Transcript
Data Sheet No. PD 10055 revG
Series PVR13NPbF Microelectronic Power IC HEXFET® Power MOSFET Photovoltaic Relay Dual-Pole, Normally-Open 0-100V AC/DC, 360mA
General Description The PVR13 Series AC/DC Relay is a dual-pole, normally open, solid-state replacement for electromechanical relays used for general purpose switching of analog signals. It utilizes International Rectiier s HEXFET power MOSFETs as the output switches, driven by an integrated circuit photovoltaic generator of novel construction. The output switch is controlled by radiation from a GaAlAs light emitting diode (LED), which is optically isolated from the photovoltaic generator. The PVR13 Series overcomes the limitations of both conventional electromechanical and reed relays by offering the solid state advantages of long life, fast operating speed, low pick up power, bounce-free operation, low thermal offset voltages and miniature package. These advantages allow product improvement and design innovations in many applications such as process control, multiplexing, automatic test equipment and data acquisition. The PVR13 can switch analog signals from thermocouple level to 100 Volts peak AC or DC polarity. Signal frequencies into the RF range are easily controlled and switching rates up to 450Hz are achievable. The extremely small thermally generated offset voltages allow increased measurement accuracies. These relays are packaged in 16-pin, molded DIP packages and available with thru-hole leads, in plastic shipping tubes.
Bounce-Free Operation 1010 Off-State Resistance 1,000 V/µsec dv/dt 0.2 µV Thermal Offset 5 mA Input Sensitivity 1,500 VRMS I/O Isolation Solid-State Reliability
Part Identiication
Applications
Features
Process Control Data Acquisition Test Equipment Multiplexing and Scanning
PVR1300NPbF PVR1301NPbF
(HEXFET is the registered trademark for International Rectiier Power MOSFETs)
www.irf.com
1
Series PVR13NPbF
Electrical Speciications (-40°C ≤ TA ≤ +85°C unless otherwise speciied) INPUT CHARACTERISTICS
Units
Minimum Control Current A Connection (see igure 1) For 400 Continuous Load Current For 360 Continuous Load Current For 250 Continuous Load Current Minimum Turn-Off Current Minimum Turn-Off Voltage Control Current Range (Caution: current limit input LED. See igure 6) Maximum Reverse Voltage
2.0 5.0 5.0 10
DC mA@25°C mA@40°C mA@85°C µA(DC)
0.6 2.0 to 25
V(DC) mA(DC)
6.0
V(DC)
±100
V(peak)
`OUTPUT CHARACTERISTICS
Units
Operating Voltage Range Maxiumum Load Current 40°C ILED = 5mA (see igure 1) AC (A Connection) DC (B Connection) DC (C Connection) Response Time @25°C (see igures 7 and 8) Maximum T(on) @ 12mA Control, 100 mA Load, 100 VDC Maximum T(off) @ 12mA Control, 100 mA Load, 100 VDC Maximum On-state Resistance 25°C (Pulsed) (ig. 2) 50 mA Load, 5mA Control AC (A Connection) DC (B Connection) DC (C Connection) Minimum Off-state Resistance 25°C
@ 80 VDC PVR1300 @ 80 VDC PVR1301
Maximum Thermal Offset Voltage @ 5.0mA Control
360 420 660
mA (peak) mA(DC) mA(DC)
150 125
µs µs
5 3.0 1.5
Ω Ω Ω
108 1010
Ω Ω
0.2
µvolts
1000 12
V/µs pF @ 50VDC
Dielectric Strength: Input-Output
1500
VRMS
Insulation Resistance: Input-Output @ 500VDC
1012
Ω
Maximum Capacitance: Input-Output
1.0
pF
Minimum Off-State dv/dt Typical Output Capacitance (see igure 9)
GENERAL CHARACTERISTICS
Units
Maximum Lead Soldering Temperature (1.6mm below seating plane for 10 sec.) Ambient Temperature Range:
260
°C
Operating
-40 to +85
°C
Storage
-40 to +100
International Rectiier does not recommend the use of this product in aerospace, avionics, military or life support applications. Users of this International Rectiier product in such applications assume all risks of such use and indemnify International Rectiier against all damages resulting from such use.
www.irf.com
2
Series PVR13NPbF
Max. Load Current (mA)
800
55 mA Control Control llD mA D = 50 mA
Rd(on) (Normalized to 25oC)
900
C Connection
700 600 500 B Connection 400
A Connection 300 200 100
ILED = 5mA
0 0
20
40
60
80
100
Ambient Temperature (°C)
Ambient Temperature (°C)
Figure 1. Current Derating Curve
Figure 2. Typical Normalized On-Resistance
600 500 450 400 350 300 250 200 150 100 50 0
25 oC 40 oC 60 oC
Pulsed, 25ºC
85 oC
I LED = 5mA, Forced Air
A Connection 0.0
0.5
1.0
1.5
2.0
2.5
Load Current (mA)
Load Current (mA)
550
1.3 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0
25 oC 40 oC 60 oC
Pulsed, 25ºC
o 85ºC 85 C
I LED = 5mA, Forced Air
C Connection 0.0
0.5
1.0
1.5
2.0
2.5
VDD (Volts)
VDD (Volts)
Figure 3. Typical On-Characteristic A Connection
Figure 4. Typical On-Characteristic C Connection
www.irf.com
3
Series PVR13NPbF
8 4 00
Ambient Temperature (°C) Figure 5. Typical Normalized Off-State Leakage
0
Max M ax.. de devivice cean an o o dd- 40 - 40 CC limlim it it
12 2
TT YYPPIIC AL CA L
16 6
CAUTION: Provide limiting CAUTION: Providecurrent current so that 25mA maximum limiting so tha t 25 mAsteady-state maximum control currentcontrol is not exceeded. steady-state current is not exceeded.
Min.. devic Min e an vice d +8 and 5 oCo Climlim +85 it it
IDOff/IDOff 25°C
Input Current (mA)
20 0
0.5 1.0 1.5 LED Forward Voltage Drop (Volts DC)
2.0
Figure 6. Input Characteristics (Current Controlled)
Delay Time (µS)
1000
Ton Tdly 00
Toff
10 0
5
10
15
20
ILED (mA) Figure 7.Typical Delay Times
www.irf.com
Figure 8. Delay Time Deinitions
4
Series PVR13NPbF
Typical Capacitance (pF)
220 200 180 160 140 120 100 80 60
C Connection
40 20
A Connection
0 0
10
20
30
40
50
VDD Drain-to-Drain Voltage Figure 9. Typical Output Capacitance
Wiring Diagram
Schematic Diagram Drain (1/8) Anode (3/5)
Source (14/11)
(4/6) Cathode (16/9) Drain (Pole1/Pole 2)
www.irf.com
5
Series PVR13NPbF
Case Outline
01-2012 00
www.irf.com
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245 Tel: (310) 252-7105 Data and speciications subject to change without notice. 2/2008
6