Transcript
Size: 9V Lithium Manganese Dioxide Battery Specifications
17.55 mm 15.5
Classification: Chemical System: Designation: Nominal Voltage: Operating Voltage: Operating Temp: Storage Temp: Typical Weight: Typical Volume: Typical Impedance: Typical IR Content: Safety Features:
12.95 mm 12.45 26.5 mm 24.5
(-)
(+) 46.4 mm MAX
48.5 mm 46.5
Dimensions shown are ANSI standards
Lithium 9V Lithium Manganese Dioxide ANSI-1604LC 9V 9.6V-4.8V -40°C to 60°C (-40°F to 140°F) 5°C to 30°C (41°F to 86°F) RH 40%-80% 34 g 22.8 cubic centimeters ( 1.4 cubic inch) 775mΩ @ 20kHz 1.35 g (0.048 oz.)
Freshness Guarantee: Transportation: Global (except US) United States
Positive Temperature Coefficient Switch (PTC) Burst proof venting holes Up to 10 years at 20°C For complete details, please see reference: Special Provision A45 of the International Air Transport Association Dangerous Goods Regualations 49 CFR 173.185
Battery Life Comparison 50 mA, continous Discharge to 5.4V at 23°C
Typical Discharge at Temperature 510 Ohm 4h/d 10.2
10.2 Carbon-zinc
20°C -10°C
Alkaline
9.0 Voltage (V)
Voltage (V)
9.0 7.8 6.6 5.4
LiMnO2
DL1604
Lithium
7.8
6.6
0
10
20
30
40
50
60
70
80
Service (hours)
5.4 0
2
4
6
8
10
12
14
Service (hours)
BATTERIES Berkshire Corporate Park Bethel, CT 06801 U.S.A. Telephone: Toll free 1.800.544.5454 Internet: www.duracell.com *Delivered capacity is dependent on the applied load, intermittent usage, operating temperature and cut off voltage. Please refer to the charts and discharge data for examples of energy/service life that the battery will provide for various conditions. Information and contents in this data sheet are for reference purposes only. They do not constitute any warranty and representation is subject to change without notice. For most current information and further details, please contact Duracell. Page 1 of 1
REV LI 11
16