Preview only show first 10 pages with watermark. For full document please download

Download Datasheet For Fas-425c By Skynet Electronic

   EMBED


Share

Transcript

Industrial PC Rated 150W~250W DC to DC Series Features: Eficiency between 65% to 70% PS2 size mounting Meet UL, CSA, and TUV safety Applications: For industrial PC, telecommunication application and motorcar purpose General Speciications: Input voltage ..................................................... see output table Cooling ...................................................... forced air convection Eficiency ................................................... > 65% at rated load Storage temperature ........................................... -40oC to +75oC Short circuit protection ........................................ auto recovery Humidity ........................................... up to 95% non condensing for D12-AX25, SNP-425C, SNP-425D EMI radiation ....................................................... FCC class "B" hiccup for D48-815A, FAS-425C Over voltage protection ................................................ crowbar Operating temperature ..................... 0oC to 45oC for FAS-425C 0 C to 50 C for D48-815A, SNP-425C, SNP-425D o EN55022 class "B" EMS ......................................................... EN61000-4-2,-3,-4,-5 Safety ................................................................. meet UL 60950 o CSA C22.2 No. 950 0 C to 70 C for D12-AX25, derating: 2% / C > 40 C o o o Mechanical Speciications: Notes: D12-AX25 1. 2. 3. DC WIRE HARNESS 3.5 4.25 4.0 20.0 EN60950-1 o 110.0 350.0±20 144.0 140.0 250.0±20 150.0±20 150.0±20 400.0±20 DRAWING NO. :D12-AX25 150.0 300.0±20 64.0 52.0 86.2 27.0 20.0 6.0 16.0 5.0 48.0 -Clark- MAY 2013 115.0 150.0±20 Wire Color Voltage ORANGE RED YELLOW BLUE GREY WHITE BLACK PURPLE GREEN 3.3V 5V 12V -12V P.G. -5V GND +5Vsb POWER ON 150.0±20 4. 5. Dimensions shown in mm as left. Tolerance speciied is ±0.8mm. Size: 150 x 140 x 86.2 (mm) Packing: For D12-AX25 Net weight: 1750 g approx. / unit Gross weight: 16 kg approx. / carton, 8 units / carton Carton size (mm): 530 (L) x 530 (W) x 270 (H) For FAS-425C Net weight: 1593 g approx. / unit Gross weight: 15 kg approx. / carton, 8 units / carton Carton size (mm): 470 (L) x 460 (W) x 220 (H) For D48-815A, SNP-425C, SNP-425D Net weight: 1330 g approx. / unit Gross weight: 13 kg approx. / carton, 8 units / carton Carton size (mm): 470 (L) x 460 (W) x 200 (H) DC Input : using terminal blocks DC Output : ATX : Molex 39-01-2200 or equivalent AT : Burndy GTC6P-1 or equivalent Disk driver : AMP 1-486424-0 or equivalent 3 1/2 loppy driver : AMP 171822-4 or equivalent 10 years Warranty (contact Skynet's Distributors for details) ** This data sheet is only for models selection. For business, engineering speciication by model must be used. 4-1 Industrial PC Rated 150W~250W DC to DC Series Output Speciications: MODEL NO. D48-815A D12-AX25 FAS-425C SNP-425C SNP-425D INPUT VOLTAGE OUTPUT LOAD VOLTAGE NOISE REG. REG. TYPICAL +4.90V~+5.10V +11.28V~+12.72V -11.40V~-12.60V -4.75V~-5.25V +3.13V~+3.46V +4.90V~+5.10V 50mV 120mV 120mV 50mV 50mV 50mV ±1% ±1% ±1% ±1% ±1% ±1% ±5% ±5% ±5% ±5% ±4% ±5% 70% +4.80V~+5.20V +11.40V~+12.60V -11.40V~-12.60V -4.75V~-5.25V +3.13V~+3.47V +4.75V~+5.25V 50mV 100mV 100mV 100mV 50mV 50mV ±1% ±1% ±1% ±1% ±1% ±1% ±5% ±5% ±2% ±3% ±3% ±1% 65% 30A 12A 2A 2A +4.90V~+5.10V +11.28V~+12.72V -11.40V~-12.60V -4.75V~-5.25V 50mV 120mV 120mV 50mV ±1% ±1% ±1% ±1% ±4% ±5% ±3% ±3% 65% 25A 10A 1A 1A 30A 12A 2A 2A +4.90V~+5.10V +11.28V~+12.72V -11.40V~-12.60V -4.75V~-5.25V 50mV 120mV 120mV 50mV ±1% ±1% ±1% ±1% ±4% ±5% ±3% ±3% 70% 25A 10A 1A 1A 30A 12A 2A 2A +4.95V~+5.10V +11.28V~+12.72V -11.40V~-12.60V -4.75V~-5.25V 50mV 120mV 120mV 50mV ±1% ±1% ±1% ±1% ±4% ±5% ±3% ±3% 70% RAIL MIN. RATED MAX. +48VDC +5V +12V -12V -5V +3.3V +5Vsb 1A 0A 0A 0A 1A 0A 16A 1.4A 0.5A 0.5A 9A 0.72A 20A 4A 1A 1A 16A 1.2A 2A 0.1A 0A 0A 0A 0A 25A 8A 1A 0.5A 8A 0.72A 30A +12VDC +5V +12V -12V -5V +3.3V +5Vsb +24VDC +5V +12V -12V -5V 1A 0A 0A 0A 25A 10A 1A 1A -48VDC +5V +12V -12V -5V 1A 0A 0A 0A +110VDC +5V +12V -12V -5V 1A 0A 0A 0A 22A PEAK ACCURACY RIPPLE LINE LOAD EFFICIENCY Notes: 1. 2. 3. 4. 5. Each output can provide up to max. load temporarily. Continuous staying in more than rated load is not allowed. At factory, all outputs in 60% rated load condition, each output is checked to be within the accuracy range. Line regulation is deined by changing ±10% of input voltage from nominal line at rated load. Load regulation is deined by changing ±40% of measured output load from 60% rated load at another output set to 60% rated load. Ripple & noise is measured by using 15MHz bandwidth limited oscilloscope and terminated each output with a 0.47µF capacitor at rated load and nominal line. 6. Eficiency is measured at rated load and nominal line. -Clark- 4-2 ** This data sheet is only for models selection. For business, engineering speciication by model must be used. MAY 2013 Industrial PC Rated 150W~250W DC to DC Series Performance for D12-AX25: 1. Switching frequency ripple 2. Switching frequency ripple +5V/25A +3.3V/8A +12V/8A -5V/0.5A +5Vsb/0.72A -12V/1A 50mV/div, 5us/div 50mV/div, 5us/div 3. Line frequency ripple 4. Line frequency ripple +5V/25A +3.3V/8A +12V/8A -5V/0.5A +5Vsb/0.72A -12V/1A 50mV/div, 5ms/div 50mV/div, 5ms/div 6. Output turn on wave form 5. Output turn on wave form +12V/8A +5V/25A +5Vsb/0.72A +3.3V/8A -5V/0.5A -12V/1A 5VDC/div, 10ms/div 5VDC/div, 0.2s/div -Clark- MAY 2013 ** This data sheet is only for models selection. For business, engineering speciication by model must be used. 4-3 Industrial PC Rated 150W~250W DC to DC Series 8. +5V Over voltage protection 7. Output turn off wave form Trip point around 6.24V +12V/8A +5V/25A -5V/0.5A -12V/1A 2V/div, 10ms/div 10ms/div, 5VDC/div 9. +5V step response 10. +12V step response +12V +5V 0.5V/div 0.2V/div +12V 0.5V/div 0.1V/div +5V 2ms/div +5V steps from 5A to 25A other output at 60% load 11. Power good signal 2ms/div +12V steps from 1.6A to 8A other output at 60% load 12. Power fail signal +5V P.G. 2V/div, 50ms/div +5V P.F. 2V/div, 1ms/div -Clark- 4-4 ** This data sheet is only for models selection. For business, engineering speciication by model must be used. MAY 2013