Preview only show first 10 pages with watermark. For full document please download

Distributed Power System

   EMBED


Share

Transcript

Distributed Power System Introduction Distributed Power System (DPS) is a new generation power solution, specialized for compact site. It consists of DC module, AC module & battery module. It supports pole-mounted and wall-mounted. DPS can be widely used for macro site, small cell and remote RRU. DPU30D : DC module, converts AC/HVDC to -48Vdc, supplies 3 branches of DC output and 1 branch for battery DPU30A : AC module, supplies constant 3 branches of AC output and a branch of DC output for battery unit or DC load DOU-DCD01 DPU30D DBU20B : battery module, provides reliable power backup DBU20B DOU-DCD01: DC distribution unit Features DC Load Scenarios  Simple Deployment • Fast installation, 10mins by 1 people, flexible deployment • Multiple input mode: AC/HVDC (DPU30D)  Easy O&M AC Load • Mobile APP (based on Bluetooth), NetEco • Fan-free design, 3-5 years routine maintenance free DPU30A  Reliable Power Supply DBU20B • Iron lithium battery, IP65, working temperature -40℃ to +55℃ Scenarios  RRU/AAU remote site  Easy Macro Site  LampSite  AtomCell (hot-spot / blind-spot coverage) AC Load Scenarios Specifications DPS Solution for DC Load Scenarios Product Type Load Output 400 mm × 300 mm × 120 mm 400 mm × 300 mm × 50 mm Weight 7 kg 20 kg 18kg 6 kg 1000 W / 20 Ah NA −40℃ to +55℃ IF up to 45℃, solar protection devices are needed −40℃ to +55℃ Class C Class D Wall-mounted, pole-mounted, tower installation 1500 W 2000 W / 20 Ah Bottom inlet and outlet Protection Level IP65 Working Temperature −40℃ to +55℃ Cooling Mode Natural heat dissipation Application Environment Class D Storage Temperature −40℃ to +70℃ Operating Humidity 5% to 95% (non-condensing) Altitude −60 to +4000 m (1℃ per 200m temperature derating from 2000-4000m) NA Power Input Mode 220 Vac single-phase, 110 Vac dual-live wire, HVDC -48 Vdc -48 Vdc -48 Vdc Input Voltage AC: 85 - 300 Vac HVDC: 85 - 400 Vdc -48 Vdc -48 Vdc -48 Vdc Input Frequency 45 Hz - 65 Hz NA NA NA AC Input 1×220 V/15 A NA NA NA AC SPD Difference mode: 20 KA , Common mode: 20 KA NA NA NA Output Power 1500 W 2000W 1000W NA Output Voltage 48 Vdc -48 Vdc -48 Vdc 48 Vdc DC Output 3×30 A (with exchangeable fuse ) NA NA 5×30 A (with exchangeable fuse ) Battery Branch 1×40 A (with exchangeable fuse ) 2×40 A (with exchangeable fuse ) 2×30 A (with exchangeable fuse ) 2×40 A (with exchangeable fuse ) DC SPD Difference mode: 10 KA , Common mode: 20 KA Difference mode: 10 KA , Common mode: 20 KA Difference mode: 10 KA , Common mode: 20 KA NA ≥96% NA NA NA 1× DB9 ( CAN) 1× DB15 ( CAN+ 4× DO+ RS485*) 2× RJ45 ( CAN) 2× DB9 ( CAN) NA Efficiency Communic ation Interface DOU-DCD01 400 mm × 300 mm × 120 mm Cabling Mode Power Input DBU20B-N12A1 400 mm × 300 mm × 50 mm Rated Power Environme nt DBU20B-N12A2 Dimension (H×W×D) Installation Mode System DPU30D-N06A1 Interface Definition Class D *Remark: RS485 interface supports telecom protocol / NetEco / U2000/M2000 Specifications DPS Solution for AC Load Scenarios Product Type DPU30A-N06A1 DBU20B-N12A2 DBU20B-N12A1 Dimension (H×W×D) 400 mm × 300 mm × 50 mm 400 mm × 300 mm × 120 mm 400 mm × 300 mm × 120 mm Weight 7 kg 20 kg 18 kg Installation Mode Rated Power Cabling Mode Wall-mounted, pole-mounted, tower installation 1500 W 2000 W / 20 Ah 1000 W / 20 Ah Bottom inlet and outlet System Environment Power Input Load Output Protection Level IP65 Working Temperature −40℃ to +55℃ Cooling Mode Natural heat dissipation Application Environment Class D Storage Temperature −40℃ to +70℃ Operating Humidity 5% to 95% (non-condensing) Altitude −60 to +4000 m (1℃ per 200m temperature derating from 2000-4000m) Power Input Mode 20 Vac single-phase, 110 Vac dual-live wire -48 Vdc -48 Vdc Input Voltage AC: 85 to 300 Vac -48 Vdc -48 Vdc Input Frequency 45 Hz - 65 Hz NA NA AC Input 1×220 V/15 A NA NA AC Input SPD Difference mode: 20 KA , Common mode: 20 KA NA NA Output Power 1500 W 2000 W 1000 W Output Voltage 220 Vac -48 Vdc -48 Vdc AC Output SPD Difference mode: 20 KA , Common mode: 20 KA NA NA AC Output 3×16 A NA NA Battery Branch 1×40 A (with exchangeable fuse ) 2×40 A (with exchangeable fuse ) 2×30 A (with exchangeable fuse ) DC SPD Difference mode: 3 KA , Common mode: 5 KA Difference mode: 10 KA , Common mode: 20 KA Difference mode: 10 KA , Common mode: 20 KA ≥98% Bypass NA NA 1× DB9 ( CAN) 1× DB15 ( CAN+ 4× DO+ RS485*) 2× RJ45( CAN) 2× DB9( CAN) Efficiency Communicati on Interface Interface Definition −40℃ to +55℃ IF up to 45℃, solar protection devices are needed Class D Class C *Remark: RS485 interface supports telecom protocol / NetEco / U2000/M2000 Copyright © Huawei Technologies Co., Ltd. 2016. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. General Disclaimer The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice. HUAWEI TECHNOLOGIES CO., LTD. Huawei Industrial Base Bantian Longgang Shenzhen 518129, P.R. China Tel: +86-755-28780808 www.huawei.com