Preview only show first 10 pages with watermark. For full document please download

D:\my Document-gms1980\客戶資料\誠方

   EMBED


Share

Transcript

Optical Report For Solid-State Lighting Products This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to the joint ISO-ILAC-IAF Communiqué dated January 2009). Standard Used : IESNA LM-79-08, Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products. Date of Test : January 28, 2014 Date of Issue : May 13, 2014 Report Number : GO1404290504 Total Number of Pages : 20 Report No. : GO1404290504 www.GO-SAFETY.com.tw Total Page : 1/20 Report No. : GO1404290504 www.GO-SAFETY.com.tw Total Page : 2/20 Report No. : GO1404290504 www.GO-SAFETY.com.tw Total Page : 3/20 TEST REPORT The Optical Report For Solid-State Lighting Products Report Number. ....................... : GO1404290504 Date of test ................................. : January 28, 2014 Date of issue .............................. : May 13, 2014 Tested by (printed name and signature) …..: Reported by (printed name and signature)…..: Approved by (printed name and signature) …..: Tim Liu Tim Liu Tim Liu Tim Liu David Yuan David Yuan Testing Laboratory……………: Great One Global Certification Co., Ltd. Address…………………………: 9F-2, No. 120, Qiaohe Road., Zhonghe Dist., New Taipei City 235, Taiwan (R.O.C.) Applicant’s name...................... : EYE Lighting International of North America Inc. Address ...................................... : 9150 Hendricks Road, Mentor, Ohio 44060 (U.S.A.) Standard Used………………….: IESNA LM-79-08, Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products Test item description ................. : GL Series LED Luminaire Product Name .............................. : Model/Type reference………….: GL-X-100-40-7-W-U-XX Ratings ...................................... : 100 Vac to 277 Vac, 50/60 Hz, 100 W Reported By : Reviewed By : Tim Liu Project Engineer David Yuan Manager 1. The test results of this report relate only to the tested sample identified in this report. 2. This report shall not be reproduced, in full or in portion, except for having written approval from Great One Global Certification Co., Ltd. 3. The data in report cannot be used for advertisement, publication and promotion. Report No. : GO1404290504 www.GO-SAFETY.com.tw Total Page : 4/20 SUMMARY OF PHOTOMETRY TEST: 1. Test Method : The sample was tested according to the LM-79-2008. A Type C High Speed Mirror Type Goniophotometer was used to measure the intensity (candelas) at each angle of distribution for each sample. A Spectroradiometer and a Integrating Sphere were used to measure correlated color temperature, chromaticity coordinates, and the color rendering index for each sample. Chromaticity coordinates, correlated color temperature and color rendering index were calculated from the spectral radiant flux measurements taken at 5 nm intervals over the range of 380 to 780 nm.The calibration of the sphere photometer-spectroradiometer system is traceable to the National Institute of Standards and Technology. The ambient temperature shall be maintained at 25°C ± 1°C. Each sample was operated at input rated voltage in its designated orientation. Electrical measurements including voltage, current, and power were measured using the Yokogawa Power Analyzer. Deviation from Standard operating procedures – None. 2.Test item particulars : Tested lamp ....................................................... :  continuous wave lamps  pulsed lamps Tested lamp system ........................................... : LED Lamp cap .......................................................... : N/A Bulb .................................................................. : N/A Rated of the lamp .............................................. : 100 Vac to 277 Vac, 50/60 Hz, 100 W Temperature by measurement ............................ : 24.5 °C Humidity by measurement ................................ : 54.0 % 3.Description of EUT Setup : Operating Orientation ....................................... : The light source is considered as horizontal Light Source ..................................................... : LED Stabilization time.............................................. : 1 Hour Report No. : GO1404290504 www.GO-SAFETY.com.tw Total Page : 5/20 4. Photograph of EUT of Sample : Report No. : GO1404290504 www.GO-SAFETY.com.tw Total Page : 6/20 RESULTS (1) Input Voltage/Frequency:110.00 V ac / 60 Hz (2) Input Watt:100.26 W (3) Input Current:0.915 A (4) Total Luminous Flux Output : 10062.17 lm (5) Luminaire Efficacy:100.36 lm/W (6) Central Intensity (cd) : 3558.905 (7) Maximum Intensity(cd) : 4250.408 (8) PF: 0.996 (9) Beam angle: (C0-C180) 108.4 (C90-C270) 108.8 (10) Color Rendering Index (CRI): 72.8 (11) Correlated Color Temperature (CCT): 4006 K (12) THD at 120 Vac: V%: 0.10, A%: 6.96 (13) PF at 277 Vac: 0.959 (14) THD at 277 Vac: V%: 0.06, A%: 11.05 Measurement Results : See Appendix A for details. Report No. : GO1404290504 www.GO-SAFETY.com.tw Total Page : 7/20 Equipments List Equipment ID Equipment Type Cal. Date Due Date L201 Integrating Sphere N/A N/A L202 Spetroradiometer N/A N/A L203 AC Power Source N/A N/A L204 Goniophotometer Photo Detector N/A N/A L205 Goniophotometer System N/A N/A L206 AC Power Source N/A N/A L207 Power Meter 2013/12/13 2014/12/12 L244 Standard Light Source 2014/01/03 2015/01/02 L221 Luminous Intensity Lamp 2013/11/13 2014/11/12 L222 Report No. : GO1404290504 Power Meter 2013/10/11 www.GO-SAFETY.com.tw 2014/10/10 Range Used V : Auto (0~300Vac) A : Auto (0~20A) V : Auto (0~300Vac) A : Auto (0~20A) Total Page : 8/20 Appendix A Great One Global Certification Co., Ltd. =========================================================================== Product: GL-X-100-40-7-W-U-XX Manufacturer: EYE Lighting International of North America Inc. Sample No.: 14012705-2 Date: 1-28-2014 Tested By: Tim Liu Reviewed By: David Yuan Test Condition Temperature: 25.4°C Spectrum Range: 350-800 nm RH: 55.0% Scan Step: 5 nm Spectroradiometric Parameters 1.0 0.8 0.6 0.4 0.2 0 350 425 500 575 650 725 800 Spectral Distribution SDCM:ANSI_LED_4000K x0=0.3818 y0=0.3797 Chromaticity Coordinates: x=0.3808 y=0.3789 u'=0.2245 v'=0.5026 Correlated Color Temperature: 4006 K Dominant Wavelength: 577.0 nm(E) Chromaticity Difference: +0.0009Duv Purity: 0.2801 Color Ratio: Kr=36.8% Kg=56.3% Kb=6.9% Peak Wavelength: 444.3 nm Bandwidth: 22nm Color Tolerance: 0.0 SDCM Rendering Index: Ra=72.8 Radiant Flux: 32.506 W R1=71 R2=78 R3=82 R4=74 R5=70 R6=68 R7=81 R9=-15 R10=47 R11=70 R12=45 R13=72 R14=89 R15=66 Report No. : GO1404290504 www.GO-SAFETY.com.tw R8=58 Total Page : 9/20 Appendix A EYE Lighting International of North America Inc. Zonal flux distribution table γ(°) Average I(cd) Zonal F(lm) Sum F(lm) Eff Flux(lm) Eff Sum(lm) 0.0 3546.496 .000 .000 .000% .000% 5.0 3574.351 85.128 85.128 .846% .846% 10.0 3605.397 256.842 341.970 2.553% 3.399% 15.0 3678.050 432.049 774.019 4.294% 7.692% 20.0 3799.550 616.259 1390.278 6.125% 13.817% 25.0 3907.407 808.318 2198.596 8.033% 21.850% 30.0 3936.583 992.664 3191.260 9.865% 31.715% 35.0 3818.956 1142.057 4333.317 11.350% 43.065% 40.0 3535.780 1227.082 5560.399 12.195% 55.260% 45.0 3167.806 1241.223 6801.622 12.336% 67.596% 50.0 2674.481 1180.519 7982.142 11.732% 79.328% 55.0 1984.166 1012.945 8995.087 10.067% 89.395% 60.0 924.761 672.390 9667.478 6.682% 96.077% 65.0 214.483 276.953 9944.430 2.752% 98.830% 70.0 63.718 70.442 10014.870 .700% 99.530% 75.0 26.722 23.640 10038.510 .235% 99.765% 80.0 12.506 10.497 10049.010 .104% 99.869% 85.0 5.802 4.975 10053.980 .049% 99.919% 90.0 1.276 1.938 10055.920 .019% 99.938% 95.0 .524 .493 10056.410 .005% 99.943% 100.0 .543 .290 10056.700 .003% 99.946% 105.0 .625 .313 10057.020 .003% 99.949% 110.0 .706 .348 10057.360 .003% 99.952% 115.0 .830 .389 10057.750 .004% 99.956% 120.0 .922 .426 10058.180 .004% 99.960% 125.0 1.021 .449 10058.630 .004% 99.965% 130.0 1.113 .464 10059.090 .005% 99.969% 135.0 1.223 .472 10059.560 .005% 99.974% 140.0 1.294 .466 10060.030 .005% 99.979% 145.0 1.384 .447 10060.480 .004% 99.983% 150.0 1.421 .413 10060.890 .004% 99.987% 155.0 1.472 .366 10061.250 .004% 99.991% 160.0 1.569 .319 10061.570 .003% 99.994% 165.0 1.527 .255 10061.830 .003% 99.997% 170.0 1.600 .185 10062.010 .002% 99.998% 175.0 1.663 .117 10062.130 .001% 100.000% 180.0 1.681 .040 10062.170 .000% 100.000% Equipment: HW-1015 Temperature(°C): 24.5 Report No. : GO1404290504 Date: 2014/1/28 Humidity(%): 54.0% www.GO-SAFETY.com.tw Operator: Tim Liu Distance(m): 8.90 Total Page : 10/20 Appendix A EYE Lighting International of North America Inc. Zonal flux distribution table ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixt 0-30 3191.3 31.7% 31.7% 0-40 5560.4 55.3% 55.3% 0-60 9667.5 96.1% 96.1% 0-90 10055.9 99.9% 99.9% 90-120 2.3 0.0% 0.0% 90-130 3.2 0.0% 0.0% 90-150 5.0 0.0% 0.0% 90-180 6.2 0.1% 0.1% 0-180 10062.2 100.0% 100.0% ZONAL LUMEN SUMMARY Equipment: HW-1015 Temperature(°C): 24.5 Report No. : GO1404290504 0-10 342.0 10-20 1048.3 20-30 1801.0 30-40 2369.1 40-50 2421.7 50-60 1685.3 60-70 347.4 70-80 34.1 80-90 6.9 90-100 0.8 100-110 0.7 110-120 0.8 120-130 0.9 130-140 0.9 140-150 0.9 150-160 0.7 160-170 0.4 170-180 0.1 Date: 2014/1/28 Humidity(%): 54.0% www.GO-SAFETY.com.tw Operator: Tim Liu Distance(m): 8.90 Total Page : 11/20 Appendix A EYE Lighting International of North America Inc. Light Distribution Curve [Unit: cd] ±180° -90° 90° 850.08 1700.16 2550.25 3400.33 4250.41 0° 4250.41 3400.33 2550.25 1700.16 850.08 0.00 -180° -135° -90° -45° 0° 45° 90° 135° 180° C0/C180: C90/C270: Equipment: HW-1015 Temperature(°C): 24.5 Report No. : GO1404290504 Date: 2014/1/28 Humidity(%): 54.0% www.GO-SAFETY.com.tw Operator: Tim Liu Distance(m): 8.90 Total Page : 12/20 Appendix A EYE Lighting International of North America Inc. Lux distance Curve 1.0m 2.0m 3.0m 4.0m 5.0m 6.0m 7.0m 8.0m 9.0m 10.0m 11.0m 12.0m 3558.91lx 889.73lx 395.43lx 222.43lx 142.36lx 98.86lx 72.63lx 55.61lx 43.94lx 35.59lx 29.41lx 24.71lx Height E Equipment: HW-1015 Temperature(°C): 24.5 Report No. : GO1404290504 Date: 2014/1/28 Humidity(%): 54.0% www.GO-SAFETY.com.tw Operator: Tim Liu Distance(m): 8.90 Total Page : 13/20 Appendix A EYE Lighting International of North America Inc. ISO-Intensity(V-H) 90° Imax:4250.41cd [Unit:cd] 75° 60° 45° 30° 15° 0° -15° -30° -45° -60° -75° -90° -90° -75° -60° -45° -30° -15° 0° 15° 30° 45° 60° 75° 90° (10%Imax) 424.635 (20%Imax) 849.269 (30%Imax) 1273.9 (40%Imax) 1698.54 (50%Imax) 2123.17 (60%Imax) 2547.81 (70%Imax) 2972.44 (80%Imax) 3397.08 (90%Imax) 3821.71 Equipment: HW-1015 Temperature(°C): 24.5 Report No. : GO1404290504 Date: 2014/1/28 Humidity(%): 54.0% www.GO-SAFETY.com.tw Operator: Tim Liu Distance(m): 8.90 Total Page : 14/20 Appendix A EYE Lighting International of North America Inc. ISO illuminance diagram 1.7d/h Imax:4250.41cd [Unit:lx] H=9.0m 1.3 1.0 0.7 0.3 0.0 0.3 0.7 1.0 1.3 1.7d/h 1.7d/h 1.3 1.0 0.7 0.3 0.0 0.3 0.7 1.0 1.3 1.7d/h (10%Emax) 4.389308 (20%Emax) 8.778617 (30%Emax) 13.1679 (40%Emax) 17.55728 (50%Emax) 21.94654 (60%Emax) 26.3358 (70%Emax) 30.72519 (80%Emax) 35.11444 (90%Emax) 39.50383 Equipment: HW-1015 Temperature(°C): 24.5 Report No. : GO1404290504 Date: 2014/1/28 Humidity(%): 54.0% www.GO-SAFETY.com.tw Operator: Tim Liu Distance(m): 8.90 Total Page : 15/20 Appendix A EYE Lighting International of North America Inc. Intensity data(cd) C/γ(°) 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 110.0 120.0 130.0 140.0 150.0 160.0 170.0 180.0 190.0 200.0 210.0 220.0 230.0 240.0 250.0 260.0 270.0 280.0 290.0 300.0 310.0 320.0 330.0 340.0 350.0 360.0 0.0 3558.91 3573.96 3560.49 3562.87 3556.53 3554.15 3569.99 3547.02 3524.05 3509.80 3513.76 3521.68 3532.77 3549.40 3546.23 3543.86 3550.98 3560.49 3558.91 3573.96 3560.49 3562.87 3556.53 3554.15 3569.99 3547.02 3524.05 3509.80 3513.76 3521.68 3532.77 3549.40 3546.23 3543.86 3550.98 3560.49 3558.91 Equipment: HW-1015 Temperature(°C): 24.5 Report No. : GO1404290504 5.0 3590.59 3581.88 3573.16 3573.96 3569.20 3569.99 3592.97 3560.49 3540.69 3537.52 3544.65 3552.57 3562.07 3572.37 3572.37 3566.03 3573.16 3585.04 3585.84 3605.64 3593.76 3607.22 3603.26 3592.17 3601.68 3575.54 3547.02 3534.35 3545.44 3549.40 3569.99 3585.04 3583.46 3583.46 3594.55 3600.09 3590.59 10.0 3649.20 3621.48 3619.90 3600.89 3591.38 3590.59 3611.18 3581.08 3558.91 3552.57 3562.87 3577.12 3579.50 3587.42 3587.42 3585.84 3600.89 3615.94 3606.43 3650.00 3626.23 3626.23 3628.61 3618.31 3624.65 3622.27 3588.21 3586.63 3586.63 3591.38 3601.68 3612.77 3611.98 3637.32 3646.83 3653.96 3649.20 15.0 3753.76 3688.02 3663.46 3665.05 3642.87 3635.74 3653.96 3623.86 3620.69 3615.94 3615.94 3615.14 3623.07 3632.57 3642.08 3635.74 3657.92 3680.89 3671.38 3726.04 3703.86 3699.11 3699.90 3712.57 3720.49 3726.83 3697.52 3697.52 3693.56 3695.15 3701.48 3695.94 3697.52 3724.45 3730.00 3749.80 3753.76 20.0 3861.49 3790.99 3769.60 3751.39 3741.88 3745.05 3792.57 3775.94 3763.27 3764.06 3751.39 3745.84 3743.46 3741.88 3740.30 3727.62 3748.22 3775.15 3765.64 3821.09 3803.66 3820.30 3849.61 3868.62 3855.15 3855.94 3821.88 3820.30 3815.55 3826.64 3841.69 3857.53 3848.02 3860.70 3853.57 3867.82 3861.49 25.0 3884.46 3875.75 3876.54 3890.80 3927.23 3941.49 3920.90 3858.32 3822.67 3814.75 3824.26 3844.85 3902.68 3935.94 3890.00 3839.31 3832.97 3840.10 3825.84 3829.80 3865.45 3974.76 4063.47 4055.55 3967.63 3919.31 3870.20 3865.45 3870.20 3916.93 3994.56 4085.65 4053.18 3984.26 3910.60 3890.80 3884.46 Date: 2014/1/28 Humidity(%): 54.0% www.GO-SAFETY.com.tw 30.0 3769.60 3859.11 3917.73 4046.05 4139.51 4097.53 3961.29 3852.77 3769.60 3775.15 3798.91 3886.04 4026.24 4139.51 4076.94 3912.97 3816.34 3779.11 3771.98 3746.63 3848.81 4063.47 4204.47 4186.25 4000.90 3856.73 3780.69 3761.68 3799.70 3920.90 4099.91 4250.41 4183.87 4001.69 3840.89 3773.56 3769.60 35.0 3523.26 3698.31 3818.71 4055.55 4202.09 4115.75 3889.21 3711.78 3596.93 3607.22 3658.71 3794.16 4020.70 4174.37 4093.57 3861.49 3684.06 3611.18 3612.77 3521.68 3699.90 3958.12 4138.72 4082.48 3861.49 3643.66 3547.82 3530.39 3604.06 3771.19 4052.38 4204.47 4107.83 3856.73 3631.78 3539.90 3523.26 40.0 3220.68 3393.36 3586.63 3840.89 3966.84 3867.03 3650.79 3420.29 3291.18 3272.17 3348.21 3544.65 3796.54 3914.56 3851.98 3641.28 3409.20 3329.20 3343.45 3225.43 3446.43 3703.86 3762.48 3753.76 3597.72 3345.83 3231.77 3196.92 3302.26 3509.80 3769.60 3839.31 3765.64 3583.46 3342.66 3222.26 3220.68 Operator: Tim Liu Distance(m): 8.90 Total Page : 16/20 Appendix A EYE Lighting International of North America Inc. Intensity data(cd) C/γ(°) 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 110.0 120.0 130.0 140.0 150.0 160.0 170.0 180.0 190.0 200.0 210.0 220.0 230.0 240.0 250.0 260.0 270.0 280.0 290.0 300.0 310.0 320.0 330.0 340.0 350.0 360.0 45.0 2842.06 3074.93 3307.02 3488.41 3564.45 3445.64 3306.23 3081.27 2921.27 2917.30 2998.89 3219.89 3432.96 3493.16 3444.84 3345.83 3115.33 2986.22 2996.51 2881.66 3097.11 3254.74 3348.21 3316.52 3212.76 2995.72 2887.20 2817.50 2933.94 3171.57 3318.90 3411.57 3334.74 3220.68 2971.96 2884.04 2842.06 Equipment: HW-1015 Temperature(°C): 24.5 Report No. : GO1404290504 50.0 2306.60 2659.87 2872.95 2929.98 3089.19 2963.25 2805.62 2650.37 2487.99 2483.23 2575.91 2738.29 2849.18 3027.41 2962.45 2837.30 2686.80 2546.60 2514.92 2365.21 2526.80 2678.09 2841.26 2794.53 2648.78 2579.87 2377.88 2358.87 2502.24 2636.90 2752.55 2903.05 2843.64 2636.90 2492.74 2354.12 2306.60 55.0 1465.62 2038.87 2225.01 2324.81 2520.46 2374.72 2190.16 2053.12 1811.53 1817.87 1929.56 2121.24 2303.43 2471.35 2381.84 2192.53 2040.45 1834.50 1850.35 1504.83 1554.18 2070.55 2270.95 2247.19 1962.82 1577.94 1528.91 1490.89 1572.08 1941.44 2160.06 2326.40 2236.89 1981.83 1577.63 1477.98 1465.62 60.0 271.77 730.32 1108.15 1524.00 1833.71 1687.97 1217.46 755.66 560.81 578.23 704.18 1032.90 1551.72 1858.27 1645.19 1223.79 786.56 562.39 574.27 301.47 513.60 1077.41 1559.41 1339.60 796.38 337.91 296.48 305.28 362.70 637.80 1177.22 1558.85 1352.27 813.25 339.97 314.46 271.77 65.0 150.90 118.74 125.94 425.36 773.88 458.63 151.53 73.19 153.27 150.97 105.43 94.10 428.53 788.93 454.67 168.32 78.73 165.63 157.23 92.04 59.41 148.28 387.50 206.82 109.55 54.81 154.46 149.31 102.02 63.29 138.22 460.92 239.14 112.64 63.13 155.89 150.90 70.0 87.21 63.84 40.71 64.24 65.03 69.86 60.52 44.44 104.95 112.87 61.94 35.72 59.57 54.10 68.68 65.11 47.13 120.00 116.91 55.05 34.85 53.94 38.97 65.59 48.71 45.86 79.84 80.08 54.65 34.77 57.11 45.78 60.20 58.22 45.31 92.04 87.21 Date: 2014/1/28 Humidity(%): 54.0% www.GO-SAFETY.com.tw 75.0 29.70 31.21 25.90 30.97 24.71 37.31 22.26 31.29 30.50 32.48 28.99 24.48 28.99 24.56 33.82 25.74 32.48 34.22 37.39 23.68 19.56 19.25 21.70 21.94 19.33 24.71 24.40 27.25 25.19 22.65 21.07 24.24 27.72 19.96 24.71 27.64 29.70 80.0 12.67 14.81 12.75 11.96 13.54 11.80 11.33 12.36 12.67 12.52 12.36 11.09 11.41 13.47 12.52 12.44 13.94 14.81 14.97 12.59 11.49 11.01 12.75 11.01 11.09 11.80 12.83 12.20 13.15 11.72 11.25 13.70 12.75 11.88 12.44 13.15 12.67 85.0 4.99 6.57 6.73 6.42 6.50 5.78 5.47 5.15 4.91 4.83 5.15 4.99 5.70 6.57 6.50 6.50 6.73 6.81 6.65 5.54 5.54 5.78 5.62 5.54 5.47 5.70 5.15 4.99 5.39 5.62 5.54 6.57 6.50 5.94 5.70 5.31 4.99 Operator: Tim Liu Distance(m): 8.90 Total Page : 17/20 Appendix A EYE Lighting International of North America Inc. Intensity data(cd) C/γ(°) 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 110.0 120.0 130.0 140.0 150.0 160.0 170.0 180.0 190.0 200.0 210.0 220.0 230.0 240.0 250.0 260.0 270.0 280.0 290.0 300.0 310.0 320.0 330.0 340.0 350.0 360.0 90.0 0.95 1.50 1.66 1.58 1.50 1.43 1.19 1.11 1.11 1.03 1.11 1.11 1.43 1.66 1.66 1.50 1.66 1.66 1.82 1.03 1.11 0.87 1.27 1.03 1.35 1.19 1.19 1.19 1.27 1.19 1.03 1.11 1.19 1.19 1.11 0.95 0.95 Equipment: HW-1015 Temperature(°C): 24.5 Report No. : GO1404290504 95.0 0.48 0.55 0.55 0.63 0.48 0.55 0.48 0.63 0.63 0.55 0.63 0.55 0.63 0.63 0.48 0.48 0.63 0.48 0.55 0.48 0.48 0.48 0.48 0.48 0.40 0.55 0.48 0.48 0.48 0.48 0.48 0.48 0.55 0.48 0.48 0.55 0.48 100.0 0.55 0.63 0.55 0.55 0.63 0.55 0.55 0.55 0.63 0.71 0.55 0.63 0.63 0.55 0.55 0.55 0.55 0.63 0.55 0.55 0.40 0.48 0.55 0.48 0.55 0.55 0.48 0.48 0.48 0.48 0.63 0.48 0.48 0.40 0.48 0.48 0.55 105.0 0.48 0.71 0.71 0.71 0.71 0.71 0.63 0.71 0.63 0.63 0.63 0.71 0.79 0.71 0.71 0.71 0.55 0.63 0.55 0.63 0.55 0.63 0.63 0.71 0.55 0.55 0.63 0.48 0.48 0.48 0.55 0.63 0.63 0.63 0.55 0.48 0.48 110.0 0.71 0.71 0.71 0.71 0.79 0.79 0.79 0.71 0.63 0.71 0.71 0.71 0.87 0.87 0.79 0.79 0.63 0.71 0.63 0.63 0.63 0.71 0.71 0.79 0.71 0.55 0.71 0.55 0.63 0.63 0.79 0.71 0.63 0.63 0.71 0.63 0.71 115.0 0.71 0.79 0.87 0.87 1.03 0.95 0.87 0.79 0.79 0.79 0.87 0.95 0.87 1.03 0.87 0.79 0.87 0.79 0.87 0.79 0.87 0.87 0.87 0.71 0.79 0.79 0.71 0.71 0.71 0.71 0.87 0.79 0.95 0.79 0.79 0.71 0.71 Date: 2014/1/28 Humidity(%): 54.0% www.GO-SAFETY.com.tw 120.0 0.87 0.87 0.95 1.03 1.03 0.95 0.95 0.95 0.87 1.03 0.95 1.03 1.03 1.03 1.03 0.95 0.87 0.95 1.03 0.87 0.95 0.87 1.03 0.95 0.87 0.87 0.79 0.79 0.87 0.87 0.79 0.95 0.87 0.87 0.79 0.79 0.87 125.0 0.79 1.11 1.03 1.27 1.19 1.19 1.03 1.11 1.03 1.03 1.11 0.95 1.11 1.11 1.11 1.11 1.19 1.11 1.03 0.87 0.87 1.03 1.11 1.03 0.95 0.95 0.79 0.87 0.95 0.87 0.95 1.03 0.95 1.03 0.95 0.95 0.79 130.0 0.95 1.19 1.11 1.19 1.19 1.19 1.19 1.03 1.19 1.11 1.11 1.27 1.27 1.27 1.27 1.19 1.27 1.19 1.11 1.03 1.03 0.95 1.11 1.03 1.03 1.03 0.95 1.11 1.03 0.95 1.11 1.11 1.19 1.11 1.03 1.03 0.95 Operator: Tim Liu Distance(m): 8.90 Total Page : 18/20 Appendix A EYE Lighting International of North America Inc. Intensity data(cd) C/γ(°) 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 110.0 120.0 130.0 140.0 150.0 160.0 170.0 180.0 190.0 200.0 210.0 220.0 230.0 240.0 250.0 260.0 270.0 280.0 290.0 300.0 310.0 320.0 330.0 340.0 350.0 360.0 135.0 1.03 1.27 1.35 1.35 1.43 1.35 1.43 1.35 1.27 1.27 1.27 1.43 1.43 1.27 1.35 1.27 1.27 1.27 1.19 1.19 1.11 1.27 1.19 1.19 1.11 1.19 1.11 1.03 0.95 1.03 1.19 1.19 1.19 1.19 1.11 1.03 1.03 Equipment: HW-1015 Temperature(°C): 24.5 Report No. : GO1404290504 140.0 1.11 1.58 1.50 1.50 1.43 1.43 1.35 1.43 1.35 1.43 1.43 1.35 1.50 1.43 1.43 1.43 1.35 1.35 1.50 1.11 1.11 1.27 1.19 1.11 1.19 1.19 1.19 1.11 1.11 1.11 1.11 1.19 1.19 1.19 1.19 1.19 1.11 145.0 1.19 1.58 1.58 1.58 1.50 1.50 1.43 1.43 1.50 1.58 1.58 1.50 1.50 1.58 1.50 1.50 1.58 1.58 1.66 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.19 1.11 1.11 1.27 1.35 1.11 1.19 1.27 1.27 1.19 1.19 150.0 1.27 1.66 1.66 1.58 1.58 1.58 1.50 1.43 1.43 1.58 1.66 1.66 1.58 1.50 1.50 1.58 1.58 1.58 1.74 1.19 1.19 1.27 1.35 1.27 1.27 1.27 1.19 1.35 1.19 1.19 1.27 1.35 1.27 1.35 1.27 1.27 1.27 155.0 1.19 1.74 1.74 1.66 1.66 1.58 1.50 1.66 1.50 1.58 1.58 1.58 1.66 1.66 1.66 1.66 1.66 1.66 1.74 1.35 1.43 1.35 1.35 1.35 1.27 1.27 1.27 1.27 1.19 1.19 1.27 1.27 1.43 1.27 1.43 1.35 1.19 160.0 1.43 1.82 1.82 1.90 1.74 1.74 1.66 1.74 1.74 1.74 1.74 1.74 1.66 1.82 1.74 1.74 1.74 1.82 1.74 1.43 1.43 1.43 1.27 1.43 1.43 1.27 1.27 1.35 1.27 1.43 1.27 1.50 1.35 1.35 1.43 1.50 1.43 Date: 2014/1/28 Humidity(%): 54.0% www.GO-SAFETY.com.tw 165.0 1.43 1.66 1.58 1.66 1.58 1.74 1.58 1.66 1.66 1.66 1.66 1.66 1.58 1.66 1.74 1.66 1.82 1.66 1.66 1.58 1.35 1.35 1.43 1.35 1.27 1.35 1.43 1.35 1.27 1.35 1.43 1.43 1.50 1.43 1.35 1.43 1.43 170.0 1.58 1.74 1.66 1.74 1.74 1.66 1.58 1.66 1.58 1.74 1.66 1.74 1.66 1.66 1.74 1.66 1.74 1.82 1.74 1.50 1.50 1.58 1.35 1.50 1.43 1.35 1.43 1.43 1.43 1.50 1.50 1.58 1.66 1.66 1.50 1.50 1.58 175.0 1.66 1.74 1.74 1.74 1.74 1.66 1.66 1.58 1.58 1.66 1.66 1.66 1.66 1.66 1.74 1.74 1.82 1.74 1.74 1.66 1.66 1.58 1.66 1.58 1.50 1.58 1.66 1.66 1.58 1.58 1.66 1.58 1.66 1.66 1.66 1.66 1.66 Operator: Tim Liu Distance(m): 8.90 Total Page : 19/20 Appendix A EYE Lighting International of North America Inc. Intensity data(cd) C/γ(°) 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 110.0 120.0 130.0 140.0 150.0 160.0 170.0 180.0 190.0 200.0 210.0 220.0 230.0 240.0 250.0 260.0 270.0 280.0 290.0 300.0 310.0 320.0 330.0 340.0 350.0 360.0 180.0 1.74 1.66 1.66 1.74 1.74 1.66 1.66 1.66 1.58 1.66 1.58 1.66 1.66 1.66 1.74 1.66 1.74 1.74 1.74 1.66 1.66 1.74 1.74 1.66 1.66 1.66 1.58 1.66 1.58 1.66 1.66 1.66 1.74 1.66 1.74 1.74 1.74 Equipment: HW-1015 Temperature(°C): 24.5 Report No. : GO1404290504 Date: 2014/1/28 Humidity(%): 54.0% www.GO-SAFETY.com.tw Operator: Tim Liu Distance(m): 8.90 Total Page : 20/20