DF-52353 • F-250 October 12, 2004 BG-12LR and BG-12LRA Dual-Action Agent Release Stations www.firelite.com Section: Releasing Panels GENERAL MEA The BG-12LR and BG-12LRA are Agent Release Stations designed for use with Fire-Lite's Fire Alarm Control Panels with releasing capabilities and RP Series Releasing Systems. FEATURES 67-20-E S692 • Non-coded, dual action operation. California State Fire Marshal 7150-0028:199 • Made with durable polycarbonate. • Optional surface backbox. • BG-12LRA includes: Abort switch. Power-on indication (system normal). Released indication (system activated). Manual release (dual-action operation). • BG-12LR includes: Dual-action release only. APPLICATIONS The BG-12LRA and BG-12LR are ideal for areas such as clean rooms and computer rooms where a chemical agent is used to extinguish a fire. BG-12LRA Agent release station with abort switch, system activated LED systems, Normal LED. BG-12LR Dual-action agent release station. SBA-10 Surface backbox for BG-12LRA. SB-I/O Indoor/Outdoor surface backbox for BG12LR (indoor applications). SB-10 Surface backbox for BG-12LR. 17003 Key. 6840RA12.wmf PRODUCT LINE INFORMATION Dual-Action BG-12LR 6840LR12.wmf NOTIFIER NOTIFIER Dual-Action BG-12LRA (shown activated) Fire•Lite® Alarms is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. DF-52353 • 10/12/04 — Page 1 of 2 DIMENSIONS, BACKBOXES WIRING both are 1.375" (3.49) deep 6840wir1.wmf *NOTE: Mount End-of-Line Resistor on the last unit. *Mount 4.7K ELR on the last unit when abort switch and manual release switch are connected to control panel circuits. Mount 47K resistor on last unit when abort switch and manual release switch are connected to an addressable monitor module or control module. Refer to control panel manual for the listed ELR. 6840sbba.wmf 12345678901234 12345678901234 12345678901234 12345678901234 Normally Open 12345678901234 12345678901234 12345678901234 Abort Switch 12345678901234 12345678901234 52353sb1.wmf 6840wir2.wmf SB-I/O BG-12LRA (rear view) Agent Release Pull Station 52353sb3.wmf Page 2 of 2 — DF-52353 • 10/12/04 52353sb2.wmf