Preview only show first 10 pages with watermark. For full document please download

Draadloze Transmitter Voor Temperatuur Thuw1103hp

   EMBED


Share

Transcript

THUW1103HP Universal Wireless Temperature Transmitter Introduction Extreme low power Long battery life Long distance range (5 Km LoS) Universal sensor input Real time transmission The Tekon Electronics In Head Wireless Universal Temperature Transmitter is specifically designed to meet the most rigorous requirements of operation in the industrial process environments. Due to its reduced dimension it may be installed in the DIN Form B sensor connection head in place of the traditional terminal block or current loop temperature transmitter. The THUW1103HP has an extreme low power operation mode that guaranties a long battery life. In its high power mode it can communicate over a long distance range (up to 5 Km Line of Sight). It accepts the most commonly used temperature sensors. The measured information (Sensor Temperature, Ambient Temperature, RF Signal Strength and Battery Status) is transmitted wireless to the receiver WGW1104HP and become available on the RS485 interface with Modbus protocol and in an analog current output. The operating parameters like the sensor probe type and transmission interval can be easily configured using the OTA - Over The Air setup and configuration function. The Battery level and RF link quality may be verified on site during the installation process. Key features  Long distance range communication (up to 5 Km LoS)  Universal sensor input: Resistance thermometers (2, 3 or 4-  Extreme low power operation mode for long battery life wire system), Thermocouples, Resistance-based sensors and  Real time transmission of sensor temperature, ambient DC voltage sources. temperature, RF signal strength and battery status  High measurement accuracy  Wide range supply voltage  Sensor status monitoring  Over The Air setup and configuration  Compact design for DIN Form B connection head mounting  On site battery and RF signal strength verification Block diagram © 2012 Bresimar Automação S.A. DSTHUW1103HPEN R01.00 1/5 Tekon Temperature Measurement Solutions THUW1103HP Universal Wireless Temperature Transmitter Technical specifications Input Resistance thermometer (RTD) Measuring accuracy Measured variable Sensor type Units Digital measuring errors Connection Sensor current Response time Open-circuit monitoring Short-circuit monitoring Measuring range Minimum measured span Characteristic curve Temperature Pt100, Pt500, Pt1000 ºC or ºF 1 Resistance thermometer (RTD) in 2-wire, 3-wire or 4wire system Resistance compensation in 2wire systems available through software <0.05 mA (50 µA) <500 ms Always active (cannot be disabled) Always active (cannot be disabled) Parameterizable (see table "Digital measuring errors") 50 ºC (90 ºF) Temperature-linear Reference conditions: Auxiliary power Ambient temperature Warming-up time Error due to internal cold junction Influence of ambient temperature with resistance thermometers with thermocouples Measured variable Sensor type Units Connection Response time Open-circuit monitoring Short-circuit monitoring Cold junction compensation (CJC) Measuring range Minimum measured span Temperature-linear 1 Thermocouple (TC) <500 ms Always active (cannot be disabled) Not available Integrated resistance thermometer Configurable (see table "Digital measuring errors") 50 ºC (90 ºF) Temperature-linear Transmission frequency Resistance thermometer (RTD) Digital accuracy ºC (ºF) Pt100 -200 to 850 (-328 to 1562) -200 to 850 (-328 to 1562) -200 to 350 (-328 to 662) 0,1 (0,18) Transmission interval Maximum output power Sensitivity Open air range Output signals Temp probe (RTD or TC) Internal Temp RSSI Power supply level Configurable parameters © 2012 Bresimar Automação S.A. 0,2 (0.40) 0,2 (0.40) Digital measuring accuracy Thermocouples (TC) Sensor Range ºC (ºF) Digital accuracy ºC (ºF) E -200 to +1000 (-328 to +1832) -210 to +1200 (-346 to +2192) -230 to +1370 (-382 to +2498) -200 to +1300 (-328 to +2372) -50 to +1760 (-58 to +3200) -50 to +1760 (-58 to +3200) -200 to +400 (-328 to +752) 1 J K N R T 868 MHz [868; 870] MHz Adjustable from 1s to 24h 27 dBm -108 dBm 3.5 Km LoS 0,06 ºC (0,11 °F) / 10 ºC (18 ºF) 0,6 ºC (1,1 ºF) / 10 ºC (18 ºF) Range ºC (ºF) S Output RF transmission < 0,5 ºC (0,9 ºF) Sensor Pt1000 Temperature E, J, K, N, R, S, T ºC or ºF 9 V DC ± 1% 23 ºC (73,4 ºF) > 5 min Digital measuring accuracy Pt500 Input Thermocouples (TC) See table "Digital measuring errors" 1 1 1 2 2 1 NOTE: The digital accuracy is the accuracy after the analog/digital conversion including linearization and calculation of the measured value. Power Supply Temperature ºC (ºF) Temperature ºC (ºF) Absolute value Voltage V Sensor type, Transmission interval Voltage Range Power Consumption (Sleep) Battery Life [5; 24] VDC < 0.2 mA For a 9V battery, with 1200 mAh with a transmission interval of 2 minutes, the battery life is higher than 2 years DSTHUW1103HPEN R01.00 2/5 THUW1103HP Universal Wireless Temperature Transmitter Tekon Temperature Measurement Solutions Ambient conditions Casing Ambient temperature range Storage temperature range Relative humidity -20 to 80 ºC (-4 a 176 ºF) -20 to 80 ºC (-4 a 176 ºF) ≤ 95 %, without condensation Certificates and approvals EN 61326 IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 Dimensional drawings © 2012 Bresimar Automação S.A. Electrical equipment for measurement, control and laboratory use. EMC requirements. Electrostatic discharge immunity test Radiated, Radio-Frequency, Electromagnetic Field Immunity Test Electrical fast transient/burst immunity test Surge Immunity Test Material Weight Dimensions Cross-section of cables Protection type Antenna connection Nylon 66 Approx. 50 g See “Dimensional drawings” 2.5 mm2 IP40 SMB connector Factory settings Sensor Measuring range Transmission interval Node ID Net ID Thermocouple K 0…100 ºC (32 … 212 ºF) 300 s 1 1 Installation diagram DSTHUW1103HPEN R01.00 3/5 Tekon Temperature Measurement Solutions THUW1103HP Universal Wireless Temperature Transmitter Electrical connections diagram Installation procedure 1. Select the Node ID and Net ID. The Net ID must have the same value configured in the receiver WGW410. The Node ID must be unique for each Net ID. 2. Connect the temperature probe according to the electrical connections diagram. 3. Connect the power supply according to the electrical connections diagram. 4. Press the test button. 5. The THUW1103HP will show the RSSI value in the status LEDs. 6. Next THUW1103HP will show the value of the selected Node ID for confirmation. 7. Next THUW1103HP will show the value of the selected Net ID for confirmation. For further info on Installation Procedure, please check “STARTER KIT QUICK INSTALLATION GUIDE.PDF” © 2012 Bresimar Automação S.A. DSTHUW1103HPEN R01.00 4/5 THUW1103HP Universal Wireless Temperature Transmitter Tekon Temperature Measurement Solutions Battery Life time The battery life time graph is a theoretical estimate. External factors as: Ambient temperatures, humidity, terrain topology, signal quality amongst others can influence the final outcome. Selection and ordering data Image Partnumber Partname PA110070100 THUW1103HP Universal Wireless Temperature Transmitter HP Related products PA110060100 © 2012 Bresimar Automação S.A. WGW1104HP Wireless Modbus Gateway HP DSTHUW1103HPEN R01.00 5/5