Maximal33RD Rack Mount Access Power Controller Rev. DSMaximal33RD - 11012012
Overview Maximal33RD rack mount access power controller distributes and switches power to access control systems and accessories. It converts a 115VAC 50/60Hz input into sixteen (16) independently controlled 12VDC and/or 24VDC PTC protected outputs. Outputs are activated by an normally open (NO) or normally closed (NC) dry trigger input from an Access Control System, Card Reader, Maximal33RD Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the outputs.
Input:
Specifications Visual Indicators:
• 115VAC60Hz.,3.8amp. • Normallyclosed[NC]ornormallyopen[NO] dry contact inputs (switch selectable).
• IndividualOutputStatusLEDslocatedonthe front panel.
Outputs:
• Built-inchargerforsealedleadacidorgeltype batteries (if batteries are required install separate enclosure). • Maximumchargecurrent0.7amp. • Automaticswitchovertostand-bybattery when AC fails. • Zerovoltagedropwhenunitswitchesovertobattery backup (AC failure condition).
• 12VDCor24VDC@12amptotaloutputcurrent. Powersupply1/(8)outputs: 12VDC@6ampor24VDC@6amp Powersupply2/(8)outputs: 12VDC@6ampor24VDC@6amp • Sixteen(16)PTCprotectedoutputs. • MaximumcurrentperACM8R-Moutputis2amp. • IndividuallyselectableMagLock/Strike(Fail-Safe, Fail-Secure) solid state fuse protected outputs. • Thermalandshortcircuitprotectionwithautoreset.
Fire Alarm Interface: • LatchingorNon-Latchingfirealarmresetswitch individually selectable for each output. • RemoteresetcapabilityforlatchingFireAlarm Interface mode. • FireAlarmdisconnectinputoptions: a)Normallyopen[NO]ornormallyclosed[NC] dry contact input. b)Polarity reversal input from FACP signaling circuit.
Battery Backup:
Supervision: • ACfailsupervision(form“C”contact). • Lowbatteryandbatterypresencesupervision (form“C”contact).
Additional Features: • Removableterminalblockswithlockingscrewflange. • 3-wirelinecord. • Illuminatedmasterpowerdisconnectcircuitbreaker with manual reset.
Mechanical: • Dimensions(HxWxD)(approx.):3.25”(82.55mm)x 19.125”(485.78mm)x8.5”(215.9mm) • Shipping Weight (approximate): 14.3 lbs (6.49kg).
Maximal33RD Rack Chassis Dimensions 3.25”(82.55mm)Hx19.125”(485.78mm)Wx8.5”(215.9mm)D REAR
TOP & BOTTOM 17.625" 447.67mm
8.5" 215.9mm
FRONT
19.125" 485.76mm .75" 19.05mm
AltronixCorp.-14058thStreet,Brooklyn,NY11220•718-567-8181•888-258-7669•altronix.com
IN1
IN3
IN2 GND
IN5
IN4
GND
GND
1
IN7
2
IN6
FACP
OUT9 --- +
IN8 GND
OUT12 OUT11 OUT10 --- + --- + --- +
GND
OUT16 OUT15 OUT14 OUT13 --- + --- + --- + --- +
RESET
IN9
IN11
IN10 GND
IN13
IN12
GND
GND
IN15
1
IN14
FACP 2
IN16 GND
GND
RESET
3.125" 79.375mm OUT8 --- +
OUT7 OUT6 --- + --- +
OUT5 --- +
OUT4 --- +
OUT3 OUT2 --- + --- +
OUT1 --- +