Preview only show first 10 pages with watermark. For full document please download

Discontinued Product

   EMBED


Share

Transcript

INSTALLATION INSTRUCTIONS Lumascape Lighting Industries Pty Ltd 38-44 Enterprise Street, Cleveland, QLD 4163, Australia PO Box 1875, Cleveland D.C., QLD 4163, Australia T 07 3286 2299 F 07 3286 6599 E [email protected] W www.lumascape.com.au WALL MOUNT MODEL: LS931LED INPUT VOLTAGE: 24 V DC A.C.N. 0105 72 773 S DI LS931LED: Lineo (Single Colour) Warranty voided if not installed as per installation instructions DANGER ISOLATE LUMINAIRE FROM POWER Do not drill into the product. Failure to isolate power supply before installation or maintenance may result in fire, serious injury, electric shock, death and may damage the luminaire. 1. 22 mm NT CO Do not attempt to open, alter or modify the product. 29 mm 18 mm 11 mm Do not modify the supply cable. Failure to connect correctly may damage the product. Attach mounting strip to wall. 2. Attach mounting strip to wall. IN D UE In vertical installation ensure cable entry is at UC OD 3. the bottom. PR SINGLE COLOUR VERSION Connect to 24 V ripple free DC power supply trace wire is positive + plain wire is negative - T Power supply must be isolated prior to connection or disconnection of cables. Failure to do so will result in damage to the luminaire components. IN0066 - 31 May 2013 Observe polarity. Single Colour Versions Trace Wire Positive + ON SC DI Plain Wire Negative - RGB Versions Yellow Wire Positive Black Wire Blue LED Red Wire Red LED Green Wire Green LED • 24 V DC power supply. • Failure to connect correctly may damage the product. • Cable entry must be at the bottom. • Ensure the supply cable to the product is joined in a sealed enclosure mounted below the Lineo strip. N TI • All mounting must be installed using the suppleid strip and/or rails. • Ensure connections are fully weather-proof. • Ensure adequate drainage is provided around the product so it cannot lay in water. • Do not atttempt to open, alter or modify the product. • Do not drill into the product. • Failure to connect correcly may damage the product. Luminaires and transformers to be installed by licensed electrical contractors. Luminaires to be used for intended purpose only. Do not operate the luminaires with a missing or damaged parts. Use only genuine Lumascape parts to replace damaged or missing components. Refer to instructions for installation and operating requirements. Ensure installation complies with local regulations UC 1. 2. 3. 4. 5. 6. OD WARNING - To reduce the risk of FIRE or INJURY: PR SAFETY INSTRUCTIONS D UE • Do not modify the supply cable. Voltage insulation test (megger) will permanently damage product and will void warranty. www.lumascape.com.au T SAVE THESE INSTRUCTIONS. Copyright ©2013 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773 IN0066 - 31 May 2013