Transcript
2012-12-13
OSLON LX Datasheet Version 1.2 LUW CVBP.CE
OSLON LX
OSLON LX
Features:
Besondere Merkmale:
• Package: SMD ceramic package with silicone resin with lens • Technology: ThinGaN (UX:3) • Viewing angle at 50 % IV: 120° • Color: acc. to white area ECE/SAE • ESD - withstand voltage: 8 kV acc. to ANSI/ESDA/JEDEC JS-001 (HBM, Class 3B) • Corrosion Robustness: Improved corrosion robustness • Qualifications: The product qualification test plan is based on the guidelines of AEC-Q101-REV-C, Stress Test Qualification for Automotive Grade Discrete Semiconductors.
• Gehäusetyp: SMD Keramik Gehäuse mit Silikonverguss und Linse • Technologie: ThinGaN (UX:3) • Abstrahlwinkel bei 50 % IV: 120° • Farbe: acc. to white area ECE/SAE • ESD - Festigkeit: 8 kV nach ANSI/ESDA/JEDEC JS-001 (HBM, Klasse 3B) • Korrosionsstabilität: Verbesserte Korrosionsstabilität • Qualifikationen: Die Produktqualifikation wurde entsprechend der Richtlinie AEC-Q101-REV-C, „Stress Test Qualification for Automotive Grade Discrete Semiconductors“, getestet.
Applications • • • • • • •
Anwendungen
Bending light Day time running light Fog lamp Cornering light Back-up light Bicycle Lamps Working lamp
2012-12-13
• • • • • • •
1
Abbiegelicht Tagfahrlicht Nebelscheinwerfer Kurvenfahrlicht Rückfahrleuchte Fahrradlampe Arbeitsscheinwerfer
Version 1.2
LUW CVBP.CE
Ordering Information Bestellinformation Type:
Luminous Flux 1) page 21
Ordering Code
Typ:
Lichtstrom 1) Seite 21
Bestellnummer
IF = 350 mA ΦV [lm] LUW CVBP.CE-8K8L-GMKM-8E8H Note:
100 ... 180
Q65111A2762
The above Type Numbers represent the order groups which include only a few brightness groups (see page 5). Only one group will be shipped on each packing unit (there will be no mixing of two groups on each packing unit). E. g. LUW CVBP.CE-8K8L-GMKM-8E8H means that only one group 5L, 6L, 7L, 8K, 8L will be shippable for any packing unit. In order to ensure availability, single brightness groups will not be orderable. In a similar manner for colors where color chromaticity coordinate groups are measured and binned, single groups will be shipped on any one packing unit. LUW CVBP.CE-8K8L-GMKM-8E8H means that the device will be shipped within the specified limits. In order to ensure availability, single color chromaticity groups groups will not be orderable (see page 6). In a similar manner for colors where forward voltage groups are measured and binned, single forward voltage groups will be shipped on any packing unit. E. g. LUW CVBP.CE-8K8L-GMKM-8E8H means that only one forward voltage group 8E,8F,8G,8H will be shippable. In order to ensure availability, single forward voltage groups will not be orderable (see page 5).
Anm.:
Die oben genannten Typbezeichnungen umfassen die bestellbaren Selektionen. Diese bestehen aus wenigen Helligkeitsgruppen (siehe Seite 5). Es wird nur eine einzige Helligkeitsgruppe pro Verpackungseinheit geliefert. Z. B. LUW CVBP.CE-8K8L-GMKM-8E8H bedeutet, dass in einer Verpackungseinheit nur eine der Helligkeitsgruppen 5L, 6L, 7L, 8K, 8L enhalten ist. Um die Liefersicherheit zu gewährleisten, können einzelne Helligkeitsgruppen nicht bestellt werden. Gleiches gilt für die Farben, bei denen Farbortgruppen gemessen und gruppiert werden. Pro Verpackungseinheit wird nur eine Farbortgruppe geliefert. Z.B. LUW CVBP.CE-8K8L-GMKM-8E8H bedeutet, dass in einer Verpackungseinheit nur eine der Farbortgruppen enthalten ist (siehe Seite 6). LUW CVBP.CE-8K8L-GMKM-8E8H bedeutet, dass das Bauteil innerhalb der spezifizierten Grenzen geliefert wird. Um die Liefersicherheit zu gewährleisten, können einzelne Farbortgruppen nicht bestellt werden. Gleiches gilt für die LEDs, bei denen die Durchlassspannungsgruppen gemessen und gruppiert werden. Pro Verpackungseinheit wird nur eine Durchlassspannungsgruppe geliefert. Z. B. LUW CVBP.CE-8K8L-GMKM-8E8H bedeutet, dass nach Durchlassspannungsgruppen gruppiert wird. In einer Verpackungseinheit ist nur eine der Durchlassspannungsgruppen 8E,8F,8G,8H enthalten (siehe Seite 5). Um die Liefersicherheit zu gewährleisten, können einzelne Durchlassspannungsgruppen nicht direkt bestellt werden.
2012-12-13
2
Version 1.2
LUW CVBP.CE
Maximum Ratings Grenzwerte Parameter
Symbol
Values
Unit
Bezeichnung
Symbol
Werte
Einheit
Operating temperature range Betriebstemperatur
Top
-40 ... 125
°C
Storage temperature range Lagertemperatur
Tstg
-40 ... 125
°C
Junction temperature for short time applications * Sperrschichttemperatur für Kurzzeitanwendung *
Tj
175
°C
Junction temperature Sperrschichttemperatur
Tj
150
°C
Forward current Durchlassstrom (TS = 25 °C)
IF
100 ... 1000
mA
Surge current Stoßstrom (t <= 10 μs; D = 0.005; T S = 25 °C)
IFM
2000
mA
Reverse voltage Sperrspannung (TS = 25 °C)
VR
not designed for reverse operation
V
Note: *The LED chip exhibits excellent performance but slight package discoloration occurs at highest temperatures. Exemplary median lifetime for Tj = 175°C is 100h. Anm:
*Auch bei höchsten Temperaturen zeigt der LED Chip sehr gute Leistungsmerkmale, aber es kann eine leichte Verfärbung des Gehäuses auftreten. Die mittlere Lebensdauer bei Tj = 175°C beträgt 100h.
2012-12-13
3
Version 1.2
LUW CVBP.CE
Characteristics (TS = 25 °C; IF = 350 mA) Kennwerte Parameter
Symbol
Values
Unit
Bezeichnung
Symbol
Werte
Einheit
(typ.) (typ.)
Cx Cy
0.33 0.34
-
Viewing angle at 50 % IV Abstrahlwinkel bei 50 % IV
(typ.)
2ϕ
120
°
Forward voltage 3) page 21 Durchlassspannung 3) Seite 21
(min.) (typ.) (max.)
VF VF VF
2.75 2.95 3.75
V V V
IR
not designed for reverse operation
Chromaticity coordinates acc. to CIE 1931 2) page 21
Farbkoordinaten nach CIE 1931 2) Seite 21
Reverse current Sperrstrom Real thermal resistance junction / solder point
4) page 21
Realer Wärmewiderstand Sperrschicht / Lötpad
(typ.) (max.)
Rth JS real Rth JS real
12.8 18.3
K/W K/W
(typ.) (max.)
Rth JS el Rth JS el
9.1 13
K/W K/W
4) Seite 21
"Electrical" thermal resistance junction / solder point 4) page 21 "Elektrischer" Wärmewiderstand Sperrschicht / Lötpad 4) Seite 21 (with efficiency η e = 29 %) Note:
Individual forward voltage groups see next page
Anm.:
Durchlassspannungsgruppen siehe nächste Seite
2012-12-13
4
Version 1.2
LUW CVBP.CE
Brightness Groups Helligkeitsgruppen Group
Luminous Flux
Luminous Flux
1) page 21
1) page 21
1) Seite 21
Lichtstrom
1) Seite 21
Luminous Intensity 5) page 21
Lichtstärke 5) Seite 21
Gruppe
Lichtstrom
(min.) ΦV [lm]
(max.) Φ V [lm]
(typ.) IV [cd]
8K
100
112
35
5L
112
125
39.1
6L
125
140
43.7
7L
140
159
49.3
8L
159
180
55.9
Note:
The standard shipping format for serial types includes either a lower family group, an upper family group or a grouping of all individual brightness groups of only a few brightness groups. Individual brightness groups cannot be ordered.
Anm.:
Die Standardlieferform von Serientypen beinhaltet entweder eine untere Familiengruppe, eine obere Familiengruppe oder eine Sammelgruppe, die aus nur wenigen Helligkeitsgruppen bestehen. Einzelne Helligkeitsgruppen sind nicht bestellbar.
Forward Voltage Groups 3) page 21 Durchlassspannungsgruppe 3) Seite 21 Group Gruppe
(min.) VF [V]
(max.) VF [V]
8E
2.75
3.00
8F
3.00
3.25
8G
3.25
3.50
8H
3.50
3.75
2012-12-13
5
Version 1.2
LUW CVBP.CE
Chromaticity Coordinate Groups 2) page 21 Farbortgruppen 2) Seite 21 0.40 Cy 0.39 0.38 0.9
520
530
Cy 0.8
540 510
0.36
JM
550
0.7
0.35
560
0.6
IM
0.34
570 500
0.5
580 590 600 610 620 630
0.4 E
0.3
490
0.2
0
+
0.33
HM
0.32 GM
0.31 0.30
480 470 460 450
0.1 0
KM
0.37
FM
0.29 0.28
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Cx
EM
0.27
0.37
0.35
0.36
0.34
0.32
0.33
0.31
0.29
0.25
0.30
0.26
Cx
Color Chromaticity Groups Farbortgruppen 2) Seite 21 Group Gruppe GM
HM
2012-12-13
Cx
OHA04207
2) page 21
Cy
Group Gruppe IM
Cx
Cy
Group Gruppe
Cy
0.3086
0.3057
0.3246
0.3357
0.3406
0.3657
0.3086
0.3097
0.3246
0.3397
0.3406
0.3697
0.3166
0.3247
0.3326
0.3547
0.3486
0.3847
0.3178
0.3004
0.3338
0.3304
0.3498
0.3604
0.3198
0.3267
0.3358
0.3567
0.3518
0.3867
0.3290
0.3214
0.3450
0.3514
0.3610
0.3814
0.3166
0.3207
0.3326
0.3507
0.3166
0.3247
0.3326
0.3547
0.3246
0.3397
0.3406
0.3697
0.3258
0.3154
0.3418
0.3454
0.3278
0.3417
0.3438
0.3717
0.3370
0.3364
0.3530
0.3664
JM
6
KM
Cx
Version 1.2
LUW CVBP.CE
Group Name on Label Gruppenbezeichnung auf Etikett Example: 5L-GM-8E Beispiel: 5L-GM-8E Brightness Helligkeit
Chromaticity Coordinate Farbort
Forward Voltage Durchlassspannung
5L
GM
8E
Note:
No packing unit / tape ever contains more than one group for each selection.
Anm.:
In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe für jede Selektion enthalten.
2012-12-13
7
Version 1.2
LUW CVBP.CE
Relative Spectral Emission - V(λ) = Standard eye response curve 5) page 21 Relative spektrale Emission - V(λ) = spektrale Augenempfindlichkeit 5) Seite 21 Φrel = f (λ); TS = 25 °C; IF = 350 mA
Φrel
LUWCVBP.CE
1,0
: ultrawhite : Vλ
0,8
0,6
0,4
0,2
0,0 350
400
450
500
550
600
650
700
750
800
λ [nm]
Radiation Characteristics 5) page 21 Abstrahlcharakteristik 5) Seite 21 Irel = f (ϕ); T S = 25 °C
LUW CVBP.CE
ϕ [°]
-20°
-10°
0°
10°
20°
30°
40°
50°
60°
70°
80°
90° 1.0
-30° -40°
0.8
-50° 0.6 -60° 0.4
-70°
-80°
0.2
-90°
0.0
-100°
2012-12-13
8
Irel
Version 1.2
LUW CVBP.CE
Forward Current 5) page 21 Durchlassstrom 5) Seite 21
Relative Luminous Flux 5) page 21 , 6) page 21 Relativer Lichtstrom 5) Seite 21 , 6) Seite 21
IF = f (VF); TS = 25 °C IF [mA]
ΦV/ΦV(350 mA) = f(IF); TS = 25 °C
ΦV
LUW CVBP.CE
1000
ΦV(350 mA )
LUW CVBP.CE
2.5
2.0 800
1.5 600
1.0 400
0.5 200
3,4
3,6
3,8
IF [mA]
VF [V]
Chromaticity Coordinate Shift Farbortverschiebung 5) Seite 21
5) page 21
Cx, Cy = f(IF); TS = 25 °C
LUWCVBP.CE
ΔCx 0.03 ΔCy
: ΔCx : ΔCy
0.02
0.01
0.00
-0.01
-0.02
10 00
80 0
60 0
40 0
20 0
-0.03
IF [mA]
2012-12-13
10 00
3,2
80 0
3,0
60 0
2,8
40 0
2,6
20 0
0.0 2,4
9
Version 1.2
LUW CVBP.CE
Relative Forward Voltage 5) page 21 Relative Vorwärtsspannung 5) Seite 21
Relative Luminous Flux 5) page 21 Relative Lichtstrom 5) Seite 21
ΔVF = VF - VF(25°C) = f(Tj); IF = 350 mA ΔVF [V]
ΦV/ΦV(25 °C) = f(Tj); I F = 350 mA
Φv
LUW CVBP.CE
0,20
Φv(25 °C)
0,15
1.2
LUW CVBP.CE
1.0
0,10
0.8 0,05
0.6
0,00
-0,05
0.4 -0,10
0.2
-0,15
-0,20 -40 -20
0
20
40
60
0.0 -40 -20 0 20 40 60 80 100 120
80 100 120
Tj [°C]
Chromaticity Coordinate Shift Farbortverschiebung 5) Seite 21
Tj [°C]
5) page 21
Cx, Cy = f(Tj); IF = 350 mA
ΔCx 0.03 ΔCy
LUWCVBP.CE
: Δ Cx : Δ Cy
0.02
0.01
0.00
-0.01
-0.02
-0.03 -40 -20 0 20 40 60 80 100 120
Tj [°C]
2012-12-13
10
Version 1.2
LUW CVBP.CE
Max. Permissible Forward Current Max. zulässiger Durchlassstrom IF = f (T)
IF [mA]
LUW CVBP.CE
1100 1000 900 800 700 600 : TS
500 400 300 200 100
Do not use below 100 mA 0
0
20
40
60
80
100
120
140
TS [°C]
Permissible Pulse Handling Capability Zulässige Impulsbelastbarkeit IF = f(tp)
Permissible Pulse Handling Capability Zulässige Impulsbelastbarkeit IF = f(tp)
D: Duty cycle, TS = 25 °C TS = 0°C ... 74°C
IF [A]
D: Duty cycle, TS = 85 °C TS = 85°C
LUW CVBP.CE
2,2
IF [A] : D = 1.0 : D = 0.5 : D = 0.2 : D = 0.1 : D = 0.05 : D = 0.02 : D = 0.01 : D = 0.005
2,0
1,8
LUW CVBP.CE
2,2
: D = 1.0 : D = 0.5 : D = 0.2 : D = 0.1 : D = 0.05 : D = 0.02 : D = 0.01 : D = 0.005
2,0
1,8
1,6 1,6 1,4 1,4 1,2 1,2 1,0 1,0 10-6
10 -5
10-4
10 -3
0,01
0,1
1
0,8 10-6
10
Pulse time [s]
2012-12-13
10 -5
10-4
10 -3
0,01
0,1
1
10
Pulse time [s]
11
Version 1.2
LUW CVBP.CE
Package Outline 7) page 21 Maßzeichnung 7) Seite 21
Approximate Weight:
25 mg
Gewicht:
25 mg
Mark:
Anode
Markierung:
Anode
ESD information:
LED is protected by ESD device which is connected in parallel to LED-Chip.
ESD Information:
Die LED enthält ein ESD-Bauteil, das parallel zum Chip geschalten ist.
Corrosion robustness:
Test conditions: 40 °C / 90 % rh / 15 ppm H2S / 336 h = Stricter than IEC 60068-2-43 (H2S) [25°C / 75 % rh / 10 ppm H2S / 21 days] = Regarding relevant gas (H2S) stricter than EN 60068-2-60 (method 4) [25 °C / 75 % rh / 200 ppb SO2, 200 ppb NO2,10 ppb Cl2 / 21 days]
2012-12-13
12
Version 1.2
LUW CVBP.CE
Korrosionsfestigkeit:
Test Kondition: 40°C / 90 % rh / 15 ppm H2S / 336 h = Besser als IEC 60068-2-43 (H2S) [25°C / 75 % rh / 10 ppm H2S / 21 Tage] = Bezogen auf das Gas (H2S) besser als EN 60068-2-60 (method 4) [25°C / 75 % rh / 200ppb SO2, 200ppb NO2,10ppb Cl2 / 21 Tage]
Recommended Solder Pad 7) page 21 Empfohlenes Lötpaddesign 7) Seite 21
Reflow soldering Reflow-Löten
Notes:
For superior solder joint connectivity results we recommend soldering under standard nitrogen atmosphere. For further information please refer to our Application Note “Handling and Processing Details for Ceramic LEDs“. Package not suitable for ultra sonic cleaning.
Anmerkungen:
Um eine verbesserte Lötstellenkontaktierung zu erreichen, empfehlen wir, unter StandardStickstoffatmosphäre zu löten. Weitere Informationen finden Sie in der Applikationsschrift „Handling and Processing Details for Ceramic LEDs“. Das Gehäuse ist für Ultraschallreinigung nicht geeignet.
2012-12-13
13
Version 1.2
LUW CVBP.CE
Reflow Soldering Profile Reflow-Lötprofil
Preconditioning: JEDEC Level 2 acc. to J-STD-020D.01 OHA04525
300 ˚C
T 250
Tp 245 ˚C
240 ˚C
tP
217 ˚C 200
tL
150
tS
100
50 25 ˚C 0
0
50
100
150
200
s 300
250
t
OHA04612
Profile Feature Profil-Charakteristik
Symbol Symbol
Pb-Free (SnAgCu) Assembly Minimum
Ramp-up rate to preheat*) 25 °C to 150 °C Time tS TSmin to TSmax
tS
60
Ramp-up rate to peak*) TSmax to TP
Recommendation
Maximum
2
3
100
120
2
3
Unit Einheit K/s s K/s
Liquidus temperature
TL
217
Time above liquidus temperature
tL
80
100
s
Peak temperature
TP
245
260
°C
Time within 5 °C of the specified peak temperature TP - 5 K
tP
20
30
s
3
6
K/s
10
Ramp-down rate* TP to 100 °C
480
Time 25 °C to TP All temperatures refer to the center of the package, measured on the top of the component * slope calculation DT/Dt: Dt max. 5 s; fulfillment for the whole T-range
2012-12-13
°C
14
s
Version 1.2
LUW CVBP.CE
Method of Taping 7) page 21 Gurtung 7) Seite 21
2012-12-13
15
Version 1.2
LUW CVBP.CE
Tape and Reel Gurtverpackung 12 mm tape with 600 pcs. on ∅ 180 mm reel W1 D0
P0
A N
F W
E
13.0 ±0.25
P2
Label
P1 Direction of unreeling
Direction of unreeling W2
Gurtvorlauf: 400 mm Leader: 400 mm Gurtende: Trailer:
900 mm 900 mm
OHAY0324b
Tape dimensions in mm (inch) Tape dim ensions in m m ( inch)
W
P0
P1
P2
D0
E
F
12 +0.3/-0.1
4 ± 0.1 (0.157 ± 0.004)
4 ± 0.1 (0.157 ± 0.004) or 8 ± 0.1 (0.315 ± 0.004)
2 ± 0.05 (0.079 ± 0.002)
1.5 ± 0.1 (0.059 + 0.004)
1.75 ± 0.1 (0.069 ± 0.004)
5.5 ± 0.05 (0.217 ± 0.002)
Reel dimensions in mm (inch) Reel dim ensions in m m ( inch)
A
W
Nmin
W1
W2max
180 (7)
12 (0.472)
60 (2.362)
12.4 + 2 (0.488 + 0.079)
18.4 (0.724)
2012-12-13
16
Version 1.2
LUW CVBP.CE
Barcode-Product-Label (BPL) Barcode-Produkt-Etikett (BPL) OSRAM Opto
BIN1: XX-XX-X-XXX-X
LX XXXX
Semiconductors
RoHS Compliant
(6P) BATCH NO: 1234567890
ML Temp ST 2 260 °C R (1T) LOT NO: 1234567890
(9D) D/C: 1234 Pack: R18 DEMY
022
B_R999_1880.1642 R (X) PROD NO: 123456789(Q)QTY:
9999
(G) GROUP:
XX-XX-X-X
OHA04563
Dry Packing Process and Materials Trockenverpackung und Materialien Moisture-sensitive label or print L VE LE
see labe
).
(RH
idity
˚C
<
40
. RH
hum 0% e tive ˚C/6 red kag rela 30 _ pac < infra of 90% to ak < ns ed (pe or ditio and ject ˚C, sing 5 con ±
N s IVE S Otain TOR SIT UC TI SEN ND U Econ As bag UR ICO CThiIST SEM
1.
sub ces be pro
ory
Barcode label
l k,
code blan If bar
˚C
e). cod date r
rs rs rs Hou rs Hou 72 Hou 48 Hou 24 6
time time
r time 23 will at l with fact r ent˚C). MO Floo . time TO at at r Floo l ths that tica d ival ure OP Floo 4 if: rea w Floo labe mon iden 5 ced equ el ices g, n e 5a is el belo or 24 pro Lev 6 dev : ntin el whe cod e , w, e Lev el see e bag Lev l date mou bak ned stur e Lev reflo bar re> 10% led stur e time sea for ope e Moi r see stur k, is . Moi sea is has k, stur befo d 033 Moi in Floo RH blan Moi or-p blan in bag Car ing, r TD(if life r . If with r lf 10%bak J-S thisvapp. Yea _ eks rs < r w, met cato 1 Yea tem d, She nted at uire not > y 1 WeHou DEC Afte Indi 4 uire reflo is bod Mou red req /JE time 168 req : 2b r a) Sto ices idity time is IPC r or time b) ned Floo r Hum ing ce time Dev 2a r Floo a) ope 3. b) bakren Floo 1 l date Floo If 2 refe time el 4. 2a el sea Lev 3 el and e Lev el Bag e e Lev stur e Lev Dat stur e Moi stur Moi stur Moi Moi
O S R A M
2.
Humidity indicator Barcode label Please check the HIC immidiately after bag opening. Discard if circles overrun. Avoid metal contact. Do not eat. Comparator check dot
WET
If wet, examine units, if necessary bake units
15%
If wet, examine units, if necessary bake units
10% 5%
If wet, parts still adequately dry. change desiccant Humidity Indicator MIL-I-8835
AM OSR
Desiccant
OHA00539
Note:
Moisture-sensitive product is packed in a dry bag containing desiccant and a humidity card. Regarding dry pack you will find further information in the internet and in the Short Form Catalog in chapter “Tape and Reel” under the topic “Dry Pack”. Here you will also find the normative references like JEDEC.
Anm.:
Feuchteempfindliche Produkte sind verpackt in einem Trockenbeutel zusammen mit einem Trockenmittel und einer Feuchteindikatorkarte. Bezüglich Trockenverpackung finden Sie weitere Hinweise im Internet und in unserem Short Form Catalog im Kapitel “Gurtung und Verpackung” unter dem Punkt “Trockenverpackung”. Hier sind Normenbezüge, unter anderem ein Auszug der JEDEC-Norm, enthalten.
2012-12-13
17
Version 1.2
LUW CVBP.CE
Transportation Packing and Materials Kartonverpackung und Materialien
8 Q-
1
R1
lti LS TO Y T6 PL 76
1+
Mu
P-
44
(9D )
4
20
23 3G
(6P )
LO T
00
D/C : 01
998
NO : 12
O
021
H1
210
BA TC H
Se SR mi AM co nd O uc pt to o rs NO
:
).
5 14 2 110 0
(Q) QT Y:
see labe
N
(1T )
O
NO :
TI
PR OD
U
(X)
A
(G)
l k,
C
GR OU P:
Muster
L VE LE
code (RH blan If y bar . idit RH hum e 60% tive d ˚C/ kag rela are 30 E S s _ infr pac < OR of 90% to ak tainITIV urs CT < or e). ted (pe urs ons Ho con NS g urs SE DU Ho and jec ˚C, diti cod 72 sin Ho urs 5 e bag E ON 48 ˚C sub e Ho con ± ces is UR 24 6 dat e MIC 40 be tim ˚C h e ThISTSE pro < tory tim . or t wit 23 tim e at t will or fac . MO Flo al len ˚C) s tim TO at or at Flo d or ure iva el nth s tha OP ntic Flo 4 if: rea , Flo lab ow mo ice equ ced ide 5 el e 5a is ingen el or bel 24 pro 6 Lev e dev, : el e cod , unt wh Lev el re ow see bag Lev l dat mo re bak e bar ned Lev refl istu 10% re tim for sea istu ore> re Mo see 3 istu is or . sea is Mo bef nk, istu pha nk, Flo , rd -03 Mo in RH bla Mo orbag ingCa bla hin TD life (if ar If wit t. vapp. 10%baktor J-S this elf Ye ar eks , _ < ed ica med, C 1 urs Ye erow tem Sh at uire not > y 1 WeHo DE unt Aft Ind 1. e 4 uire refl red req 2. bod Mo e ity is /JE tim 168 req : e 2b a) Sto es tim or mid is IPC or tim e vic ned b) or Hu Flo tim ing ce or e De 2a Flo a) ope or 3. b) bakren Flo e 1 l dat Flo If 2 el refe tim 2a 4. el sea 3 Lev g el and Lev el re Ba te Lev re Lev istu Da re istu re Mo istu Mo istu Mo Mo
DE
8 Q-
1
R1
lti LS TO Y T6 PL 76
1+ PP: OU GR
(G)
: 01
O SR AM
rs
D/C
to
)
uc
(9D
00
nd
21 00 21 99 8 :
4
20
NO
23
QT
(Q)
O SR m A ico M
H
H1
TC BA
3G
)
: 12
(6P
(X)
PR
OD
NO
:
(1T
)
11 00
LO
T
14 2
NO
5
Se
Y:
O pt o
44
Mu
MY
ED Bin Bin 1: Bin 2: P-1 3: Q-1 -20 ML -20 2 Te 2a 220 mp 3 240 ST Ad 260 C R C R0 diti R ona C RT PA 77 l TE CK VA XT R:
ope se
Muster
led
DE MY
Barcode label
ED Bin Bin 1: Bin 2: P-1 3: Q-1 -20 ML -20 2 Tem 2a 220 3 240 p ST Ad 260 C R C R0 diti R ona C RT PA 77 l TE CK VA XT R:
Barcode label
Packing Sealing label Dimensions of transportation box in mm (inch) Width / Breite
Length / Länge
Height / Höhe
195 ± 5 (7.677 ± 0.1968)
195 ± 5 (7.677 ± 0.1968)
30 ± 5 (1.181 ± 0.196)
2012-12-13
18
OHA02044
Version 1.2
LUW CVBP.CE
Notes
Hinweise
The evaluation of eye safety occurs according to the standard IEC 62471:2008 ("photobiological safety of lamps and lamp systems"). Within the risk grouping system of this CIE standard, the LED specified in this data sheet fall into the class Moderate risk (exposure time 0.25 s). Under real circumstances (for exposure time, eye pupils, observation distance), it is assumed that no endangerment to the eye exists from these devices. As a matter of principle, however, it should be mentioned that intense light sources have a high secondary exposure potential due to their blinding effect. As is also true when viewing other bright light sources (e.g. headlights), temporary reduction in visual acuity and afterimages can occur, leading to irritation, annoyance, visual impairment, and even accidents, depending on the situation.
Die Bewertung der Augensicherheit erfolgt nach dem Standard IEC 62471:2008 ("photobiological safety of lamps and lamp systems"). Im Risikogruppensystem dieser CIE- Norm erfüllen die in diesem Datenblatt angegebenen LEDs folgende Gruppenanforderung - Moderate risk (Expositionsdauer 0,25 s). Unter realen Umständen (für Expositionsdauer, Augenpupille, Betrachtungsabstand) geht damit von diesen Bauelementen keinerlei Augengefährdung aus. Grundsätzlich sollte jedoch erwähnt werden, dass intensive Lichtquellen durch ihre Blendwirkung ein hohes sekundäres Gefahrenpotenzial besitzen. Nach einem Blick in eine helle Lichtquelle (z.B. Autoscheinwerfer), kann ein temporär eingeschränktes Sehvermögen oder auch Nachbilder zu Irritationen, Belästigungen, Beeinträchtigungen oder sogar Unfällen führen.
Subcomponents of this LED are goldplated. In spite of the improved corrosion stability of this subcomponents, it can be affected by environments that contain very high concentrations of aggressive substances. Therefore, we recommend avoiding aggressive atmospheres during storage, production and use.
Einzelkomponenten dieser LED sind goldbeschichtet. Trotz der dadurch vorhandenen verbesserten Korrosionsstabilität können Einzelkomponenten durch sehr hohe Konzentration aggressiver Substanzen angegriffen werden. Aus diesem Grund wird empfohlen aggressive Umgebungen während der Lagerung, Produktion und im Betrieb zu vermeiden.
2012-12-13
19
Version 1.2
LUW CVBP.CE
Disclaimer
Disclaimer
Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. If printed or downloaded, please find the latest version in the Internet. Packing Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components* may only be used in life-support devices** or systems with the express written approval of OSRAM OS.
Bitte beachten! Lieferbedingungen und Änderungen im Design vorbehalten. Aufgrund technischer Anforderungen können die Bauteile Gefahrstoffe enthalten. Für weitere Informationen zu gewünschten Bauteilen, wenden Sie sich bitte an unseren Vertrieb. Falls Sie dieses Datenblatt ausgedruckt oder heruntergeladen haben, finden Sie die aktuellste Version im Internet. Verpackung Benutzen Sie bitte die Ihnen bekannten Recyclingwege. Wenn diese nicht bekannt sein sollten, wenden Sie sich bitte an das nächstgelegene Vertriebsbüro. Wir nehmen das Verpackungsmaterial zurück, falls dies vereinbart wurde und das Material sortiert ist. Sie tragen die Transportkosten. Für Verpackungsmaterial, das unsortiert an uns zurückgeschickt wird oder das wir nicht annehmen müssen, stellen wir Ihnen die anfallenden Kosten in Rechnung. Bauteile, die in lebenserhaltenden Apparaten und Systemen eingesetzt werden, müssen für diese Zwecke ausdrücklich zugelassen sein! Kritische Bauteile* dürfen in lebenserhaltenden Apparaten und Systemen** nur dann eingesetzt werden, wenn ein schriftliches Einverständnis von OSRAM OS vorliegt.
*) A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or system. **) Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health and the life of the user may be endangered.
*) Ein kritisches Bauteil ist ein Bauteil, das in lebenserhaltenden Apparaten oder Systemen eingesetzt wird und dessen Defekt voraussichtlich zu einer Fehlfunktion dieses lebenserhaltenden Apparates oder Systems führen wird oder die Sicherheit oder Effektivität dieses Apparates oder Systems beeinträchtigt. **) Lebenserhaltende Apparate oder Systeme sind für (a) die Implantierung in den menschlichen Körper oder (b) für die Lebenserhaltung bestimmt. Falls Sie versagen, kann davon ausgegangen werden, dass die Gesundheit und das Leben des Patienten in Gefahr ist.
2012-12-13
20
Version 1.2
LUW CVBP.CE
Glossary
Glossar
1)
Brightness: Brightness values are measured during a current pulse of typically 25 ms, with an internal reproducibility of +/- 8 % and an expanded uncertainty of +/- 11 % (acc. to GUM with a coverage factor of k = 3).
1)
Helligkeit: Helligkeitswerte werden während eines Strompulses einer typischen Dauer von 25 ms, mit einer internen Reproduzierbarkeit von +/- 8 % und einer erweiterten Messunsicherheit von +/- 11 % gemessen (gemäß GUM mit Erweiterungsfaktor k = 3).
2)
Chromaticity coordinate groups: Chromaticity coordinates are measured during a current pulse of typically 25 ms, with an internal reproducibility of +/0,005 and an expanded uncertainty of +/- 0,01 (acc. to GUM with a coverage factor of k = 3).
2)
Farbortgruppen: Farbkoordinaten werden während eines Strompulses einer typischen Dauer von 25 ms, mit einer internen Reproduzierbarkeit von +/- 0,005 und einer erweiterten Messunsicherheit von +/- 0,01 gemessen (gemäß GUM mit Erweiterungsfaktor k = 3).
3)
Forward Voltage: The forward voltage is measured during a current pulse of typically 8 ms, with an internal reproducibility of +/- 0,05 V and an expanded uncertainty of +/- 0,1 V (acc. to GUM with a coverage factor of k=3).
3)
Durchlassspannung: Vorwärtsspannungen werden während eines Strompulses einer typischen Dauer von 8 ms, mit einer internen Reproduzierbarkeit von +/- 0,05 V und einer erweiterten Messunsicherheit von +/- 0,1 V gemessen (gemäß GUM mit Erweiterungsfaktor k=3).
4)
Thermal Resistance: Rth max is based on statistic values (6σ)
4)
Wärmewiderstand: Rth statistischen Werten (6σ)
5)
Typical Values: Due to the special conditions of the manufacturing processes of LED, the typical data or calculated correlations of technical parameters can only reflect statistical figures. These do not necessarily correspond to the actual parameters of each single product, which could differ from the typical data and calculated correlations or the typical characteristic line. If requested, e.g. because of technical improvements, these typ. data will be changed without any further notice.
5)
Typische Werte: Wegen der besonderen Prozessbedingungen bei der Herstellung von LED können typische oder abgeleitete technische Parameter nur aufgrund statistischer Werte wiedergegeben werden. Diese stimmen nicht notwendigerweise mit den Werten jedes einzelnen Produktes überein, dessen Werte sich von typischen und abgeleiteten Werten oder typischen Kennlinien unterscheiden können. Falls erforderlich, z.B. aufgrund technischer Verbesserungen, werden diese typischen Werte ohne weitere Ankündigung geändert.
6)
Relative Brightness Curve: In the range where the line of the graph is broken, you must expect higher brightness differences between single LEDs within one packing unit.
6)
Relative Helligkeitskurve: Im gestrichelten Bereich der Kennlinien muss mit erhöhten Helligkeitsunterschieden zwischen Leuchtdioden innerhalb einer Verpackungseinheit gerechnet werden.
7)
Tolerance of Measure: Dimensions are specified as follows: mm (inch).
7)
Maßtoleranz: Maße angegeben: mm (inch).
2012-12-13
21
max
werden
basiert
wie
auf
folgt
Version 1.2
LUW CVBP.CE
Published by OSRAM Opto Semiconductors GmbH Leibnizstraße 4, D-93055 Regensburg www.osram-os.com © All Rights Reserved.
2012-12-13
22