Transcript
2014-01-15
OSLON Black Flat Datasheet Version 1.4 LS H9PP
OSLON Black Flat is a new small size high-flux LED for slim designs. The black package stands for high stability.
OSLON Black Flat ist eine neue kompakte hoch effiziente Lichtquelle für platzsparende Designs. Das schwarze Gehäuse steht für eine hohe Stabilität.
Features:
Besondere Merkmale:
• • • • •
Package: SMD epoxy package Technology: InGaAlP Thinfilm Viewing angle at 50 % IV: 120° Color: super red (633 nm) ESD - withstand voltage: 8 kV acc. to ANSI/ESDA/JEDEC JS-001 (HBM, Class 3B) • Corrosion Robustness: Improved corrosion robustness • Qualifications: The product qualification test plan is based on the guidelines of AEC-Q101-REV-C, Stress Test Qualification for Automotive Grade Discrete Semiconductors.
• • • • •
Applications
Anwendungen
• • • • • •
Gehäusetyp: SMD Epoxid Gehäuse Technologie: InGaAlP Thinfilm Abstrahlwinkel bei 50 % IV: 120° Farbe: super rot (633 nm) ESD - Festigkeit: 8 kV nach ANSI/ESDA/JEDEC JS-001 (HBM, Klasse 3B) • Korrosionsstabilität: Verbesserte Korrosionsstabilität • Qualifikationen: Die Produktqualifikation wurde entsprechend der Richtlinie AEC-Q101-REV-C, „Stress Test Qualification for Automotive Grade Discrete Semiconductors“, getestet.
Architectural Lighting indoor and outdoor Automotive Lighting Interior and Exterior Coupling into Light Guides Decorative Lighting Signal and Symbol Luminary Signaling
2014-01-15
• • • • • •
1
Architekturbeleuchtung innen und außen Automobilbeleuchtung innen und außen Einkopplung in Lichtleiter Dekorative Beleuchtung Signal- und Symbolleuchten Signalanlagen
Version 1.4
LS H9PP
Ordering Information Bestellinformation Type:
Luminous Flux 1) page 21
Ordering Code
Typ:
Lichtstrom 1) Seite 21
Bestellnummer
IF = 350 mA ΦV [lm] LS H9PP-HYJY-1-1 Note:
33 ... 61
Q65111A4303
The above Type Numbers represent the order groups which include only a few brightness groups (see page 5). Only one group will be shipped on each packing unit (there will be no mixing of two groups on each packing unit). E. g. LS H9PP-HYJY-1-1 means that only one group HY, HZ, JX, JY will be shippable for any packing unit. In order to ensure availability, single brightness groups will not be orderable. In a similar manner for colors where wavelength groups are measured and binned, single wavelength groups will be shipped on any one packing unit. E. g. LS H9PP-HYJY-1-1 means that only one wavelength group 1 will be shippable. LS H9PP-HYJY-1-1 means that the device will be shipped within the specified limits as stated on page 5In order to ensure availability, single wavelength groups will not be orderable (see page 5). In a similar manner for colors where forward voltage groups are measured and binned, single forward voltage groups will be shipped on any packing unit. E. g. LS H9PP-HYJY-1-1 means that only one forward voltage group J3,M3,Q3,T3 will be shippable. In order to ensure availability, single forward voltage groups will not be orderable (see page 5).
Anm.:
Die oben genannten Typbezeichnungen umfassen die bestellbaren Selektionen. Diese bestehen aus wenigen Helligkeitsgruppen (siehe Seite 5). Es wird nur eine einzige Helligkeitsgruppe pro Verpackungseinheit geliefert. Z. B. LS H9PP-HYJY-1-1 bedeutet, dass in einer Verpackungseinheit nur eine der Helligkeitsgruppen HY, HZ, JX, JY enhalten ist. Um die Liefersicherheit zu gewährleisten, können einzelne Helligkeitsgruppen nicht bestellt werden. Gleiches gilt für die Farben, bei denen Wellenlängengruppen gemessen und gruppiert werden. Pro Verpackungseinheit wird nur eine Wellenlängengruppe geliefert. Z. B. LS H9PP-HYJY-1-1 bedeutet, dass in einer Verpackungseinheit nur eine der Wellenlängengruppen 1 enthalten ist (siehe Seite 5). LS H9PP-HYJY-1-1 bedeutet, dass das Bauteil innerhalb der spezifizierten Grenzen geliefert wird. Um die Liefersicherheit zu gewährleisten, können einzelne Wellenlängengruppen nicht bestellt werden. Gleiches gilt für die LEDs, bei denen die Durchlassspannungsgruppen gemessen und gruppiert werden. Pro Verpackungseinheit wird nur eine Durchlassspannungsgruppe geliefert. Z. B. LS H9PP-HYJY-1-1 bedeutet, dass nach Durchlassspannungsgruppen gruppiert wird. In einer Verpackungseinheit ist nur eine der Durchlassspannungsgruppen J3,M3,Q3,T3 enthalten (siehe Seite 5). Um die Liefersicherheit zu gewährleisten, können einzelne Durchlassspannungsgruppen nicht direkt bestellt werden.
2014-01-15
2
Version 1.4
LS H9PP
Maximum Ratings Grenzwerte Parameter
Symbol
Values
Unit
Bezeichnung
Symbol
Werte
Einheit
Operating temperature range Betriebstemperatur
Top
-40 ... 125
°C
Storage temperature range Lagertemperatur
Tstg
-40 ... 125
°C
Junction temperature for short time applications * Sperrschichttemperatur für Kurzzeitanwendung *
Tj
175
°C
Junction temperature Sperrschichttemperatur
Tj
150
°C
Forward current Durchlassstrom (TS = 25 °C)
IF
20 ... 1000
mA
Surge current Stoßstrom (t <= 10 μs; D = 0.005; T S = 25 °C)
IFM
2500
mA
Reverse voltage Sperrspannung (TS = 25 °C)
VR
not designed for reverse operation
V
8
kV
VESD ESD withstand voltage ESD Festigkeit (acc. to ANSI/ESDA/JEDEC JS-001 - HBM, Class 3B)
Note: *The LED chip exhibits excellent performance but slight package discoloration occurs at highest temperatures. Exemplary median lifetime for Tj = 175°C is 100h. Anm:
*Auch bei höchsten Temperaturen zeigt der LED Chip sehr gute Leistungsmerkmale, aber es kann eine leichte Verfärbung des Gehäuses auftreten. Die mittlere Lebensdauer bei Tj = 175°C beträgt 100h.
2014-01-15
3
Version 1.4
LS H9PP
Characteristics (TS = 25 °C; IF = 350 mA) Kennwerte Parameter
Symbol
Values
Unit
Bezeichnung
Symbol
Werte
Einheit
Wavelength at peak emission Wellenlänge d. emittierten Lichtes
(typ.)
λpeak
645
nm
Dominant Wavelength 2) page 21 Dominantwellenlänge 2) Seite 21
(min.) (typ.) (max.)
λdom λdom λdom
627 633 639
nm nm nm
Spectral bandwidth at 50% Irel max Spektrale Bandbreite b. 50% Irel max
(typ.)
Δλ
16
nm
Viewing angle at 50 % IV Abstrahlwinkel bei 50 % IV
(typ.)
2ϕ
120
°
Forward voltage 3) page 21 Durchlassspannung 3) Seite 21
(min.) (typ.) (max.)
VF VF VF
2.00 2.15 2.60
V V V
IR
not designed for reverse operation
Reverse current Sperrstrom Real thermal resistance junction / solder point
4) page 21
Realer Wärmewiderstand Sperrschicht / Lötpad
(typ.) (max.)
Rth JS real Rth JS real
6.5 11
K/W K/W
(typ.) (max.)
Rth JS el Rth JS el
3.8 6.4
K/W K/W
4) Seite 21
"Electrical" thermal resistance junction / solder point 4) page 21 "Elektrischer" Wärmewiderstand Sperrschicht / Lötpad 4) Seite 21 (with efficiency η e = 42 %) Note:
Individual forward voltage groups see next page
Anm.:
Durchlassspannungsgruppen siehe nächste Seite
2014-01-15
4
Version 1.4
LS H9PP
Brightness Groups Helligkeitsgruppen Group
Luminous Flux
Luminous Flux
1) page 21
Gruppe
Lichtstrom
1) page 21
1) Seite 21
Lichtstrom
1) Seite 21
Luminous Intensity 5) page 21
Lichtstärke 5) Seite 21
(min.) ΦV [lm]
(max.) Φ V [lm]
(typ.) IV [cd]
HY
33
39
11.9
HZ
39
45
13.9
JX
45
52
16
JY
52
61
18.6
Note:
The standard shipping format for serial types includes either a lower family group, an upper family group or a grouping of all individual brightness groups of only a few brightness groups. Individual brightness groups cannot be ordered.
Anm.:
Die Standardlieferform von Serientypen beinhaltet entweder eine untere Familiengruppe, eine obere Familiengruppe oder eine Sammelgruppe, die aus nur wenigen Helligkeitsgruppen besteht. Einzelne Helligkeitsgruppen sind nicht bestellbar.
Forward Voltage Groups 3) page 21 Durchlassspannungsgruppen 3) Seite 21 Group Gruppe
(min.) VF [V]
(max.) VF [V]
J3
2.00
2.15
M3
2.15
2.30
Q3
2.30
2.45
T3
2.45
2.60
Dominant Wavelength Groups 2) page 21 Dominant Wellenlängengruppen 2) Seite 21 Group
super red
Gruppe
(min.) λdom [nm]
(max.) λdom [nm]
1
627
639
Note:
No packing unit / tape ever contains more than one color group for each selection.
Anm.:
In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe für jede Farbe enthalten.
2014-01-15
5
Version 1.4
LS H9PP
Group Name on Label Gruppenbezeichnung auf Etikett Example: HY-1-J3 Beispiel: HY-1-J3 Brightness Helligkeit
Wavelength Wellenlänge
Forward Voltage Durchlassspannung
HY
1
J3
Note:
No packing unit / tape ever contains more than one group for each selection.
Anm.:
In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe für jede Selektion enthalten.
2014-01-15
6
Version 1.4
LS H9PP
Relative Spectral Emission - V(λ) = Standard eye response curve 5) page 21 Relative spektrale Emission - V(λ) = spektrale Augenempfindlichkeit 5) Seite 21 Φrel = f (λ); TS = 25 °C; IF = 350 mA Irel
LS H9PP
1,0
: super red : Vλ
0,8
0,6
0,4
0,2
0,0 350
400
450
500
550
600
650
700
750
800
λ [nm]
Radiation Characteristics 5) page 21 Abstrahlcharakteristik 5) Seite 21 Irel = f (ϕ); T S = 25 °C
LS H9PP
ϕ [°] -10°
0°
10°
-20°
20°
30°
40°
50°
60°
70°
80°
90° 1,0
-30° -40°
0,8
-50° 0,6 -60° 0,4
-70°
0,2
-80°
0,0
-90°
-100°
2014-01-15
7
Irel
Version 1.4
LS H9PP
Forward Current 5) page 21 Durchlassstrom 5) Seite 21
Relative Luminous Flux 5) page 21 , 6) page 21 Relativer Lichtstrom 5) Seite 21 , 6) Seite 21
IF = f (VF); TS = 25 °C IF [mA]
ΦV/ΦV(350 mA) = f(IF); TS = 25 °C ΦV
LS H9PP
1000
ΦV(350mA)
LS H9PP
2,5
800 2,0
600
1,5
1,0
400
0,5 200
0,0 20
1,8
2,0
2,2
2,4
2,6
0 40
0 60
0 80
00 10
IF [mA]
VF [V]
2014-01-15
0 20
8
Version 1.4
LS H9PP
Relative Forward Voltage 5) page 21 Relative Vorwärtsspannung 5) Seite 21
Relative Luminous Flux 5) page 21 Relative Lichtstrom 5) Seite 21
ΔVF = VF - VF(25 °C) = f(Tj); IF = 350 mA
ΦV/ΦV(25 °C) = f(Tj); I F = 350 mA
LS H9PP
Φv
ΔVF [V]
LS H9PP
1,6
Φv(25°C)
0,20
1,4 0,15 1,2 0,10 1,0 0,05 0,8 0,00 0,6 -0,05
0,4
-0,10
-0,15 -40 -20
0,2
0
20
40
60
0,0 -40 -20
80 100 120
Tj [°C]
λdom = f(Tj); IF = 350 mA
LS H9PP
λ dom [nm]
2
0
-2
-4
0
20
40
60
80 100 120
Tj [°C]
2014-01-15
20
40
60
80 100 120
Tj [°C]
Dominant Wavelength 5) page 21 Dominante Wellenlänge 5) Seite 21
-40 -20
0
9
Version 1.4
LS H9PP
Max. Permissible Forward Current Max. zulässiger Durchlassstrom IF = f (T)
IF [mA]
LS H9PP
1100 1000 900 800 700 600 : TS
500 400 300 200 100 0
Do not use below 20 mA 0
20
40
60
80
100
120
140
TS [°C]
Permissible Pulse Handling Capability Zulässige Impulsbelastbarkeit IF = f(tp)
Permissible Pulse Handling Capability Zulässige Impulsbelastbarkeit IF = f(tp)
D: Duty cycle, TS = 25 °C 2.6 A IF 2.4
D: Duty cycle, TS = 85 °C
OHL04374
t
D = TP
2.6 A IF 2.4
tP IF T
2.2 2.0 1.8 1.6 1.4 1.2
OHL04374
t
D = TP
tP IF T
2.2 2.0
D= 0.005 0.01 0.02 0.05 0.1 0.2 0.5 1
1.8 1.6 1.4 1.2
D= 0.005 0.01 0.02 0.05 0.1 0.2 0.5 1
1.0
1.0
0.8 -5 10 10-4 10-3 10-2 10-1 100 101 s 102
0.8 -5 10 10-4 10-3 10-2 10-1 100 101 s 102
tp
2014-01-15
tp
10
Version 1.4
LS H9PP
Package Outline 7) page 21 Maßzeichnung 7) Seite 21
Approximate Weight:
25 mg
Gewicht:
25 mg
Mark:
Cathode
Markierung:
Kathode
ESD information:
LED is protected by ESD device which is connected in parallel to LED-Chip.
ESD Information:
Die LED enthält ein ESD-Bauteil, das parallel zum Chip geschalten ist.
Corrosion robustness:
Test conditions: 40 °C / 90 % rh / 15 ppm H2S / 336 h = Stricter than IEC 60068-2-43 (H2S) [25°C / 75 % rh / 10 ppm H2S / 21 days] = Regarding relevant gas (H2S) stricter than EN 60068-2-60 (method 4) [25 °C / 75 % rh / 200 ppb SO2, 200 ppb NO2,10 ppb Cl2 / 21 days]
2014-01-15
11
Version 1.4
LS H9PP
Korrosionsfestigkeit:
Test Kondition: 40°C / 90 % rh / 15 ppm H2S / 336 h = Besser als IEC 60068-2-43 (H2S) [25°C / 75 % rh / 10 ppm H2S / 21 Tage] = Bezogen auf das Gas (H2S) besser als EN 60068-2-60 (method 4) [25°C / 75 % rh / 200ppb SO2, 200ppb NO2,10ppb Cl2 / 21 Tage]
Recommended Solder Pad 7) page 21 Empfohlenes Lötpaddesign 7) Seite 21
2014-01-15
Reflow soldering Reflow-Löten
12
Version 1.4
LS H9PP
Recommended Solder Pad 7) page 21 Empfohlenes Lötpaddesign 7) Seite 21
Reflow soldering Reflow-Löten
Note:
For superior solder joint connectivity results we recommend soldering under standard nitrogen atmosphere. Package not suitable for ultra sonic cleaning.
Anm.:
Um eine verbesserte Lötstellenkontaktierung zu erreichen, empfehlen wir, unter StandardStickstoffatmosphäre zu löten. Das Gehäuse ist für Ultraschallreinigung nicht geeignet.
2014-01-15
13
Version 1.4
LS H9PP
Reflow Soldering Profile Reflow-Lötprofil
Preconditioning: JEDEC Level 2 acc. to JEDEC J-STD-020D.01 OHA04525
300 ˚C
T 250
Tp 245 ˚C
240 ˚C
tP
217 ˚C 200
tL
150
tS
100
50 25 ˚C 0
0
50
100
150
200
s 300
250
t
OHA04612
Profile Feature Profil-Charakteristik
Symbol Symbol
Pb-Free (SnAgCu) Assembly Minimum
Ramp-up rate to preheat*) 25 °C to 150 °C Time tS TSmin to TSmax
tS
60
Ramp-up rate to peak*) TSmax to TP
Recommendation
Maximum
2
3
100
120
2
3
Unit Einheit K/s s K/s
Liquidus temperature
TL
217
Time above liquidus temperature
tL
80
100
s
Peak temperature
TP
245
260
°C
Time within 5 °C of the specified peak temperature TP - 5 K
tP
20
30
s
3
6
K/s
10
Ramp-down rate* TP to 100 °C
480
Time 25 °C to TP All temperatures refer to the center of the package, measured on the top of the component * slope calculation DT/Dt: Dt max. 5 s; fulfillment for the whole T-range
2014-01-15
°C
14
s
Version 1.4
LS H9PP
Method of Taping 7) page 21 Gurtung 7) Seite 21
2014-01-15
15
Version 1.4
LS H9PP
Tape and Reel Gurtverpackung 12 mm tape with 2000 pcs. on ∅ 180 mm reel W1 D0
P0
A N
F W
E
13.0 ±0.25
P2
Label
P1 Direction of unreeling
Direction of unreeling W2
Leader: min. 400 mm * Trailer: min. 160 mm * *) Dimensions acc. to IEC 60286-3; EIA 481-D OHAY0324
Tape dimensions in mm (inch) Tape dim ensions in m m ( inch)
W
P0
P1
P2
D0
E
F
12 +0.3/-0.1
4 ± 0.1 (0.157 ± 0.004)
4 ± 0.1 (0.157 ± 0.004) or 8 ± 0.1 (0.315 ± 0.004)
2 ± 0.05 (0.079 ± 0.002)
1.5 ± 0.1 (0.059 + 0.004)
1.75 ± 0.1 (0.069 ± 0.004)
5.5 ± 0.05 (0.217 ± 0.002)
Reel dimensions in mm (inch) Reel dim ensions in m m ( inch)
A
W
Nmin
W1
W2max
180 (7)
12 (0.472)
60 (2.362)
12.4 + 2 (0.488 + 0.079)
18.4 (0.724)
2014-01-15
16
Version 1.4
LS H9PP
Barcode-Product-Label (BPL) Barcode-Produkt-Etikett (BPL)
EX AM PL E
OSRAM Opto po
BIN1: XX-XX-X-XXX-X
LX XXXX
Semiconductors tors ors r
RoHS Compliant
(6P) BATCH NO: NO:: 1234567 1234567890 234 4 7890 8 890
ML Temp ST X XXX °C X
(1T) LOT NO: 1234567890
(9D) ((9D 9D D) D/C: D) D/C D : 123 D/ 1234 23 234 34
RXX Pack: R RX XX DEMY Y
XXX XXX
X_X123_1234.1234 X_X123_1 12 _123 123 12 234.1234 X
(X) PROD NO: 123456789(Q)QTY:
9999
(G) GROUP:
XX-XX-X-X XX-XX XX XXXX-X-X
OHA04563
Dry Packing Process and Materials Trockenverpackung und Materialien Moisture-sensitive label or print L VE LE
see labe
).
(RH
idity
˚C
<
40
. RH
hum 0% e tive ˚C/6 red kag rela 30 _ pac < infra of 90% to ak < ns ed (pe or ditio and ject ˚C, sing 5 con ±
N s IVE S Otain TOR SIT UC TI SEN ND U Econ As bag UR ICO CThiIST SEM
1.
sub ces be pro
ory
Barcode label
l k,
code blan If bar
˚C
e). cod date r
rs rs rs Hou rs Hou 72 Hou 48 Hou 24 6
time time
r time 23 will at l with fact r ent˚C). MO Floo . time TO at at r Floo l ths that tica d ival ure OP Floo 4 if: rea w Floo labe mon iden 5 ced equ el ices g, n e 5a is el belo or 24 pro Lev 6 dev : ntin el whe cod e , w, e Lev el see e bag Lev l date mou bak ned stur e Lev reflo bar re> 10% led stur e time sea for ope e Moi r see stur k, is . Moi sea is has k, stur befo d 033 Moi in Floo RH blan Moi or-p blan in bag Car ing, r TD(if life r . If with r lf 10%bak J-S thisvapp. Yea _ eks rs < r w, met cato 1 Yea tem d, She nted at uire not > y 1 WeHou DEC Afte Indi 4 uire reflo is bod Mou red req /JE time 168 req : 2b r a) Sto ices idity time is IPC r or time b) ned Floo r Hum ing ce time Dev 2a r Floo a) ope 3. b) bakren Floo 1 l date Floo If 2 refe time el 4. 2a el sea Lev 3 el and e Lev el Bag e e Lev stur e Lev Dat stur e Moi stur Moi stur Moi Moi
O S R A M
2.
Humidity indicator Barcode label Please check the HIC immidiately after bag opening. Discard if circles overrun. Avoid metal contact. Do not eat. Comparator check dot
WET
If wet, examine units, if necessary bake units
15%
If wet, examine units, if necessary bake units
10% 5%
If wet, parts still adequately dry. change desiccant Humidity Indicator MIL-I-8835
AM OSR
Desiccant
OHA00539
Note:
Moisture-sensitive product is packed in a dry bag containing desiccant and a humidity card. Regarding dry pack you will find further information in the internet and in the Short Form Catalog in chapter “Tape and Reel” under the topic “Dry Pack”. Here you will also find the normative references like JEDEC.
Anm.:
Feuchteempfindliche Produkte sind verpackt in einem Trockenbeutel zusammen mit einem Trockenmittel und einer Feuchteindikatorkarte. Bezüglich Trockenverpackung finden Sie weitere Hinweise im Internet und in unserem Short Form Catalog im Kapitel “Gurtung und Verpackung” unter dem Punkt “Trockenverpackung”. Hier sind Normenbezüge, unter anderem ein Auszug der JEDEC-Norm, enthalten.
2014-01-15
17
Version 1.4
LS H9PP
Transportation Packing and Materials Kartonverpackung und Materialien
8 Q-
1
R1
lti LS TO Y T6 PL 76
1+
Mu
P-
44
(9D )
4
20
23 3G
(6P )
LO T
00
D/C : 01
998
NO : 12
O
021
H1
210
BA TC H
Se SR mi AM co nd O uc pt to o rs NO
:
).
5 14 2 110 0
(Q) QT Y:
see labe
N
(1T )
O
NO :
TI
PR OD
U
(X)
A
(G)
l k,
C
GR OU P:
Muster
L VE LE
code (RH blan If y bar . idit RH hum e 60% tive d ˚C/ kag rela are 30 E S s _ infr pac < OR of 90% to ak tainITIV urs CT < or e). ted (pe urs ons Ho con NS g urs SE DU Ho and jec ˚C, diti cod 72 sin Ho urs 5 e bag E ON 48 ˚C sub e Ho con ± ces is UR 24 6 dat e MIC 40 be tim ˚C h e ThISTSE pro < tory tim . or t wit 23 tim e at t will or fac . MO Flo al len ˚C) s tim TO at or at Flo d or ure iva el nth s tha OP ntic Flo 4 if: rea , Flo lab ow mo ice equ ced ide 5 el e 5a is ingen el or bel 24 pro 6 Lev e dev, : el e cod , unt wh Lev el re ow see bag Lev l dat mo re bak e bar ned Lev refl istu 10% re tim for sea istu ore> re Mo see 3 istu is or . sea is Mo bef nk, istu pha nk, Flo , rd -03 Mo in RH bla Mo orbag ingCa bla hin TD life (if ar If wit t. vapp. 10%baktor J-S this elf Ye ar eks , _ < ed ica med, C 1 urs Ye erow tem Sh at uire not > y 1 WeHo DE unt Aft Ind 1. e 4 uire refl red req 2. bod Mo e ity is /JE tim 168 req : e 2b a) Sto es tim or mid is IPC or tim e vic ned b) or Hu Flo tim ing ce or e De 2a Flo a) ope or 3. b) bakren Flo e 1 l dat Flo If 2 el refe tim 2a 4. el sea 3 Lev g el and Lev el re Ba te Lev re Lev istu Da re istu re Mo istu Mo istu Mo Mo
DE
8 Q-
1
R1
lti LS TO Y T6 PL 76
1+ PP: OU GR
(G)
: 01
O SR AM
rs
D/C
to
)
uc
(9D
00
nd
21 00 21 99 8 :
4
20
NO
23
QT
(Q)
O SR m A ico M
H
H1
TC BA
3G
)
: 12
(6P
(X)
PR
OD
NO
:
(1T
)
11 00
LO
T
14 2
NO
5
Se
Y:
O pt o
44
Mu
MY
ED Bin Bin 1: Bin 2: P-1 3: Q-1 -20 ML -20 2 Te 2a 220 mp 3 240 ST Ad 260 C R C R0 diti R ona C RT PA 77 l TE CK VA XT R:
ope se
Muster
led
DE MY
Barcode label
ED Bin Bin 1: Bin 2: P-1 3: Q-1 -20 ML -20 2 Tem 2a 220 3 240 p ST Ad 260 C R C R0 diti R ona C RT PA 77 l TE CK VA XT R:
Barcode label
Packing Sealing label
OHA02044
Dimensions of transportation box in mm (inch): Width / Breite
Length / Länge
Height / Höhe
195 ± 5 (7.677 ± 0.1968)
195 ± 5 (7.677 ± 0.1968)
30 ± 5 (1.181 ± 0.196)
2014-01-15
18
Version 1.4
LS H9PP
Notes
Hinweise
The evaluation of eye safety occurs according to the standard IEC 62471:2008 ("photobiological safety of lamps and lamp systems"). Within the risk grouping system of this CIE standard, the LED specified in this data sheet fall into the class Exempt group (exposure time 10000 s). Under real circumstances (for exposure time, eye pupils, observation distance), it is assumed that no endangerment to the eye exists from these devices. As a matter of principle, however, it should be mentioned that intense light sources have a high secondary exposure potential due to their blinding effect. As is also true when viewing other bright light sources (e.g. headlights), temporary reduction in visual acuity and afterimages can occur, leading to irritation, annoyance, visual impairment, and even accidents, depending on the situation.
Die Bewertung der Augensicherheit erfolgt nach dem Standard IEC 62471:2008 ("photobiological safety of lamps and lamp systems"). Im Risikogruppensystem dieser CIE- Norm erfüllen die in diesem Datenblatt angegebenen LEDs folgende Gruppenanforderung - Exempt group (Expositionsdauer 10000 s). Unter realen Umständen (für Expositionsdauer, Augenpupille, Betrachtungsabstand) geht damit von diesen Bauelementen keinerlei Augengefährdung aus. Grundsätzlich sollte jedoch erwähnt werden, dass intensive Lichtquellen durch ihre Blendwirkung ein hohes sekundäres Gefahrenpotenzial besitzen. Nach einem Blick in eine helle Lichtquelle (z.B. Autoscheinwerfer), kann ein temporär eingeschränktes Sehvermögen oder auch Nachbilder zu Irritationen, Belästigungen, Beeinträchtigungen oder sogar Unfällen führen.
Subcomponents of this LED contain, among other substances, goldplated and Ag-filled materials. In spite of the improved corrosion stability of this LED, it can be affected by environments that contain very high concentrations of aggressive substances. Therefore, we recommend avoiding aggressive atmospheres during storage, production and use.
Einzelkomponenten dieser LED enthalten u.a. goldbeschichtete und Ag-gefüllte Materialien. Trotz der verbesserten Korrosionsstabilität dieser LED können Einzelkomponenten durch sehr hohe Konzentration aggressiver Substanzen angegriffen werden. Aus diesem Grund wird empfohlen, aggressive Umgebungen während der Lagerung, Produktion und im Betrieb zu vermeiden.
For further application related informations please visit www.osram-os.com/appnotes
Für weitere applikationsspezifische Informationen besuchen Sie bitte www.osram-os.com/appnotes
2014-01-15
19
Version 1.4
LS H9PP
Disclaimer
Disclaimer
Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. If printed or downloaded, please find the latest version in the Internet. Packing Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components* may only be used in life-support devices** or systems with the express written approval of OSRAM OS.
Bitte beachten! Lieferbedingungen und Änderungen im Design vorbehalten. Aufgrund technischer Anforderungen können die Bauteile Gefahrstoffe enthalten. Für weitere Informationen zu gewünschten Bauteilen, wenden Sie sich bitte an unseren Vertrieb. Falls Sie dieses Datenblatt ausgedruckt oder heruntergeladen haben, finden Sie die aktuellste Version im Internet. Verpackung Benutzen Sie bitte die Ihnen bekannten Recyclingwege. Wenn diese nicht bekannt sein sollten, wenden Sie sich bitte an das nächstgelegene Vertriebsbüro. Wir nehmen das Verpackungsmaterial zurück, falls dies vereinbart wurde und das Material sortiert ist. Sie tragen die Transportkosten. Für Verpackungsmaterial, das unsortiert an uns zurückgeschickt wird oder das wir nicht annehmen müssen, stellen wir Ihnen die anfallenden Kosten in Rechnung. Bauteile, die in lebenserhaltenden Apparaten und Systemen eingesetzt werden, müssen für diese Zwecke ausdrücklich zugelassen sein! Kritische Bauteile* dürfen in lebenserhaltenden Apparaten und Systemen** nur dann eingesetzt werden, wenn ein schriftliches Einverständnis von OSRAM OS vorliegt.
*) A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or system. **) Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health and the life of the user may be endangered.
*) Ein kritisches Bauteil ist ein Bauteil, das in lebenserhaltenden Apparaten oder Systemen eingesetzt wird und dessen Defekt voraussichtlich zu einer Fehlfunktion dieses lebenserhaltenden Apparates oder Systems führen wird oder die Sicherheit oder Effektivität dieses Apparates oder Systems beeinträchtigt. **) Lebenserhaltende Apparate oder Systeme sind für (a) die Implantierung in den menschlichen Körper oder (b) für die Lebenserhaltung bestimmt. Falls Sie versagen, kann davon ausgegangen werden, dass die Gesundheit und das Leben des Patienten in Gefahr ist.
2014-01-15
20
Version 1.4
LS H9PP
Glossary
Glossar
1)
Brightness: Brightness values are measured during a current pulse of typically 25 ms, with an internal reproducibility of ± 8 % and an expanded uncertainty of ± 11 % (acc. to GUM with a coverage factor of k = 3).
1)
Helligkeit: Helligkeitswerte werden während eines Strompulses einer typischen Dauer von 25 ms, mit einer internen Reproduzierbarkeit von ± 8 % und einer erweiterten Messunsicherheit von ± 11 % gemessen (gemäß GUM mit Erweiterungsfaktor k = 3).
2)
Wavelength: The wavelength is measured at a current pulse of typically 25 ms, with an internal reproducibility of ± 0.5 nm and an expanded uncertainty of ± 1 nm (acc. to GUM with a coverage factor of k = 3).
2)
Wellenlänge: Die Wellenläge wird während eines Strompulses einer typischen Dauer von 25 ms, mit einer internen Reproduzierbarkeit von ± 0,5 nm und einer erweiterten Messunsicherheit von ± 1 nm gemessen (gemäß GUM mit Erweiterungsfaktor k = 3).
3)
Forward Voltage: The forward voltage is measured during a current pulse of typically 8 ms, with an internal reproducibility of ± 0.05 V and an expanded uncertainty of ± 0.1 V (acc. to GUM with a coverage factor of k = 3).
3)
Durchlassspannung: Vorwärtsspannungen werden während eines Strompulses einer typischen Dauer von 8 ms, mit einer internen Reproduzierbarkeit von ± 0,05 V und einer erweiterten Messunsicherheit von ± 0,1 V gemessen (gemäß GUM mit Erweiterungsfaktor k = 3).
4)
Thermal Resistance: Rth max is based on statistic values (6σ).
4)
Wärmewiderstand: Rth statistischen Werten (6σ).
5)
Typical Values: Due to the special conditions of the manufacturing processes of LED, the typical data or calculated correlations of technical parameters can only reflect statistical figures. These do not necessarily correspond to the actual parameters of each single product, which could differ from the typical data and calculated correlations or the typical characteristic line. If requested, e.g. because of technical improvements, these typ. data will be changed without any further notice.
5)
Typische Werte: Wegen der besonderen Prozessbedingungen bei der Herstellung von LED können typische oder abgeleitete technische Parameter nur aufgrund statistischer Werte wiedergegeben werden. Diese stimmen nicht notwendigerweise mit den Werten jedes einzelnen Produktes überein, dessen Werte sich von typischen und abgeleiteten Werten oder typischen Kennlinien unterscheiden können. Falls erforderlich, z.B. aufgrund technischer Verbesserungen, werden diese typischen Werte ohne weitere Ankündigung geändert.
6)
Relative Brightness Curve: In the range where the line of the graph is broken, you must expect higher brightness differences between single LEDs within one packing unit.
6)
Relative Helligkeitskurve: Im gestrichelten Bereich der Kennlinien muss mit erhöhten Helligkeitsunterschieden zwischen Leuchtdioden innerhalb einer Verpackungseinheit gerechnet werden.
7)
Tolerance of Measure: Dimensions are specified as follows: mm (inch). Unless otherwise noted in drawing, tolerances are specified with ±0,1 (0,004)
7)
Maßtoleranz: Maße werden wie folgt angegeben: mm (inch). Wenn in der Zeichnung nicht anders angegeben, gilt eine Toleranz von ±0,1 (0,004).
2014-01-15
21
max
basiert
auf
Version 1.4
LS H9PP
Published by OSRAM Opto Semiconductors GmbH Leibnizstraße 4, D-93055 Regensburg www.osram-os.com © All Rights Reserved.
2014-01-15
22