Dm96hs / Dc96hs - Daikin Comfort

   EMBED


Share

Transcript

DM96HS / DC96HS Hybrid Two-Stage Multi-Speed Gas Furnace Up to 96% AFUE Heating Input: 40,000–120,000 BTU/h ■ Contents Nomenclature.......................................... 2 Product Specifications............................. 3 Dimensions.............................................. 5 Airflow Specifications.............................. 7 Wiring Diagram...................................... 10 Accessories............................................ 11 ■ Standard Features • • • • • • Heavy-duty stainless-steel tubular heat exchanger Stainless-steel secondary heat exchanger Two-stage gas valve Durable Silicon Nitride igniter Quiet single-speed induced draft blower Self-diagnostic control board with constant memory fault code history output to a LED • All models comply with California 40 ng/J Low NOx emissions standard • AHRI Certified; ETL Listed ■ Cabinet Features • Designed for multi-position installation — DM96HS: upflow, horizontal left or right DC96HS: downflow, horizontal left or right • Certified for direct vent (2-pipe) or non-direct vent (1-pipe) • Easy-to-install top venting with optional side venting • Convenient left or right connection for gas and electrical service • Cabinet air leakage (QLeak) ≤ 2% • Heavy-gauge steel cabinet with durable finish • Fully insulated heat exchanger and blower section • Airtight solid bottom or side return with easy-cut tabs for effortless removal in bottom air-inlet applications * Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), the 6-Year Unit Replacement Limited Warranty and the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Additional requirements for annual maintenance are required for the Unit Replacement Limited Warranty. Online registration and some of the additional requirements are not required in California or Quebec. SS-DM96HS www.daikincomfort.com 2/17 Supersedes 8/15 Nomenclature D M 96 H S 060 3 B N A A 1 2 3,4 5 6 7,8,9 10 11 12 13 14 Brand D  -­‐  Daikin  Brand Minor  Revision      A  -­‐  Initial  Release      B  -­‐  1st  Revision Configuration M  -­‐  Upflow/Horizontal C  -­‐  Downflow/Horizontal AFUE 97  –  97-­‐98%  AFUE Major  Revision      A  -­‐  Initial  Release      B  -­‐  1st  Revision 92  -­‐  92%  AFUE NOx      N  -­‐    Low  Nox  (40ng/J) 96  –  96%  AFUE Gas  Valve M  -­‐  Modulating V  -­‐  Two  Stage   H  -­‐  Convertible  Two-­‐Stage S  -­‐  Single  Stage Motor C  -­‐  Variable  Speed  ECM  /  ComfortNet E  -­‐  Multi-­‐Speed  ECM   S  -­‐  Single  Speed MBTU/h 040  -­‐  40,000  BTU/h 060  -­‐  60,000  BTU/h 080  -­‐  80,000  BTU/h 2 100  -­‐  100,000  BTU/h 120  -­‐  120,000  BTU/h www.daikincomfort.com Cabinet  Width      B  -­‐  17½"      C  -­‐  21"      D  -­‐  24½" Maximum  CFM      2  -­‐      800  CFM      3  -­‐  1200  CFM      4  -­‐  1600  CFM      5  -­‐  2000  CFM SS-DM96HS DM96HS Product Specifications DM96HS 0402BNA DM96HS 0603BNA DM96HS 0803BNA DM96HS 0804CNA DM96HS 0805CNA DM96HS 1005CNA DM96HS 1205DNA High Fire Input¹ 40,000 60,000 80,000 80,000 80,000 100,000 120,000 High Fire Output¹ 38,400 57,600 76,800 76,800 76,800 96,000 115,200 96 96 96 96 96 96 96 Temperature Rise Range (°F) 25 - 55 35 - 65 35 - 65 25 - 55 25 - 55 30 - 60 35 - 65 Vent Diameter³ 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3" 3" No. of Burners 2 3 4 4 4 5 6 Available AC @ 0.5" ESP 1.5 - 3 1.5 - 3 1.5 - 3 1.5 - 4 3-5 3-5 3-5 Size (D x W) Heating Data AFUE² Circulator Blower 10" x 8" 10" x 8" 10" x 8" 10" x 10" 11" x 10" 11" x 10" 11" x 11" Horsepower @ 1075 RPM ⅓ ⅓ ½ ½ ¾ ¾ ¾ Speed 4 4 4 4 4 4 4 9.6 9.6 12.8 11.7 13.7 13.7 13.7 Electrical Data Min. Circuit Ampacity⁴ Max. Overcurrent Device (amps)⁵ 15 15 15 15 15 15 15 Shipping Weight (lbs) 111 114 116 139 140 142 154 ¹ ² ³ ⁴ ⁵ Natural Gas BTU/h DOE AFUE based upon Isolated Combustion System (ICS) Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2" or 3" diameter PVC. Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. Notes • All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. • Gas Service Connection ½" FPT • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. • For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues. • For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. SS-DM96HS www.daikincomfort.com 3 Specifications – DC96HS DC96HS 0402BNA DC96HS 0603BNA DC96HS 0804CNA DC96HS 1005CNA DC96HS 1205DNA High Fire Input¹ 40,000 60,000 80,000 100,000 120,000 High Fire Output¹ 38,400 57,600 76,800 95,000 114,000 96 96 96 95 95 Temperature Rise Range (°F) 25 - 55 35 - 65 35 - 65 40 - 70 45 - 75 Vent Diameter³ 2" - 3" 2" - 3" 2" - 3" 2" - 3" 3" No. of Burners 2 3 4 5 6 Available AC @ 0.5" ESP 1.5 - 3 1.5 - 3 2.5 - 4 3-5 3-5 Size (D x W) Heating Data AFUE² Circulator Blower 10" x 8" 10" x 8" 10" x 10" 11" x 10" 11" x 11" Horsepower @ 1075 RPM ⅓ ⅓ ½ ¾ ¾ Speed 4 4 4 4 4 Permanent 427 512 683 768 844 Disposable 213 256 341 384 422 9.6 9.6 11.7 13.7 13.7 Filter Size (in²) Electrical Data Min. Circuit Ampacity⁴ Max. Overcurrent Device (amps)⁵ 15 15 15 15 15 Shipping Weight (lbs) 111 114 139 142 154 ¹ ² ³ ⁴ ⁵ Natural Gas BTU/h DOE AFUE based upon Isolated Combustion System (ICS) Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2" or 3" diameter PVC. Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. Notes • All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. • Gas Service Connection ½" FPT • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. • For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues. • For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. 4 www.daikincomfort.com SS-DM96HS DM96HS Dimensions Air Discharge Air Discharge 28¾ Air Intake 2" Pipe 6½ 2¾ A 2⅝ 2 C ¾ B Center Dimple For Alternate Air Intake Pipe 3" OD Hole High-Voltage Electrical Outlet Left-Side Drain Trap Exterior Holes 6½ 1⅞ ¾ ¾ 2 19½ Vent/ Flue Pipe 2" PVC Alternate Vent/ Flue Location Right-Side Drain Trap Exterior Holes High-Voltage Electrical Outlet Standard Gas Supply Location Alternate Gas Supply 34½ 31⅞ 23 26½ 24⅞ 23 19⅝ 21⅛ 19⅝ 14 9¼ 9¼ 5 1½ LEFT SIDE VIEW 5 1⅞ 2⅜ 2½ Low-voltage Electrical Outlet 1⅜ 1⅞ 22 E Folded Flanges Unfolded Flanges 23½ Folded Flanges Air Discharge Model RIGHT SIDE VIEW 2⅜ 2½ Low-Voltage Electrical Outlet D Unfolded Flanges Condensate Drain Trap Exterior Connection (Right or Left Side) ¾ PVC 23 ⅞ FRONT VIEW Air Return A B C D E DM96HS0402BNA 17½" 16" 13⅞" 12⅛" 13⅝" DM96HS0603BNA 17½" 16" 13⅞" 12⅛" 13⅝" DM96HS0803BNA 17½" 16" 13⅞" 12⅛" 13⅝" DM96HS0804CNA 21" 19½" 17⅜" 16" 17½" DM96HS0805CNA 21" 19½" 17⅜" 16" 17½" DM96HS1005CNA 21" 19½" 17⅜" 16" 17½" DM96HS1205DNA 24½" 23" 20⅞" 19⅜" 20⅞" Minimum Clearances to Combustible Materials Position Sides Rear Front Bottom Flue Top Upflow 0" 0" 3" C 0" 1" Horizontal 6" 0" 3" C 0" 6" C = If placed on combustible floor, the floor MUST be wood ONLY. SS-DM96HS www.daikincomfort.com 5 DC96HS Dimensions A B 2⅝ 1⅜ C 1⅞ 23 6½ 2½ 1⅝ 18¼ 1⅞ Alternate Vent/ Low-Voltage Electrical Outlet 1½ Low-Voltage Electrical Outlet 14 Alternate Gas Alternate Gas Supply High-Voltage Electrical Outlet 25⅛ 34½ 25⅛ 14⅞ 14¾ 14¾ 11⅜ 4⅛ Drain Trap Holes Standard Drain Trap 11⅜ 6⅞ 6⅞ 28¾ High-Voltage Electrical Outlet D Unfolded Flanges 2 2½ 3½ 2⅝ Right Side Exterior Drain Trap Holes Front View Air Discharge 20⅛ Folded Flanges 2 E Folded Flanges Air Return Model 18⅛ Unfolded Flanges Right-Side View Air Discharge Air Discharge A B C D E DC96HS0402BNA 17½" 14⅝" 14" 14½" 16" DC96HS0603BNA 17½" 14⅝" 14" 14½" 16" DC96HS0804CNA 21" 18⅛" 17½" 18" 19½" DC96HS1005CNA 21" 18⅛" 17½" 18" 19½" DC96HS1205DNA 24½" 21⅝" 21" 21½" 23" Minimum Clearances to Combustible Materials Position Sides Rear Front Bottom Flue Top Downflow 0" 0" 3" NC 0" 1" Horizontal 6" 0" 3" C 0" 6" C = If placed on combustible floor, the floor MUST be wood ONLY. NC = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring. 6 www.daikincomfort.com SS-DM96HS DM96HS Airflow Data (CFM & Temperature Rise vs. External Static Pressure) Model Motor Speed Tons AC¹ External Static Pressure, (Inches Water Column) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM High Med DM96HS 0402BNA Med-Lo Low 3 2.5 2 1.5 1,478 1,299 1,081 966 N/A 27 33 37 1,418 1,265 1,064 951 25 28 33 37 1,354 1,225 1,039 925 26 29 34 38 1,290 1,167 997 892 28 30 36 40 1,208 1,112 945 861 29 32 38 41 1,129 1,033 886 808 1,040 949 819 750 930 841 722 666 High Med DM96HS 0603BNA Med-Lo Low 3 2.5 2 1.5 1,432 1,289 1,080 967 37 41 49 55 1,374 1,250 1,057 945 39 43 50 56 1,319 1,204 1,022 919 40 44 52 58 1,237 1,142 980 879 43 47 54 61 1,157 1,066 926 844 46 50 58 63 1,063 981 861 789 958 897 785 712 854 789 700 632 High 3 1,620 44 1,561 46 1,478 48 1,401 51 1,322 54 1,239 1,150 1052 2.5 1,538 46 1,476 48 1,401 51 1,332 53 1,250 57 1,166 1,083 992 2 1,446 49 1,388 51 1,333 53 1,258 57 1,197 59 1,112 1,037 937 1.5 1,246 57 1,217 58 1,165 61 1,128 63 1,067 N/A 994 938 840 High Med DM96HS 0804CNA Med-Lo Low 4 3.5 3 2.5 1,795 1,691 1,488 1,244 40 42 48 N/A 1,720 1,622 1,445 1,222 41 44 49 N/A 1,642 1,563 1,403 1,198 43 45 51 N/A 1,555 1,486 1,338 1,157 46 48 53 N/A 1,467 1,394 1,260 1,119 48 51 N/A N/A 1,385 1,325 1,200 1,062 1,283 1,222 1,114 986 1,170 1,125 1,014 905 High Med DM96HS 0805CNA Med-Lo Low 5 4 3.5 3 2,233 1,820 1,571 1,361 32 39 45 52 2,159 1,778 1,535 1,333 33 40 46 53 2,086 1,742 1,497 1,290 34 41 48 55 2,024 1,695 1,446 1,255 35 42 49 N/A 1,941 1,638 1,402 1,208 37 43 51 N/A 1,850 1,551 1,338 1,171 1,753 1,485 1,280 1,104 1,651 1,384 1,204 1,051 High Med DM96HS 1005CNA Med-Lo Low 5 4 3.5 3 2,157 1,907 1,608 1,390 41 47 55 N/A 2,087 1,852 1,580 1,344 43 48 56 N/A 2,028 1,800 1,493 1,326 44 49 60 N/A 1,953 1,738 1,501 1,268 46 51 59 N/A 1,858 1,675 1,440 1,227 48 53 62 N/A 1,775 1,605 1,367 1,194 1,661 1,514 1,296 1,132 1,558 1,410 1,219 1,071 Med DM96HS 0803BNA Med-Lo Low High 5 2,204 48 2,144 50 2,080 51 1,991 54 1,914 56 1,817 1,724 1,595 Med 4 1,938 55 1,914 56 1,849 58 1,778 60 1,713 62 1,645 1,548 1,454 DM96HS 1205DNA Med-Lo Low ¹ 3.5 1,651 65 1,624 66 1,574 68 1,529 70 1,475 72 1,409 1,331 1,236 3 1,427 75 1,382 N/A 1,345 N/A 1,311 N/A 1,272 N/A 1,215 1,159 1,066 at 0.5" ESP Notes • CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. • All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. • This chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate. The shaded area indicates ranges in excess of maximum static pressure allowed when heating. • The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower. Minimum Filter Sizes DM96HS 0402BNA Filter Size (in²) (Qty) DM96HS 0603BNA DM96HS 0803BNA DM96HS 0804CNA (1) 16xX 25 (side or bottom) DM96HS 0805CNA DM96HS 1005CNA DM96HS 1205DNA (1) 20 x 25 (bottom) or (2) 16 x 25 (side) Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located. SS-DM96HS www.daikincomfort.com 7 DC96HS Airflow Data (CFM & Temperature Rise vs. External Static Pressure) Model Motor Speed Tons AC¹ External Static Pressure, (Inches Water Column) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM High Med DC96HS 0402BNA Med-Lo Low 3 2.5 2 1.5 1,425 1,254 1,082 889 25 28 33 40 1,345 1,218 1,051 872 26 29 34 41 1,271 1,155 1,007 829 28 31 35 43 1,198 1,107 965 815 30 32 37 44 1,138 1,040 910 765 31 34 39 46 1,051 952 841 711 945 869 770 659 864 761 660 585 High Med DC96HS 0603BNA Med-Lo Low 3 2.5 2 1.5 1,348 1,188 1,015 821 40 45 53 65 1,283 1,139 985 814 42 47 54 N/A 1,217 1,098 945 788 44 49 56 N/A 1,151 1,039 909 765 46 51 59 N/A 1,086 986 858 720 49 54 62 N/A 1,014 916 804 677 931 834 733 640 844 758 655 564 High Med DC96HS 0804CNA Med-Lo Low High Med DC96HS 1005CNA Med-Lo Low 1,736 41 1,613 44 1,578 45 1,498 47 1,409 50 1,314 1,226 1,119 1,657 43 1,583 45 1,501 47 1,441 49 1,366 52 1,282 1,173 1077 3 1,581 45 1,510 47 1,443 49 1,371 52 1,280 56 1,199 1,110 990 2.5 1,369 52 1,313 54 1,278 56 1,225 58 1,147 62 1,071 990 888 5 4 3.5 3 2,018 1,826 1,618 1,402 44 49 55 63 1,953 1,749 1,539 1,354 46 51 58 66 1,877 1,660 1,476 1,296 47 54 60 69 1,788 1,566 1,406 1,242 50 57 63 N/A 1,735 1,496 1,340 1,173 51 59 66 N/A 1,659 1,415 1,275 1,108 1,556 1,335 1,194 1,042 1,448 1,220 1,093 965 High 5 2,123 50 2,053 52 2,000 53 1,916 56 1,832 58 1,739 1,646 1,561 Med 4 1,912 56 1,844 58 1,770 60 1,708 62 1,619 66 1,543 1,436 1,349 3.5 1,684 63 1,622 66 1,578 68 1,503 71 1,442 74 1,374 1,302 1,204 3 1,493 71 1,436 74 1,371 N/A 1,319 N/A 1,264 N/A 1,208 1,153 1,061 DC96HS 1205DNA Med-Lo Low ¹ 4 3.5 at 0.5" ESP Notes • CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. • All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. • This chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate. The shaded area indicates ranges in excess of maximum static pressure allowed when heating. • The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower. Minimum Filter Sizes DC96HS 0402BNA Filter Size (in²) (Qty) DC96HS 0603BNA DC96HS 0804CNA (2) 10 x 20 or (1) 16 x 25 (top return) DC96HS 1005CNA DC96HS 1205DNA (1) 14 x 20 (bottom) or (1) 20 x 25 (top return) Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located. 8 www.daikincomfort.com SS-DM96HS SS-DM96HS www.daikincomfort.com 10 20 30 40 50 60 70 30 80 90 100 40 50 60 700 600 CFM 1200 90 100 2000 2200 2400 CFM 1800 1600 1400 OUTPUT BTU/HR x 1000 Output BTU/h x 1,000 80 1100 1000 900 70 800 Formulas FORMULAS 110 120 130 CFM x 1.08 140 BTUBTU/h OUTPUT 1.08 x RISE Output== CFM CFM xx1.08 x Rise BTU OUTPUT RISE = = BTU/H Output ÷ CFM Rise 1.08 BTUBTU OUTPUT TEMPERATURE RISEChart CHART OutputvsVs. Temperature Rise 150 Temperature Rise Range Chart 9 TEMPERATURE RISE Temperature Rise Wiring Diagram R G W Y BK ON GY OFF 3 2 1 6 5 4 9 8 7 12 11 10 2ND STAGE DELAY MODE YL * FS BR 2 WH W HLO (1) AUXILIARY LIMIT CONTROLS R RO2 (11) RO1 (5) GY BR OR PU BL PM C GY 1 N O FRONT COVER PRESSURE SWITCH GY GND C 2 HI 3 GND FLAME SENSOR STEADY ON = NORMAL OPERATION HI VOLTAGE (115V) 3 FLASHES = PRESSURE SWITCH STUCK OPEN HI VOLTAGE FIELD JUNCTION 5 FLASHES = FLAME SENSE WITHOUT GAS VALVE 8 FLASHES = CHECK IGNITER OR IMPROPER GROUNDING CONTINUOUS/RAPID FLASHES = REVERSED 115 VAC POLARITY COLOR CODES: YL YELLOW OR ORANGE PU PURPLE GN GREEN BK BLACK PK PINK BR BROWN WH WHITE BL BLUE GY GRAY RD RED DISCONNECT LOW VOLTAGE FIELD 4 FLASHES = OPEN HIGH LIMIT 7 FLASHES = LOW FLAME SIGNAL N GND BK LOW VOLTAGE (24V) OPEN ROLLOUT OR OPEN FUSE N WARNING:DISCONNECT POWER BEFORE SERVICING.WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. WH OR GAS VALVE (WHITE RODGERS) SYSTEM LOCKOUT (RETRIES EXCEEDED) 2 FLASHES = PRESSURE SWITCH STUCK CLOSED GND GR BR 7 JUNCTION BOX BL GR = CONTROL FAILURE L TERMINAL INTERNAL TO INTEGRATED CONTROL PLUG CONNECTION L TO 115 VAC / 1Ø /60HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE 24 VAC HUMIDIFIER 6 FLASHES = C RD PK MANUAL RESET ROLLOUT LIMIT CONTROL(S) ( SINGLE CONTROL ON 40K BTU) DISCONNECT TO 115VAC/1Ø /60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE OR C N O WARNING: DISCONNECT POWER BEFORE SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. WH 6 8 ELECTRONIC AIR CLEANER EAC-H WH INDUCED DRAFT BLOWER OR HOT SURFACE IGNITER 5 CIRCULATOR BLWR LINE-H YL 2 CIRCUIT CONNECTOR 3 LINE NEUTRALS OR OR BL HI - H AT HE JUNCTION BOX ID BLOWER PRESSURE SWITCH 4 ID BLWR COOL-H PU AUTO RESET PRIMARY LIMIT CONTROL 2 HOT SURFACE IGNITER DOOR SWITCH WH 1 FLASH = 115 VAC INTEGRATED CONTROL MODULE INTEGRATED CONTROL MODULE GR RD YL WH YL BK OFF 40 VA TRANSFORMER HE LO AT -H GND 1 24 VAC IND BURNER COMPARTMENT 0 MANUAL RESET ROLLOUT LIMIT CONTROL(S) (SINGLE CONTROL ON 40K BTU) FS WH AUXILIARY LIMIT CONTROLS BK CAPACITOR WH AUTO RESET PRIMARY LIMIT CONTROL IGN BLOWER COMPARTMENT RD NO FLAME SENSOR PK CIRCULATOR BLOWER BR C HLI (7) XFMR-H WH RD ID BLOWER PRESSURE SWITCH PSO (4) TH (3) LINE-H BK (HI) BL (MED) OR (MED LOW) RD (LOW) C NO PS (10) TO MICRO BK GND BR Y WH 1 HEAT-H G PK XFMR-H SEE NOTE 6 GR OR RD 115 VAC HOT AND PARK TERMINALS COOL-H BL OR FACTORY SETTINGS SHOWN DIAGNOSTIC LED PK OR 115 VAC NEUTRAL TERMINALS * HEAT OFF DELAY * * GY 24V THERMOSTAT CONNECTIONS FUSE PM FRONT COVER PRESSURE SWITCH BK OR INTEGRATED CONTROL MODULE MVL(2) C GAS VALVE C MVC (9) WH BK HI MVH (12) EQUIPMENT GND FIELD GND FIELD SPLICE SWITCH (TEMP.) IGNITER SWITCH (PRESS.) OVERCURRENT PROT. DEVICE ⚡ C GND GND (8) 40 VA TRANSFORMER 115 VAC INTEGRATED CONTROL MODULE HUMIDIFIER TR (6) High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. 24 VAC 24V THERMOSTAT CONNECTIONS BLOWER COMPARTMENT DOOR SWITCH (OPEN WHEN DOOR OPEN) GY ⚠ Warning OR Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 24 VAC HUMIDIFIER NOTES: 1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS . 2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. 3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACE D, IT MUST BE REPLACED WITH WIRING MATERIAL C. 105 HAVING A TEMPERATURE RATING OF AT LEAST 4. BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION REQUIREMENTS SO AS TO P ROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE CORRECT COOLING CFM. 5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. 6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (NO THERMOSTAT INPUTS) 0140F01916-A 10 www.daikincomfort.com SS-DM96HS Accessories – DM96HS / DC96HS DM96HS 0402BNA DM96HS 0603BNA DM96HS 0803BNA DM96HS 0804CNA DM96HS 0805CNA DM96HS 1005CNA DM96HS 1205DNA Concentric Vent Kit (2") √ √ √ √ √ √ --- √ √ √ √ √ √ √ --- --- Model CVENT-2 Description CVENT-3 Concentric Vent Kit (3") CFSB17 Downflow Sub-Base 17.5" --- --- --- --- --- CFSB21 Downflow Sub-Base 21" --- --- --- --- --- --- --- CFSB24 Downflow Sub-Base 24" --- --- --- --- --- --- --- RF000142 √ √ √ √ √ √ √ √ √ √ √ --- --- --- 0170K00000S Drain Kit -Horizontal Left Vertical Flue External Filter Rack with 16"x25" Permanent Filter Flush Mount Vent Kit - 3" or 2" √ √ √ √ √ √ √ 0170K00001S Flush Mount Vent Kit - 2" √ √ √ √ √ √ --- √ √ √ √ √ √ √ HASFK-4 HASFK-5 EFR02 AFE18-60A Fossil Fuel (Dual Fuel) Kit HASFK High-Altitude Natural Gas Kit HASFK-4 HASFK-4 HASFK-4 HASFK-4 HASFK-4 HASFK-4 HASFK High-Altitude LP Gas Kit HASFK-4 HASFK-6 HASFK-6 HASFK-6 HASFK-5 HASFK-5 LPLP03 Low LP Gas Pressure Switch √ √ √ √ √ √ √ LPM-08 LP Conversion Kits √ √ √ √ √ √ √ FTK04 Twinning Kit √ √ √ √ √ √ √ Model CVENT-2 Description Concentric Vent Kit (2") DC96HS 0402BNA DC96HS 0603BNA DC96HS 0804CNA DC96HS 1005CNA DC96HS 1205DNA √ √ √ √ --- CVENT-3 Concentric Vent Kit (3") √ √ √ √ √ CFSB17 Downflow Sub-Base 17.5" √ √ --- --- ----- CFSB21 Downflow Sub-Base 21" --- --- √ √ CFSB24 Downflow Sub-Base 24" --- --- --- --- √ RF000142 --- --- --- --- --- √ √ √ --- --- 0170K00000S Drain Kit -Horizontal Left Vertical Flue External Filter Rack with 16"x25" Permanent Filter Flush Mount Vent Kit - 3" or 2" √ √ √ √ √ 0170K00001S Flush Mount Vent Kit - 2" √ √ √ √ --- EFR02 AFE18-60A Fossil Fuel (Dual Fuel) Kit √ √ √ √ √ HASFK High-Altitude Natural Gas Kit HASFK-4 HASFK-4 HASFK-4 HASFK-4 HASFK-4 HASFK-4 HASFK High-Altitude LP Gas Kit HASFK-5 HASFK-5 HASFK-5 HASFK-4 LPLP03 Low LP Gas Pressure Switch √ √ √ √ √ LPM-08 LP Conversion Kits √ √ √ √ √ FTK04 Twinning Kit √ √ √ √ √ Notes √ Indicates available for this model ² Indicates 9,001' to 11,000' altitude ¹ Indicates 7,001' to 9,000' altitude ³ Indicates 7,001' to 11,000' altitude • All installations above 7,000' require a pressure switch change. • For installation in Canada, gas furnaces are certified only to 4,500'. SS-DM96HS www.daikincomfort.com 11 Notes Our continuing commitment to quality products may mean a change in specifications without notice. © 2017 • Houston, Texas 12 www.daikincomfort.com SS-DM96HS