Transcript
DIRIS A40/A41
RS485 – PROFIBUS® DP Operating instructions GB
D
I
NL
E
ON
1
F
CO
PROFIBUS® Certification
M
P
2
SOCOMEC - Réf. : 876 786 A GB
Contents
GB PRELIMINARY OPERATIONS_____________________ 4 GENERAL INFORMATION _______________________ 4 INSTALLATION _________________________________ 5 PROGRAMMING _______________________________ 6 CONFIGURATION _____________________________ 10 USE OF PROFIBUS®-DP MODULES _____________ 15 MODULE 1: MAIN MEASUREMENTS ___________ 15 MODULE 2: ADDITIONAL MEASUREMENTS_____ 20 MODULE 3: TROUGH/POWER CUT/ MEAN POWER ____________________ 22 MODULE 4: OVERVOLTAGE/MEAN VOLTAGE AND FREQUENCIES/MAXIMUM AND MEAN In_____________________ 23 MODULE 5: CURRENT HARMONICS ___________ 24 MODULE 6: PHASE TO PHASE VOLTAGE _______ 25 MODULE 7: PHASE TO NEUTRAL VOLTAGE_____ 26 MODULE 8: INSTANTANEOUS MIN/MAX ________ 27 MODULE 9: SPECIAL FRAME__________________ 28 MODULE 11: LIMITED SPECIAL FRAME ________ 35 DIAGNOSTICS ________________________________ 37 TECHNICAL CHARACTERISTICS________________ 39 PROFIBUS® CERTIFICATION ____________________ 40
SOCOMEC - Réf. : 876 786 A GB
3
DIRIS A40/A41 - RS485 - PROFIBUS® DP
PRELIMINARY OPERATIONS
For personnel and product safety please read the contents of these operating instructions carefully before connecting. Check the following points as soon as you receive the Diris A40/A41 package: • the packing is in good condition, • the product has not been damaged during transit,
• the product reference number conforms to your order, • the package contains 2 option modules, the first of which is equipped with a disconnectable terminal block, • a CD-Rom.
GENERAL INFORMATION Functions
General points
This optional module must be connected to the DIRIS A40/A41 (ref. 4825 0A40, 4825 0A41, 4825 1A40, 4825 1A41). It provides an RS485 serial link (2 or 3 wires) with PROFIBUS® DP protocol for the use of DIRIS A40/A41 from a PC or PLC.
In a standard configuration, an RS485 link allows 1 to 32 DIRIS A40/A41 to be linked to 1 to 32 pieces of equipment using the PROFIBUS®-DP protocol. The maximum communication speed is 1.5 Mbauds over 200 m. This distance can be increased if the speed is reduced (Standards: EN50170).
앓 1500 M
N° 1
N° 2
N° n
DIRIS 699 A GB
Programmable controllers Other systems
앓 1500 M
N° 1
앓 1500 M
0+- -+0 repetor
N° n
RS485 DIRIS 700 A GB
Programmable controllers Other systems
Recommendations: You should use a garantieed cable PROFIBUS.
4
NB : It is essential to attach an active termination to the 2 link-up ends. This termination can be found on the model RS 485. Remember to put the 2 switches to ON when attaching.
SOCOMEC - Réf. : 876 786 A GB
DIRIS A40/A41 - RS485 - PROFIBUS® DP
INSTALLATION
CONNECTION The option modules are installed on the rear panel of the DIRIS A40/A41 in one of the four positions provided.
GB
The DIRIS A40/A41 must be switched off
DIRIS 342 A
DIRIS 343 A
Fix the option modules next to each other
ON
1
-+
ON
0V
1
Follow indications when connecting the terminal Switch on voltage supply
M
DIRIS 469 B
CO
Note : Correspondence with a HAN BRID connector + = B (red) - = A (green)
SOCOMEC - Réf. : 876 786 A GB
5
DIRIS A40/A41 - RS485 - PROFIBUS® DP
PROGRAMMATION
Previous menu
p.7
p.8
p.9
Following menu
6
SOCOMEC - Réf. : 876 786 A GB
DIRIS A40/A41 - RS485 - PROFIBUS® DP PROGRAMMATION
COMMUNICATION ADDRESS
GB
> Example : COM ADR = 7
x3
x2
x1 confirm
SOCOMEC - Réf. : 876 786 A GB
7
DIRIS A40/A41 - RS485 - PROFIBUS® DP
PROGRAMMATION
DIAGNOSTIQUE > Example : COM DIAG = NO
x1
x 1 (NO) x 2 (YES)
x1 confirm
NB : This function allows switching the diagnosis function or off. (see p. 37)
8
SOCOMEC - Réf. : 876 786 A GB
DIRIS A40/A41 - RS485 - PROFIBUS® DP PROGRAMMATION
GB
ACTIVATION OF THE PROGRAMME VIA THE PROFIBUS MASTER > Example : COM PARA = YES
x1
x 1 (YES) x 2 (NO)
x1 confirm
Nb : This function allows activating or deactivation of the DIRIS programming by the PROFIBUS DP master. If this function is deactivated please note that in case of loss of the slave (DIRIS) the master will not send the GSD file parameters and thus won’t re-programme the DIRIS A with the factory parameters.
SOCOMEC - Réf. : 876 786 A GB
9
DIRIS A40/A41 - RS485 - PROFIBUS® DP
CONFIGURATION
The table below gives the configuration of the DIRIS A40/A41 used when starting a PROFIBUS®-DP cycle. Name Manufacturer parameter Always equal to zero Network type 0 : 1 BL 1 : 2 BL 2 : 3 BL 3 : 3 NBL 4 : 4 BL 5 : 4 NBL CT secondary (A) 1:1A 5:5A CT primary (A) Voltage input on PT 0 : No 1 : Yes PT primary (V) PT secondary (V) 60 : 60 V 100 : 100 V 110 : 110 V 115 : 115 V 120 : 120 V 173 : 173 V 190 : 190 V Synchronisation of I AVG / MAX 5 : 5 mn 8 : 8 mn 10 : 10 mn 15 : 15 mn 20 : 20 mn 30 : 30 mn 60 : 60 mn Synchronisation of P / Q / S AVG / MAX 5 : 5 mn 8 : 8 mn 10 : 10 mn 15 : 15 mn 20 : 20 mn 30 : 30 mn 60 : 60 mn OUT 1 allocation 0 : kWh+ 1 : kvarh+ 2 : kVAh 3 : kWh4 : kvarhOUT 1 impulse value (kWh / kvarh / kVAh) 0 : 0,1 1:1 2 : 10
10
Size (bytes) 1 1
1
2 1
4 1
1
1
1
1
SOCOMEC - Réf. : 876 786 A GB
DIRIS A40/A41 - RS485 - PROFIBUS® DP CONFIGURATION
3 : 100 4 : 1000 5 : 10000 OUT 1 impulse duration (ms) 1 : 100 2 : 200 3 : 300 4 : 400 5 : 500 6 : 600 7 : 700 8 : 800 9 : 900 OUT 2 allocation 0 : kWh+ 1 : kvarh+ 2 : kVAh 3 : kWh4 : kvarhOUT 2 impulse value (kWh / kvarh / kVAh) 0 : 0,1 1:1 2 : 10 3 : 100 4 : 1000 5 : 10000 OUT 2 impulse duration (ms) 1 : 100 2 : 200 3 : 300 4 : 400 5 : 500 6 : 600 7 : 700 8 : 800 9 : 900 Analog output type OUT 1 0 : 0 / 20 mA 1 : 4 / 20 mA 2 : Alim Allocation of analog output OUT 1 0 : I1 1 : I2 2 : I3 3 : In 4 : U12 5 : U23 6 : U31 7:P 8:Q 9:S
SOCOMEC - Réf. : 876 786 A GB
Size (bytes)
1
GB
Name
1
1
1
1
1
11
DIRIS A40/A41 - RS485 - PROFIBUS® DP
CONFIGURATION
Name 10 : PF 11 : V1 12 : V2 13 : V3 14 : F Value at 0 or 4 mA from analog output OUT 1 Unit at 0 or 4 mA from analog output OUT 1 0:/ 1:k 2:M Value at 20 mA from analog output OUT 1 Unit at 20 mA from analog output OUT 1 0:/ 1:k 2:M Analog output type OUT 2 0 : 0 / 20 mA 1 : 4 / 20 mA 2 : Alim Allocation of analog output OUT 2 0 : I1 1 : I2 2 : I3 3 : In 4 : U12 5 : U23 6 : U31 7:P 8:Q 9:S 10 : PF 11 : V1 12 : V2 13 : V3 14 : F Value at 0 or 4 mA from analog output OUT 2 Unit at 0 or 4 mA from analog output OUT 2 0:/ 1:k 2:M Value at 20 mA from analog output OUT 2 Unit at 20 mA from analog output OUT 2 0:/ 1:k 2:M Analog output type OUT 3 0 : 0 / 20 mA 1 : 4 / 20 mA 2 : Supply
12
Size (bytes)
2 1
2 1
1
1
2 1
2 1
1
SOCOMEC - Réf. : 876 786 A GB
DIRIS A40/A41 - RS485 - PROFIBUS® DP CONFIGURATION
Allocation of analog output OUT 3 0 : I1 1 : I2 2 : I3 3 : In 4 : U12 5 : U23 6 : U31 7:P 8:Q 9:S 10 : PF 11 : V1 12 : V2 13 : V3 14 : F Value at 0 or 4 mA from analog output OUT 3 Unit at 0 or 4 mA from analog output OUT 3 0:/ 1:k 2:M Value at 20 mA from analog output OUT 3 Unit at 20 mA from analog output OUT 3 0:/ 1:k 2:M Analog output type OUT 4 0 : 0 / 20 mA 1 : 4 / 20 mA 2 : Supply Allocation of analog output OUT 4 0 : I1 1 : I2 2 : I3 3 : In 4 : U12 5 : U23 6 : U31 7:P 8:Q 9:S 10 : PF 11 : V1 12 : V2 13 : V3 14 : F Value at 0 or 4 mA from analog output OUT 4 Unit at 0 or 4 mA from analog output OUT 4 0:/ 1:k 2:M
SOCOMEC - Réf. : 876 786 A GB
Size (bytes) 1
GB
Name
2 1
2 1
1
1
2 1
13
DIRIS A40/A41 - RS485 - PROFIBUS® DP
CONFIGURATION
Name Value at 20 mA from analog output OUT 4 Unit at 20 mA from analog output OUT 4 0:/ 1:k 2:M CT In secondary (A) 1:1A 5:5A CT In primary (A)
Size (bytes) 2 1
1
2
Length: 54 bytes NB: All this information is integrated in the GSD file (User-Prm-Data).
Check that the parameterisation data are identical to the data programmed in the device. When the PROFIBUS® master loses a slave, it re-injects the parameters from the GSD file which will re set the factory configuration. There are two solutions to inhibit this function: - Deactivate the master’s DIRIS A programming (see also page 9) - Configure the DIRIS A through the master, then open and close the DIRIS A programming menu directly by the keypad (code =100).
14
SOCOMEC - Réf. : 876 786 A GB
DIRIS A40/A41 - RS485 - PROFIBUS® DP
USE OF THE PROFIBUS®-DP MODULES The modules contain the inputs (display) and outputs (configuration).
MODULE 1: MAIN MEASUREMENTS This module contains the currents, powers, frequencies, power factor, positive energies and hour meter.
Example: Modification of relay 1: • set bit 4 (relay configuration change), • set bit 0 (relay 1 to 1), • modify the status byte on relay 1 break (next byte).
Name Change of relay status if bit on 1, then taken into account, otherwise bit on 0 bit 0: Relay 1 bit 1: Relay 2 bit 2: Relay 3 (second option relay 1) bit 3: Relay 4 (second option relay 2) bit 4: Change in relay configuration bit 5: Resetting of one measurement bit 6: not used bit 7: not used Relay 1 on break 0: open 1: closed Relay 2 on break 0: open 1: closed Relay 3 on break 0: open 1: closed Relay 4 on break 0: open 1: closed Allocation OUT 1 0: Cde 1: I 2: U 3: P+ 4: Q+ 5: S 6: F 7: PFL 8: Thd 3I 9: Thd 3U 10: In 11: time 12: V 13: Thd In 14: Thd 3V 15: P16: Q17: PFC Lower threshold OUT 1 Lower threshold unit OUT 1 0: / 1: k 2: M Upper threshold OUT 1
SOCOMEC - Réf. : 876 786 A GB
GB
Output frame Size (bytes) 1
1
1
1
1
1
2 1
2
15
DIRIS A40/A41 - RS485 - PROFIBUS® DP
USE OF THE PROFIBUS®-DP MODULES
MODULE 1: MAIN MEASUREMENTS Output frame Name Upper threshold unit OUT 1 0: / 1: k 2: M Hysteresis 0 to 99 OUT 1 (%) Time delay OUT 1 (s) Allocation OUT 2 0: Cde 1: I 2: U 3: P+ 4: Q+ 5: S 6: F 7: PFL 8: Thd 3I 9: Thd 3U 10: In 11: time 12: V 13: Thd In 14: Thd 3V 15: P16: Q17: PFC Lower threshold OUT 2 Lower threshold unit OUT 2 0: / 1: k 2: M Upper threshold OUT 2 Upper threshold unit OUT 2 0: / 1: k 2: M Hysteresis 0 to 99 OUT 2 (%) Time delay OUT 2 (s) Zero reset bit 0: Max 3I bit 1: Max P+ bit 2: Max Pbit 3: Max Q+ bit 4: Max Qbit 5: Max S bit 6: hour meter bit 7: kWh+ bit 8: kvarh+ bit 9: kVA bit 10: kWhbit 11: kvarhbit 12: all the parameters bit 13: Input 1 bit 14: Input2 bit 15: not used
16
Size (bytes) 1
1 2 1
2 1
2 1
1 2 2
SOCOMEC - Réf. : 876 786 A GB
DIRIS A40/A41 - RS485 - PROFIBUS® DP USE OF THE PROFIBUS®-DP MODULES
MODULE 1: MAIN MEASUREMENTS Output frame
Zero reset, supplementary options bit 0: Input 1 bit 1: Input 2 bit 2: Input 3 bit 3: Input 4 bit 4: Not used bit 5: Not used bit 6: Min Max I bit 7: Min Max In bit 8: Min Max U bit 9: Min Max Frequency bit 10: Min Max PF bit 11: Min Max P bit 12: Min Max Q bit 13: Min Max Thd I bit 14: Min Max Thd In bit 15: Min Max Thd U Length: 29 bytes
SOCOMEC - Réf. : 876 786 A GB
Size (bytes) 2
GB
Name
17
DIRIS A40/A41 - RS485 - PROFIBUS® DP
USE OF THE PROFIBUS®-DP MODULES
MODULE 1: MAIN MEASUREMENTS Frame of inputs not allocated for current and voltage transformation ratios Name Phase 1 current (mA) Phase 2 current (mA) Phase 3 current (mA) Neutral current (mA) Phase to phase voltage U12 (V / 10) Phase to phase voltage U23 (V / 10) Phase to phase voltage U31 (V / 10) Phase to neutral voltage phase 1 (V / 10) Phase to neutral voltage phase 2 (V / 10) Phase to neutral voltage phase 3 (V / 10) Frequency (Hz / 100) ∑ Active power + /- (kW / 10) ∑ Reactive power + /- (kvar / 10) ∑ Apparent power + /- (kVa / 10) ∑ Power factor L / C -: capacitive and +: inductive (0.001) I1 max (mA) I2 max (mA) I3 max (mA) Maximum value active power + (W) Maximum value active power – (W) Maximum value reactive power + (var) Maximum value reactive power – (var) Maximum apparent power (VA) Active energy + < 10000 (kWh) Active energy + > 10000 (kWh) Reactive energy + < 10000 (kvarh) Reactive energy + > 10000 (kvarh) Apparent energy < 10000 (kVAh) Apparent energy > 10000 (kVAh) System I (mA) System U (V / 10) System V (V / 10) Hour meter < 10000 (H / 100) Hour meter >10000 (H / 100)
Size (bytes) 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
Length: 68 bytes
18
SOCOMEC - Réf. : 876 786 A GB
DIRIS A40/A41 - RS485 - PROFIBUS® DP USE OF THE PROFIBUS®-DP MODULES
GB
Calculation of the values allocated: The currents must be multiplied by the CT ratio, the voltages by the PT ratio (in HV) and the powers by the ratio CT x PT. Example: CT = 100 = 20 VT = 20000 = 200 5 100 CT x VT = 20 x 200 = 4000 Powers will be multiplied by 4000 (if there is no VT, then VT = 1), currents by 20 and voltages by 200. NB : I system =
I1 + I2 + I3 3
U system =
U12 + U21 + U31 3
V system =
V1 + V2 + V3 3
Transformation of signed values into unsigned values If the currents, voltages or energies are negative, the following rule must be applied: • take the opposite bit by bit of the datum • add 1 to this opposite Example: • negative datum - 28864mv or in binary : 0111 0000 1100 0000 • opposite is equal to : 1000 1111 0011 1111 • opposite + 1 is equal to : 1000 1111 0100 0000 or in decimal 366,72.
SOCOMEC - Réf. : 876 786 A GB
19
DIRIS A40/A41 - RS485 - PROFIBUS® DP
USE OF THE PROFIBUS®-DP MODULES
MODULE 2: SUPPLEMENTARY MEASUREMENTS This module contains the measurements by phase, average values, negative energies, impulse meters (on / off inputs) and statuses (on / off inputs). The output frame is identical to module 1. Input frame Name Active power phase 1 + /- (kW/10) Active power phase 2 + /- (kW/10) Active power phase 3 + /- (kW/10) Reactive power phase 1 + /- (kvar/10) Reactive power phase 2 + /- (kvar/10) Reactive power phase 3 + /- (kvar/10) Apparent power phase 1 (kVA/10) Apparent power phase 2 (kVA/10) Apparent power phase 3 (kVA/10) Power factor phase 1 (0.001) -: capacitive and +: inductive Power factor phase 2 (0.001) -: capacitive and +: inductive Power factor phase 3 (0.001) -: capacitive and +: inductive Average value I1 (mA) Average value I2 (mA) Average value I3 (mA) Average value active power + (W) Average value active power - (W) Average value reactive power + (var) Average value reactive power - (var) Average value apparent power (VA) Active energy - < 10000 (kWh) Active energy - >10000 (kWh) Reactive energy - < 10000 (kvarh) Reactive energy - > 10000 (kvarh) Input pulse meter 1 < 10000 Input pulse meter 1 > 10000 Input pulse meter 2 < 10000 Input pulse meter 2 > 10000 Input pulse meter 3 < 10000 Input pulse meter 3 > 10000 Input pulse meter 4 < 10000 Input pulse meter 4 > 10000 Status inputs 1, 2, 3, 4.
Size (bytes) 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
Length: 66 bytes
20
SOCOMEC - Réf. : 876 786 A GB
DIRIS A40/A41 - RS485 - PROFIBUS® DP USE OF THE PROFIBUS®-DP MODULES
GB
Calculation of the values allocated: The currents must be multiplied by the CT ratio, the voltages by the PT ratio (in HV) and the powers by the CT x PT ratio. Example: CT = 100 = 20 VT = 20000 = 200 5 100 CT x VT = 20 x 200 = 4000 Powers will be multiplied by 4000 (if there is no VT, then VT = 1), currents by 20 and voltages by 200. Status of the inputs : input 1 = bit 0 input 2 = bit 1 input 3 = bit 2 input 4 = bit 4 If active the bit is on 1. If inactive the bit is on 0. Transformation of signed values into unsigned values If the currents, voltages or energies are negative, the following rule must be applied: • take the opposite bit by bit of the datum • add 1 to this opposite Example: • negative datum - 28864mv or in binary : 0111 0000 1100 0000 • opposite is equal to : 1000 1111 0011 1111 • opposite + 1 is equal to : 1000 1111 0100 0000 or in decimal 366,72 V.
SOCOMEC - Réf. : 876 786 A GB
21
DIRIS A40/A41 - RS485 - PROFIBUS® DP
USE OF THE PROFIBUS®-DP MODULES
MODULE 3: DIPS/INTERRUPTION/TREND POWERS AND FREQUENCY Name Last voltage dips Residual phase to phase voltage involved: 0: none, 5: U12, 6: U23, 7: U31 Value (V/100) Residual phase to neutral voltage involved: 0: none, 22 : V1, 23: V2, 24: V3 Value (V/100) Length (ms) Month Day Year Hour Minute Second Last power interruption Month Day Year Hour Minute Second Last average power Last P+ value (kW/10) Last P- value (kW/10) Last Q+ value (kvar/10) Last Q- value (kvar/10) Last average frequency Last frequency value (Hz/100)
Size (bytes) 1 4 1 4 4 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2
Length: 36 bytes
22
SOCOMEC - Réf. : 876 786 A GB
DIRIS A40/A41 - RS485 - PROFIBUS® DP USE OF THE PROFIBUS®-DP MODULES
MODULE 4: SWELL/TREND VOLTAGES/IN MAXIMUM AND AVERAGE
Last swell Maximum phase to phase voltage involved: 0: none, 5: U12, 6: U23, 7: U31 Value (V/100) Maximum phase to neutral voltage involved: 0: none, 22 : V1, 23: V2, 24: V3 Value (V/100) Length (ms) Month Day Year Hour Minute Second Average voltage Last phase to phase voltage value U12 (V/10) Last phase to phase voltage value U23 (V/10) Last phase to phase voltage value U31 (V/10) Last phase to neutral voltage value V1 (V/10) Last phase to neutral voltage value V2 (V/10) Last phase to neutral voltage value V3 (V/10) Average and maximum neutral current Average In (mA) Average maximum In (mA) Length: 36 bytes
SOCOMEC - Réf. : 876 786 A GB
Size (bytes) 1 4 1 4 4 1 1 1 1 1 1
GB
Name
2 2 2 2 2 2 2 2
23
DIRIS A40/A41 - RS485 - PROFIBUS® DP
USE OF THE PROFIBUS®-DP MODULES
MODULE 5: CURRENT HARMONICS This module contains the thd Is, the thd INs and the individual harmonics up to number 15. The output frame is identical to module 1. Input frame Name Thd I1 (0.1 %) Thd I2 (0.1 %) Thd I3 (0.1 %) Thd In (0.1 %) Harmonic I1 row Harmonic I2 row Harmonic I3 row Harmonic In row Harmonic I1 row Harmonic I2 row Harmonic I3 row Harmonic In row Harmonic I1 row Harmonic I2 row Harmonic I3 row Harmonic In row Harmonic I1 row Harmonic I2 row Harmonic I3 row Harmonic In row Harmonic I1 row Harmonic I2 row Harmonic I3 row Harmonic In row Harmonic I1 row Harmonic I2 row Harmonic I3 row Harmonic In row Harmonic I1 row Harmonic I2 row Harmonic I3 row Harmonic In row Length: 64 bytes
3 (0.1 %) 3 (0.1 %) 3 (0.1 %) 3 (0.1 %) 5 (0.1 %) 5 (0.1 %) 5 (0.1 %) 5 (0.1 %) 7 (0.1 %) 7 (0.1 %) 7 (0.1 %) 7 (0.1 %) 9 (0.1 %) 9 (0.1 %) 9 (0.1 %) 9 (0.1 %) 11 (0.1 %) 11 (0.1 %) 11 (0.1 %) 11 (0.1 %) 13 (0.1 %) 13 (0.1 %) 13 (0.1 %) 13 (0.1 %) 15 (0.1 %) 15 (0.1 %) 15 (0.1 %) 15 (0.1 %)
Size (bytes) 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
NB: The individual harmonics are available if the harmonic module is connected.
24
SOCOMEC - Réf. : 876 786 A GB
DIRIS A40/A41 - RS485 - PROFIBUS® DP USE OF THE PROFIBUS®-DP MODULES
MODULE 6: PHASE TO PHASE VOLTAGE HARMONICS This module contains the thd 3U and the individual harmonics up to number 15. The output frame is identical to module 1.
Thd U12 (0.1 %) Thd U23 (0.1 %) Thd U31 (0.1 %) Harmonic U12 row 3 (0.1 %) Harmonic U23 row 3 (0.1 %) Harmonic U31 row 3 (0.1 %) Harmonic U12 row 5 (0.1 %) Harmonic U23 row 5 (0.1 %) Harmonic U31 row 5 (0.1 %) Harmonic U12 row 7 (0.1 %) Harmonic U23 row 7 (0.1 %) Harmonic U31 row 7 (0.1 %) Harmonic U12 row 9 (0.1 %) Harmonic U23 row 9 (0.1 %) Harmonic U31 row 9 (0.1 %) Harmonic U12 row 11 (0.1 %) Harmonic U23 row 11 (0.1 %) Harmonic U31 row 11 (0.1 %) Harmonic U12 row 13 (0.1 %) Harmonic U23 row 13 (0.1 %) Harmonic U31 row 13 (0.1 %) Harmonic U12 row 15 (0.1 %) Harmonic U23 row 15 (0.1 %) Harmonic U31 row 15 (0.1 %) Length: 48 bytes NB: The individual harmonics are available if the harmonic module is connected.
SOCOMEC - Réf. : 876 786 A GB
Size (bytes) 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
GB
Input frame Name
25
DIRIS A40/A41 - RS485 - PROFIBUS® DP
USE OF THE PROFIBUS®-DP MODULES
MODULE 7: PHASE TO NEUTRAL VOLTAGE HARMONICS This module contains the thd 3V and the individual harmonics up to number 15. The output frame is identical to module 1. Input frame Name Thd V1 (0.1 %) Thd V2 (0.1 %) Thd V3 (0.1 %) Harmonic V1 row Harmonic V2 row Harmonic V3 row Harmonic V1 row Harmonic V2 row Harmonic V3 row Harmonic V1 row Harmonic V2 row Harmonic V3 row Harmonic V1 row Harmonic V2 row Harmonic V3 row Harmonic V1 row Harmonic V2 row Harmonic V3 row Harmonic V1 row Harmonic V2 row Harmonic V3 row Harmonic V1 row Harmonic V2 row Harmonic V3 row Length: 48 bytes
3 (0.1 %) 3 (0.1 %) 3 (0.1 %) 5 (0.1 %) 5 (0.1 %) 5 (0.1 %) 7 (0.1 %) 7 (0.1 %) 7 (0.1 %) 9 (0.1 %) 9 (0.1 %) 9 (0.1 %) 11 (0.1 %) 11 (0.1 %) 11 (0.1 %) 13 (0.1 %) 13 (0.1 %) 13 (0.1 %) 15 (0.1 %) 15 (0.1 %) 15 (0.1 %)
Size (bytes) 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
NB: The individual harmonics are available if the harmonic module is connected.
26
SOCOMEC - Réf. : 876 786 A GB
DIRIS A40/A41 - RS485 - PROFIBUS® DP USE OF THE PROFIBUS®-DP MODULES
MODULE 8: MIN / MAX INSTANTS
Input frame Name Min. current (mA) Min. neutral current (mA) Min. phase to phase voltage (V/10) Min. frequency (Hz/100) Min. power factor (0.001) Min. active power (W) Min. reactive power (var) Thd I min (0.1 %) Thd In min (0.1 %) Thd U min (0.1 %) Max. current (mA) Max. neutral current (mA) Max. phase to phase voltage (V/10) Max. frequency (Hz/100) Max. power factor (0.001) Max. active power (W) Max. reactive power (var) Thd I max (0.1 %) Thd In max (0.1 %) Thd U max (0.1 %) Length: 48 bytes
SOCOMEC - Réf. : 876 786 A GB
GB
This module contains the storage of the minimum and maximum values (if the 2 input / 2 output module is installed). The output frame is identical to module 1.
Size (bytes) 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
27
DIRIS A40/A41 - RS485 - PROFIBUS® DP
USE OF THE PROFIBUS®-DP MODULES
MODULE 9: SPECIAL FRAME This module allows the creation of a personalised
module.
Input frame If bit 7 is on 0, then the output frame is a normal frame Name
Size (bytes)
Change of relay status if bit on 1, then taken into account, otherwise bit on 0 bit 0: Relay 1 Example: bit 1: Relay 2 Modification of relay 1 : bit 2: Relay 3 (second option relay 1) • set bit 4 (relay configuration bit 3: Relay 4 (second option relay 1) change), bit 4: change in relay configuration • set bit 0 (relais 1 à 1), • modify the status byte on relay 1 bit 5: resetting of one measurement break (next byte). bit 6: not used bit 7: 0 -> configuration frame Relay 1 on break 0: open 1: closed Relay 2 on break 0: open 1: closed Relay 3 on break 0: open 1: closed Relay 4 on break 0: open 1: closed Allocation OUT 1 0: Command 1: I 2: U 3: P+ 4: Q+ 5: S 6: F 7: PFL 8: Thd 3I 9: Thd 3U 10: In 11: time 12: V 13: Thd In 14: Thd 3V 15: P16: Q17: PFC Lower threshold OUT 1 Lower threshold unit OUT 1 0: / 1: k 2: M Upper threshold OUT 1
28
1
1
1
1
1
1
2 1
2
SOCOMEC - Réf. : 876 786 A GB
DIRIS A40/A41 - RS485 - PROFIBUS® DP USE OF THE PROFIBUS®-DP MODULES
MODULE 9: SPECIAL FRAME Input frame
Upper threshold unit OUT 1 0: / 1: k 2: M Hysteresis 0 to 99 OUT 1 (%) Time delay OUT 1 (s) Allocation OUT 2: – 0: Cde 1: I 2: U 3: P+ 4: Q+ 5: S 6: F 7: PFL 8: Thd 3I 9: Thd 3U 10: In 11: time 12: V 13: Thd In 14: Thd 3V 15: P16: Q17: PFC Lower threshold OUT 2 Lower threshold unit OUT 2 0: / 1: k 2: M Upper threshold OUT 2 Upper threshold unit OUT 2 0: / 1: k 2: M Hysteresis 0 to 99 OUT 2 (%) Time delay OUT 2 (s) Zero reset bit 0: Max 3I bit 1: Max P+ bit 2: Max Pbit 3: Max Q+ bit 4: Max Qbit 5: Max S bit 6: hour meter bit 7: kWh+ bit 8: kvarh+ bit 9: kVA bit 10: kWhbit 11: kvarhbit 12: all the parameters bit 13: Input 1
SOCOMEC - Réf. : 876 786 A GB
Size (bytes) 1
GB
Name
1 2 1
2 1
2 1
1 2 2
29
DIRIS A40/A41 - RS485 - PROFIBUS® DP
USE OF THE PROFIBUS®-DP MODULES
MODULE 9: SPECIAL FRAME Input frame Name bit 14: Input2 bit 15: not used Zero reset, supplementary options bit 0: Input 1 bit 1: Input 2 bit 2: Input 3 bit 3: Input 4 bit 4: Input 5 bit 5: Input 6 bit 6: Min Max I bit 7: Min Max In bit 8: Min Max U bit 9: Min Max Frequency bit 10: Min Max PF bit 11: Min Max P bit 12: Min Max Q bit 13: Min Max Thd I bit 14: Min Max Thd In bit 15: Min Max Thd U Not used Length: 33 bytes
If the bit is on 1, then the output frame is as follows Name Frame number bit 0-6: frame number bit 7: 1 -> address frame Address of value 1 Address of value 2 Address of value 3 Address of value 4 Address of value 5 Address of value 6 Address of value 7 Address of value 8 Address of value 9 Address of value 10 Address of value 11 Address of value 12 Address of value 13 Address of value 14 Address of value 15 Address of value 16
Size (bytes)
2
4
Size (bytes) 1
2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
NB: The frame number is an identification number. It is used to check if the answer coming from the slave device corresponds to the PLC’s request. The list of values is available p. 31 to 35.
30
SOCOMEC - Réf. : 876 786 A GB
DIRIS A40/A41 - RS485 - PROFIBUS® DP USE OF THE PROFIBUS®-DP MODULES
MODULE 9: SPECIAL FRAME Name
Decimal address
Hexa. address
Phase 1 current (mA) Phase 2 current (mA) Phase 3 current (mA) Neutral current (mA) Phase to phase voltage U12 (V/10) Phase to phase voltage U23 (V/10) Phase to phase voltage U31 (V/10) Phase to neutral voltage phase 1 (V/10) Phase to neutral voltage phase 2 (V/10) Phase to neutral voltage phase 3 (V/10) Frequency (Hz/100) _ Active power (W) _ Reactive power (var) _ Apparent power (VA) _ Power factor L / C (0.001) Max. value I1 (mA) Max. value I2 (mA) Max. value I3 (mA) Maximum value active power + (W) Maximum value active power - (W) Maximum value reactive power + (var) Maximum value reactive power - (var) Maximum value apparent power (VA) Active energy + < 10000 (kWh) Active energy + > 10000 (kWh) Reactive energy + < 10000 (kvarh) Reactive energy + > 10000 (kvarh) Apparent energy < 10000 (kVAh) Apparent energy > 10000 (kVAh) Active power phase 1 (W) Active power phase 2 (W) Active power phase 3 (W) Reactive power phase 1 (var) Reactive power phase 2 (var) Reactive power phase 3 (var) Apparent power phase 1 (VA) Apparent power phase 2 (VA) Apparent power phase 3 (VA) Power factor phase 1 (0.001) Power factor phase 2 (0.001) Power factor phase 3 (0.001) Average value I1 (mA) Average value I2 (mA) Average value I3 (mA) Average value active power + (W) Average value active power - (W) Average value reactive power + (var) Average value reactive power - (var) Average value Apparent power (VA) Active energy - < 10000 Active energy - >10000
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
0000 0001 0002 0003 0004 0005 0006 0007 0008 0009 000A 000B 000C 000D 000E 000F 0010 0011 0012 0013 0014 0015 0016 0017 0018 0019 001A 001B 001C 001D 001E 001F 0020 0021 0022 0023 0024 0025 0026 0027 0028 0029 002A 002B 002C 002D 002E 002F 0030 0031 0032
SOCOMEC - Réf. : 876 786 A GB
GB
List of values
31
DIRIS A40/A41 - RS485 - PROFIBUS® DP
USE OF THE PROFIBUS®-DP MODULES
MODULE 9: SPECIAL FRAME List of values
32
Name
Decimal address
Hexa. address
Reactive energy - < 10000 Reactive energy - > 10000 Input pulse meter 1 < 10000 Input pulse meter 1 > 10000 Input pulse meter 2 < 10000 Input pulse meter 2 > 10000 Input pulse meter 3 < 10000 Input pulse meter 3 > 10000 Input pulse meter 4 < 10000 Input pulse meter 4 > 10000 Status inputs 1 2 3 4 Thd I1 Thd I2 Thd I3 Thd In Harmonic I1 row 3 Harmonic I2 row 3 Harmonic I3 row 3 Harmonic IN row 3 Harmonic I1 row 5 Harmonic I2 row 5 Harmonic I3 row 5 Harmonic IN row 5 Harmonic I1 row 7 Harmonic I2 row 7 Harmonic I3 row 7 Harmonic IN row 7 Harmonic I1 row 9 Harmonic I2 row 9 Harmonic I3 row 9 Harmonic IN row 9 Harmonic I1 row 11 Harmonic I2 row 11 Harmonic I3 row 11 Harmonic IN row 11 Harmonic I1 row 13 Harmonic I2 row 13 Harmonic I3 row 13 Harmonic IN row 13 Harmonic I1 row 15 Harmonic I2 row 15 Harmonic I3 row 15 Harmonic IN row 15 Thd U12 Thd U23 Thd U31 Harmonic U12 row 3 Harmonic U23 row 3 Harmonic U31 row 3 Harmonic U12 row 5 Harmonic U23 row 5
51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101
0033 0034 0035 0036 0037 0038 0039 003A 003B 003C 003D 003E 003F 0040 0041 0042 0043 0044 0045 0046 0047 0048 0049 004A 004B 004C 004D 004E 004F 0050 0051 0052 0053 0054 0055 0056 0057 0058 0059 005A 005B 005C 005D 005E 005F 0060 0061 0062 0063 0064 0065
SOCOMEC - Réf. : 876 786 A GB
DIRIS A40/A41 - RS485 - PROFIBUS® DP USE OF THE PROFIBUS®-DP MODULES
MODULE 9: SPECIAL FRAME Name
Decimal address
Hexa. address
Harmonic U31 row 5 Harmonic U12 row 7 Harmonic U23 row 7 Harmonic U31 row 7 Harmonic U12 row 9 Harmonic U23 row 9 Harmonic U31 row 9 Harmonic U12 row 11 Harmonic U23 row 11 Harmonic U31 row 11 Harmonic U12 row 13 Harmonic U23 row 13 Harmonic U31 row 13 Harmonic U12 row 15 Harmonic U23 row 15 Harmonic U31 row 15 Thd V1 Thd V2 Thd V3 Harmonic V1 row 3 Harmonic V2 row 3 Harmonic V3 row 3 Harmonic V1 row 5 Harmonic V2 row 5 Harmonic V3 row 5 Harmonic V1 row 7 Harmonic V2 row 7 Harmonic V3 row 7 Harmonic V1 row 9 Harmonic V2 row 9 Harmonic V3 row 9 Harmonic V1 row 11 Harmonic V2 row 11 Harmonic V3 row 11 Harmonic V1 row 13 Harmonic V2 row 13 Harmonic V3 row 13 Harmonic V1 row 15 Harmonic V2 row 15 Harmonic V3 row 15 I System U System V System Hour meter < 10000 Hour meter > 10000
102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146
0066 0067 0068 0069 006A 006B 006C 006D 006E 006F 0070 0071 0072 0073 0074 0075 0076 0077 0078 0079 007A 007B 007C 007D 007E 007F 0080 0081 0082 0083 0084 0085 0086 0087 0088 0089 008A 008B 008C 008D 008E 008F 0090 0091 0092
SOCOMEC - Réf. : 876 786 A GB
GB
List of values
33
DIRIS A40/A41 - RS485 - PROFIBUS® DP
USE OF THE PROFIBUS®-DP MODULES
MODULE 9: SPECIAL FRAME Name Last voltage dips Residual phase to phase involved: 0: none, 5: U12 6: U23 7: U31 Msb value (V/100) lsb value (V/100) Residual phase to neutral involved 0: none 22 : V1 23: V2 24: V3 Msb value (V/100) lsb value (V/100) Msb length (ms) lsb length (ms) Day Month Year Hour Minute Second Last power interruption Day Month Year Hour Minute Second Last average power Last P+ value (W) Last P- value (W) Last Q+ value (var) Last Q- value (var) Average frequency Last frequency value (Hz/100) Last swell Maximum phase to phase involved 0: none 5: U12 6: U23 7: U31 lsb value (V/100) Msb value (V/100) Maximum phase to neutral involved 0: none 22 : V1 23: V2 24: V3
34
Decimal address
Hexa. address
4096 4097 4098 4099
1000 1001 1002 1003
4100 4101 4102 4103 4104 4105 4106 4107 4108 4109
1004 1005 1006 1007 1008 1009 100A 100B 100C 100D
4110 4111 4112 4113 4114 4115
100E 100F 1010 1011 1012 1013
4116 4117 4118 4119
1014 1015 1016 1017
4120
1018
4121
1019
4122 4123 4124
101A 101B 101C
SOCOMEC - Réf. : 876 786 A GB
DIRIS A40/A41 - RS485 - PROFIBUS® DP USE OF THE PROFIBUS®-DP MODULES
Name lsb value (V/100) Msb value (V/100) Msb length (ms) lsb length (ms) Month Day Year Hour Minute Second Average voltage Last value U12 (V/10) Last value U23 (V/10) Last value U31 (V/10) Last value U1 (V/10) Last value U2 (V/10) Last value U3 (V/10) New values available Average In (mA) Average maximum In (mA)
Decimal address 4125 4126 4127 4128 4129 4130 4131 4132 4133 4134
Hexa. address 101D 101E 101F 1020 1021 1022 1023 1024 1025 1026
4135 4136 4137 4138 4139 4140
1027 1028 1029 102A 102B 102C
4141 4142
102D 102E
GB
MODULE 9: SPECIAL FRAME
Note: msb: most significant byte. lsb: least significant byte. Input frame Name Frame number Value 1 Value 2 Value 3 Value 4 Value 5 Value 6 Value 7 Value 8 Value 9 Value 10 Value 11 Value 12 Value 13 Value 14 Value 15 Value 16 Length: 33 bytes
SOCOMEC - Réf. : 876 786 A GB
Size (bytes) 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
35
DIRIS A40/A41 - RS485 - PROFIBUS® DP
USE OF THE PROFIBUS®-DP MODULES
MODULE 10 : RESERVED FOR MANUFACTURER
MODULE 11 : SIZE LIMITED SPECIAL FRAME This module allows the creation of a personalised module of 4 values. Output frame Name Frame number Address of value Address of value Address of value Address of value Length: 9 bytes
1 2 3 4
Size (bytes) 1 2 2 2 2
NB: The frame number is an identification number. It is used to check if the answer coming from the slave device corresponds to the PLC’s request. The list of values is available p. 31 to 35 (module 9).
Input frame Name Frame number Value 1 Value 2 Value 3 Value 4
Size (bytes) 1 2 2 2 2
Length: 9 bytes
36
SOCOMEC - Réf. : 876 786 A GB
DIRIS A40/A41 - RS485 - PROFIBUS® DP
DIAGNOSTICS
GB
These contain an indication of the presence of DIRIS A40/A41 option modules, the serial number, the DIRIS A40/A41 product code and the presence of an alarm or an excess.
Slot 2
Slot 3
Slot 4
DIRIS 475 A
Slot 1
Name Option present on slot 0: RS485 1: Metering 3: Harmonics F0: In 20: 2 In / 2 out 30: 2 0 / 4 - 20 mA 50: PROFIBUS®-DP Option present on slot 0: RS485 1: Metering 3: Harmonics F0: In 20: 2 In / 2 out 30: 2 0 / 4 - 20 mA 50: PROFIBUS®-DP Option present on slot 0: RS485 1: Metering 3: Harmonics F0: In 20: 2 In / 2 out 30: 2 0 / 4 - 20 mA 50: PROFIBUS®-DP Option present on slot 0: RS485 1: Metering 3: Harmonics F0: In 20: 2 In / 2 out 30: 2 0 / 4 - 20 mA 50: PROFIBUS®-DP
1
Size (bytes) 1
2
1
3
1
4
1
SOCOMEC - Réf. : 876 786 A GB
37
DIRIS A40/A41 - RS485 - PROFIBUS® DP
DIAGNOSTICS
Name Serial number Product code Alarms bit 0: Alarm I bit 1: Alarm In bit 2: Alarm U bit 3: Alarm V bit 4: Alarm P+ bit 5: Alarm Q+ bit 6: Alarm S bit 7: Alarm F bit 8: Alarm PFL bit 9: Alarm Time bit 10: Alarm Thd I bit 11: Alarm Thd In bit 12: Alarm Thd U bit 13: Alarm Thd V bit 14: Alarm Pbit 15: Alarm Qbit 16: Alarm PFC bit 17-31: not used Excesses bit 0: Excess I bit 1: Excess In bit 2: Excess U bit 3: Excess V bit 4: Excess P+ bit 5: Excess Q+ bit 6: Excess S bit 7: Excess F bit 8: Excess PFL bit 9: Excess Time bit 10: Excess Thd I bit 11: Excess Thd In bit 12: Excess Thd U bit 13: Excess Thd V bit 14: Excess Pbit 15: Excess Qbit 16: Excess PFC bit 17-31: not used Length: 17 bytes
38
Size (bytes) 4 1 4
4
SOCOMEC - Réf. : 876 786 A GB
DIRIS A40/A41 - RS485 - PROFIBUS® DP
TECHNICAL CHARACTERISTICS
COMMUNICATION
Certificate
2 or 3 wires half duplex PROFIBUS®-DP 9.6 to 1500 kbauds 4 kV UL 61010-1 CSA-C22.2 No. 61010-1 UL file No: E257746 CSA report No. for DIRIS A20: 1810571 CSA report No. for DIRIS A40: 1810577
GB
RS485 Protocol Speed Galvanic insulation UL-CSA Approval Standard
GLOSSARY OF ABBREVIATIONS COM ADR DIAG PARA
SOCOMEC - Réf. : 876 786 A GB
Communication Slave address Diagnostic function activated or not Remote parametering activated or not
39
DIRIS A40/A41 - RS485 - PROFIBUS® DP
TECHNICAL CHARACTERISTICS
40
SOCOMEC - Réf. : 876 786 A GB
DIRIS 345 B - DIRIS 468 A / QUAT NOT 3i
SOCOMEC - Ref.: 876 786 A GB - 08 / 07
HEAD OFFICE SOCOMEC GROUP S.A. SOCOMEC capital 11 014 300 € R.C.S. Strasbourg B 548 500 149 B.P. 60010 - 1, rue de Westhouse - F-67235 Benfeld Cedex - FRANCE
INTERNATIONAL SALES DEPAR TMENT SOCOMEC 1, rue de Westhouse - B.P. 60010 F - 67235 Benfeld Cedex - FRANCE Tel. +33 (0)3 88 57 41 41 - Fax +33 (0)3 88 74 08 00
[email protected]
www.socomec.com This document is not a contract. SOCOMEC reserves the right to modify features without prior notice in view of continued improvement.