Dramm T42 - 2 Speed Fans With Louver Thermostat Directions 1.

   EMBED


Share

Transcript

Dramm T42 - 2 Speed Fans with Louver 1- Below 80 - Fans off 2- Above 80 Below 85 Louvers open - low fans 3- Above 85 Louvers open fan high Connect Ground to this terminal Thermostat Directions L'Voltage In 1. Always install the ground wire to the clip provided. 2. Thermostat is rain tight and drip proof, but is not a sealed unit. Do not submerge or install where unit will be under water. 3. Always install in accordance with all applicable electrical codes and requirements. 4. Do not exceed the loads listed on the thermostat. MAX MIN Control to high speed Control to low speed Min set 80 Max set 85 Control to open louvers Calibration 1. To reset thermostat calibration use an accurate thermometer to find the current temperature. 2. Line up the indicating mark on their thermostat dial with the current temperature. 3. Tightly grip the outside of the knob with one hand and rotate the star shaped part of the knob with the other hand until a click is heard. Dramm T42 - 2 Speed Fans No Louver Connect Ground to this terminal 1- Below 80 - Fans off 2- Above 80 Below 85 low speed fans 3- Above 85 high speed fans L'Voltage In MAX MIN Installation Control to high speed Control to low speed Min set 80 Max set 85 Dramm T42 - 2 Stage Heating Connect Ground to this terminal To stage 1 heaters To stage 2 heaters 1. Place thermostat in the desired location. 2. Install the wiring into the box using the water tight connector provided. 3. Connect the wiring to the terminals per the drawings included. MAX MIN L'Voltage In 8/5/99 – 1901 1- Above 68 - off 2- Above 64 Below 68 Stage 1 heaters– on 3- Below 64 Stage 1 & 2 heaters– on PO Box 1960 Manitowoc, WI 54221-1960 Min set 64 Max set 68 920.684.0227 • FAX: 920.684.4499 [email protected] 800-258-0848