CorePro LEDspot MV CorePro LEDspot 4-35W GU10 827 36D DIM CorePro LEDspots are a perfect fit for spot lighting and deliver warm halogen-like light. They are compatible with most existing fixtures with a GU10 and are designed as a retrofit replacement for halogen or incandescent spots. CorePro LEDspots deliver significant energy savings and minimize maintenance cost.
Product data Operating and Electrical
General Information Cap-Base
GU10 [ GU10]
Input Frequency
50 to 60 Hz
Nominal Lifetime (Nom)
15000 h
Power (Rated) (Nom)
4W
Switching Cycle
50000X
Lamp Current (Nom)
19 mA
Technical Type
4-35W
Wattage Equivalent
35 W
Starting Time (Nom)
0.5 s
Warm Up Time To 60% Light (Nom)
0.5 s
Light Technical Color Code
827 [ CCT of 2700K]
Power Factor (Nom)
0.7
Beam Angle (Nom)
36 °
Voltage (Nom)
220-240 V
Luminous Flux (Nom)
250 lm
Luminous Flux (Rated) (Nom)
250 lm
Temperature
Luminous Intensity (Nom)
540 cd
T-Case Maximum (Nom)
Color Designation
Warm White (WW)
Rated Beam Angle
36 °
Controls and Dimming
Correlated Color Temperature (Nom)
2700 K
Dimmable
Luminous Efficacy (rated) (Nom)
62.50 lm/W
Color Consistency
<6
Approval and Application
Color Rendering Index (Nom)
80
Suitable For Accent Lighting
Yes
LLMF At End Of Nominal Lifetime (Nom)
70 %
Energy Efficiency Label (EEL)
A+
Luminous Flux In 90° Cone (Rated)
250 lm
Energy Consumption kWh/1000 h
4 kWh
Datasheet, 2017, August 22
85 °C
Yes
data subject to change
CorePro LEDspot MV
Product Data
Numerator - Packs per outer box
10
Full product code
871869672133900
Material Nr. (12NC)
929001363802
Order product name
CorePro LEDspot 4-35W GU10 827 36D DIM
Net Weight (Piece)
0.038 kg
EAN/UPC - Product
8718696721339
Order code
929001363802
Numerator - Quantity Per Pack
1
Dimensional drawing Product
D
C
CorePro LEDspot 4-35W GU10 827 36D DIM
50 mm
54 mm
C
D
GU10 230V 4-35W 250lm 36D 2700K GU10 D
Photometric data 100
Accent Lighting - Spots
1 x 280lm 120
Cartesian intensity diagram
o
(cd)
80
180
Beam diagram
750 o
1
0-180
90o
90-270
60
o
2.0 300
450
150
γ 30
750 0-180o
0
-60o
-40o
E0 (lx)
-20o
0o
20o
40o
60o γ
567
d(m) VBA
1
1
/2Imax /2E0 0.55 0.83
0.50
1.5
252
2.0
142
1.11
1.00
2.5
91
1.39
1.25
0.75
3.0
3.0 3.5
46
1.94
1.75
4.0
4.0
35
2.22
2.00
4.5
28
2.50
2.24
o
0o
(cd)
h (m) 1.0
450
300
30o
15o,16o
600 1.0
150 60o
600
/2Imax
h(m)
o
90o
5.0 3.0
2.0
1.0
0.0
1.0
2.0
63
1.66
1.50
3.0 (m)
90-270o
Visual impact diagram Light output ratio Service upward Service downward
60
0.98 0.00 0.98
Accent factor
Intensity (%)
1 x GU10 4W 2700K 36D 9290013638
Polar intensityo diagram o
120
Imax
540 cd
100
BS (1/2Imax) BS (1/2E0)
15o,16o 13o,15o
50 30 15 10
1m
5
2m
3m 2 4m
25
50
100
250 500 1000 Eh(lx)
SL20593
2016-01-06
40 20 0 200
300
400
500
600
700
800 [nm]
CalcuLuX Photometrics 4.5
Philips Lighting B.V.
Page: 1/1
© 2017 Philips Lighting Holding B.V. All rights reserved. Philips Lighting reserves the right to make changes in specifications and/or to discontinue any product at any timewithout notice or obligation and will not be liable for any consequences resulting
www.lighting.philips.com
from the use of this publication.
2017, August 22 - data subject to change