DOUBLE-BALANCED MIXERS
M4-0220
Features
LO/RF 2 to 20 GHz IF DC to 700 MHz 7 dB Typical Conversion Loss 25 dB Typical LO to RF Isolation Ultra-Broadband RF and LO
Electrical Specifications - Specifications guaranteed from -55 to +100C, measured in a 50-Ohm system. Parameter Conversion Loss (dB) Isolation (dB) LO-RF LO-IF RF-IF
LO
RF
IF
(GHz)
(GHz)
(MHz)
Min
2-20
2-20
DC-500 500-700
2-20
2-20
7.0 7.5
20
2-20
Input Two-Tone Third Order Intercept Point (dBm) 2-20
Max
Diode Option LO drive level (dBm)
Input 1 dB Compression (dBm) 2-20
Typ
2-20
8.5 9.0
See Plots +2 +5
L (+7 to +10) M (+10 to +13)
+8
N (+13 to +16)
+11
H (+16 to +19)
+12 +15 +18
L (+7 to +10) M (+10 to +13) N (+13 to +16)
+21
H (+16 to +19)
Part Number Options Please specify diode level and package style by adding to model number.
Package Styles Connectorized Microstrip
A
1,2
Surface Mount
Examples
1,2
M4-0220LA, M4-0220LEZ-2
E
M4-0220
L
EZ
-2
EZ
(Model)
(Diode Option)
(Package)
(I-Port Configuration)
1
Connectorized test fixtures available for most carrier and surface mount packages. Consult factory. For non-connectorized packages, specify I-port configuration by adding –1 or –2 suffix to model number. Default is –2 configuration when not specified. 2
Marki Microwave reserves the right to make changes to the product(s) or information contained herein without notice. Marki Microwave makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does Marki Microwave assume any liability whatsoever arising out of the use of or application of any product.
215 Vineyard Court, Morgan Hill, CA 95037 | Ph: 408.778.4200 | Fax 408.778.4300 |
[email protected]
10/30/14
DOUBLE-BALANCED MIXERS
M4-0220
Page 2 LO/RF 2 to 20 GHz IF DC to 700 MHz Typical Performance Low-End Conversion Loss
-5
(dB)1-4
Conversion Loss (dB)1-4
-5
-7
-7
-9
-9
-11
-11
-13
-13
-15
-15
500
750
1000
1250
1500
1750
2000
2
4
6
8
RF Frequency (MHz)
Relative IF Response (dB)
0
10
12
14
16
18
20
RF Frequency (GHz) 3rd Harmonic LO Conversion Loss (dB) 1-4
-10
-1
-15
-2
-20
-3
-25
-4
-30
-5
-35
-6
-40
0
200
400
600
800
1000
1200
1400
6
8
10
12
IF Frequency (MHz) LO to RF Isolation (dB)
0
14
16
18
20
RF Frequency (GHz)
LO to IF Isolation (dB)
0
-10
-10
-20
-20
-30
-30
-40
-40 -50
-50 2
4
6
8
10
12
LO Frequency (GHz)
14
16
18
20
2
4
6
8
10
12
14
16
18
20
LO Frequency (GHz)
Marki Microwave reserves the right to make changes to the product(s) or information contained herein without notice. Marki Microwave makes no warranty, representation, or guarantee regarding the suitability of its products for any particular purpose, nor does Marki Microwave assume any liability whatsoever arising out of the use or application of any product.
215 Vineyard Court, Morgan Hill, CA 95037 | Ph: 408.778.4200 | Fax 408.778.4300 |
[email protected]
10/30/14
DOUBLE-BALANCED MIXERS
M4-0220
Page 3 LO/RF 2 to 20 GHz IF DC to 700 MHz Typical Performance
RF to IF Isolation (dB)
0
IF VSWR
6
-10
5
-20
4 -30 3 -40 2
-50 -60
1 2
4
6
8
10
12
14
16
18
20
0
200
400
600
RF VSWR
6
800
1000
1200
1400
IF Frequency (MHz)
RF Frequency (GHz)
LO VSWR
6
5
5
4
4
3
3
2
2 1
1 2
4
6
8
10
12
14
16
18
20
2
4
6
8
10
12
14
16
18
20
LO Frequency (GHz)
RF Frequency (GHz)
DATA SHEET NOTES: 1. Mixer Conversion Loss Plot is done with an IF frequency of 100 MHz. 2. Mixer Noise Figure typically measures within +0.5 dB of conversion loss for IF frequencies greater than 5 MHz. 3. Conversion Loss typically degrades less than 0.5 dB for LO drives 2 dB below the lowest and 3 dB above highest nominal LO drive levels. 4. Conversion Loss typically degrades less than 0.5 dB at +100°C and improves less than 0.5 dB at -55°C. 5. Maximum input power is +23 dBm at +25°C, derated linearly to +20 dBm at +100°C. 6. Specifications are subject to change without notice. Contact Marki Microwave for the most recent specifications and data sheets. 7. Catalog mixer circuits are continually improved. Configuration control requires custom mixer model numbers and specifications.
Marki Microwave reserves the right to make changes to the product(s) or information contained herein without notice. Marki Microwave makes no warranty, representation, or guarantee regarding the suitability of its products for any particular purpose, nor does Marki Microwave assume any liability whatsoever arising out of the use or application of any product.
© Marki Microwave, Inc. 215 Vineyard Court, Morgan Hill, CA 95037 | Ph: 408.778.4200 | Fax 408.778.4300 |
[email protected]
www.markimicrowave.com
10/30/14