Transcript
Optical Report For Solid-State Lighting Products
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to the joint ISO-ILAC-IAF Communiqué dated January 2009).
Standard Used :
IESNA LM-79-08, Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products. Date of Test : January 28, 2014 Date of Issue : May 13, 2014 Report Number : GO1404290504 Total Number of Pages : 20
Report No. : GO1404290504
www.GO-SAFETY.com.tw
Total Page : 1/20
Report No. : GO1404290504
www.GO-SAFETY.com.tw
Total Page : 2/20
Report No. : GO1404290504
www.GO-SAFETY.com.tw
Total Page : 3/20
TEST REPORT The Optical Report For Solid-State Lighting Products Report Number. ....................... :
GO1404290504
Date of test ................................. :
January 28, 2014
Date of issue .............................. :
May 13, 2014
Tested by (printed name and signature) …..: Reported by (printed name and signature)…..: Approved by (printed name and signature) …..:
Tim Liu
Tim Liu
Tim Liu
Tim Liu
David Yuan
David Yuan
Testing Laboratory……………:
Great One Global Certification Co., Ltd.
Address…………………………:
9F-2, No. 120, Qiaohe Road., Zhonghe Dist., New Taipei City 235, Taiwan (R.O.C.)
Applicant’s name...................... :
EYE Lighting International of North America Inc.
Address ...................................... :
9150 Hendricks Road, Mentor, Ohio 44060 (U.S.A.)
Standard Used………………….:
IESNA LM-79-08, Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products
Test item description ................. : GL Series LED Luminaire Product Name .............................. : Model/Type reference………….: GL-X-100-40-7-W-U-XX Ratings ...................................... :
100 Vac to 277 Vac, 50/60 Hz, 100 W
Reported By :
Reviewed By :
Tim Liu Project Engineer
David Yuan Manager
1. The test results of this report relate only to the tested sample identified in this report. 2. This report shall not be reproduced, in full or in portion, except for having written approval from Great One Global Certification Co., Ltd. 3. The data in report cannot be used for advertisement, publication and promotion.
Report No. : GO1404290504
www.GO-SAFETY.com.tw
Total Page : 4/20
SUMMARY OF PHOTOMETRY TEST: 1. Test Method : The sample was tested according to the LM-79-2008. A Type C High Speed Mirror Type Goniophotometer was used to measure the intensity (candelas) at each angle of distribution for each sample. A Spectroradiometer and a Integrating Sphere were used to measure correlated color temperature, chromaticity coordinates, and the color rendering index for each sample. Chromaticity coordinates, correlated color temperature and color rendering index were calculated from the spectral radiant flux measurements taken at 5 nm intervals over the range of 380 to 780 nm.The calibration of the sphere photometer-spectroradiometer system is traceable to the National Institute of Standards and Technology. The ambient temperature shall be maintained at 25°C ± 1°C. Each sample was operated at input rated voltage in its designated orientation. Electrical measurements including voltage, current, and power were measured using the Yokogawa Power Analyzer. Deviation from Standard operating procedures – None.
2.Test item particulars : Tested lamp ....................................................... : continuous wave lamps
pulsed lamps
Tested lamp system ........................................... : LED Lamp cap .......................................................... : N/A Bulb .................................................................. : N/A Rated of the lamp .............................................. : 100 Vac to 277 Vac, 50/60 Hz, 100 W Temperature by measurement ............................ : 24.5 °C Humidity by measurement ................................ : 54.0 %
3.Description of EUT Setup : Operating Orientation ....................................... : The light source is considered as horizontal Light Source ..................................................... : LED Stabilization time.............................................. : 1 Hour
Report No. : GO1404290504
www.GO-SAFETY.com.tw
Total Page : 5/20
4. Photograph of EUT of Sample :
Report No. : GO1404290504
www.GO-SAFETY.com.tw
Total Page : 6/20
RESULTS (1) Input Voltage/Frequency:110.00 V ac / 60 Hz (2) Input Watt:100.26 W (3) Input Current:0.915 A (4) Total Luminous Flux Output : 10062.17 lm (5) Luminaire Efficacy:100.36 lm/W (6) Central Intensity (cd) : 3558.905 (7) Maximum Intensity(cd) : 4250.408 (8) PF: 0.996 (9) Beam angle: (C0-C180) 108.4 (C90-C270) 108.8 (10) Color Rendering Index (CRI): 72.8 (11) Correlated Color Temperature (CCT): 4006 K (12) THD at 120 Vac: V%: 0.10, A%: 6.96 (13) PF at 277 Vac: 0.959 (14) THD at 277 Vac: V%: 0.06, A%: 11.05
Measurement Results : See Appendix A for details.
Report No. : GO1404290504
www.GO-SAFETY.com.tw
Total Page : 7/20
Equipments List Equipment ID
Equipment Type
Cal. Date
Due Date
L201
Integrating Sphere
N/A
N/A
L202
Spetroradiometer
N/A
N/A
L203
AC Power Source
N/A
N/A
L204
Goniophotometer Photo Detector
N/A
N/A
L205
Goniophotometer System
N/A
N/A
L206
AC Power Source
N/A
N/A
L207
Power Meter
2013/12/13
2014/12/12
L244
Standard Light Source
2014/01/03
2015/01/02
L221
Luminous Intensity Lamp
2013/11/13
2014/11/12
L222
Report No. : GO1404290504
Power Meter
2013/10/11
www.GO-SAFETY.com.tw
2014/10/10
Range Used
V : Auto (0~300Vac) A : Auto (0~20A)
V : Auto (0~300Vac) A : Auto (0~20A)
Total Page : 8/20
Appendix A Great One Global Certification Co., Ltd. =========================================================================== Product: GL-X-100-40-7-W-U-XX Manufacturer: EYE Lighting International of North America Inc. Sample No.: 14012705-2 Date: 1-28-2014 Tested By: Tim Liu Reviewed By: David Yuan
Test Condition Temperature: 25.4°C Spectrum Range: 350-800 nm
RH: 55.0% Scan Step: 5 nm
Spectroradiometric Parameters 1.0 0.8 0.6 0.4 0.2 0
350
425
500
575
650
725
800
Spectral Distribution
SDCM:ANSI_LED_4000K x0=0.3818 y0=0.3797
Chromaticity Coordinates: x=0.3808 y=0.3789 u'=0.2245 v'=0.5026 Correlated Color Temperature: 4006 K
Dominant Wavelength: 577.0 nm(E)
Chromaticity Difference: +0.0009Duv
Purity: 0.2801
Color Ratio: Kr=36.8% Kg=56.3% Kb=6.9%
Peak Wavelength: 444.3 nm
Bandwidth: 22nm
Color Tolerance: 0.0 SDCM
Rendering Index: Ra=72.8
Radiant Flux: 32.506 W
R1=71
R2=78
R3=82
R4=74
R5=70
R6=68
R7=81
R9=-15
R10=47
R11=70
R12=45
R13=72
R14=89
R15=66
Report No. : GO1404290504
www.GO-SAFETY.com.tw
R8=58
Total Page : 9/20
Appendix A
EYE Lighting International of North America Inc. Zonal flux distribution table γ(°)
Average I(cd)
Zonal F(lm)
Sum F(lm)
Eff Flux(lm)
Eff Sum(lm)
0.0
3546.496
.000
.000
.000%
.000%
5.0
3574.351
85.128
85.128
.846%
.846%
10.0
3605.397
256.842
341.970
2.553%
3.399%
15.0
3678.050
432.049
774.019
4.294%
7.692%
20.0
3799.550
616.259
1390.278
6.125%
13.817%
25.0
3907.407
808.318
2198.596
8.033%
21.850%
30.0
3936.583
992.664
3191.260
9.865%
31.715%
35.0
3818.956
1142.057
4333.317
11.350%
43.065%
40.0
3535.780
1227.082
5560.399
12.195%
55.260%
45.0
3167.806
1241.223
6801.622
12.336%
67.596%
50.0
2674.481
1180.519
7982.142
11.732%
79.328%
55.0
1984.166
1012.945
8995.087
10.067%
89.395%
60.0
924.761
672.390
9667.478
6.682%
96.077%
65.0
214.483
276.953
9944.430
2.752%
98.830%
70.0
63.718
70.442
10014.870
.700%
99.530%
75.0
26.722
23.640
10038.510
.235%
99.765%
80.0
12.506
10.497
10049.010
.104%
99.869%
85.0
5.802
4.975
10053.980
.049%
99.919%
90.0
1.276
1.938
10055.920
.019%
99.938%
95.0
.524
.493
10056.410
.005%
99.943%
100.0
.543
.290
10056.700
.003%
99.946%
105.0
.625
.313
10057.020
.003%
99.949%
110.0
.706
.348
10057.360
.003%
99.952%
115.0
.830
.389
10057.750
.004%
99.956%
120.0
.922
.426
10058.180
.004%
99.960%
125.0
1.021
.449
10058.630
.004%
99.965%
130.0
1.113
.464
10059.090
.005%
99.969%
135.0
1.223
.472
10059.560
.005%
99.974%
140.0
1.294
.466
10060.030
.005%
99.979%
145.0
1.384
.447
10060.480
.004%
99.983%
150.0
1.421
.413
10060.890
.004%
99.987%
155.0
1.472
.366
10061.250
.004%
99.991%
160.0
1.569
.319
10061.570
.003%
99.994%
165.0
1.527
.255
10061.830
.003%
99.997%
170.0
1.600
.185
10062.010
.002%
99.998%
175.0
1.663
.117
10062.130
.001%
100.000%
180.0
1.681
.040
10062.170
.000%
100.000%
Equipment: HW-1015 Temperature(°C): 24.5
Report No. : GO1404290504
Date: 2014/1/28 Humidity(%): 54.0%
www.GO-SAFETY.com.tw
Operator: Tim Liu Distance(m): 8.90
Total Page : 10/20
Appendix A
EYE Lighting International of North America Inc. Zonal flux distribution table
ZONAL LUMEN SUMMARY Zone
Lumens
%Lamp
%Fixt
0-30
3191.3
31.7%
31.7%
0-40
5560.4
55.3%
55.3%
0-60
9667.5
96.1%
96.1%
0-90
10055.9
99.9%
99.9%
90-120
2.3
0.0%
0.0%
90-130
3.2
0.0%
0.0%
90-150
5.0
0.0%
0.0%
90-180
6.2
0.1%
0.1%
0-180
10062.2
100.0%
100.0%
ZONAL LUMEN SUMMARY
Equipment: HW-1015 Temperature(°C): 24.5
Report No. : GO1404290504
0-10
342.0
10-20
1048.3
20-30
1801.0
30-40
2369.1
40-50
2421.7
50-60
1685.3
60-70
347.4
70-80
34.1
80-90
6.9
90-100
0.8
100-110
0.7
110-120
0.8
120-130
0.9
130-140
0.9
140-150
0.9
150-160
0.7
160-170
0.4
170-180
0.1
Date: 2014/1/28 Humidity(%): 54.0%
www.GO-SAFETY.com.tw
Operator: Tim Liu Distance(m): 8.90
Total Page : 11/20
Appendix A
EYE Lighting International of North America Inc. Light Distribution Curve [Unit: cd]
±180°
-90°
90° 850.08 1700.16 2550.25 3400.33 4250.41 0°
4250.41 3400.33 2550.25 1700.16 850.08 0.00
-180°
-135°
-90°
-45°
0°
45°
90°
135°
180°
C0/C180: C90/C270: Equipment: HW-1015 Temperature(°C): 24.5
Report No. : GO1404290504
Date: 2014/1/28 Humidity(%): 54.0%
www.GO-SAFETY.com.tw
Operator: Tim Liu Distance(m): 8.90
Total Page : 12/20
Appendix A
EYE Lighting International of North America Inc. Lux distance Curve
1.0m 2.0m 3.0m 4.0m 5.0m 6.0m 7.0m 8.0m 9.0m 10.0m 11.0m 12.0m
3558.91lx 889.73lx 395.43lx 222.43lx 142.36lx 98.86lx 72.63lx 55.61lx 43.94lx 35.59lx 29.41lx 24.71lx
Height E
Equipment: HW-1015 Temperature(°C): 24.5
Report No. : GO1404290504
Date: 2014/1/28 Humidity(%): 54.0%
www.GO-SAFETY.com.tw
Operator: Tim Liu Distance(m): 8.90
Total Page : 13/20
Appendix A
EYE Lighting International of North America Inc. ISO-Intensity(V-H)
90°
Imax:4250.41cd
[Unit:cd]
75° 60° 45° 30° 15° 0° -15° -30° -45° -60° -75° -90° -90°
-75°
-60°
-45°
-30°
-15°
0°
15°
30°
45°
60°
75°
90°
(10%Imax) 424.635 (20%Imax) 849.269 (30%Imax) 1273.9 (40%Imax) 1698.54 (50%Imax) 2123.17 (60%Imax) 2547.81 (70%Imax) 2972.44 (80%Imax) 3397.08 (90%Imax) 3821.71 Equipment: HW-1015 Temperature(°C): 24.5
Report No. : GO1404290504
Date: 2014/1/28 Humidity(%): 54.0%
www.GO-SAFETY.com.tw
Operator: Tim Liu Distance(m): 8.90
Total Page : 14/20
Appendix A
EYE Lighting International of North America Inc. ISO illuminance diagram 1.7d/h
Imax:4250.41cd
[Unit:lx] H=9.0m
1.3
1.0
0.7
0.3
0.0
0.3
0.7
1.0
1.3
1.7d/h
1.7d/h
1.3
1.0
0.7
0.3
0.0
0.3
0.7
1.0
1.3
1.7d/h
(10%Emax) 4.389308 (20%Emax) 8.778617 (30%Emax) 13.1679 (40%Emax) 17.55728 (50%Emax) 21.94654 (60%Emax) 26.3358 (70%Emax) 30.72519 (80%Emax) 35.11444 (90%Emax) 39.50383
Equipment: HW-1015 Temperature(°C): 24.5
Report No. : GO1404290504
Date: 2014/1/28 Humidity(%): 54.0%
www.GO-SAFETY.com.tw
Operator: Tim Liu Distance(m): 8.90
Total Page : 15/20
Appendix A
EYE Lighting International of North America Inc. Intensity data(cd) C/γ(°) 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 110.0 120.0 130.0 140.0 150.0 160.0 170.0 180.0 190.0 200.0 210.0 220.0 230.0 240.0 250.0 260.0 270.0 280.0 290.0 300.0 310.0 320.0 330.0 340.0 350.0 360.0
0.0 3558.91 3573.96 3560.49 3562.87 3556.53 3554.15 3569.99 3547.02 3524.05 3509.80 3513.76 3521.68 3532.77 3549.40 3546.23 3543.86 3550.98 3560.49 3558.91 3573.96 3560.49 3562.87 3556.53 3554.15 3569.99 3547.02 3524.05 3509.80 3513.76 3521.68 3532.77 3549.40 3546.23 3543.86 3550.98 3560.49 3558.91
Equipment: HW-1015 Temperature(°C): 24.5
Report No. : GO1404290504
5.0 3590.59 3581.88 3573.16 3573.96 3569.20 3569.99 3592.97 3560.49 3540.69 3537.52 3544.65 3552.57 3562.07 3572.37 3572.37 3566.03 3573.16 3585.04 3585.84 3605.64 3593.76 3607.22 3603.26 3592.17 3601.68 3575.54 3547.02 3534.35 3545.44 3549.40 3569.99 3585.04 3583.46 3583.46 3594.55 3600.09 3590.59
10.0 3649.20 3621.48 3619.90 3600.89 3591.38 3590.59 3611.18 3581.08 3558.91 3552.57 3562.87 3577.12 3579.50 3587.42 3587.42 3585.84 3600.89 3615.94 3606.43 3650.00 3626.23 3626.23 3628.61 3618.31 3624.65 3622.27 3588.21 3586.63 3586.63 3591.38 3601.68 3612.77 3611.98 3637.32 3646.83 3653.96 3649.20
15.0 3753.76 3688.02 3663.46 3665.05 3642.87 3635.74 3653.96 3623.86 3620.69 3615.94 3615.94 3615.14 3623.07 3632.57 3642.08 3635.74 3657.92 3680.89 3671.38 3726.04 3703.86 3699.11 3699.90 3712.57 3720.49 3726.83 3697.52 3697.52 3693.56 3695.15 3701.48 3695.94 3697.52 3724.45 3730.00 3749.80 3753.76
20.0 3861.49 3790.99 3769.60 3751.39 3741.88 3745.05 3792.57 3775.94 3763.27 3764.06 3751.39 3745.84 3743.46 3741.88 3740.30 3727.62 3748.22 3775.15 3765.64 3821.09 3803.66 3820.30 3849.61 3868.62 3855.15 3855.94 3821.88 3820.30 3815.55 3826.64 3841.69 3857.53 3848.02 3860.70 3853.57 3867.82 3861.49
25.0 3884.46 3875.75 3876.54 3890.80 3927.23 3941.49 3920.90 3858.32 3822.67 3814.75 3824.26 3844.85 3902.68 3935.94 3890.00 3839.31 3832.97 3840.10 3825.84 3829.80 3865.45 3974.76 4063.47 4055.55 3967.63 3919.31 3870.20 3865.45 3870.20 3916.93 3994.56 4085.65 4053.18 3984.26 3910.60 3890.80 3884.46
Date: 2014/1/28 Humidity(%): 54.0%
www.GO-SAFETY.com.tw
30.0 3769.60 3859.11 3917.73 4046.05 4139.51 4097.53 3961.29 3852.77 3769.60 3775.15 3798.91 3886.04 4026.24 4139.51 4076.94 3912.97 3816.34 3779.11 3771.98 3746.63 3848.81 4063.47 4204.47 4186.25 4000.90 3856.73 3780.69 3761.68 3799.70 3920.90 4099.91 4250.41 4183.87 4001.69 3840.89 3773.56 3769.60
35.0 3523.26 3698.31 3818.71 4055.55 4202.09 4115.75 3889.21 3711.78 3596.93 3607.22 3658.71 3794.16 4020.70 4174.37 4093.57 3861.49 3684.06 3611.18 3612.77 3521.68 3699.90 3958.12 4138.72 4082.48 3861.49 3643.66 3547.82 3530.39 3604.06 3771.19 4052.38 4204.47 4107.83 3856.73 3631.78 3539.90 3523.26
40.0 3220.68 3393.36 3586.63 3840.89 3966.84 3867.03 3650.79 3420.29 3291.18 3272.17 3348.21 3544.65 3796.54 3914.56 3851.98 3641.28 3409.20 3329.20 3343.45 3225.43 3446.43 3703.86 3762.48 3753.76 3597.72 3345.83 3231.77 3196.92 3302.26 3509.80 3769.60 3839.31 3765.64 3583.46 3342.66 3222.26 3220.68
Operator: Tim Liu Distance(m): 8.90
Total Page : 16/20
Appendix A
EYE Lighting International of North America Inc. Intensity data(cd) C/γ(°) 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 110.0 120.0 130.0 140.0 150.0 160.0 170.0 180.0 190.0 200.0 210.0 220.0 230.0 240.0 250.0 260.0 270.0 280.0 290.0 300.0 310.0 320.0 330.0 340.0 350.0 360.0
45.0 2842.06 3074.93 3307.02 3488.41 3564.45 3445.64 3306.23 3081.27 2921.27 2917.30 2998.89 3219.89 3432.96 3493.16 3444.84 3345.83 3115.33 2986.22 2996.51 2881.66 3097.11 3254.74 3348.21 3316.52 3212.76 2995.72 2887.20 2817.50 2933.94 3171.57 3318.90 3411.57 3334.74 3220.68 2971.96 2884.04 2842.06
Equipment: HW-1015 Temperature(°C): 24.5
Report No. : GO1404290504
50.0 2306.60 2659.87 2872.95 2929.98 3089.19 2963.25 2805.62 2650.37 2487.99 2483.23 2575.91 2738.29 2849.18 3027.41 2962.45 2837.30 2686.80 2546.60 2514.92 2365.21 2526.80 2678.09 2841.26 2794.53 2648.78 2579.87 2377.88 2358.87 2502.24 2636.90 2752.55 2903.05 2843.64 2636.90 2492.74 2354.12 2306.60
55.0 1465.62 2038.87 2225.01 2324.81 2520.46 2374.72 2190.16 2053.12 1811.53 1817.87 1929.56 2121.24 2303.43 2471.35 2381.84 2192.53 2040.45 1834.50 1850.35 1504.83 1554.18 2070.55 2270.95 2247.19 1962.82 1577.94 1528.91 1490.89 1572.08 1941.44 2160.06 2326.40 2236.89 1981.83 1577.63 1477.98 1465.62
60.0 271.77 730.32 1108.15 1524.00 1833.71 1687.97 1217.46 755.66 560.81 578.23 704.18 1032.90 1551.72 1858.27 1645.19 1223.79 786.56 562.39 574.27 301.47 513.60 1077.41 1559.41 1339.60 796.38 337.91 296.48 305.28 362.70 637.80 1177.22 1558.85 1352.27 813.25 339.97 314.46 271.77
65.0 150.90 118.74 125.94 425.36 773.88 458.63 151.53 73.19 153.27 150.97 105.43 94.10 428.53 788.93 454.67 168.32 78.73 165.63 157.23 92.04 59.41 148.28 387.50 206.82 109.55 54.81 154.46 149.31 102.02 63.29 138.22 460.92 239.14 112.64 63.13 155.89 150.90
70.0 87.21 63.84 40.71 64.24 65.03 69.86 60.52 44.44 104.95 112.87 61.94 35.72 59.57 54.10 68.68 65.11 47.13 120.00 116.91 55.05 34.85 53.94 38.97 65.59 48.71 45.86 79.84 80.08 54.65 34.77 57.11 45.78 60.20 58.22 45.31 92.04 87.21
Date: 2014/1/28 Humidity(%): 54.0%
www.GO-SAFETY.com.tw
75.0 29.70 31.21 25.90 30.97 24.71 37.31 22.26 31.29 30.50 32.48 28.99 24.48 28.99 24.56 33.82 25.74 32.48 34.22 37.39 23.68 19.56 19.25 21.70 21.94 19.33 24.71 24.40 27.25 25.19 22.65 21.07 24.24 27.72 19.96 24.71 27.64 29.70
80.0 12.67 14.81 12.75 11.96 13.54 11.80 11.33 12.36 12.67 12.52 12.36 11.09 11.41 13.47 12.52 12.44 13.94 14.81 14.97 12.59 11.49 11.01 12.75 11.01 11.09 11.80 12.83 12.20 13.15 11.72 11.25 13.70 12.75 11.88 12.44 13.15 12.67
85.0 4.99 6.57 6.73 6.42 6.50 5.78 5.47 5.15 4.91 4.83 5.15 4.99 5.70 6.57 6.50 6.50 6.73 6.81 6.65 5.54 5.54 5.78 5.62 5.54 5.47 5.70 5.15 4.99 5.39 5.62 5.54 6.57 6.50 5.94 5.70 5.31 4.99
Operator: Tim Liu Distance(m): 8.90
Total Page : 17/20
Appendix A
EYE Lighting International of North America Inc. Intensity data(cd) C/γ(°) 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 110.0 120.0 130.0 140.0 150.0 160.0 170.0 180.0 190.0 200.0 210.0 220.0 230.0 240.0 250.0 260.0 270.0 280.0 290.0 300.0 310.0 320.0 330.0 340.0 350.0 360.0
90.0 0.95 1.50 1.66 1.58 1.50 1.43 1.19 1.11 1.11 1.03 1.11 1.11 1.43 1.66 1.66 1.50 1.66 1.66 1.82 1.03 1.11 0.87 1.27 1.03 1.35 1.19 1.19 1.19 1.27 1.19 1.03 1.11 1.19 1.19 1.11 0.95 0.95
Equipment: HW-1015 Temperature(°C): 24.5
Report No. : GO1404290504
95.0 0.48 0.55 0.55 0.63 0.48 0.55 0.48 0.63 0.63 0.55 0.63 0.55 0.63 0.63 0.48 0.48 0.63 0.48 0.55 0.48 0.48 0.48 0.48 0.48 0.40 0.55 0.48 0.48 0.48 0.48 0.48 0.48 0.55 0.48 0.48 0.55 0.48
100.0 0.55 0.63 0.55 0.55 0.63 0.55 0.55 0.55 0.63 0.71 0.55 0.63 0.63 0.55 0.55 0.55 0.55 0.63 0.55 0.55 0.40 0.48 0.55 0.48 0.55 0.55 0.48 0.48 0.48 0.48 0.63 0.48 0.48 0.40 0.48 0.48 0.55
105.0 0.48 0.71 0.71 0.71 0.71 0.71 0.63 0.71 0.63 0.63 0.63 0.71 0.79 0.71 0.71 0.71 0.55 0.63 0.55 0.63 0.55 0.63 0.63 0.71 0.55 0.55 0.63 0.48 0.48 0.48 0.55 0.63 0.63 0.63 0.55 0.48 0.48
110.0 0.71 0.71 0.71 0.71 0.79 0.79 0.79 0.71 0.63 0.71 0.71 0.71 0.87 0.87 0.79 0.79 0.63 0.71 0.63 0.63 0.63 0.71 0.71 0.79 0.71 0.55 0.71 0.55 0.63 0.63 0.79 0.71 0.63 0.63 0.71 0.63 0.71
115.0 0.71 0.79 0.87 0.87 1.03 0.95 0.87 0.79 0.79 0.79 0.87 0.95 0.87 1.03 0.87 0.79 0.87 0.79 0.87 0.79 0.87 0.87 0.87 0.71 0.79 0.79 0.71 0.71 0.71 0.71 0.87 0.79 0.95 0.79 0.79 0.71 0.71
Date: 2014/1/28 Humidity(%): 54.0%
www.GO-SAFETY.com.tw
120.0 0.87 0.87 0.95 1.03 1.03 0.95 0.95 0.95 0.87 1.03 0.95 1.03 1.03 1.03 1.03 0.95 0.87 0.95 1.03 0.87 0.95 0.87 1.03 0.95 0.87 0.87 0.79 0.79 0.87 0.87 0.79 0.95 0.87 0.87 0.79 0.79 0.87
125.0 0.79 1.11 1.03 1.27 1.19 1.19 1.03 1.11 1.03 1.03 1.11 0.95 1.11 1.11 1.11 1.11 1.19 1.11 1.03 0.87 0.87 1.03 1.11 1.03 0.95 0.95 0.79 0.87 0.95 0.87 0.95 1.03 0.95 1.03 0.95 0.95 0.79
130.0 0.95 1.19 1.11 1.19 1.19 1.19 1.19 1.03 1.19 1.11 1.11 1.27 1.27 1.27 1.27 1.19 1.27 1.19 1.11 1.03 1.03 0.95 1.11 1.03 1.03 1.03 0.95 1.11 1.03 0.95 1.11 1.11 1.19 1.11 1.03 1.03 0.95
Operator: Tim Liu Distance(m): 8.90
Total Page : 18/20
Appendix A
EYE Lighting International of North America Inc. Intensity data(cd) C/γ(°) 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 110.0 120.0 130.0 140.0 150.0 160.0 170.0 180.0 190.0 200.0 210.0 220.0 230.0 240.0 250.0 260.0 270.0 280.0 290.0 300.0 310.0 320.0 330.0 340.0 350.0 360.0
135.0 1.03 1.27 1.35 1.35 1.43 1.35 1.43 1.35 1.27 1.27 1.27 1.43 1.43 1.27 1.35 1.27 1.27 1.27 1.19 1.19 1.11 1.27 1.19 1.19 1.11 1.19 1.11 1.03 0.95 1.03 1.19 1.19 1.19 1.19 1.11 1.03 1.03
Equipment: HW-1015 Temperature(°C): 24.5
Report No. : GO1404290504
140.0 1.11 1.58 1.50 1.50 1.43 1.43 1.35 1.43 1.35 1.43 1.43 1.35 1.50 1.43 1.43 1.43 1.35 1.35 1.50 1.11 1.11 1.27 1.19 1.11 1.19 1.19 1.19 1.11 1.11 1.11 1.11 1.19 1.19 1.19 1.19 1.19 1.11
145.0 1.19 1.58 1.58 1.58 1.50 1.50 1.43 1.43 1.50 1.58 1.58 1.50 1.50 1.58 1.50 1.50 1.58 1.58 1.66 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.19 1.11 1.11 1.27 1.35 1.11 1.19 1.27 1.27 1.19 1.19
150.0 1.27 1.66 1.66 1.58 1.58 1.58 1.50 1.43 1.43 1.58 1.66 1.66 1.58 1.50 1.50 1.58 1.58 1.58 1.74 1.19 1.19 1.27 1.35 1.27 1.27 1.27 1.19 1.35 1.19 1.19 1.27 1.35 1.27 1.35 1.27 1.27 1.27
155.0 1.19 1.74 1.74 1.66 1.66 1.58 1.50 1.66 1.50 1.58 1.58 1.58 1.66 1.66 1.66 1.66 1.66 1.66 1.74 1.35 1.43 1.35 1.35 1.35 1.27 1.27 1.27 1.27 1.19 1.19 1.27 1.27 1.43 1.27 1.43 1.35 1.19
160.0 1.43 1.82 1.82 1.90 1.74 1.74 1.66 1.74 1.74 1.74 1.74 1.74 1.66 1.82 1.74 1.74 1.74 1.82 1.74 1.43 1.43 1.43 1.27 1.43 1.43 1.27 1.27 1.35 1.27 1.43 1.27 1.50 1.35 1.35 1.43 1.50 1.43
Date: 2014/1/28 Humidity(%): 54.0%
www.GO-SAFETY.com.tw
165.0 1.43 1.66 1.58 1.66 1.58 1.74 1.58 1.66 1.66 1.66 1.66 1.66 1.58 1.66 1.74 1.66 1.82 1.66 1.66 1.58 1.35 1.35 1.43 1.35 1.27 1.35 1.43 1.35 1.27 1.35 1.43 1.43 1.50 1.43 1.35 1.43 1.43
170.0 1.58 1.74 1.66 1.74 1.74 1.66 1.58 1.66 1.58 1.74 1.66 1.74 1.66 1.66 1.74 1.66 1.74 1.82 1.74 1.50 1.50 1.58 1.35 1.50 1.43 1.35 1.43 1.43 1.43 1.50 1.50 1.58 1.66 1.66 1.50 1.50 1.58
175.0 1.66 1.74 1.74 1.74 1.74 1.66 1.66 1.58 1.58 1.66 1.66 1.66 1.66 1.66 1.74 1.74 1.82 1.74 1.74 1.66 1.66 1.58 1.66 1.58 1.50 1.58 1.66 1.66 1.58 1.58 1.66 1.58 1.66 1.66 1.66 1.66 1.66
Operator: Tim Liu Distance(m): 8.90
Total Page : 19/20
Appendix A
EYE Lighting International of North America Inc. Intensity data(cd) C/γ(°) 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 110.0 120.0 130.0 140.0 150.0 160.0 170.0 180.0 190.0 200.0 210.0 220.0 230.0 240.0 250.0 260.0 270.0 280.0 290.0 300.0 310.0 320.0 330.0 340.0 350.0 360.0
180.0 1.74 1.66 1.66 1.74 1.74 1.66 1.66 1.66 1.58 1.66 1.58 1.66 1.66 1.66 1.74 1.66 1.74 1.74 1.74 1.66 1.66 1.74 1.74 1.66 1.66 1.66 1.58 1.66 1.58 1.66 1.66 1.66 1.74 1.66 1.74 1.74 1.74
Equipment: HW-1015 Temperature(°C): 24.5
Report No. : GO1404290504
Date: 2014/1/28 Humidity(%): 54.0%
www.GO-SAFETY.com.tw
Operator: Tim Liu Distance(m): 8.90
Total Page : 20/20