Transcript
2012-07-31
OSLON Datasheet Version 1.0 LUW CN5M
Features:
Besondere Merkmale:
• Package: SMD ceramic package with silicone resin with lens • Technology: ThinGaN • Viewing angle at 50 % IV: (typ.) 60° • Color: Cx = 0.31, Cy = 0.32 acc. to CIE 1931 (ultra white) • Optical efficiency (typ.): 73 lm/W (ultra white)
• Gehäusetyp: SMD Keramik Gehäuse mit Silikonverguss und Linse • Technologie: ThinGaN • Abstrahlwinkel bei 50 % IV: (typ.) 60° • Farbe: Cx = 0.31, Cy = 0.32 acc. to CIE 1931 (ultra weiss) • Optischer Wirkungsgrad (typ.): 73 lm/W (ultra weiss) • ESD - Festigkeit: 2 kV nach JESD22-A114-F
• ESD - withstand voltage: 2 kV acc. to JESD22-A114-F • Corrosion Robustness: Improved corrosion robustness
• Korrosionsstabilität: Verbesserte Korrosionsstabilität
Applications • • • • •
Anwendungen
Day time running light LCD Backlighting Headup Display Automotive Interior Lighting Dashboard Backlighting
2012-07-31
• • • • •
1
Tagfahrlicht LCD Beleuchtung Headup Display Automobilbeleuchtung innen Instrumentenbeleuchtung
Version 1.0
LUW CN5M
Ordering Information Bestellinformation Type
Luminous Flux 1) page 20
Ordering Code
Typ
Lichtstrom 1) Seite 20
Bestellnummer
LUW CN5M-GAHA-5P7R-1
18 ... 35.5
ΦV [lm]
Note:
Q65110A8682
The above Type Numbers represent the order groups which include only a few brightness groups (see page for explanation). Only one group will be shipped on each packing unit (there will be no mixing of two groups on each packing unit). E. g. LUW CN5M-GAHA-5P7R-1 means that only one group GA, GB, HA will be shippable for any packing unit. In order to ensure availability, single brightness groups will not be orderable. In a similar manner for colors where color chromaticity coordinate groups are measured and binned, single groups will be shipped on any one packing unit. LUW CN5M-GAHA-5P7R-1 means that the device will be shipped within the specified limits as stated on page In order to ensure availability, single color chromaticity groups groups will not be orderable (see page for explanation). In a similar manner for colors where forward voltage groups are measured and binned, single forward voltage groups will be shipped on any packing unit. E. g. LUW CN5M-GAHA-5P7R-1 means that only one forward voltage group 4,5,6 will be shippable. In order to ensure availability, single forward voltage groups will not be orderable (see page for explanation).
Anm.:
Die oben genannten Typbezeichnungen umfassen die bestellbaren Selektionen. Diese bestehen aus wenigen Helligkeitsgruppen (siehe Seite für nähere Informationen). Es wird nur eine einzige Helligkeitsgruppe pro Verpackungseinheit geliefert. Z. B. LUW CN5M-GAHA-5P7R-1 bedeutet, dass in einer Verpackungseinheit nur eine der Helligkeitsgruppen GA, GB, HA enhalten ist. Um die Liefersicherheit zu gewährleisten, können einzelne Helligkeitsgruppen nicht bestellt werden. Gleiches gilt für die Farben, bei denen Farbortgruppen gemessen und gruppiert werden. Pro Verpackungseinheit wird nur eine Farbortgruppe geliefert. Z.B. LUW CN5M-GAHA-5P7R-1 bedeutet, dass in einer Verpackungseinheit nur eine der Farbortgruppen enthalten ist (siehe Seite für nähere Informationen). LUW CN5M-GAHA-5P7R-1 bedeutet, dass das Bauteil innerhalb der auf Seite spezifizierten Grenzen geliefert wird. Um die Liefersicherheit zu gewährleisten, können einzelne Farbortgruppen nicht bestellt werden. Gleiches gilt für die LEDs, bei denen die Durchlassspannungsgruppen gemessen und gruppiert werden. Pro Verpackungseinheit wird nur eine Durchlassspannungsgruppe geliefert. Z. B. LUW CN5M-GAHA-5P7R-1 bedeutet, dass nach Durchlassspannungsgruppen gruppiert wird. In einer Verpackungseinheit ist nur eine der Durchlassspannungsgruppen 4,5,6 enthalten (siehe Seite für nähere Informationen). Um die Liefersicherheit zu gewährleisten, können einzelne Durchlassspannungsgruppen nicht direkt bestellt werden.
2012-07-31
2
Version 1.0
LUW CN5M
Maximum Ratings Grenzwerte Parameter
Symbol
Values
Unit
Bezeichnung
Symbol
Werte
Einheit
Operating temperature range Betriebstemperatur
Top
-40 ... 125
°C
Storage temperature range Lagertemperatur
Tstg
-40 ... 125
°C
Junction Temperature Sperrschichttemperatur
Tj
150
°C
Forward current Durchlassstrom (TS = 25 °C)
IF
30 ... 250
mA
Surge current Stoßstrom (t <= 10 μs; D = 0.005; TS = 25 °C)
IFM
1000
mA
Reverse voltage Sperrspannung (TS = 25 °C)
VR
not designed for reverse operation
2012-07-31
3
V
Version 1.0
LUW CN5M
Characteristics (TS = 25 °C; IF = 140 mA) Kennwerte Parameter
Symbol
Values
Unit
Bezeichnung
Symbol
Werte
Einheit
Chromaticity coordinates acc. to CIE 1931
(typ.) (typ.)
Cx Cy
0.31 0.32
-
Viewing angle at 50 % IV Abstrahlwinkel bei 50 % IV
(typ.)
2ϕ
60
°
Forward voltage 3) page 20 Durchlassspannung 3) Seite 20
(min.) (typ.) (max.)
VF VF VF
2.90 3.20 3.80
V V V
Real thermal resistance junction / solder point
(typ.) (max.)
Rth JS real Rth JS real
2) page 20
Farbkoordinaten nach CIE 1931 2) Seite 20
4) page 20
Realer Wärmewiderstand Sperrschicht / Lötpad 4) Seite 20
2012-07-31
4
27 30
K/W K/W
Version 1.0
LUW CN5M
Brightness Groups Helligkeits-Gruppierungsschema Group
Luminous Flux
Luminous Flux
1) page 20
1) page 20
1) Seite 20
Lichtstrom
1) Seite 20
Luminous Intensity 5) page 20
Lichtstärke 5) Seite 20
Gruppe
Lichtstrom
(min.) ΦV [lm]
(max.) ΦV [lm]
(typ.) IV [cd]
GA
18
22.4
14.1
GB
22.4
28
17.6
HA
28
35.5
22.2
Note:
The standard shipping format for serial types includes either a lower family group, an upper family group or a grouping of all individual brightness groups of only a few brightness groups. Individual brightness groups cannot be ordered.
Anm.:
Die Standardlieferform von Serientypen beinhaltet entweder eine untere Familiengruppe, eine obere Familiengruppe oder eine Sammelgruppe, die aus nur wenigen Helligkeitsgruppen bestehen. Einzelne Helligkeitsgruppen sind nicht bestellbar.
Forward Voltage Groups 3) page 20 Durchlassspannungsgruppe 3) Seite 20 Group Gruppe
(min.) VF [V]
(max.) VF [V]
4
2.90
3.20
5
3.20
3.50
6
3.50
3.80
2012-07-31
5
Version 1.0
LUW CN5M
Chromaticity coordinate groups 2) page 20 Farbortgruppen 2) Seite 20 0.39 Cy
0.38 0.37
0.9
520
7R
530
Cy 0.8
0.36
540 510
550
0.7
7Q
0.35 7P
560
0.6
570
6R
500
0.5 0.4
580 590 600 610 620 630
E
0.3
490
0.2
0.33
0
+
6Q
0.32 6P
0.31
5R
0.30
480 470 460 450
0.1 0
0.34
5Q
0.29
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Cx
5P
0.28
0.35
0.34
0.32
0.33
0.31
0.29
0.28
0.26
0.30
0.27
Cx
Color Chromaticity Groups Farbortgruppen 2) Seite 20 Group Gruppe 5P
6P
7P
2012-07-31
OHA03489
2) page 20
Cx
Cy
0.2930
0.2824
0.2962
0.2756
0.3072
0.3111
0.3090
0.3019
0.3072
0.3111
0.3090
Group Gruppe 5Q
Cx
Cy
0.2889
0.2910
0.2930
0.2824
0.3049
0.3223
Group Gruppe 5R
Cy
0.2889
0.2910
0.3035
0.3293
0.3049
0.3223
0.3072
0.3111
0.3035
0.3293
0.3049
0.3223
0.3049
0.3223
0.3019
0.3072
0.3111
0.3170
0.3459
0.3170
0.3182
0.3170
0.3309
0.3170
0.3309
0.3170
0.3459
0.3170
0.3182
0.3170
0.3170
0.3309
0.3170
0.3341
0.3652
0.3375
0.3601
6Q
7Q
5R
6R
Cx
0.3170
0.3556
0.3170
0.3556
0.3309
0.3220
0.3653
0.3556
0.3300
0.3728
0.3341
0.3652
0.3341
0.3652
0.2865
0.2960
6
7R
Version 1.0
LUW CN5M
Group Name on Label Gruppenbezeichnung auf Etikett Example: GA-5P-4 Beispiel: GA-5P-4 Brightness Helligkeit
Chromaticity Coordinate Farbort
Forward Voltage Durchlassspannung
GA
5P
4
Note:
No packing unit / tape ever contains more than one group for each selection.
Anm.:
In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe für jede Selektion enthalten.
2012-07-31
7
Version 1.0
LUW CN5M
Relative Spectral Emission - V(λ) = Standard eye response curve 5) page 20 , 1) page 20 Relative spektrale Emission - V(λ) = spektrale Augenempfindlichkeit 5) Seite 20 , 1) Seite 20 Φrel = f (λ); TS = 25 °C; IF = 140 mA
OHL13926
100 %
Φrel 80
Vλ 60
40
20
0 400
450
500
550
600
650
700
nm 750
λ
Radiation Characteristics 5) page 20 Abstrahlcharakteristik 5) Seite 20 Irel = f (ϕ); TS = 25 °C
2012-07-31
8
Version 1.0
LUW CN5M
Forward Current 5) page 20 Durchlassstrom 5) Seite 20
Relative Luminous Flux 5) page 20 , 6) page 20 Relativer Lichtstrom 5) Seite 20 , 6) Seite 20
IF = f (VF); TS = 25 °C
IF
ΦV/ΦV(140 mA) = f(IF); TS = 25 °C OHL04295
250 mA 200
150
100
50
0 2.7
2.9
3.1
3.3
V 3.5
VF
Chromaticity Coordinate Shift 5) page 20 Farbortverschiebung 5) Seite 20 ΔCx, ΔCy = f(IF); TS = 25 °C
2012-07-31
9
Version 1.0
LUW CN5M
Relative Forward Voltage 5) page 20 Relative Vorwärtsspannung 5) Seite 20
Relative Luminous Flux 5) page 20 Relative Lichtstrom 5) Seite 20
ΔVF = VF - VF(25°C) = f(Tj); IF = 140 mA
ΔVF
ΦV/ΦV(25 °C) = f(Tj); IF = 140 mA
OHL04068
0.4 V
OHL14202
1.2
ΦV Φ V (25 ˚C)
0.2
0.8 0.1
0.6
0 -0.1
0.4
-0.2
0.2 -0.3 -0.4 -40 -20 0
20 40 60 80
0 -40 -20 0
˚C 120
Chromaticity Coordinate Shift 5) page 20 Farbortverschiebung 5) Seite 20 ΔCx, ΔCy = f(Tj); IF = 140 mA
2012-07-31
20 40 60 80
˚C 120
Tj
Tj
10
Version 1.0
LUW CN5M
Max. Permissible Forward Current Maximal zulässiger Durchlassstrom IF = f (T)
Permissible Pulse Handling Capability Zulässige Impulsbelastbarkeit IF = f(tp)
Permissible Pulse Handling Capability Zulässige Impulsbelastbarkeit IF = f(tp)
D: Duty cycle, TS = 25 °C
2012-07-31
D: Duty cycle, TS = 85 °C
11
Version 1.0
LUW CN5M
Package Outline 7) page 20 Maßzeichnung 7) Seite 20
Approximate Weight:
24 mg
Gewicht:
24 mg
Mark:
Cathode
Markierung:
Kathode
Corrosion robustness:
Test conditions: 40 °C / 90 % rh / 15 ppm H2S / 336 h = Stricter than IEC 60068-2-43 (H2S) [25°C / 75 % rh / 10 ppm H2S / 21 days] = Regarding relevant gas (H2S) stricter than EN 60068-2-60 (method 4) [25 °C / 75 % rh / 200 ppb SO2, 200 ppb NO2,10 ppb Cl2 / 21 days]
Korrosionsfestigkeit:
Test Kondition: 40°C / 90 % rh / 15 ppm H2S / 336 h = Besser als IEC 60068-2-43 (H2S) [25°C / 75 % rh / 10 ppm H2S / 21 Tage] = Bezogen auf das Gas (H2S) besser als EN 60068-2-60 (method 4) [25°C / 75 % rh / 200ppb SO2, 200ppb NO2,10ppb Cl2 / 21 Tage]
2012-07-31
12
Version 1.0
LUW CN5M
Recommended Solder Pad 7) page 20 Empfohlenes Lötpaddesign 7) Seite 20
2012-07-31
Reflow soldering Reflow-Löten
13
Version 1.0
LUW CN5M
Reflow Soldering Profile Reflow Lötprofil
Preconditioning JEDEC Level 1 acc. to J-STD-020D.01 OHA04525
300 ˚C
T 250
Tp 245 ˚C
240 ˚C
tP
217 ˚C 200
tL
150
tS
100
50 25 ˚C 0
0
50
100
150
200
s 300
250
t
OHA04612
Profil-Charakteristik Profile Feature
Symbol Symbol
Pb-Free (SnAgCu) Assembly Minimum
Ramp-up Rate to Preheat*) 25 °C to 150 °C Time tS TSmin to TSmax
tS
60
Ramp-up Rate to Peak*) TSmax to TP
Recommendation
Maximum
2
3
100
120
2
3
Einheit Unit K/s s K/s
Liquidus Temperature
TL
217
Time above Liquidus temperature
tL
80
100
s
Peak Temperature
TP
245
260
°C
Time within 5 °C of the specified peak temperature TP - 5 K
tP
20
30
s
3
6
K/s
10
Ramp-down Rate* TP to 100 °C
480
Time 25 °C to TP All temperatures refer to the center of the package, measured on the top of the component * slope calculation DT/Dt: Dt max. 5 s; fulfillment for the whole T-range
2012-07-31
°C
14
s
Version 1.0
LUW CN5M
Method of Taping 7) page 20 Gurtung 7) Seite 20
2012-07-31
15
Version 1.0
LUW CN5M
Tape and Reel Gurtverpackung 12 mm tape with 600 pcs. on ∅ 180 mm reel, 3000 pcs. on ∅ 330 mm reel W1 D0
P0
A N
F W
E
13.0 ±0.25
P2
Label
P1 Direction of unreeling
Direction of unreeling W2
Gurtvorlauf: 400 mm Leader: 400 mm Gurtende: Trailer:
160 mm 160 mm
OHAY0324
Tape dimensions in mm (inch) Tape dimensions in mm (inch)
W
P0
P1
P2
D0
E
F
12 +0.3/-0.1
4 ± 0.1 (0.157 ± 0.004)
4 ± 0.1 (0.157 ± 0.004) or 8 ± 0.1 (0.315 ± 0.004)
2 ± 0.05 (0.079 ± 0.002)
1.5 ± 0.1 (0.059 + 0.004)
1.75 ± 0.1 (0.069 ± 0.004)
5.5 ± 0.05 (0.217 ± 0.002)
Reel dimensions in mm (inch) Reel dimensions in mm (inch)
A
W
Nmin
W1
W2max
180 (7)
12 (0.472)
60 (2.362)
12.4 + 2 (0.488 + 0.079)
18.4 (0.724)
Reel dimensions in mm (inch)
A
W
Nmin
W1
W2max
330 (13)
12 (0.472)
60 (2.362)
12.4 + 2 (0.488 + 0.079)
18.4 (0.724)
2012-07-31
16
Version 1.0
LUW CN5M
Barcode-Product-Label (BPL) Barcode-Produkt-Etikett (BPL) OSRAM Opto
BIN1: XX-XX-X-XXX-X
LX XXXX
Semiconductors
RoHS Compliant
(6P) BATCH NO: 1234567890
ML Temp ST 2 260 °C R (1T) LOT NO: 1234567890
(9D) D/C: 1234 Pack: R18 DEMY
022
B_R999_1880.1642 R (X) PROD NO: 123456789(Q)QTY:
9999
(G) GROUP:
XX-XX-X-X
OHA04563
Dry Packing Process and Materials Trockenverpackung und Materialien Moisture-sensitive label or print L VE LE
l k,
see labe
code blan If bar
).
(RH . RH
idity
hum 0% e tive ˚C/6 red kag S rela 30 s pac _ < infra IVE of TOR rs tain 90% to ak SIT rs < ns ed (pe UC e). or rs con Hou SEN rs Hou ND and ject ditio cod ˚C, 72 sing Hou e 5 bag E 48 ˚C sub Hou con ± s UR ICO ces 24 6 dat 40 be time ˚C ory ThiISTSEM r pro < time r 23 time at t will ˚C). l with fact r ent MO . Floo time TO at at r Floo l ths tha tica d ival ure OP Floo 4 if: rea w Floo labe mon iden 5 ced equ el ices g, n e 5a is el belo or 24 pro 6 Lev e dev : ntin el whe cod e , w, e Lev el see e bag Lev l dat mou bak bar ned stur e Lev reflo 10% led stur e time sea for ore> ope e Moi r see stur k, is . sea is has k, Moi stur bef d 033 Moi in Floo RH blan Moi or-p blan in bag Car ing, r TD(if life . If r lf J-S thisvapp. d with 10%bak or Yea _ eks rs < r w, icat met 1 Yea tem d, She at nte uire not > y 1 WeHou DEC Afte Ind 4 uire reflo is bod Mou red req /JE time 168 req : 2b r a) Sto ices idity time is IPC r or time b) ned Floo r Hum ing ce time Dev 2a e r Floo a) ope 3. b) bakren Floo 1 l dat Floo If 2 refe time el 4. 2a el sea 3 Lev el and e Lev el Bag e e Lev stur e Lev Dat stur e Moi stur Moi stur Moi Moi
C
1.
U A
TI
Barcode label
N O
O
S
R
A
M
2.
Humidity indicator Barcode label Please check the HIC immidiately after bag opening. Discard if circles overrun. Avoid metal contact. Do not eat. Comparator check dot
WET
If wet, examine units, if necessary bake units
15%
If wet, examine units, if necessary bake units
10% 5%
If wet, parts still adequately dry. change desiccant Humidity Indicator MIL-I-8835
AM
Desiccant
OSR
OHA00539
Note:
Moisture-sensitive product is packed in a dry bag containing desiccant and a humidity card. Regarding dry pack you will find further information in the internet and in the Short Form Catalog in chapter “Tape and Reel” under the topic “Dry Pack”. Here you will also find the normative references like JEDEC.
Anm.:
Feuchteempfindliche Produkte sind verpackt in einem Trockenbeutel zusammen mit einem Trockenmittel und einer Feuchteindikatorkarte. Bezüglich Trockenverpackung finden Sie weitere Hinweise im Internet und in unserem Short Form Catalog im Kapitel “Gurtung und Verpackung” unter dem Punkt “Trockenverpackung”. Hier sind Normenbezüge, unter anderem ein Auszug der JEDEC-Norm, enthalten.
2012-07-31
17
Version 1.0
LUW CN5M
Transportation Packing and Materials Kartonverpackung und Materialien
Barcode label
MY DE
8 Q-
1
R1
lti LS TO Y T6 PL 76
1+
Mu
POU GR
44
D/C ) (9D
4
20
23
Y:
QT
H1
TC
BA
3G
)
: 12
(6P
00
: 01
998 021 210
O
Se SR mi AM co nd O uc pt to o H rs NO
:
).
5 14 2 110 0
(X)
PR
OD
NO
:
(1T
)
LO
T
NO
see labe
(G)
l k,
N O TI U A C
(Q)
L VE LE
code (RH blan If y bar . idit RH hum 60% e tive d ˚C/ kag rela are 30 E S s _ < infr pac OR of tainITIV 90% to ak urs CT < e). or urs ted (pe ons con NS Ho g urs SE DU Ho and jec diti cod ˚C, 72 sin Ho urs e 5 bag E ON 48 ˚C sub e Ho con ± s UR ces 24 6 dat e MIC 40 be tim ˚C e ThiISTSE pro < tory tim . or t with 23 tim e at t will ˚C) or fac MO . Flo al len tim TO s at or at Flo d or iva ure el nth s tha OP ntic Flo 4 if: rea Flo , lab ow mo ice equ ide 5 ced el e 5a is el ingen bel or 24 pro 6 Lev e dev, : el cod e , unt wh Lev el re ow see bag Lev l dat re mo bak e bar ned Lev refl istu 10% re tim sea for istu ore> re ope e Mo see 3 istu is or . sea is has Mo nk, bef istu nk, Flo , rd -03 Mo in RH bla Mo or-p bla in bag ingCa r TD life (if If with t. r lf vapp. 10%baktor J-S this Yea , _ eks < r ed ica med, C 1 urs Yea tem She ow at uire not > y 1 WeHo unt DE Afte Ind 1. e 4 uire refl red req 2. bod Mo e ity is /JE tim s 168 req : e 2b a) Sto tim or mid is IPC tim e vice or b) or ned Flo Hu tim ing ce or De e 2a Flo a) ope or 3. b) bakren Flo e 1 l dat Flo If 2 el refe tim 2a 4. el sea 3 Lev el and Lev el re Bag te Lev re Lev istu Da re istu re Mo istu Mo istu Mo Mo
P:
Muster
ED Bin Bin 1: Bin 2: P-1 3: Q-1 -20 ML -20 2 Tem 2a 220 3 240 p ST Ad 260 C R C R0 diti R ona C RT PA 77 l TE CK VA XT R:
Barcode label
MY DE
8
1 Q-
R1
lti LS TO Y T6 PL 76
1+ P-
Mu
8
: 01
O SR AM
99
D/C )
21 00
(9D
21 :
4
20 00
Y:
O
H1 23
TC
) (6P
(Q)
(X)
PR
OD
NO
:
(1T
)
11 00
LO
T
14 2
NO
5
: 12
BA
3G
QT
Se SR m A ico M nd O uc pt to o H rs NO
44
(G)
GR
OU
P:
Muster
ED Bin Bin 1: Bin 2: P-1 3: Q-1 -20 ML -20 2 Te 2a 220 mp 3 240 ST Ad 260 C R C R0 diti R ona C RT PA 77 l TE CK VA XT R:
led
Packing Sealing label
OHA02044
Dimensions of transportation box in mm (inch) Width / Breite
Length / Länge
Height / Höhe
195 ±5 (7,677 ±0,1968) 349 ±5 (13,740 ±0,196)
195 ±5 (7,677 ±0,1968) 349 ±5 (13,740 ±0,196)
30 ±5 (1,181 ±0,196) 33 ±5 (1,299 ±0,196)
Notes
Hinweise
The evaluation of eye safety occurs according to the standard IEC 62471:2006 ("photobiological safety of lamps and lamp systems"). Within the risk grouping system of this CIE standard, the LED specified in this data sheet fall into the class Low risk (exposure time 100 s). Under real circumstances (for exposure time, eye pupils, observation distance), it is assumed that no endangerment to the eye exists from these devices. As a matter of principle, however, it should be mentioned that intense light sources have a high secondary exposure potential due to their blinding effect. As is also true when viewing other bright light sources (e.g. headlights), temporary reduction in visual acuity and afterimages can occur, leading to irritation, annoyance, visual impairment, and even accidents, depending on the situation.
Die Bewertung der Augensicherheit erfolgt nach dem Standard IEC 62471:2006 ("photobiological safety of lamps and lamp systems"). Im Risikogruppensystem dieser CIE- Norm erfüllen die in diesem Datenblatt angegebenen LEDs folgende Gruppenanforderung - Low risk (Expositionsdauer 100 s). Unter realen Umständen (für Expositionsdauer, Augenpupille, Betrachtungsabstand) geht damit von diesen Bauelementen keinerlei Augengefährdung aus. Grundsätzlich sollte jedoch erwähnt werden, dass intensive Lichtquellen durch ihre Blendwirkung ein hohes sekundäres Gefahrenpotenzial besitzen. Nach einem Blick in eine helle Lichtquelle (z.B. Autoscheinwerfer), kann ein temporär eingeschränktes Sehvermögen oder auch Nachbilder zu Irritationen, Belästigungen, Beeinträchtigungen oder sogar Unfällen führen.
2012-07-31
18
Version 1.0
LUW CN5M
Disclaimer
Disclaimer
Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. If printed or downloaded, please find the latest version in the Internet. Packing Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components* may only be used in life-support devices** or systems with the express written approval of OSRAM OS.
Bitte beachten! Lieferbedingungen und Änderungen im Design vorbehalten. Aufgrund technischer Anforderungen können die Bauteile Gefahrstoffe enthalten. Für weitere Informationen zu gewünschten Bauteilen, wenden Sie sich bitte an unseren Vertrieb.Falls Sie diese Datenblatt ausgedruckt oder heruntergeladen haben, finden Sie die aktuellste Version im Internet. Verpackung Benutzen Sie bitte die Ihnen bekannten Recyclingwege. Wenn diese nicht bekannt sein sollten, wenden Sie sich bitte an das nächstgelegene Vertriebsbüro. Wir nehmen das Verpackungsmaterial zurück, falls dies vereinbart wurde und das Material sortiert ist. Sie tragen die Transportkosten. Für Verpackungsmaterial, das unsortiert an uns zurückgeschickt wird oder das wir nicht annehmen müssen, stellen wir Ihnen die anfallenden Kosten in Rechnung. Bauteile, die in lebenserhaltenden Apparaten und Systemen eingesetzt werden, müssen für diese Zwecke ausdrücklich zugelassen sein! Kritische Bauteile* dürfen in lebenserhaltenden Apparaten und Systemen nur dann eingesetzt werden, wenn ein schriftliches Einverständnis von OSRAM OS vorliegt.
*) A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or system. **) Life support devices or systems are intended(a) to be implanted in the human body,or(b) to support and/or maintain and sustain human life.If they fail, it is reasonable to assume that the health and the life of the user may be endangered.
*) Ein kritisches Bauteil ist ein Bauteil, das in lebenserhaltenden Apparaten oder Systemen eingesetzt wird und dessen Defekt voraussichtlich zu einer Fehlfunktion dieses lebenserhaltenden Apparates oder Systems führen wird oder die Sicherheit oder Effektivität dieses Apparates oder Systems beeinträchtigt. **) Lebenserhaltende Apparate oder Systeme sind für (a) die Implantierung in den menschlichen Körper oder (b) für die Lebenserhaltung bestimmt. Falls Sie versagen, kann davon ausgegangen werden, dass die Gesundheit und das Leben des Patienten in Gefahr ist.
2012-07-31
19
Version 1.0
LUW CN5M
Glossary
Glossar
1)
Brightness: Brightness values are measured during a current pulse of typical 25 ms, with an internal reproducibility of +/- 8 % and an expanded uncertainty of +/- 11 % (acc. to GUM with a coverage factor of k = 3).
1)
Helligkeit: Helligkeitswerte werden während eines Strompulses einer typischen Dauer von 25 ms, mit einer internen Reproduzierbarkeit von +/- 8 % und einer erweiterten Messunsicherheit von +/- 11 % gemessen (gemäß GUM mit Erweiterungsfaktor k = 3).
2)
Chromaticity coordinate groups: Chromaticity coordinates are measured during a current pulse of typical 25 ms, with an internal reproducibility of +/0,005 and an expanded uncertainty of +/- 0,01 (acc. to GUM with a coverage factor of k = 3).
2)
Farbortgruppen: Farbkoordinaten werden während eines Strompulses einer typischen Dauer von 25 ms, mit einer internen Reproduzierbarkeit von +/- 0,005 und einer erweiterten Messunsicherheit von +/- 0,01 gemessen (gemäß GUM mit Erweiterungsfaktor k = 3).
3)
Forward Voltage: The forward voltage is measured during a current pulse of typical 8 ms, with an internal reproducibility of +/- 0,05 V and an expanded uncertainty of +/- 0,1 V (acc. to GUM with a coverage factor of k=3).
3)
Durchlassspannung: Vorwärtsspannungen werden während eines Strompulses einer typischen Dauer von 8 ms, mit einer internen Reproduzierbarkeit von +/- 0,05 V und einer erweiterten Messunsicherheit von +/- 0,1 V gemessen (gemäß GUM mit Erweiterungsfaktor k=3).
4)
Thermal Resistance: Rth max based on statistic values (6ó)
4)
Wärmewiderstand: Rth statistischen Werten (6ó)
5)
Typical Values: Due to the special conditions of the manufacturing processes of LED, the typical data or calculated correlations of technical parameters can only reflect statistical figures. These do not necessarily correspond to the actual parameters of each single product, which could differ from the typical data and calculated correlations or the typical characteristic line. If requested, e.g. because of technical improvements, these typ. data will be changed without any further notice.
5)
Typische Werte: Wegen der besonderen Prozessbedingungen bei der Herstellung von LED können typische oder abgeleitete technische Parameter nur aufgrund statistischer Werte wiedergegeben werden. Diese stimmen nicht notwendigerweise mit den Werten jedes einzelnen Produktes überein, dessen Werte sich von typischen und abgeleiteten Werten oder typischen Kennlinien unterscheiden können. Falls erforderlich, z.B. aufgrund technischer Verbesserungen, werden diese typischen Werte ohne weitere Ankündigung geändert.
6)
Relative Brightness Curve: In the range where the line of the graph is broken, you must expect higher brightness differences between single LEDs within one packing unit.
6)
Relative Helligkeitskurve: Im gestrichelten Bereich der Kennlinien muss mit erhöhten Helligkeitsunterschieden zwischen Leuchtdioden innerhalb einer Verpackungseinheit gerechnet werden.
7)
Tolerance of Measure: Dimensions are specified as follows: mm (inch).
7)
Maßtoleranz: Maße angegeben: mm (inch).
2012-07-31
20
max
werden
basiert
wie
auf
folgt
Version 1.0
LUW CN5M
Published by OSRAM Opto Semiconductors GmbH Leibnizstraße 4, D-93055 Regensburg www.osram-os.com © All Rights Reserved.
2012-07-31