Transcript
DT-6S 6 STAGE
BATTERY CHARGING TECHNOLOGY (Increases Battery Life Upto 30%)
YOUR POWERFUL PARTNER NOW WITH
MCB ADDED FOR SAFETY &
ZERO DOWNTIME Design Registration No. 3811 & 25374 & 12031 & 9424 & 11727 Copyright © 2010 Su-Kam Power Systems Ltd.
SHARK Shark 700, Shark 900, Shark 1600
Digital UPS DT-6S technology along with MCB provides effective de-sulphation of battery ensuring 10% faster charging and battery life increment of at least 30% over existing technology Mains line overload protection by MCB
www.su-kam.com
Does your battery give optimum back up? Does your battery have a shorter lifespan? Does your battery need frequent water topping? The ordinary inverter battery charger that most of us know use only two stages of charging which are: Bulk and Float This 2 stage inverter battery charger suffers from frequent water topping of battery leading to high maintenance cost and release of more harmful gases in environment. Moreover batteries charged from these
inverters do not give proper back up time and also shorten life of the battery leading to high cost to users. For the first time in India, Su-Kam introduces 6 stage battery charging technology based on microprocessor (using next generation computer chips) to recharge, using 6 stages regulated charging.
DT-6S 6 STAGE
BATTERY CHARGING TECHNOLOGY (Increases Battery Life Upto 30%)
FIRST STAGE
SECOND STAGE
THIRD STAGE
FOURTH STAGE
FIFTH STAGE
SIXTH STAGE
DESULPHATION
SOFT START
BULK CHARGE
ABSORPTION
EQUALISATION
FLOAT
Desulphation Charging Inverter Batteries are Lead Acid units which are composed of Lead Plates submerged in Sulphuric Acid. Over time during the operation of battery a chemical compound called lead sulphate builds up and bonds to battery plates. This causes less surface area of plates to react with acid hence less power produced by battery. Su-Kam’s DT-6S Charging technology uses high voltage, low current micropulses to detach the sulphate crystal from the plates. This enables battery to produce optimum power and prolongs battery life. Soft Start Charging A Deep discharged battery needs a reduced charging current when it is first hooked up on charging mode otherwise battery could be damaged. The soft start charging stage offers smaller charging current & start up low voltage until battery gets back up to about 10-15% before the next stage of battery charging begins. Bulk Charging After the soft start charging, battery is safe to charge with a rapid high voltage and constant predefined current until battery reaches about 80% of charge level. Su-Kam’s DT-6S technology makes this happen as quickly as possible with all safety and without harming long term life of the battery. Absorption Charging Stage Once the battery charger detects that the charging has slowed down at about 80% of charge level, it begins to
taper the charging current and feeding the battery until it reaches 100% of charge level. Equalization Charging Stage It reverses the buildup of negative chemical effects like stratification, a condition where acid concentration is greater at the bottom of the battery than at the top. Equalizing also helps to remove sulfate crystals that might have built up on the plates. If left unchecked, this condition, called sulfation, will reduce the overall capacity of the battery. Basically this stage is set to shake acid and water up. Enough current is fed to the battery to cause tiny bubbles to form stirring up the acid which was settled at the bottom of the battery and remixing the acid and water back into efficient solution hence optimum performance from the battery. Su-Kam’s DT-6S technology has the program built into the chargers to enable batteries be equalized periodically, ranging anywhere from once a month to once or twice per year. Float Maintenance Stage The FLOAT stage is where the charge voltage is reduced to a preset level and held constant, while the current is reduced to less than 1% of battery capacity. This mode is used to maintain the battery at full charge level.
Keep Your Battery Healthy
The real advantages of smart multi stage chargers are:
Optimum back up time from battery Fast and full charging, ultimately
leading to get a longer battery life
Does not require frequent water topping of battery
100% HEALTHY BATTERY
The SHARK Advantage Cut down your electricity bills Now save your electricity bills. Optimal power consumption. Highest power factor in this range.
hence reducing maintenance cost and efforts
Controls the emission of harmful gases into the environment
Overall Protection Smart Short Circuit Protection Protects the appliances in case of any short circuit. In case of short circuit the system beeps & retries 4 times. After 4 beeps, the system will shut down automatically.
Automatic low battery protection Checks batteries while in battery mode to protect the batteries from deep discharge. .
Micro-controller based operation Based on the world’s most advanced micro-controller technology which improves the efficiency of the whole system and provides clean power as well.
Reduced Water Topping DT-6S 6 Stage Charging controls the emission of gases while charging the battery, thus reducing the frequency of water topping significantly.
Compatibility with batteries The three way slider selection switch gives you option to provide charge to the battery according to the battery type thus improving back-up quality and enhancing battery life.
MCB (Miniature Circuit Breaker) Shark series is equipped with MCB (Miniature Circuit Breaker) to protect the system and appliances from various distortions present in the power supply and also provide short circuit protection.
SMF – The batteries will be charged at 14.2 V. Tubular – The batteries will be charged at 14.5 V. LA – The batteries will be charged at 13.9V.
UPS mode/Wide UPS mode – A slider selection switch can be used to select the system mode – UPS mode (for sensitive appliances) or Wide UPS mode (for non-sensitive).
Shark 1600
Smart Overload Protection Protects the system from breakdown in case of overload. The system gives a repeated beep alarm to inform the user about overload. In case the load is not reduced, the system will shut down automatically after 8 repeated beep alarms.
Shark 700
Shark 900
Shark 700
SHARK - 700/12V (Single Battery) OPTION* A
B
Computer - - Printer - - Television - - Tube Lights 3 - Fans 3 - CFL 3 29
Shark 900
C
D
C
D
C
D
- 1 - 1 1 1 2 1 6 4
SHARK 900/12V (Single Battery) OPTION* A
B
Computer - - Printer - - Television - - Tube Lights 4 - Fans 4 - CFL 3 38
- 1 - 1 1 3 1 3 1 6 6
SHARK 1600/24V (Double Battery)
Shark 1600
OPTION* A
B
Computer - - - 1 Printer - - - 1 Television - - 1 Tube Lights 8 - 6 4 Fans 8 - 6 4 CFL 5 64 10 5 Note: Indicative value only. Actual calculation depends on manufacturer’s specification.
Computer & printer - upto 150W. When PC is running, TV is not recommended with 700 & 900 models.
05/15/SHARK/B01
Applications: Computer, Television, Printer, CFL / Bulbs, Tube lights, Fans, Room Cooler, Mixer Grinder etc.
Copyright © 2015 Su-Kam all rights reserved.
* CFL-11W, Ceiling Fan - 3 blades 48MM 1000-1200 MM Sweep, TV -19-21”, Tub light - 40W
Just a phone call away (For India Only)
Service Support: 1800-102-4423 Sales Support: 1800-102-7555 Su-Kam Power Systems Limited Corporate Office: 54, Udyog Vihar, Phase VI, Sector 37, Gurgaon-122001, Haryana, India Tel: +91-124-4170500 Fax: +91-124-4038700/1/2 E-mail India:
[email protected] • E-mail Export:
[email protected] Website: www.su-kam.com • Solar Website: www.sukam-solar.com