Transcript
M23x1
170
155
Power Source
DB400 / DB425
DOLPHIN PANEL MOUNTED ELECTRONIC INFRARED TAP › WRAS Approved product › Touch Free Tap – for ultimate hygiene – prevents cross contamination › Quality polished or brushed chrome plated brass finishes available from stock – other finishes available to special order › Water Supply: Single inlet cold or pre-mixed – a TMV2 or TMV3 thermostatic mixing valve is recommended for premixed applications › Flow rate – 3.8 litres/minute with our standard fitted flow regulator at any pressure between 0 and 6 bar (other flow rates such as 1.89 and 1.33 LPM available to special order – please enquire)
DIAMETER PROJECTION
50
MM
170
MM
› Power Source: 6 x AA Battery / plug in 9v Transformer › Power Connections: tap female, power source male › Operating pressure 0.5 - 8.0 bar (7 - 116 PSI) › Maximum water temperature 70ºC
› Flow time once user's hands are removed from the tap - 1 second (adjustable by using remove control DB51) › Interchangeable STD M22/24 Neoperl Aerator insert › Tap settings may be adjusted by using remote control (DB51) › Mandatory Hygiene Flush feature can be specified to combat Legionella
PRODUCT CODES BATTERY POWERED › Polished Chrome › Brushed/ Satin Chrome
DB400C DB400S-2
› 2 year manufacturer’s warranty TRANSFORMER POWERED
› Complies with SKA rating criteria
› Polished Chrome
› To special order we can supply a threaded tail extension kit
› Brushed/Satin Chrome
DB425C DB425S-2
› Our low flow taps are fully BREEAM compliant and contribute to up to five BREEAM WAT 1 credits. › Listed on the Government's Water Technology List (WTL) as part of the Enhanced Capital Allowance (ECA) scheme. This allows businesses purchasing these product to benefit from 100% first year capital allowances on this expenditure.
TECHNIC AL HELPLINE 01424 202224 DOLPHINSOLUTIONS.CO.UK
Ø50
M23x1
170
Ø38
155
550 MAX
52
Power Source
BELL-CHEM PRODUCTS COMPANY DOLPHIN BLUE PANEL MOUNTED ELECTRONIC INFRARED TAP DB400 / DB425
DB400 Dolphin Blue Panel Mounted Electronic Infrared Tap Spare parts can be obtained only by ordering the relevant kit. Spare parts cannot be ordered individually. In order to locate the relevant spare part, please check the corresponding part and part number at the drawing at the last page. When ordering spare parts (kits) please mention the corresponding catalog number (Cat. No.).
Quantity
Part Number Description
Cat. No.
-
Seals and Screws Kit
DB 07210015
1
2
O-ring
DB 04510193
1
5
O-ring
DB 04510078
1
4
O-Ring
DB 04510297
1
3
Screw
DB 05010405
1
6
Screw
DB 05010316
-
Self Adaptive Sensor Kit
DB 07220239
1
1
Self Adaptive Sensor
DB 08002325
1
2
O-ring
DB 04510193
-
Solenoid BS-Housing Kit/
DB 07231008/
Solenoid BS-Housing Kit USA
DB 07231009
1
7
Solenoid valve’s body
DB 07502019
1
8
Filter
DB 08530013
1
9
Nipple
DB 07025015/ DB 07025078
-
Solenoid Valve Kit
DB 07230017
1
11
Solenoid valve
DB 07500025
1
10
Diaphragm
DB 04500001
10
Diaphragm
DB 04500001
Haywood Way, Ivyhouse Ind Est, Hastings, TN35 4PL
[email protected] www.dolphindispensers.co.uk
DOLPHIN
Southpoint, Compass Park, Bodiam, Robertsbridge TN32 5BS
[email protected] www.dolphindispensers.co.uk
DOLPHIN
INSTALLATION AND MAINTENANCE GUIDE
Dolphin Blue Infrared Taps Saving water and energy promoting hygiene Panel mounted electronic tap for cold or premixed water
DB/L/XL 400 DB/L/XL 425 DB 450/475
Important: Read carefully before installing product
DOLPHIN Revision March 2013
CONTENTS
3
Technical Data
4-5
Pack Contents
6
Pre-Installation Information
7
Pre-Installation
8 - 10
Tap Installation DB/L/XL 400 + 425
11-13
Tap Installation DB 450 + 475
14-16
Setting Adjustment
17
Battery Replacement To replace the battery of DB/L/XL 400 + 450 models
18
Maintenance Filters cleaning instructions Care and cleaning of chrome and special finshes
19
Spare Parts List Limited Warranty
20
Trouble Shooting
2 | Dolphin Blue | 400 Series
TECHNICAL DATA
Wall mounted electronic tap for cold or premixed water Power Supply Battery a.
6x1.5AA battery (DB/L/XL 400 models)
Battery b.
1x9V (PP3) battery (model DB 450)
Transformer
9v transformer (DB/L/XL 425 + DB 475 models)
Recommended
0.5-8.0 bar (7-116 PSI)
Water Pressure
With water pressure of more than 8 bars use a pressure reducing valve
Sensor range
Self adjusting sensor. Adjustable with remote control
Minimum sensor range
80mm
Maximum sensor range
300mm
Security time
90 seconds. Can be changed with the DB50 remote control
Hot water temperature
Max 70ºC
400 Series | Dolphin Blue | 3
PACK CONTENTS DB/L/XL 400 DB/L/XL 425 1 x Spout and attachment (inc electronic unit)
1 x Wall rosette
1 x Tap base 1 x M4x6 screw
1 x Allen key
1 x Solenoid housing kit with filter adaptor
DB/L/XL 400
4 | Dolphin Blue | 400 Series
DB/L/XL 425
PACK CONTENTS DB 450 DB 475 1 x Spout and attachment (inc electronic unit) 1 x base with support
3 x screws (6 x 11/2") 1 x wall rosette
1 x Allen key
DB 450
DB 475
4 x screws
1 x panel
1 x temporary protective cover Required (not supplied) rigid pipe, cable sleeves
400 Series | Dolphin Blue | 5
PRE INSTALLATION INFORMATION
Check Contents Separate all parts from the packaging and check you have each part according to the pack contents section, pages 4-6. Pay attention to the variations of the different models. Make sure all parts are accounted for before discarding any packaging material. If any parts are missing, do not attempt to install your electronic tap. Please call 0800 0723 404 immediately to notify us. Warning 1) To avoid reflection problems keep a distance of more than 300 mm. between the sink and the spout. 2) This tap model, with an infrared sensor pointing down, is not intended to be used together with a sink of a reflective material such as stainless steel. 3) If a sink strainer is straight below the tap sensor, use a strainer with a non reflective finish (do not use a chrome plated one).
Preparation for installation Flush water supply lines thoroughly before installing the tap. Do not allow dirt, Teflon tape or metal particles to enter the tap. Shut off water supply.
Important All plumbing is to be installed in accordance with applicable codes and regulations.
6 | Dolphin Blue | 400 Series
PRE INSTALLATION
Warning ● To
avoid reflection problems it is recommended to keep a distance of more
than 300mm between the sink and the spout. If the distance is below 300mm a simple mock-up should be effected to confirm the tap functions as desired in your application before final installation. You may require a Dolphin Blue remote control to adjust the range. ● Do
not connect water or power supplies or remove the black label
covering the infra-red sensor until you have read and understood these instructions. Please see page 13. ● It
is not recommended to use DB400 series with a polished stainless steel
sink. For this type of application a separate panel-mounted sensor should be used – please speak to our technical sales team. ● Please
observe the guide to minimum cavity depths as shown in the table.
This is important because the water supply hose must not be kinked due to lack of space. Please note we have provided this information as a guide and cannot be held responsible for fundamental design errors. If your situation differs to those shown below please call us on 0800 0723 404, and we will provide you with a solution. Panel thickness (A)
B
A
Minimum void (B)
10-15mm
80mm
16-25mm
70mm
26-35mm
60mm
400 Series | Dolphin Blue | 7
TAP INSTALLATION
Installation instructions for DB/L/XL 400 + DB/L/XL 425 Step 1 – Installing the tap 1. Shut off the water supply 2. Drill a hole (23 to 24 mm) at the place where you want to install the spout of the tap. 3. If your model includes an optional anti-rotation pin, drill a small hole just above the previous one for the anti-rotation pin.
M3 14.4
M23x1 51.0
4. Insert the tap and its attachments through the wall. The aerator at the tap spout must face the washbasin. 5. Insert the anti-rotation pin into the small hole (if needed) 6. Fix the base behind the wall with the hexagonal nut and the disk.
8 | Dolphin Blue | 400 Series
TAP INSTALLATION
Step 2 – Connecting the Water Supply 1. Fit the flexible pipe coming from the Tap base to the
Water inlet
solenoid valve housing. 2. Fit the water supply inlet to the adapter at the solenoid valve housing. Inlet and outlet should follow the indicating arrow at the solenoid housing. Filter
Note: Make sure the filter is located at the solenoid inlet.
Water inlet
3. Connect the cable coming from the electronic unit to the solenoid valve. Important: Tap was supplied with a Self Adjusting Sensor. The ideal sensor range for the specific location will be set automatically.
Before proceeding to step 3 check that
Now, remove the protecting
no objects are in front of the sensor
sticker that covers the sensor.
besides the washbasin.
400 Series | Dolphin Blue | 9
TAP INSTALLATION
Step 3 – Connecting the Power Source 1a. For DB/L/XL 400: Connect the other cable coming from the electronic unit at the Tap base to the battery box. 1b. For DB/L/XL 425: Connect the other cable coming from the electronic unit at the Tap base to the transformer. Plug the transformer into the electricity socket. 2. After you have connected the power source (Battery or Transformer) wait 15 seconds in order to allow the system to set the ideal sensor range. As an indication that the self adjusting is taking place, a red light in the sensor eye will flash continuously. The solenoid valve will be opened and closed for 1 second as an indication that the ideal sensor range was set and the product is ready for use. 3. Turn on the central water supply. Check for leaks. Note: This tap includes a special aerator that allows you to adjust the water stream direction on site in order to prevent water splashing if needed. To change the angle of the water stream, simply move the adjustable tilting plate by pressing it smoothly. 4. If the automatically adjusted sensor range is not satisfactory, please refer to the section entitled “Settings adjustment”.’.
10 | Dolphin Blue | 400 Series
TAP INSTALLATION
Installation instructions for DB450 and DB 475 Step 1 – Installing the Tap 1. Shut off the water supply 2. Cut an adequate opening in the wall according to the dimensions of the tap box, the cables sleeve, the rigid pipe and the tap base with the support (at the place where you want to install the spout). 3. Cut two small holes for the tap base support and drive the anchors in. 4. Insert the tap box through the wall. Connect the water supply pipe to the nipple at the bottom of the tap box. 5. Mount the tap base with the support through the wall opening, and secure the base support to the two small holes using 2 screws. Important: The tap base should be installed so that the outside surface of the finished wall falls between the minimum and maximum lines marked at the base. 6. Assemble the rigid pipe from the nipple at the box to the inlet at the tap base. 7. Pull the wires of the power supply (transformer/battery) and sensor cable out of the tap base. 8. Lead the wires through the cable sleeve. 9. Connect the electronic unit’s connector coming from the tap base to the solenoid’s connector.
400 Series | Dolphin Blue | 11
TAP INSTALLATION
10.If your model is DB 475, connect the power supply connector from the electronic unit coming from the tap base to the transformer. 11.Assemble the temporary protective cover panel to the tap box. 12.Once the works on electricity, plumbing and tiles have been finished, insert the wall rosette through the tap base. 13.Connect the cable leading to the solenoid and the power supply cable at the spout to those at the tap base. Fix the tap spout by inserting the nipple into the tap base. Make sure that this area is clean before proceeding. Secure the screw with the Allen key. Make sure that the aerator at the tap spout will be installed facing the washbasin.
Step 2 – Connecting the power source 1. Remove the temporary protective cover panel. Important: tap was supplied with A Self Adjusting Sensor. The ideal sensor range for the specific location will be set automatically. Right now, check that no objects are in front of the sensor besides the washbasin. 2. Now remove the protecting sticker that covers the sensor. 3. If your model is DB 450 the battery box is attached to the cover panel. Connect the battery box connector to the electronic unit connector. 4. If your model is DB 475, plug the transformer into the electricity socket.
12 | Dolphin Blue | 400 Series
TAP INSTALLATION
5. After you have connected the power source (Battery or Transformer) wait 15 seconds in order to allow the system to set the ideal sensor range. As an indication that the self adjusting is taking place, a red light in the sensor eye will flash continuously. The solenoid valve will be opened and closed for 1 second as an indication that the ideal sensor range was set and the product is ready for use.
Step 3 - Connecting the water supply 1. Turn on the central water supply. 2. Check for leaks. 3. Assemble the wall cover panel by screwing the four screws. Note: This tap includes a special aerator that allows you to adjust the water stream direction on site in order to prevent water splashing. To change the angle of the water stream, simply move the adjustable tilting plate by pressing it smoothly. 4. If the automatically adjusted sensor range is not satisfactory, please refer to the section entitled “Settings adjustment”.
400 Series | Dolphin Blue | 13
SETTING ADJUSTMENT
Detection Range
Delay Out Time
Delay In Time
Temporary Off Function
Entrance to the Self Adjustment Mode
Reset
Lock Out Time
24 Hour Hygiene Flush
Adjusting the settings with the remote control If necessary, the sensor settings can be adjusted as following: Shut off the water supply. In order to adjust the sensor with the remote control, hold the remote control straight in front of the sensor in a distance of about 6-8” (15-20cm). Choose the function you want to adjust by pressing once on one of the function buttons. After pressing once on a specific function button, a quick flashing of the red light at the front of the sensor will occur. At this stage, you can change the setting by pressing the (+) or the (-) buttons, every push will increase or decrease one level. After finishing the adjustment, turn the water supply back on.
14 | Dolphin Blue | 400 Series
SETTING ADJUSTMENT DETECTION RANGE: This tap was supplied with a Self Adjusting Sensor. The ideal detection range for the specific location will be set automatically. Only if necessary, use the remote control to adjust the sensor range as follows: Press the RANGE button. Wait until a quick flashing of the red light of the sensor eye is perceived. Then, press + to increase the delay out time and – to reduce it every push will increase or decrease one level. Note: Once you have changed the detection range with the remote control, this distance will be remembered by the sensor, even if the power source is disconnected. To get back to the self adjustment mode, use the ADJ button only.
ENTRANCE TO THE SELF ADJUSTMENT MODE: Check that no objects are in front of the sensor. Press the ADJ button. Once a quick flashing of the red light of the sensor eye is perceived, remove your hand holding the remote control and move away from the sensor area. The ideal sensor range for the specific location will be set automatically. Once the self adjustment has taken place the solenoid valve will be opened and closed for 1 second as an indication that the ideal sensor range was set and the product is ready for use. SECURITY TIME: The Security time, prevents continuous running of water due to reflections or vandalism. By default, if the sensor is covered for more than 90 seconds the water flow will shut automatically. To resume regular operation any obstruction must be removed. Press the SEC button. Wait until a quick flashing of the red light of the sensor eye is perceived. Then, press + to increase the security time and – to reduce it.
400 Series | Dolphin Blue | 15
SETTING ADJUSTMENT DELAY IN TIME: It is recommended to change the delay in time for flush valves for urinals or toilets only. If required, the delay in time can also be modified in taps as follows: Press the IN button. Wait until a quick flashing of the red light of the sensor eye is perceived. Then, press + to increase the delay in time and – to reduce it. DELAY OUT TIME: This button allows modifying the water flow time after the user removes his hands from the tap. A delay out time close to 0 will save more water. An increased delay out time will make the user experience more comfortable. If required, the delay out time can be modified as follows: Press the OUT button. Wait until a quick flashing of the red light of the sensor eye is perceived. Then, press + to increase the delay out time and – to reduce it. 24 HOUR HYGIENE FLUSH: If you have a compatible model with a 24 hours hygiene flush it is possible to enable and disable it . To activate the hygiene flush, press the clock button. Wait until a quick flashing of the red light of the sensor eye is perceived. Then press + to activate the hygiene flush or – to deactivate it. TEMPORARY OFF FUNCTION: This function is ideal to perform any kind of activity in front of the sensor without operating the system (for example, cleaning). The tap will remain shut for 1 minute when this button is pressed once. To cancel this function and to return to normal operation press the On/Off button again or wait 1 minute. RESET BUTTON: This function restores all the factory settings except for the sensor range. If required, press the Reset button and without releasing it, press the + button once. Note: To enter the self adjusting mode, use the ADJ button. To change the sensor range, use the RANGE button.
16 | Dolphin Blue | 400 Series
BATTERY REPLACEMENT
Battery models only When the battery weakens, the red indicator light will blink at a constant rate when the user’s hands are within the sensor range. The battery must be replaced within two weeks. To replace the battery (battery models only): 1. For DB/L/XL 400: Open carefully the batteries’ box and remove the old batteries. Replace the used batteries with six new 1.5V AA batteries. Close the box. 2. For DB 450: Release the screws at the panel and remove it. The battery box is located behind the panel. Open carefully the battery’s box and replace the used battery with a new 9V battery (Lithium battery is recommended). Close the box and re-assemble the wall cover panel. Important: Tap was supplied with A Self Adjusting Sensor. The ideal sensor range for the specific location will be set automatically again after changing the battery.
After you have
Check that there are no objects in front of the sensor after the battery replacement was completed.
replaced the battery, move away from the sensor range. Wait 15 seconds in order to allow the system to set the ideal sensor range. Then after the self adjustment has taken place the solenoid valve will be opened and closed for 1 second as an indication that the ideal sensor range was set and the product is ready for use.
Important: Spent batteries should not be disposed of with normal household waste. Contact your local authority for information on waste disposal and recycling.
400 Series | Dolphin Blue | 17
MAINTENANCE
Filter Cleaning Instruction This tap is provided with a stainless steel filter preventing foreign particles to enter the lines. If the water flow has decreased, this may be because the filter is clogged. The filter can be cleaned as follows: 1. For DB/X/XL 400 + 425: a. Shut-off the water shut off valve. b. Disconnect the water supply pipe from the adaptor and disassemble the filter from it. c. Wash the filter under running water. d. Reassemble the parts. e. Restore the incoming water supply. f. Make sure that there is no water leakage. 2. For DB 450 + DB 475 a. Release the screws at the panel and remove it. Turn off the regulating valve. b. Disassemble the solenoid valve by opening the nuts. c. Remove the filter and wash it under running water. d. Reassemble the filter. e. Reassemble the solenoid valve. f. Turn on the regulating valve and adjust the flow capacity. g. Make sure that there is no water leakage. Re-assemble the wall cover panel. Care and cleaning of chrome and special finishes DO NOT use steel wool or cleansing agents containing alcohol, acid, abrasives, or the like. Use of any prohibited cleaning or maintenance products or substances could damage the surface of the tap. For surface cleaning of tap us ONLY soap and water, then wipe dry with clean cloth or towel. When cleaning bathroom tile, the taps should be protected from any splattering of harsh cleansers.
18 | Dolphin Blue | 400 Series
SPARE PARTS LIST Self adjusting sensor kit ............................................................................. Cat.No. DB 07220056 Solenoid valve kit ............................................................................................ Cat.No. DB 07230017 Solenoid housing kit for DB/L/XL 400 + 425 ............................... Cat.No. DB 07231008 Transformer ......................................................................................................... Cat.No. DB 06522042 IP67 Battery box .............................................................................................. Cat.No. DB 06522020 Diaphragm ........................................................................................................... Cat.No. DB 04500001 Optional accessories Remote control ................................................................................................. Cat.No. DB 07100005 Battery box for 1 x 9V battery ............................................................... Cat.No. DB 06530008 IP67 Transformer box with transformer .......................................... Cat.No. DB 06530021 Transformer junction box........................................................................... Cat.No. DB 06530013 Transformer junction box exit with 3 meter cable and male connector ..................................................... Cat.No. DB 06000084 Mixing valve ...................................................................................................... Cat.No. DB 200070
LIMITED WARRANTY This product is covered by a limited warranty for two years from the date of purchase. If a BCP product is determined by an authorised BCP technician to be defective either in materials or in workmanship, BCP will replace or cover costs for repair of the product at its own discretion. If replacement or repair is not feasible, BCP will refund the original purchase price of the product. This warranty does not cover products that have not been installed in accordance with BCP’s installation guide, or products that have been damaged through abuse, misuse, misapplication, wear and tear and battery or water compositions. This includes (but is not limited to) the following: • Incorrect installation, inversions of supply pipes. • Pressures or temperatures exceeding recommended limits. • Improper manipulations, tampering, bad or lapsed maintenance. • Foreign bodies, dirt or scale introduced by the water supply.
400 Series | Dolphin Blue | 19
TROUBLE SHOOTING PROBLEM No water coming out of the tap
INDICATOR 1. Sensor flashes continuously when user’s hands are within the sensor’s range 2. Red light in the sensor does not flash when user’s hands are within the sensor’s range
3 Red light in the sensor flashes when user’s hands are within the sensor’s range
Water flow from spout does not stop
1 Sensor flashes when user’s hands are within the sensor’s range 2 Red light in the sensor does not flash when user’s hands are within the sensor’s range
Water flow diminished
CAUSE Low battery
SOLUTION Replace battery
1 Range is too short 2 Range is too long 3 Battery is completely used up 4 Unit is in ‘security mode’* 5 Sensor is picking up reflections from the washbasin or other objects 1 Connectors between the electronic unit and solenoid are disconnected 2 Debris or scale in solenoid
Increase the range Decrease the range The battery must be replaced
3 The central orifice in the diaphragm is plugged or the diaphragm is torn 4 The water supply pressure is higher than 8 bar Debris or scale in diaphragm
1 Sensor is dirty or covered 2 Sensor is picking up reflections from the washbasin or another object Filter or aerator clogged
Eliminate cause of reflection
Connect the electronic unit connectors to the solenoid Unscrew solenoid, pull out the plunger and the spring from the solenoid and clean them. Use scale remover material if needed. When replacing the plunger, please make sure the spring is in the vertical position. Clean the orifice or replace diaphragm Reduce the supply water pressure Clean the orifice or replace diaphragm
Clean or eliminate cause of interference Decrease the range or eliminate cause of reflection Remove, clean or re-install
*‘Security mode’: If the sensor is covered for longer than the specified security time, the tap will automatically shut off water flow. To return to normal operation remove any blockage to re-establish operation
20 | Dolphin Blue | 400 Series
DOLPHIN Soap Dispensers
Page 5
Taps DOLPHIN
Hot Air Hand Combination Paper Towel Toilet Dryers Units Tissue Dispenser Dispenser
Counter Mounte d 105
100
142
135°
Ø45
Taps
Ø50
Grab Rails Baby Changing Hotel Range s
Consumable
Product Families Installation Guide
• Touch Free Tap – for ultimate hygiene – prevents cross contamination • Quality polished chrome plated brass or lacquered nickel plated brass finishes available • Water Supply: Single inlet cold or pre-mixed – a TMV2 TMV3 thermostatic or mixing valve is recommende premixed applications. d for For 2 inlet hot and cold feed see page 183 • Flow rate – 6 litres/minute (down to 1.89 litres/minute please specify at – time of ordering) • Neopearl Aerator • Tap settings can be adjusted manually or by using remote control (DB51 – see page 188) • Mandatory Hygiene Flush feature can be specified to combat Legionella – please specify at time of orering • WRAS Approved Product • 2 year manufacturer ’s warranty • Maximum water temperature 70ºC • Operating pressure 0.5–8.0 bar (7–116 PSI)
Related items
Washroom Accessories
Bins
Power source
DB 200 / DB 225 Dolphin Blue Infrared Tap
DB 200 page 178
178 Dolphin Dispensers
DBL 400 page 180
WP 106 page 11
Product Data • H 142 x Ø 45 mm • Projection 105mm • Power Connections: tap male, power source female • Counter hole Ø 28-34mm Min-max thickness 2-27mm • 3/8" BSP water supply connector • Power: Plug-in 9 volt transformers or 9 volt battery (with low battery warning) – for other power source options see page 190-191 Product Codes Polished chrome finish • Powered by 6 x AAA / 9v PP3 battery • Powered by 9v plug in transformer
Request your 320 page catalogue today on
0800 0723 404
DB 200C DB 225C
Brushed nickel finish (designed to match brushed stainless steel) • Powered by 6 x AAA / 9v PP3 battery DB 200S • Powered by 9v plug in transformer DB 225S
WP 208R page 12
WP 112R page 105
Technical helpline
BC 2006 page 159
01424 202224
Bell-Chem Products Company Haywood Way, Hastings TN35 4PL Tel: +44 (0)1424 202224 Fax: +44 (0)1424 205 200
[email protected] www.dolphindispensers.co.uk
DB400 - DB 1400 series Tap Solenoid Inspection Instructions
User Manual Please read carefully before use
DOLPHIN
Tap Solenoid Inspection Instructions for Panel Mounted Taps
Turn off water supply before removing the solenoid.
Unplug the solenoid connector (red arrow) Unscrew the solenoid (yellow arrow) Please ensure that the flow direction arrow (green circle) is pointing towards the tap. The solenoid WILL NOT WORK if the fitting is reverse plumbed! The tap will continuously flow at a reduced rate.
The diaphragm is then accessible.
It can be seen that leaking can be caused by very small particles. The larger the particle the faster the tap will be leaking.
Remove the diaphragm and inspect very closely for particles on the surface, and clean. Take care not to lose the piston in the centre of the solenoid housing. The solenoid seating in the tap body should also be checked for particle ingress.
The piston should click and hold down when pushed into the solenoid. If the tap has been leaking a steady stream of water it is very likely to be that the piston spring has become dislodged.
If the piston does not hold in the depressed position it should be carefully removed to reveal the small spring beneath it. If it is lying on its side across the base, rather than standing upright as shown, it should be removed with a small slotted screwdriver.
Do not deform the spring but allow the coils to grip the screwdriver blade.
Occasionally there is no debris causing the leak but the spring needs to be carefully stretched 1mm to give increased pressure on the diaphragm. Take great care not to deform the spring.
Replace the piston with the spring inserted into the piston base. Holding the solenoid housing upside down, and inserting the piston swiftly will assist this operation. The solenoid housing should then be reassembled and replaced in the tap body. If the tap is still leaking please recheck the diaphragm for particles as the smallest contamination will cause leaking. Also wipe the diaphragm to remove any greasy deposits that may be present. A new diaphragm should be fitted if the tap is still leaking after thorough inspection and cleaning.
Bell-Chem Products Company Southpoint, Compass Park, Bodiam Robertsbridge TN32 5BS Tel: 01424 202224 Fax: 01424 205200 www: dolphindispensers.co.uk
[email protected]
DOLPHIN
DB400C **
Data Sheet
Correct for DB400, DB425, DB450, DB475, DBL400, DBL425, DBL450, DBL475 DBXL400, DBXL425, DBXL450, DBXL475 taps Shop Order No.:
DB400C
"O"-Ring No.:
******
Bag No. Insert No.
******
Date:
******
[bar]
0.15
0.20
0.30
0.50
1.00
1.50
2.00
3.00
4.00
5.00
6.00
[l/min]
4.12
4.89
6.00
7.82
11.16
13.76
15.96
19.59
22.62
25.23
27.59
Description Neostrahl
No. 1
[l/min]
2.36
2.75
3.36
4.30
5.59
4.77
4.92
5.16
5.16
4.96
4.71
PL-HC-LP 5.0L
No. 2
[l/min]
2.81
3.57
4.28
5.55
7.65
8.77
8.48
8.52
8.58
8.23
7.68
PL-HC-LP 8.0L
No. 3
[l/min]
2.29
2.77
3.47
4.28
4.49
4.07
4.10
4.20
4.14
3.98
3.75
PL-HC-LP 1.0GPM
No. 4
[l/min]
0.73
0.83
1.01
1.23
1.41
1.42
1.46
1.61
1.71
1.78
1.83
2.0L Spray
No. 5
[l/min]
1.97
2.29
2.87
3.73
5.02
5.71
6.04
6.15
6.24
6.46
6.59
Supplied PL Cascade 6.0L
No. 6
Now supplied as standard with PL-HC 1.0GPM aerator/flow regulator - No. 4 above
28.00
24.00
20.00
16.00
12.00
8.00
4.00
0.00 0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
pressure [bar]
31.10.13
DB400C
UK-JB 31-07-2009
Dolphin Blue Infrared Systems Important Design Tips
DOLPHIN
Dolphin Blue Infrared Systems Designing a washroom including Dolphin Blue Infrared Systems Dolphin Blue Infrared Taps, Shower Controls and Urinal Flush Valves offer significant water and energy savings. However, there are some simple DO’s and DON’Ts and TIPs which will help avoid 99% of the situations often associated with infrared systems for washrooms. It should be noted that these details are not exhaustive but will help eliminate 99% of situations. It is recommended that for larger projects especially where design restraints will result in taps being set on minimum or maximum settings, we would advise a very simple mock-up be set with materials to be used to ensure infrared device operates as desired.
DO’s Battery Back up
Pressure
DO include a battery back-up device when installing a transformer powered infrared tap in an accessible washroom.
DO ensure the static and dynamic pressure at the Dolphin Blue device is within the tolerances stated on the product literature / data sheet (please ask if you cannot find it). Most devices are tested to operate between 0.5 and 8 bar. If pressures are outside the stated tolerances please contact the Technical Helpline on 01424 20 22 24.
Security Time DO ensure security time is set at approximately 20 seconds on infrared taps especially in locations susceptible to vandalism. Also important: to be set at 20 seconds to comply with ECA/WTL scheme.
Flow Rate DO specify what flow rate is required when placing your order. Taps - 6 litre / minute is standard. 4 litre / minute is readily available.
Filters Do ensure filters supplied with the Dolphin Blue device are installed. It may not be sufficient to rely on the filters often included with thermostatic mixing valves as the gauge of the filter mesh may not be fine enough. It is also important to ensure pipes are flushed prior to connection and filters are inspected on a regular basis. Time between inspections will depend on hardness and quality of water.
Shower head - 9 litres/ minute is standard, 8 litres / minute is available. Distance from Transformer Please speak to the Dolphin Technical Helpline for other flow rates if required.
It is recommended you ensure the maximum distance between a Dolphin Blue Infrared Tap and its power source is 5 metres.
DON’Ts Mirrors
Panel Mounted Infrared Taps
It is not advisable to locate a Dolphin Blue Infrared device directly opposite a mirror where the infrared eye faces the mirror in such a way that it could reflect itself as this can cause false activations even if the mirror is 2-4 metres away from the infrared eye.
It is very important to ensure the distance between the sensor and the bottom of basin when installing a panel mounted Dolphin Blue Tap with an integral sensor is a minimum of 300mm above the bottom of the basin.
Two Infrared Taps It is not advisable to locate infrared taps directly opposite each other where the infrared eyes face each other as this can also cause false activations even when there is a fair distance between them.
TIPs
Minimum 300mm distance critical
Polished Traps and Sink Surfaces When installing a Dolphin Blue Panel Mounted Tap with an integral sensor it is recommended that you avoid a highly polished chrome trap or sink surface – it will act like a mirror to the tap sensor, potentially causing false activations and wasted water
Avoid polished/ chrome strainers
High Visibility Clothing
‘Tall’ Version Taps and Spout Lengths
It is a feature of most infrared devices in the washroom market that the reflective strips on high visibility clothing may cause the device to operate, even if someone just walks past, with no intention of using it.
Consider the position of the water outlet / aerator in relation to the basin.
The DB51 Dolphin Blue Remote Control can be used to reduce the range of a device to reduce these false activations but may not eliminate the phenomena completely.
Please feel free to discuss spout lengths with the Dolphin Technical Helpline on 01424 2022 24.
washrooms worth experiencing
0800 0723 404 Bell-Chem Products Company Haywood Way, Hastings, TN35 4PL
[email protected] www.dolphindispensers.co.uk
DOLPHIN
S O U T H PO I N T, CO M PA S S PARK, B O DI A M , RO B E RTS B R I DG E , T N 3 2 5 B ST, U N I T E D K I N G D OM + 44 (0)1424 202 224
TEL
+ 44 (0)1424 205 200
FA X
h e l l o @ d o l p i n so l u t i o n s.c o .u k d o l p h i n so l u t i o n s.c o .u k