Transcript
R
TE
YEA
AC - DC DIN rail mountable 240W power supplies
E
DPS Series 240W AC/DC DIN Rail Power Supplies GUARAN
z Compact design z High efficiency up to 89%
R
TE
z Input voltage 115/230VAC auto select
YEA
z Parallel function available (switch)
E
z PFC function available GUARAN
z 3 Year warranty
Specificaton Model Input Voltage Output Wattage Output Voltage Output Current Efficiency (min/typ) General Specification Isolation voltage Isolation resistance Ambient temperature Derating (from 61 to 71°C) Storage temperature Relative humidity Cooling Dimensions Weight Case material
DPS-1-240/07/07
DPS-1-240-24 115/230VAC 240W 24VDC 10A 87/89% 3000VAC 100MΩ @ 500VDC -10 to +71°C 2.5%/°C -25 to +85°C 20 to 95% RH Free air convection L125 x W83 x D126 mm 1000g Metal
Input Specifications Rated input voltage 115/230VAC Input voltage range 115V: 93 to 132VAC, 230V: 186 to 264VDC Rated input current 5.4/2.2A Line frequency 47 to 63Hz Inrush current 30A @ 115VAC, 60A @ 230VAC PFC 0.7 @ 230VAC Output Specifications Output voltage accuracy 0 to 1% (adjusted pre-shipment) Minimum load 0% Line regulation ±0.5% Load regulation ±1% single mode, ±5% parallel mode Hold up time 25mS @ 115VAC, 30mS @ 230VAC Temperature coefficient ±0.02%/°C Ripple & noise 100mV Voltage trim range 22.5 to 28.5VDC DC ON indicator threshold at start up 17.6 to 19.4VDC DC LO indicator threshold after start up 17.6 to 19.4VDC Parallel operation up to 3 units Control and Protection Input fuse T6.3A/250VAC internal Rated over load protection 120 to 145% Power Rdy Electrical isolation: 500VDC Threshold volt. contact closed (start up): 17.6 to 19.4VDC Contact rating: 0.3A @ 60VDC Over voltage protection 120 to 145% Output short circuit Current limited Approvals and Standards CE, UL/cUL
www.imopc.com
DPS Series 240W AC/DC DIN Rail Power Supplies L N
83
7
9
Dimensions (mm) 6 Fuse
L
S P
116
1 Inrush Current
- - ++ RdyLimiter, Rectifier Filter
and Auto Select 115/230VAC
Vout adj. DC LO DC ON
Y
PFC Circuit
Smoothing Circuit
Key Description Rdy(1,2) DC ON output for relay (24V models only) + (3) Positive output terminal Vo+ + (4) Positive output terminal - (5) Current Negative output terminal VoDetection - (6) Negative output terminal Single/Parallel (7) Ground terminal to minimize high-frequency emissions Select Reference & L (8) Input terminals (phase conductor, no polarity at DC input) Error Amp. Vout adj.no polarity at DC input) N (9) Input terminals (neutral conductor, DC ON Operation indicator LED Over Voltage DC LO Detection DC low voltage indicator LED Vout adj. Trimmer-potentiometer for Vout adjustment DC ON (Green LED) Outputselect Level switch S/P Single/Parallel Detection DC LO (Red LED)
10
Switching Device PWM Controller
125
N
Pin connections
Rectifier
OptoIsolation OptoIsolation
L N 83
7
9
6 Switching Device
Rectifier
S P
1
- - ++ Rdy Vout adj. DC LO DC ON
PWM Controller
Vo+
Current Detection
Reference & Error Amp.
OptoIsolation
Single/Parallel Select Vout adj.
L Detection N 63.2
Temperature (°C)
Screw Terminal 10-24AWG flexible/solid cable Strip cable ends by 8mm
Over Voltage
OptoIsolation
0 -10
Easy, safe and secure snap-on, snap-off DIN-Rail mounting (TS35/7.5 or TS35/15)
Vo-
123.6
Power out (%)
100 PFC Smoothing Circuit Circuit 75
Construction
Ventilation/Cooling Normal convection All sides 25mm free space 116.6 7.0 for cooling recommended
Derating
h Current r, Rectifier uto Select /230VAC
RDY (Relay Contact)*
Installation
*24V models only
761
9
71
Output Level Detection
DC ON (Green LED) DC LO (Red LED) RDY (Relay Contact)*
Connections L
Fuse
Inrush Current Limiter, Rectifier and Auto Select 115/230VAC
Filter N Y
PFC Circuit
Smoothing Circuit
Switching Device PWM Controller
Vo+ Rectifier
Current Detection
Vo-
OptoIsolation
Reference & Error Amp.
OptoIsolation
Over Voltage Detection Output Level Detection
Temperature (°C)
61
71
Single/Parallel Select Vout adj.
DC ON (Green LED) DC LO (Red LED) RDY (Relay Contact)*
*24V models only
DPS-1-240/07/07
www.imopc.com