30+0.005│t│)°C 1/3 class B 1/5 class B 1/6 class B 1/10 class B PT100 Element Accuracy Diameter Connection ATEX/IEC HV: High vibration D3 D3.2 D4.5 D4.8 D6 D6.35 3 mm 3.2 mm 4.5 mm 4.8 mm 6 mm 6.35 mm W2 W3 W4 (*) (*) for OD 3/3.2 /4.5/4.8 mm : dual sensors max 2x3 wire For all our sensors with outside diameter 3 mm and up, the following routine test has been done: -500V AC during 1 minute at Tamb 20°C MF1 Lead wire Teflon MF2 ® Extruded FEP Max +260°C D (mm) Transition Options Kapton SS304 hose over lead wire ® other On request Polyimide tape Max -80/+360°C Tmax Standard Standard STD 25 STD 290°C ORDERING INFORMATION D19-PRA Sensor with lead wire and connection head PRA Sensor with lead wire ( spare part for D19 ) Terminal connection in the head CB RB TP Ceramic block 2/3/4/6/8 terminals Hi tech block 2/3/6 terminals Mounting plate for transmitter Code Certificates Q410FT Functional test report (up-down) All specifications are subject to change without notice © Rodax Antwerp Belgium F-D0502NOV13 E-mail: [email protected] 3 Q440CR Calibration report 100°C . Q450CR Calibration report on 100°C and 1 up to 4 points in the range of -10/600°C Q460CR Calibration report by accredited calibration lab ( measuring points to be indicated) Q510TR Transmitter programming. Range and burn-out settings to be specified. Q820CC Test report EN10204-2.2 HOW TO ORDER (example) Code Example Model Assembly D19 PT100 PT100 type PRA Terminal CB or RB or TP CB Protection A : Atex I : IECEx A Environment G: Gas D: Dust G Single/dual S: Single D: Dual Accuracy Class as per EN60751 A1 Diameter Outside diameter sensor D6 Connection N° of wires W3 Le Total length in mm below transition Le 150 Wire Type of wire MF1 AWG Wire gauge size AWG24 E Lead wire length in mm E1000 Options Adjustable compression fitting; certificates T: Triple Your code S 0rdering code example: D19 PRA CB A G S A1 D6 W3 Le150 MF1 AWG24 E1000 For all options: please contact Rodax All specifications are subject to change without notice © Rodax Antwerp Belgium F-D0502NOV13 E-mail: [email protected] 4