Preview only show first 10 pages with watermark. For full document please download

Download Datasheet For Pst-600-24 By Samlex America

   EMBED


Share

Transcript

600W DC-AC Inverter Pure Sine Wave Model PST-600-12 12 VDC- 120 VAC PST-600-24 24 VDC- 120 VAC Design Features - - 2 YEAR WARRANTY MODEl NO. OUTPUT INPUT DISPlAY PROTECTIONS REMOTE COOlING COMPlIANCE ENVIRONMENT DIMENSIONS WEIGHT OUTPUT VOLTAGE MAXIMUM OUTPUT CURRENT OUTPUT FREQUENCY TYPE OF OUTPUT WAVEFORM TOTAL HARMONIC DISTORTION OF OUTPUT WAVEFORM CONTINUOUS OUTPUT POWER (At Power Factor = 1) SURGE OUTPUT POWER (At Power Factor = 1; < 2 secs) PEAK EFFICIENCY AC OUTPUT CONNECTIONS NOMINAL DC INPUT VOLTAGE DC INPUT VOLTAGE RANGE MAXIMUM INPUT CURRENT DC INPUT CURRENT AT NO LOAD DC INPUT CONNECTIONS LED LOW DC INPUT VOLTAGE ALARM LOW DC INPUT VOLTAGE SHUTDOWN HIGH DC INPUT VOLTAGE SHUTDOWN SHORT CIRCUIT SHUTDOWN OVERLOAD SHUTDOWN GROUND FAULT SHUTDOWN OVER TEMPERATURE SHUTDOWN REVERSE POLARITY ON DC INPUT SIDE WIRED REMOTE CONTROL (OPTIONAL) FORCED AIR COOLING SAFETY EMI / EMC OPERATING TEMPERATURE RANGE (L X W X H), MM (L X W X H), INCHES KG LBS NOTE: Speciications are subject to change without notice PST-600-12 High eficiency Temperature controlled cooling fan – reduces energy consumption Low interference Wide operating DC input range: 10.7 - 16.5 VDC / 21.4 - 33.0 VDC Commercial grade design suitable for heavy duty loads, long periods of continuous operation & for emergency back up UPC – Universal Protection Circuit: low voltage, over voltage, over temperature, over load and short circuit. Low idle power draw Dual GFCI protected AC outlets Optional remote control (sold separately): Model RC-15A Comes with pin-type battery cable lugs Safety certiied to UL standards, FCC compliant PST-600-24 120 VAC ± 3% 120 VAC ± 3% 5.1A 5.1A 60 Hz ± 1% 60 Hz ± 1% Pure Sine Wave Pure Sine Wave < 3% < 3% 600 Watts 600 Watts 1000 Watts 1000 Watts 85% 85% NEMA5-20R GFCI Duplex Outlets NEMA5-20R GFCI Duplex Outlets 12V 24V 10.7 - 16.5 VDC 21.4 - 33 VDC 80A 40A < 600 mA < 450 mA Tubular Type Screw Down Terminals Tubular Type Screw Down Terminals Power, Overload, Over Temperature Power, Overload, Over Temperature 10.7V 21.4V 10V 20V 16.5V 33V Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes RC-15A (sold separately) Temperature Controlled Fan Temperature Controlled Fan Intertek - ETL Listed. Conforms to ANSI/UL Standard 458. FCC Part 15(B), Class B 0˚C to 40˚C / 32˚F to 107˚F 0˚C to 40˚C / 32˚F to 107˚F 276.2 x 240.6 x 82 276.2 x 240.6 x 82 10.87 x 9.47 x 3.23 10.87 x 9.47 x 3.23 2.7 2.7 5.9 5.9 12001-PST-600-12-24-0613 To view a full selection of Samlex products visit our website at www.samlexamerica.com or contact us: 1(800) 561-5885 or [email protected]