8400100.qxp 3/20/2006 3:17 PM Page 60 900MB Modbus/RS-485 Series Analog Output Module Four Analog Outputs Outputs (2) DC Current or DC Voltage Four Discrete Outputs Outputs (4) Isolation RS-485 Modbus Outputs (2) BusWorks® Modbus I/O 10-36V DC or 24V AC 917/918MB Multi-Channel Analog Output Modules DC Current or DC Voltage Outputs Discrete Outputs Models 917MB: 4 current output channels 918MB: 4 voltage output channels Analog Output 917MB: 0 to 20mA, 4 to 20mA, 0 to 1mA DC 918MB: 0 to 10V, 0 to 5V, 0 to 1V DC Discrete Output Four output channels: Open-drain MOSFETs (1A DC loads) 0 to 35V DC Network Communication Modbus-RTU high-speed RS-485 Power Requirement 12 to 36V DC (917MB), 10 to 36V DC (918MB), 24V AC Power ■ Description ■ Special Features These modules drive four analog output channels and also feature four discrete outputs for on/off control. Isolation separates the output, power, and network circuits. Network communication adheres to the industry-standard RS-485 Modbus RTU protocol. AC and DC power sources are supported with nonpolarized, diode-coupled terminals. ■ Standard Modbus RTU protocol with high-speed RS-485 communication (up to 115K bps) ■ 12-bit D/A yields 0.1% of span resolution and accuracy ■ Four analog outputs in an inch-wide module reduces system costs and saves panel space ■ Four discrete outputs enable host-controlled on/off switching ■ Heavy-duty 1A solid-state relays provide dependable on/off control of industrial devices ■ Self-calibration lowers maintenance costs by reducing periodic manual calibration checks ■ Watchdog timers provide a configurable failsafe output state for use when host I/O communication is lost ■ Three-way isolation eliminates potential ground loops between power, output, and network circuitry ■ Self-diagnostics monitor microcontroller activity to detect operational failures (lock-up) and execute a reset to restore communication The analog outputs generate a signal based on communication from the host. They accommodate wide DC voltage or current ranges. Discrete outputs provide simple on/off switching capability (open-drain) for external devices. Combining analog outputs, on/off controllers, and a network interface in a single package, makes this instrument extremely powerful. Multi-channel design adds cost-efficiency and allows high-density mounting. Plus, safe, rugged construction make it reliable for both control room and distributed field I/O use in a broad range of temperature control applications. Custom module configurations are also possible (consult factory for details). Approvals CE marked. UL, cUL listed Class I; Division 2; Groups A, B, C, D. Tel: 248-295-0880 Fax: 248-624-9234 e-mail: [email protected] www.acromag.com 60 8400100.qxp 3/20/2006 3:18 PM Page 61 Modbus I/O ■ Performance ■ ■ Range user-configured. Selection applies to all channels. Output Range Resolution Accuracy (% span) 0 to 1V 0.274% ±0.6% (±6mV) 0 to 5V 0.055% ±0.1% (±5mV) 0 to 10V 0.027% ±0.1% (±10mV) Voltage Output (918MB) DC Voltage Output Ranges General Analog Output Resolution See current/voltage output specifications for more information. Ambient Temperature Effect LEDs indicate power, status, and discrete level/alarm. Output Short Circuit Protection ■ ±0.1% of span or ±2 LSB typical, whichever is larger, for spans equal to or greater than 5V. Output Current Power and Isolation Power Requirements Included. Response Time 110µs rise time typical, 150µs fall time typical, unloaded, for output to reach 98% of the final value in response to a step command. Time varies with load. Maximum Output Current Four independent open drain MOSFET switches with a common return that operate as low-side switches. Output Voltage Range Isolation Discrete Output Output Type Integral Non-Linearity ±0.1% of span or ±2 LSB typical, whichever is larger, for spans equal to or greater than 16mA. 12V minimum, 12.7V typical. 0 to 35V DC (up to 1A/channel continuous). External voltage source required. Output Load Resistance Range Output ON Resistance Output Compliance 0 to 630 ohms typical. 0.15 ohms maximum. Response Time Operation Digital outputs are set to their OFF state following a software or power-on reset. Outputs may be set to user-defined states following a watchdog timeout. Watchdog timeout output control takes precedence over limit alarm control. Alarm control takes precedence over host control. 11ms typical into 500 ohms, for measurement to reach 98% of the final value in response to a step command. Actual response time will vary with load. Supply Current Supply 10V DC 12V DC 24V DC 24V AC ■ 22.5mA DC typical. 10 to 36V DC (918MB), 12 to 36V DC (917MB) 22 to 26V AC. Current Draw (917) Not Recommended 275mA maximum 120mA maximum 210mA rms max. Current Draw (918) 100mA maximum 85mA maximum 45mA maximum 85mA rms max. 1500V AC for 60 seconds or 250V AC continuous. 3-way isolation between outputs, network, and power circuits. ■ Ordering Information Models 917MB-0900 918MB-0900 DC current (917MB) or voltage (918MB) output module Accessories TB1 + RTN TB2 RTN V2+ RTN RTN V3+ RTN RTN RTN OUT1 OUT0 DIGITAL OUTPUT WIRING CONNECTIONS SAME AS 913/914MB TB3 TB2 COM COM D D PWR RTN RTN OUT2 B A 36 35 34 33 32 31 I3+ RTN RS485 RTN V1+ ANALOG OUTPUTS RTN 21 22 23 24 25 26 I2+ ANALOG OUTPUTS 21 22 23 24 25 26 NETWORK COMMUNICATION TB3 + RTN RTN TB2 TB1/TB2 V+ ANALOG OUTPUT I1+ RTN OUT3 TB4 RTN DC VOLTAGE OUTPUT RL TB1 RL RTN RTN 46 45 44 43 42 41 ANALOG OUTPUT V0+ DIGITAL OUTPUTS TB1/TB2 I+ TB4 TB1 11 12 13 14 15 16 I RTN ANALOG OUTPUTS 11 12 13 14 15 16 DC CURRENT OUTPUT I0+ ANALOG OUTPUTS ANALOG OUTPUT CONNECTIONS RTN AC/DC POWER 10 TO 36V DC OR 24V AC NON-POLARIZED 900C-SIP Configuration Software Interface Package (includes software CD-ROM for Windows, RS-232/485 converter, and RS-485/three-wire cable) 4001-095 USB-to-RS232 adapter. See page 70 for more info. TBK-B02 Optional terminal block kit, barrier strip style, 4 pcs. TBK-S02 Optional terminal block kit, spring clamp style, 4 pcs. PS5R-D24 Power supply (24V DC, 2.1A). See Power Supplies on Page 199. For more information on software, network hardware, and mounting accessories, please see Pages 69-71. Tel: 248-295-0880 Fax: 248-624-9234 e-mail: [email protected] www.acromag.com 61 BusWorks® Modbus I/O LED Indicators 1 ohm. Integral Non-Linearity Range user-configured. Range selected applies to all channels. Output Range Resolution Accuracy (% span) 0 to 1mA 0.554% ±2.0% (±0.002mA) 0 to 20mA 0.028% ±0.1% (±0.02mA) 4 to 20mA 0.035% ±0.1% (±0.02mA) Communication Supported Modbus Commands Output Impedance Ambient Temperature 11.255V DC typical. Current Output (917MB) DC Current Output Ranges ■ 0 to 10mA DC maximum. Maximum Output Voltage ■ 4.1ms typical, from receipt of command to gate transition of the output MOSFET. The command/response protocol for communicating with this module adheres to the Modbus/RTU standard for the following Modbus Functions. Read Coil (Output) Status Report Slave ID Read Holding Registers Reset Slave Read Input Registers Force Single Coil (Output) Preset Single Register Force Multiple Coils (Output) Preset Multiple Registers Better than ±0.001% of output span per °C, or ±1.0uV/°C, whichever is greater. Operation (917MB): -25°C to 60°C* (-13°F to 140°F*). Operation (918MB): -25°C to 70°C (-13°F to 158°F). Storage: -40°C to +85°C (-40°F to +185°F). * Limit 917MB maximum ambient to 50°C (122°F) when using supply voltages less than 15V DC. Output Response Time 8400100.qxp 3/20/2006 3:18 PM Page 68 900MB Series 900MB Series Technical Diagrams TB4 TB3 Acromag DFT B A D D TB3 TB1 2.34 (59.4) BusWorks® Modbus I/O PWR TB2 2 3 CL RS485 3.75 (95.3) 0 1 36 35 34 33 32 31 TB4 ST COM COM 46 45 44 43 42 41 RUN 4.68 (118.9) "T" Rail Din Mounting Din EN 50022, 35mm 11 12 13 14 15 16 21 22 23 24 25 26 TB2 TB1 3.90 (99.1) 1.05 (26.7) NOTE: ALL DIMENSION ARE IN INCHES (MILLIMETERS) 4.35 (110.5) PERSONAL COMPUTER W/ WINDOWS 95/98 OR NT RS-232 SERIAL PORT CONNECTOR AT BACK OF PC PC RUNNING ACROMAG MODBUS CONFIG SOFTWARE INSTALL MODBUS CONFIGURATION SOFTWARE RS-232 TO RS-485 CONVERTER MODEL 5034-214 CONNECT THE RS-232 SIDE OF CONVERTER TO THE PC CAUTION: DO NOT CONNECT THE CABLE DIRECTLY TO THE PC WITHOUT THE CONVERTER, OR DAMAGE TO THE MODULE MAY RESULT. CABLE 5034-202 CONNECT THE RS-485 SIDE OF CONVERTER TO THE CABLE 900C-SIP COMMUNICATION CONNECTIONS CB A CONNECT WIRES AS SHOWN COM D TB4 TB4 Acromag RUN RED RS-485 D B BLACK D C GREEN COM REFER TO THE USER'S MANUAL THAT CAME WITH YOUR MODULE TO COMPLETE THE MODULE'S POWER AND I/O CONNECTIONS TB2 TB1 COLOR A PWR ANY 900MB MODULE TB1 R A STATUS LED FLASHES IN DEFAULT MODE. B RS485 D DEFAULT MODE SWITCH PUSH FOR DEFAULT MODE. D TB3 3 WIRE 36 35 34 33 32 31 COM 2 46 45 44 43 42 41 TB3 COM 1 RUN/PWR LED (GREEN) STATUS LED (YELLOW) TB4 ST DFT 0 D 11 12 13 14 15 16 21 22 23 24 25 26 TB1 TB2 Tel: 248-295-0880 Fax: 248-624-9234 e-mail: [email protected] www.acromag.com 68 3/20/2006 3:18 PM Page 69 Modbus Configuration Kit Software Interface Package Model No. 900C-SIP RS-485 Cable (DB-9) RS-232 to RS-485 Converter (non-isolated) Configuration Software for Windows ■ Ordering Information Software Interface Package 900C-SIP Software Interface Package. Includes Configuration Software (5034-186), Non-isolated RS-232 to RS-485 Serial Port Converter (5034-214), and RS-485 Cable (5034-202). Items can also be ordered separately below. 5034-186 Configuration Software for Windows (95/98/2000/ME/ NT4/XP) on CD-ROM. 5034-214 Non-isolated RS-232 to RS-485 Serial Port Converter, DB-9F to DB-9F. 5034-202 RS-485 to 3-wire Cable Converter, DB-9M to 3 x 12AWG RS-485 Cable, 8 ft. This package includes Windows® Configuration Software, an RS-232-to-485 Serial Port Converter, and an RS-485 Signal Cable. These components provide everything you need to set up a Series 900 I/O module from your desktop PC before installing it on the network. RS-232/485 Converter (non-isolated) RS-485 to 3-wire 5034-214 5034-202 ■ Ordering Information Universal 50W Power Supply Top View (dimensions in mm) Side View (dimensions in mm) 5 6. -ø 10 3.8 90 80 ø4 4- 13 .5 The PS5R-D24 is the ideal power source to drive your network. PS5R-D24 Universal Power Supply 13 13 13 DC ON 35.3 Universal power 85 to 264V AC, 105 to 370V DC 60 75 Input Power Requirement V.ADJ Output 5 24V DC, 2.1A (50W) M3.5 Terminal Screws 6 95 12 Mounting Hardware DIN-Rail Mounting For your convenience, Acromag offers several mounting accessories to simplify your system installation. Our 19” rack-mount kit provides a clean solution for mounting your I/O modules and a power supply. Or you can buy precut DIN rail strips for mounting on any flat surface. ■ Ordering Information 20RM-16-DIN 19" rack-mount kit with DIN rail. DIN RAIL 3.0 DIN RAIL 16.7 DIN rail strip, Type T, 3 inches (75mm) or 16.7 inches (425mm) Dimensions in inches (mm). Tel: 248-295-0880 Fax: 248-624-9234 e-mail: [email protected] www.acromag.com 69 BusWorks® Modbus I/O Network Power I/O 7.35 8400100.qxp Accessories Model 4001-095 USB-to-Serial Adapter HOST USB PERSONAL COMPUTER RUNNING WINDOWS 98/ME/2000/XP TO HOST USB PORT 4001095 USB SERIAL CONVERTER USB MALE HOST PC RUNNING ACROMAG CONFIGURATION SOFTWARE LED RS232 DB9P 6 FEET OF CABLE Simplifies configuration of Acromag I/O Modules ◆ Enables configuration via USB port Description Performance Specifications Ordering Information This device is a USB-to-serial adapter that you can use to communicate with many Acromag I/O products for setup and re-configuration for your application. USB Specification Version 1.1 Data rate Up to 115.2Kbps Environmental Standards RoHS-compliant Basic Power Consumption 150mA PC Requirements Windows® 7 (32-/64-bit) / Vista (32-/64-bit) / XP (32-/64-bit) / Server 2003 & 2008 (32-/64-bit) / 2000 / ME / 98SE / 98 NOTE: For more information visit www.acromag.com. Key Features & Benefits ■ Connects to I/O modules via USB (other adapters may be necessary) ■ Complete RS232 control signals ■ Conforms to USB Specification, Version 1.1 ■ USB-powered ■ Cable length, 6 ft., UL approved IntelliPack 800x Series Adapter and Cable INTELLIPACK SERIAL ADAPTER Adapters 4001-095 USB to serial adapter. Includes driver CD and manual. 5030-913 Serial port adapter. DB9S connector to RJ11 jack. 5034-202 RS-485 to 3-wire cable converter and cable, DB-9M to 3 x 12AWG RS-485 cable, 8 ft. 5032-287 RS-232 to 151T transmitter configuration device converter and cable, 6 ft. 5034-214 Non-isolated RS-232 to RS-485 Serial Port Converter, DB-9F to DB-9F. Cables RJ11 JACK (6 CONDUCTOR) 5030-902 Cable. 6 feet long with RJ11 plug at each end. RJ11 PLUG (6 CONDUCTOR) MODEL 5030-902 (6 feet long) 9-PIN CONNECTOR (DB9S) MODEL 5030-913 4 4 3 mV+ 3 & 4 Wire RTD 2 1 -T/C, 2 3 1 – MODEL 5032-787 CABLE 5034-202 TOP VIEW RS-485 RS-232 5034-202 C DB9 FEMALE 6 FEET OF CABLE 151T TRANSMITTER + 1046-016 Acromag 1046-016 Acromag RS232 TO RS485 SERIAL CONVERTER (MODEL 5034-214) TO RS232 TOP VIEW 900MB Modbus Series Adapter and Cable PLUG INTO TOP OF TRANSMITTER 151C-SIP INTERFACE ADAPTER Transmitter temperature of 151T plug into top 151T Transmitter Series Adapter and Cable DB9 FEMALE B A DB9 MALE COM D D Tel: 248-295-0880 Bulletin #8400-572 ■ Fax: 248-624-9234 ■ [email protected] ■ www.acromag.com ■ 30765 S Wixom Rd, Wixom, MI 48393 USA All trademarks are property of their respective owners. Copyright © Acromag, Inc. 2009. Data subject to change without notice. Printed in USA 10/2009.