Preview only show first 10 pages with watermark. For full document please download

Dm80vc / Dd80vc Two-stage Variable Speed Gas Furnace 80% Afue

   EMBED


Share

Transcript

DM80VC / DD80VC Two-Stage Variable Speed Gas Furnace 80% AFUE Heating Input: 60,000–100,000 BTU/h ■ Contents Nomenclature.............................................2 Product Specifications.................................3 Dimensions..................................................4 Airflow Data.................................................6 Wiring Diagram .........................................11 Accessories................................................12 ■ Standard Features • • • • • • • • • • • • • ComfortNet™ Communicating Systems compatible Heavy-duty stainless-steel dual-diameter, tubular heat exchanger Two-stage gas valve provides quiet, economical heating Durable Silicon Nitride igniter Quiet two-speed draft inducer Utilizes ComfortNet™ communicating, two-stage or single-stage thermostats Self-diagnostic control board with constant memory fault code history output to a dual 7-segment display Color-coded low-voltage terminals with provisions for electronic air cleaner and humidifier Efficient and quiet variable-speed airflow system gently ramps up or down according to heating or cooling demand Multiple continuous fan speed options offer quiet air circulation Auto-Comfort and enhanced dehumidification modes available California Low NOx emissions-compliant models available AHRI Certified; ETL Listed ■ Cabinet Features • Multi-position installation: DM80VC: Upflow, horizontal left or right. DD80VC: Dedicated downflow • Convenient left or right connection for gas and electrical service • Cabinet air leakage (QLeak) ≤ 2% • Heavy-gauge steel cabinet with durable baked-enamel finish • Fully insulated heat exchanger and blower section * Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), the 12-Year Unit Replacement Limited Warranty and the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Additional requirements for annual maintenance are required for the Unit Replacement Limited Warranty. Online registration and some of the additional requirements are not required in California or Quebec. SS-DM80VC www.daikincomfort.com 9/15 Supersedes 6/15 Nomenclature D 1 M 2 80 3,4 V 5 C 6 060 7,8,9 3 10 Brand D  -­‐  Daikin  Brand Gas  Valve M  -­‐  Modulating V  -­‐  Two  Stage   2 A 13 A 14 Major  Revision      A  -­‐  Initial  Release      B  -­‐  1st  Revision NOx      N  -­‐Natural  Gas      X  -­‐  Low  NOx 92  -­‐  92%  AFUE 80  -­‐  80%  AFUE Cabinet  Width A  -­‐  14"                C  -­‐  21" B  -­‐  17½"        D  -­‐  24½" H  -­‐  Convertible  Two-­‐Stage S  -­‐  Single  Stage Motor C  -­‐  Variable  Speed  ECM  /  ComfortNet E  -­‐High  Efficiency S  -­‐  Single  Speed MBTU/h 040  -­‐  40,000  BTU/h 060  -­‐  60,000  BTU/h 080  -­‐  80,000  BTU/h X 12 Minor  Revision      A  -­‐  Initial  Release      B  -­‐  1st  Revision Configuration M  -­‐  Upflow/Horizontal C  -­‐  Downflow/Horizontal D  -­‐  Dedicated  Downflow AFUE 97  –  97-­‐98%  AFUE 96  –  96%  AFUE A 11 Maximum  CFM      2  -­‐      800  CFM      3  -­‐  1200  CFM      4  -­‐  1600  CFM      5  -­‐  2000  CFM 100  -­‐  100,000  BTU/h 120  -­‐  120,000  BTU/h 140  -­‐  420,000  BTU/h www.daikincomfort.com SS-DM80VC Product Specifications DM80VC 0604B*A DM80VC 0805C*A DM80VC 1005C*A DD80VC 0603B*A DD80VC 0805C*A DD80VC 1005C*A 60,000 80,000 100,000 60,000 80,000 100,000 Natural Gas 48,000 64,000 80,000 48,000 64,000 80,000 LP Gas 48,000 64,000 80,000 48,000 64,000 80,000 42,000 56,000 70,000 42,000 56,000 70,000 Heating Capacity High Fire Input (BTU/h)¹ High Fire Output (BTU/h)¹ (below) Low Fire Input (BTU/h)¹ Low Fire Output (BTU/h)1 (below) Natural Gas 33,600 44,800 56,000 33,600 44,800 56,000 LP Gas 33,600 44,800 56,000 33,600 44,800 56,000 80 80 80 80 80 80 Available AC @ 0.5” ESP 1.5 - 4.0 2.0 - 5.0 2.0 - 5.0 1.5 - 3.0 2.0 - 5.0 2.0 - 5.0 Temperature Rise Range (° F) 20 - 50 20 - 50 25 - 55 30-60 35 - 65 35-65 10” x 8” 10” x 10” 10” x 10” 10” x 8” 10” x 10” 10” x 10” ¾ ¾ ¾ ¾ ¾ ¾ AFUE 2 Circulator Blower Size (D x W) Horsepower - RPM Speed Variable Variable Variable Variable Variable Variable Vent Diameter 3 4” 4” 4” 4” 4” 4” No. of Burners 3 4 5 3 4 5 12.1 12.1 12.1 12.1 12.1 12.1 Electrical Data Min. Circuit Ampacity 4 Max. Overcurrent Device (amps) 5 15 15 15 15 15 15 Ship Weight (lbs) 107 121 124 105 125 129 ¹ ² ³ ⁴ Natural Gas BTU/h; for altitudes above from 0’ to 4,500’ above sea level, reduce input rating 4% for each 1,000’ above 4,500’ altitude. Low-fire rate is 70% of high-fire rate. DOE AFUE based upon Isolated Combustion System (ICS) Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. Notes • All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. • Gas Service Connection ½” FPT • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. SS-DM80VC www.daikincomfort.com 3 DM80VC Dimensions PRODUCT DIMENSIONS Alt. Alt. Gas GasInlet Inlet 19½˝ ➛ AMVC8/GMVC8_____X* 1¾˝ 1⁷/₁₆˝ ➛ 33³/₈˝ 20˝ 19½˝ ➛ Alt. Alt. Gas Gas Inlet Inlet 27⁷/₈˝ High-Voltage High Voltage Inlet Inlet ➛ 23⁵/₁₆˝ Alt. High Voltage Voltage 13¼˝ Low Voltage Low-Voltage Inlet Alt. LowVoltage Low Voltage 23¾˝ 28˝ Dimensions Model W D Widths H A B 17½” 16” DM80VC0604B*A 17½” 28” 39” DM80VC0805C*A 21” 28” 39” 21” 19½” DM80VC1005C*A 21” 28” 39” 21” 19½” MODELS AMVC80704BX** GMVC80704BX** AMVC80905CX** AMVC81155CX** GMVC80905CX** Minimum Clearances to Combustible Materials GMVC81155CX** Sides Rear Front ¹ 1 0 3 A B 17-1/2 16 21 19-1/2 Vent ² are in inches. All dimensions SW B 6 1 Top 1 Approved for line contact in the horizontal position. ¹ 24” clearance for serviceability recommended. ² Single Wall Vent (SW) to be used only as a connector. Refer to the venting tables outlined in the Installation Manual for additional venting requirements. 8 4 www.daikincomfort.com SS-DM80VC DD80VC Dimensions A 28” 19⅝” B High-Voltage Electrical Low-Voltage Electrical 33⅜” Gas Inlet 18⅜” 11⅜” Dimensions Model W D Widths H A B 16” DD80VC0603B*A 17½” 28” 39” 17½” DD80VC0805C*A 21” 28” 39” 21” 19½” DD80VC1005C*A 21” 28” 39” 21” 19½” Minimum Clearances to Combustible Materials Sides Rear Front ¹ 1 0 3 Vent ² SW B 6 1 Top 1 Approved for line contact in the horizontal position. ¹ 24” clearance for serviceability recommended. ² Single Wall Vent (SW) to be used only as a connector. Refer to the venting tables outlined in the Installation Manual for additional venting requirements. SS-DM80VC www.daikincomfort.com 5 DM80VC Airflow Data DM80VC0604B*A Cooling Speeds (@ .1" - .8" w.c. ESP) Tap A B C D Adjust High-Stage CFM DM80VC0604B*A Heating Speeds (@ .1" - .5" w.c. ESP; Rise Range: 20° - 50°F) Low-Stage CFM Tap A B C D High-Stage CFM Low-Stage CFM Rise (°F) Minus 10% 540 351 Minus 10% 1,125 788 46 Minus 5% 570 371 Minus 5% 1,188 831 43 Normal 600 390 Normal 1250 875 41 Plus 5% 630 410 Plus 5% 1,313 919 39 Plus 10% 660 429 Plus 10% 1,375 963 38 Minus 10% 720 468 Minus 10% 1,215 851 43 Minus 5% 760 494 Minus 5% 1,283 898 40 A Normal 800 520 Normal 1,350 945 38 Plus 5% 840 546 B Plus 5% 1,418 992 36 Plus 10% 880 572 Plus 10% 1,485 1,040 35 Minus 10% 990 644 Minus 10% 1,305 914 40 Minus 5% 1,045 679 Minus 5% 1,378 964 38 Normal 1,100 715 Normal 1,450 1,015 36 Plus 5% 1,155 751 Plus 5% 1,523 1,066 34 Plus 10% 1,210 787 Plus 10% 1,595 1,117 33 Minus 10% 1,260 819 Minus 10% 1,395 977 37 Minus 5% 1,330 865 Minus 5% 1,473 1,031 35 33 C Normal 1,400 910 Normal 1,550 1,085 Plus 5% 1,470 956 Plus 5% 1,628 1,139 31 Plus 10% 1,540 1,001 Plus 10% 1,705 1,194 30 D DM80VC0805C*A Cooling Speeds (@ .1" - .8" w.c. ESP) Tap Adjust DM80VC0805C*A Heating Speeds (@ .1" - .5" w.c. ESP; Rise Range: 20° - 50°F) Adjust High-Stage CFM Low-Stage CFM Minus 10% 720 468 Minus 5% 760 494 Normal 800 520 Plus 5% 840 Plus 10% 880 Tap Adjust High-Stage CFM Low-Stage CFM Rise (°F) Minus 10% 1,350 945 49 Minus 5% 1,425 998 46 Normal 1,500 1,050 44 546 Plus 5% 1,575 1,103 42 572 Plus 10% 1,650 1,155 40 A Minus 10% 990 644 Minus 10% 1,440 1,008 46 Minus 5% 1,045 679 Minus 5% 1,520 1,064 44 Normal 1,100 715 Plus 5% 1,155 751 B Normal 1,600 1,120 42 Plus 5% 1,680 1,176 40 Plus 10% 1,210 787 Plus 10% 1,760 1,232 38 Minus 10% 1,260 819 Minus 10% 1,530 1,071 44 Minus 5% 1,330 865 Normal 1,400 910 Plus 5% 1,470 956 C Minus 5% 1,615 1,131 41 Normal 1,700 1,190 39 Plus 5% 1,785 1,250 37 36 Plus 10% 1,540 1,001 Plus 10% 1,870 1,309 Minus 10% 1,620 1,053 Minus 10% 1,620 1,134 41 Minus 5% 1,710 1,112 Minus 5% 1,710 1,197 39 Normal 1,800 1,170 Normal 1,800 1,260 37 Plus 5% 1,890 1,229 Plus 5% 1,890 1,323 35 Plus 10% 1,980 1,287 Plus 10% 1,980 1,386 34 D See Notes on following page. 6 www.daikincomfort.com SS-DM80VC DM80VC Airflow Data (cont.) DM80VC1005C*A Cooling Speeds (@ .1" - .8" w.c. ESP) DM80VC1005C*A Heating Speeds (@ .1" - .5" w.c. ESP; Rise Range: 25° - 55°F) Tap Adjust High-Stage CFM Low-Stage CFM A Minus 10% Minus 5% Normal Plus 5% Plus 10% 720 760 800 840 880 468 494 520 546 572 B Minus 10% Minus 5% Normal Plus 5% Plus 10% 990 1,045 1,100 1,155 1,210 644 679 715 751 787 C Minus 10% Minus 5% Normal Plus 5% Plus 10% 1,260 1,330 1,400 1,470 1,540 819 865 910 956 1,001 D Minus 10% Minus 5% Normal Plus 5% Plus 10% 1,620 1,710 1,800 1,890 1,980 1,053 1,112 1,170 1,229 1,287 Tap Adjust High-Stage CFM Low-Stage CFM Rise (°F) A Minus 10% Minus 5% Normal Plus 5% Plus 10% 1,553 1,639 1,725 1,811 1,898 1,089 1,150 1,210 1,271 1,331 55 52 49 47 45 B Minus 10% Minus 5% Normal Plus 5% Plus 10% 1,575 1,663 1,750 1,838 1,925 1,103 1,164 1,225 1,286 1,348 54 51 49 46 44 C Minus 10% Minus 5% Normal Plus 5% Plus 10% 1,598 1,686 1,775 1,864 1,953 1,121 1,183 1,245 1,307 1,370 53 50 48 46 44 D Minus 10% Minus 5% Normal Plus 5% Plus 10% 1,620 1,710 1,800 1,890 1,980 1,134 1,197 1,260 1,323 1,386 53 50 47 45 43 Notes • These charts are for furnaces installed at 0’ - 4,500’. At higher altitudes, a properly de-rated unit will have the same temperature rise at a particular CFM, while the ESP at that CFM will be lower. • The installation must be adjusted to obtain a temperature rise within the range listed on the furnace nameplate. • Do not operate above .5” w.c. ESP in heating mode. • Propane gas installations will have a high-stage rise approximately 4°F lower than shown in the tables. Minimum Filter Sizes Model # Filter Size (in²) DM80VC0604B* DM80VC0805C* DM80VC1005C* (1) 16 x 25 (Side or Bottom) (1) 16 x 25 (Side or Bottom) ¹ (2) 16 x 25 (Side) or (1) 20 x 25 (Bottom) Note: Other size filters of equal or greater surface area may be used; filters may also be centrally located. ¹ Use 2 - 16 X 25 filters on side returns or 20 X 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity. SS-DM80VC www.daikincomfort.com 7 DD80VC Airflow Data DD80VC0603B*A Cooling Speeds (@ .1" - .8" w.c. ESP) Tap A B C D Adjust High-Stage CFM DD80VC0603B*A Heating Speeds (@ .1" - .5" w.c. ESP; Rise Range: 30° - 60°F) Low-Stage CFM Tap A B C D High-Stage CFM Low-Stage CFM Rise (°F) Minus 10% 540 351 Minus 10% 945 660 55 Minus 5% 570 371 Minus 5% 998 698 52 Normal 600 390 Normal 1,050 735 49 Plus 5% 627 408 Plus 5% 1,097 770 47 Plus 10% 660 429 Plus 10% 1,155 810 45 Minus 10% 720 468 Minus 10% 1,035 725 50 Minus 5% 760 494 Minus 5% 1,093 765 47 Normal 800 520 Normal 1,150 805 45 43 A B Plus 5% 836 543 Plus 5% 1,202 841 Plus 10% 880 572 Plus 10% 1,265 885 41 Minus 10% 900 585 Minus 10% 1,125 790 46 43 Minus 5% 950 618 Normal 1,000 650 Plus 5% 1,045 679 C Minus 5% 1,188 831 Normal 1,250 875 41 Plus 5% 1,306 912 39 Plus 10% 1,100 715 Plus 10% 1,375 960 38 Minus 10% 1,080 702 Minus 10% 1,215 850 43 Minus 5% 1,140 741 Minus 5% 1,283 898 40 Normal 1,200 780 Normal 1,350 945 38 Plus 5% 1,254 815 Plus 5% 1,411 988 36 Plus 10% 1,320 858 Plus 10% 1,485 1,040 35 D DD80VC0805C*A Cooling Speeds (@ .1" - .8" w.c. ESP) Tap Adjust DD80VC0805C*A Heating Speeds (@ .1" - .5" w.c. ESP; Rise Range: 35° - 65°F) Adjust High-Stage CFM Low-Stage CFM Minus 10% 720 468 Minus 5% 760 494 Normal 800 520 Plus 5% 836 543 Plus 5% 1,411 988 47 Plus 10% 880 572 Plus 10% 1,485 1,040 45 Tap A High-Stage CFM Low-Stage CFM Rise (°F) Minus 10% 1,215 850 55 Minus 5% 1,283 898 52 Normal 1,350 945 49 Adjust Minus 10% 990 644 Minus 10% 1,305 915 51 Minus 5% 1,045 679 Minus 5% 1,378 964 48 Normal 1,100 715 Plus 5% 1,150 748 B Normal 1,450 1,015 46 Plus 5% 1,515 1,059 44 Plus 10% 1,210 787 Plus 10% 1,595 1,115 42 Minus 10% 1,260 819 Minus 10% 1,395 975 48 Minus 5% 1,330 865 Normal 1,400 910 C Minus 5% 1,473 1,031 45 Normal 1,550 1,085 43 Plus 5% 1,463 951 Plus 5% 1,620 1,135 41 Plus 10% 1,540 1,001 Plus 10% 1,705 1,195 39 Minus 10% 1,620 1,053 Minus 10% 1,485 1,040 45 Minus 5% 1,710 1,112 Minus 5% 1,568 1,097 42 Normal 1,800 1,170 Normal 1,650 1,155 40 Plus 5% 1,881 1,223 Plus 5% 1,724 1,207 38 Plus 10% 1,980 1,287 Plus 10% 1,815 1,270 37 D See Notes on following page. 8 www.daikincomfort.com SS-DM80VC DD80VC Airflow Data (cont.) DD80VC1005C*A Cooling Speeds (@ .1" - .8" w.c. ESP) Tap A B C D DD80VC1005C*A Heating Speeds (@ .1” - .5” w.c. ESP; Rise Range: 35° - 65°F) Adjust High-Stage CFM Low-Stage CFM Minus 10% 765 497 Minus 10% 1,395 975 61 Minus 5% 808 525 Minus 5% 1,473 1,031 58 Normal 850 553 Plus 5% 888 578 Plus 10% 935 Minus 10% 1,035 Tap Adjust High-Stage CFM Low-Stage CFM Rise (°F) Normal 1,550 1,085 55 Plus 5% 1,620 1,135 52 608 Plus 10% 1,705 1,195 50 673 Minus 10% 1,485 1,040 57 Minus 5% 1,568 1,188 54 Normal 1,650 1,155 52 A Minus 5% 1,093 711 Normal 1,150 748 Plus 5% 1,202 781 Plus 5% 1,188 1,188 49 Plus 10% 1,265 822 Plus 10% 1,815 1,270 47 Minus 10% 1,305 848 Minus 10% 1,575 1,105 54 Minus 5% 1,378 896 Minus 5% 1,188 1,188 51 B Normal 1,450 943 Normal 1,750 1,225 49 Plus 5% 1,515 985 Plus 5% 1,188 1,188 46 Plus 10% 1,595 1,037 Plus 10% 1,925 1,350 44 C Minus 10% 1,665 1,082 Minus 10% 1,620 1,135 53 Minus 5% 1,758 1,143 Minus 5% 1,188 1,188 50 Normal 1,850 1,203 Normal 1,800 1,260 47 Plus 5% 1,900 1,257 Plus 5% 1,188 1,188 45 Plus 10% 2000 1,323 Plus 10% 1,980 1,385 43 D Notes • These charts are for furnaces installed at 0’ - 4,500’. At higher altitudes, a properly de-rated unit will have the same temperature rise at a particular CFM, while the ESP at that CFM will be lower. • The installation must be adjusted to obtain a temperature rise within the range listed on the furnace nameplate. • Do not operate above .5” w.c. ESP in heating mode. • Propane gas installations will have a high-stage rise approximately 4°F lower than shown in the tables. Minimum Filter Sizes Model # Filter Size (in²) DD80VC0603B* DD80VC0805C* (2) 10 x 20 or (1) 16 x 25 (Top Return) DD80VC1005C* (2) 14 x 20 or (1) 20 x 25 (Top Return) Note: Other size filters of equal or greater surface area may be used; filters may also be centrally located. ¹ Use 2 - 16 X 25 filters on side returns or 20 X 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity. SS-DM80VC www.daikincomfort.com 9 10 www.daikincomfort.com 10 20 30 40 50 60 70 30 80 90 100 40 50 60 700 600 CFM 90 100 2000 2200 2400 CFM 1800 1600 1400 OUTPUT BTU/HR x 1000 Output BTU/h x 1,000 80 1200 1100 1000 900 70 800 Formulas FORMULAS 110 120 130 CFM x 1.08 140 BTUBTU/h OUTPUT 1.08 x RISE Output== CFM CFM xx1.08 x Rise BTU OUTPUT RISE = = BTU/H Output ÷ CFM Rise 1.08 BTUBTU OUTPUT TEMPERATURE RISEChart CHART OutputvsVs. Temperature Rise 150 Temperature Rise Range Chart SS-DM80VC TEMPERATURE RISE Temperature Rise Wiring Diagram JUNCTION BOX WH DISCONNECT TO 115VAC/ 1 Ø /60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE WH BR RD PU OR PU PU 2 1 5 BK 4 3 SEE N OTE 6 HUMID IF IER HUM-OUT EAC OR BK EAC YL RD RD 10 11 12 7 8 9 4 5 6 1 2 3 CONT FAN HEAT OFF DLY T-STAT SEE NOTE 5 BK 24 VAC 115 VAC 40 VA TRANSFORMER DIAGNOSTIC LED' S HOT SURFACE IGN IT ER FLAME S ENSOR 115 V AC O Y1 Y2 W2 G C W1 2 R 1 WH 2 3 4 GR PK BK CIRCULATOR BLOWER INDUCTOR CO IL AUTO RESET PRIMARY LIMIT CONTR OL W1 LOW FIRE PRESS. SWITCH 24V HUM. PS1 (2) C NO W2 Y2 TO MICRO PS2 ( 12) NO C HIGH FIRE PRESS. S WTICH MANUAL RESET ROLLOU T LIMIT CONTR OLS HL I ( 1) MVL (13) PM MVH ( 14) C HI MVC ( 8) C GND ( 5) BK BK BLOW ER COMPARTMENT DOOR SW ITCH (OPEN WHEN DOOR OPEN) GND TR (11) TO R WH GND 24V HUM. GY BK 24 VAC AUTO RESET AUXILIARY LIMIT CONTR OLS PSO (7) O WH 1 Y1 24 V THERMOSTAT CONNECTIONS 5 4 3 2 1 TH (4) HLO ( 10) DEHUM BL BK TO +VDC NEUTRAL 40 V A TRANSFORMER G DEHUM PU YL FUSE DEHUM ENABLE TRIM ENABLE 1 24V THERMOSTAT CONNECTIONS YL 15 R RD TWO- STAGE INTEGRATED CONTROL MODULE RD DIP SWITCHES BR 14 FUSE 3 A BL 3 NEUTRAL IND LO IGN FS 2 NEUTRAL ID BLW R 2 4 CIRCUIT MOTOR CONNECTOR GN BL BL WH COOL PRFL HEAT AF 13 24 V 3A ECM MTR RD HARNESS TRIM % NEUTRAL ELECTRONIC AIR CLEANER IND HI 1 4 NEUTRAL HUMID IF IER HUM L INE COOL A F GND NEUTRAL GND ( 4) + VDC (1) INDOOR AIR CIRCULATOR BLWR RX (2) TO MICRO TX (3) AUX INTEGRATED CON TROL M ODULE HUMIDIF IER NOTES: 1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. 2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. 3. I F ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 $ C. USE COPPER CONDUCTORS ONLY. 4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. 5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH F OR MORE THAN 2 SECONDS WHILE IN STANDBY (NO THERMOSTAT INPUTS) 6. HUMIDIFIER INSTALLATION OPTIONS: USE HUM TERMINAL TO RUN HUMIDIFIER DURING HEAT CALL (COMMUNICATING OR LEGACY MODES). USE HUM-IN AND HUM-OUT TERMINALS TO RUN HUMIDIFIER DURING HEAT CALL ( COMMUNICATING MODE OR LEGACY MODE) OR INDEPENDENTLY FROM HEAT CALL (COMMUNICATING MODE ONLY - SETUP I S DONE WITHIN COMMUNICATING THERMOSTAT) COLOR CODES: PK PINK BR BROWN WH WHITE BL BLUE GY GRAY RD RED YL YELLOW OR ORANGE PU PURPLE GN GREEN BK BLACK INTEGRATED CONTROL MODULE 5 CIRCUIT CONNECTOR HUM HUMIN HUMOUT FS LINE INTEGRATED CONTROL MODULE BK RD WH AUTO RESET AUXIL IARY LIMIT CONTROL NEUTRAL INDOOR AIR CIRCULATOR BLW R HUM-IN L INE PU BLOWER COMPARTMENT DIS CONNECT JUNCT ION BOX INDUCTOR COIL 70kBTU ,9 0kBTU, 115kBTU MODELS ONLY GND BURNER COMPARTMENT N DOOR SW ITCH GN INDUCED DRAFT BLOWER WH RD BK 3 CHASSIS GROUND AUTO RESET PRIMARY LIMIT CONTROL MANUAL RESET ROLLOUT LIMIT CONTROLS GND L ⚡ BL WARNING: DISCONNECT POWER BEFORE SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. YL LOW VOLTAGE (24V) LOW VOLTAGE FIELD HI VOLTAGE (115V) HI VOLTAGE FIELD JUNCTION TERMINAL INTERNAL TO INTEGRATED CONTROL PLUG CONNECTION ⚠ Warning FLAME SENSOR EQUIPMENT GND FIELD GND GAS VALVE Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. WH PM 1 WH BK 3 WARNING:DISCONNECT POWER BEFORE SERVICING. W IRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. N NO HIGH FIRE PRESSURE SWITCH GAS VALVE (HONEY WELL) 2 L BK C NO TWO STAGE C YL C BL YL SWITCH 2 CIRCUIT CONNECTOR HI 24V HUM. YL 1 2 LOW FIRE PRESSURE BR SWITCH ASSEMBLY HOT SURFACE IGNITER YL RD ID BLOWER TWO-STAGE PRESSURE TO 115 VAC/ 1 Ø /60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE GND FIELD SPLICE SWITCH (TEMP.) IGNITER SWITCH (PRESS.) OVERCURRENT PROT. DEVICE 0140F01168-B SS-DM80VC www.daikincomfort.com 11 Accessories Model Description LPM-06 LP Conversion Kit (Springs & Orifice) ¹ AFE18-60A Fossil Fuel Kit (must be used in a dual-fuel application with a compatible thermostat) ASAS Electronic Air Cleaners (sizes = -10, -11, -12 or -18) AMU Media Air Cleaners (sizes = 1620, 2020, 1625 or 2025) ¹ White-Rodgers and Honeywell valves Our continuing commitment to quality products may mean a change in specifications without notice. © 2015 • Houston, Texas • Printed in the USA. 12 www.daikincomfort.com SS-DM80VC