Preview only show first 10 pages with watermark. For full document please download

Ds Relays Ds Features Highly Sensitive 1500 V

   EMBED


Share

Transcript

DS HIGHLY SENSITIVE 1500 V FCC SURGE WITHSTANDING MINIATURE RELAY 35.24 1.387 DS RELAYS FEATURES 9.9 .390 9.9 .390 20 .787 9.8 .386 9.8 .386 9.9 .390 15 .590 9.8 .38 DS4E DS2E mm inch DS1E • High sensitivity: 200 mW pick-up power 100 mW pick-up power types available • Latching types available • High switching capacity: 60 W, 125 V A • High breakdown voltage: 1,500 V FCC surge between open contacts 1,000 V AC between open contacts • DIP-1C type can be used with 14 pin IC socket 2C type can be used with 16 pin IC socket, 4C type can be used with 2 sets of 14 pin IC sockets • Gold-cap silver palladium types available for 2 Form C type • Bifurcated contacts are standard SPECIFICATIONS Characteristics (at 20°C 68°F) Contact Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Max. switching power Max. switching voltage Rating Max. switching current (resistive) Max. carrying current Min. switching capacity (Reference value)#1 Mechanical Expected life (at 600 cpm) (min. Electrical operations) 2 A 30 VDC resistive 1 Form C, 2 Form C, 4 Form C 50 mΩ Gold-clad silver 60 W, 125 VA 220 V DC, 250 V AC 2 A DC, AC 3 A DC, AC 10 µA, 10 mV DC 108 (1 Form C 2 coil latching type: 107) 5×105 Notes: #1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. (SX relays are available for low level load switching [10V DC, 10mA max. level]) * Gold capped silver-palladium contact also available for 2 Form C 107 operations at 0.1 A 50 V DC resistive Minimum operating power Approx. 200 mW Nominal operating power Approx. 400 mW 1 coil latching Minimum set and reset power Nominal set and reset power Minimum set and reset power Nominal set and reset power Minimum operating power Single side stable S type 1 coil latching 2 coil latching Shock resistance Functional*4 Destructive*5 Functional*6 Destructive Single side stable 2 coil latching Initial insulation resistance*1 Type of relay Initial Between open contacts breakdown Between contacts sets voltage*2 Between contacts and coil FCC surge voltage between contacts and coil Operate time*3 (at nominal voltage) Release time (without diode)*3 (at nominal voltage) Set time*3 (at nominal voltage) Reset time*3 (at nominal voltage) Temperature rise (at nominal voltage, Contact current: 2A) Vibration resistance Coil (polarized) (at 20°C 68°F) M type Max. operating speed Nominal operating power Approx. 90 mW Approx. 180 mW Approx. 180 mW Approx. 360 mW Approx. 100 mW (128 mW)* Approx. 200 mW Minimum set and reset power Nominal set and reset power Minimum set and reset power Nominal set and reset power Approx. 45 mW (58 mW)* Approx. 90 mW Approx. 90 mW (115 mW)* Approx. 180 mW * For 1 Form C high sensitive types. FCC (Federal Communication Commission) requests following standard as Breakdown Voltage specification. Conditions for operation, transport and storage*7 (Not freezing and condensing at low temperature) Unit weight Ambient temp. 20 cpm at rated load 50 cps at low level load Min. 100 MΩ (at 500 V DC) (DS1-S type) (Other types) 500 Vrms 1,000 Vrms — 1,000 Vrms 1,000 Vrms 1,500 Vrms 1,500 V (Expect DS1-S type) Max. 10 ms Max. 5 ms Max. 10 ms Max. 10 ms Max. 65°C 1C, 2C:Min. 490 m/s2 {50 G} 4C:Min. 294 m/s2 {30 G} Min. 980 m/s2 {100 G} 10 to 55 Hz at double amplitude of 3.3 mm 10 to 55 Hz at double amplitude of 5 mm –40°C to +70°C –40°F to +158°F Humidity 5 to 85% R.H. 1 Form C 2 Form C 4 Form C Approx. 3.2g .11oz Approx. 4g .14oz Approx. 7g .25oz Remarks * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as “Initial breakdown voltage” section *2 Detection current: 10 mA *3 Excluding contact bounce time *4 Half-wave pulse of sine wave: 11ms; detection time: 10μs *5 Half-wave pulse of sine wave: 6ms *6 Detection time: 10μs *7 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (p. 19, Relay Technical Information). 1500V 750V 10 μs 160 μs ds_61005_0001_en_ds: 061006J 1 DS TYPICAL APPLICATIONS ORDERING INFORMATION Ex DS • Telecommunication equipment • Office equipment • Computer peripherals • Security equipment • Measuring instrumentation Contact arrangement 1: 1 Form C 2: 2 Form C 4: 4 Form C 2 Classification of type E: Amber sealed type E M L2 Sensitivity M: 400 mW nominal operating power S: 200 mW nominal operating power DC 48 V Operating function Nil: Single side stable L: 1 coil latching L2: 2 coil latching R * Coil voltage DC 1.5, 3, 5, 6, 9, 12, 24, 48 V *Reverse polarity types available (add suffix-R). Standard packing: Carton: 50 pcs.; Case: 500 pcs. TYPES Single side stable Nominal Voltage, V DC 1.5 3 5 6 9 12 24 48 1.5 3 5 6 9 12 24 48 M (400 mW) type S (200 mW) type 1 Form C DS1E-M-DC1.5V DS1E-M-DC3V DS1E-M-DC5V DS1E-M-DC6V DS1E-M-DC9V DS1E-M-DC12V DS1E-M-DC24V DS1E-M-DC48V DS1E-S-DC1.5V DS1E-S-DC3V DS1E-S-DC5V DS1E-S-DC6V DS1E-S-DC9V DS1E-S-DC12V DS1E-S-DC24V DS1E-S-DC48V Part No. 2 Form C DS2E-M-DC1.5V DS2E-M-DC3V DS2E-M-DC5V DS2E-M-DC6V DS2E-M-DC9V DS2E-M-DC12V DS2E-M-DC24V DS2E-M-DC48V DS2E-S-DC1.5V DS2E-S-DC3V DS2E-S-DC5V DS2E-S-DC6V DS2E-S-DC9V DS2E-S-DC12V DS2E-S-DC24V DS2E-S-DC48V 4 Form C DS4E-M-DC1.5V DS4E-M-DC3V DS4E-M-DC5V DS4E-M-DC6V DS4E-M-DC9V DS4E-M-DC12V DS4E-M-DC24V DS4E-M-DC48V DS4E-S-DC1.5V DS4E-S-DC3V DS4E-S-DC5V DS4E-S-DC6V DS4E-S-DC9V DS4E-S-DC12V DS4E-S-DC24V DS4E-S-DC48V 1 Form C DS1E-ML-DC1.5V DS1E-ML-DC3V DS1E-ML-DC5V DS1E-ML-DC6V DS1E-ML-DC9V DS1E-ML-DC12V DS1E-ML-DC24V DS1E-ML-DC48V DS1E-SL-DC1.5V DS1E-SL-DC3V DS1E-SL-DC5V DS1E-SL-DC6V DS1E-SL-DC9V DS1E-SL-DC12V DS1E-SL-DC24V DS1E-SL-DC48V Part No. 2 Form C DS2E-ML-DC1.5V DS2E-ML-DC3V DS2E-ML-DC5V DS2E-ML-DC6V DS2E-ML-DC9V DS2E-ML-DC12V DS2E-ML-DC24V DS2E-ML-DC48V DS2E-SL-DC1.5V DS2E-SL-DC3V DS2E-SL-DC5V DS2E-SL-DC6V DS2E-SL-DC9V DS2E-SL-DC12V DS2E-SL-DC24V DS2E-SL-DC48V 4 Form C DS4E-ML-DC1.5V DS4E-ML-DC3V DS4E-ML-DC5V DS4E-ML-DC6V DS4E-ML-DC9V DS4E-ML-DC12V DS4E-ML-DC24V DS4E-ML-DC48V DS4E-SL-DC1.5V DS4E-SL-DC3V DS4E-SL-DC5V DS4E-SL-DC6V DS4E-SL-DC9V DS4E-SL-DC12V DS4E-SL-DC24V DS4E-SL-DC48V 1 Form C DS1E-ML2-DC1.5V DS1E-ML2-DC3V DS1E-ML2-DC5V DS1E-ML2-DC6V DS1E-ML2-DC9V DS1E-ML2-DC12V DS1E-ML2-DC24V DS1E-ML2-DC48V DS1E-SL2-DC1.5V DS1E-SL2-DC3V DS1E-SL2-DC5V DS1E-SL2-DC6V DS1E-SL2-DC9V DS1E-SL2-DC12V DS1E-SL2-DC24V DS1E-SL2-DC48V Part No. 2 Form C DS2E-ML2-DC1.5V DS2E-ML2-DC3V DS2E-ML2-DC5V DS2E-ML2-DC6V DS2E-ML2-DC9V DS2E-ML2-DC12V DS2E-ML2-DC24V DS2E-ML2-DC48V DS2E-SL2-DC1.5V DS2E-SL2-DC3V DS2E-SL2-DC5V DS2E-SL2-DC6V DS2E-SL2-DC9V DS2E-SL2-DC12V DS2E-SL2-DC24V DS2E-SL2-DC48V 4 Form C DS4E-ML2-DC1.5V DS4E-ML2-DC3V DS4E-ML2-DC5V DS4E-ML2-DC6V DS4E-ML2-DC9V DS4E-ML2-DC12V DS4E-ML2-DC24V DS4E-ML2-DC48V DS4E-SL2-DC1.5V DS4E-SL2-DC3V DS4E-SL2-DC5V DS4E-SL2-DC6V DS4E-SL2-DC9V DS4E-SL2-DC12V DS4E-SL2-DC24V DS4E-SL2-DC48V 1 coil latching Nominal Voltage, V DC 1.5 3 5 6 9 12 24 48 1.5 3 5 6 9 12 24 48 M (180 mW) type S (90 mW) type 2 coil latching Nominal Voltage, V DC M (360 mW) type S (180 mW) type 1.5 3 5 6 9 12 24 48 1.5 3 5 6 9 12 24 48 Notes: 1. Reverse polarity types available (add suffix-R). 2. Standard packing: carton: 50 pcs.; case: 500 pcs. 2 ds_61005_0001_en_ds: 061006J DS COIL DATA (at 20°C 68°F) Single side stable Nominal voltage, V DC M type S type 1.5 3 5 6 9 12 24 48 1.5 3 5 6 9 12 24 48 Pick-up voltage, V DC (max.) 1 Form C 1.05 2.1 3.5 4.2 6.3 8.4 16.8 33.6 1.2 2.4 4.0 4.8 7.2 9.6 19.2 38.4 2, 4 Form C 1.05 2.1 3.5 4.2 6.3 8.4 16.8 33.6 1.05 2.1 3.5 4.2 6.3 8.4 16.8 33.6 Drop-out voltage, V DC (min.) Coil resistance, Ω (±10%) 0.15 0.3 0.5 0.6 0.9 1.2 2.4 4.8 0.15 0.3 0.5 0.6 0.9 1.2 2.4 4.8 5.63 22.5 62.5 90 203 360 1440 5760 11.3 45 125 180 405 720 2880 11520 Maximum allowable, V DC (at 50°C 122°F) 1 Form C 2, 4 Form C 1.8 2.25 3.6 4.5 6 7.5 7.2 9 10.8 13.5 14.4 18 28.8 36 57.6 72 2.4 3 4.8 6 8.0 10 9.6 12 14.4 18 19.2 24 38.4 48 76.8 96 1 coil latching Nominal voltage, V DC 1.5 3 5 6 9 12 24 48 1.5 3 5 6 9 12 24 48 M type S type Reset Set, V DC (max.) 1 Form C 1.05 2.1 3.5 4.2 6.3 8.4 16.8 33.6 1.2 2.4 4.0 4.8 7.2 9.6 19.2 38.4 Coil resistance, Ω (±10%) 2, 4 Form C 1.05 2.1 3.5 4.2 6.3 8.4 16.8 33.6 1.05 2.1 3.5 4.2 6.3 8.4 16.8 33.6 12.5 50 139 200 450 800 3200 12800 25 100 278 400 900 1600 6400 25600 Maximum allowable, V DC (at 50°C 122°F) 1 Form C 2, 4 Form C 1.8 2.25 3.6 4.5 6 7.5 7.2 9 10.8 13.5 14.4 18 28.8 36 57.6 72 2.4 3 4.8 6 8.0 10 9.6 12 14.4 18 19.2 24 38.4 48 76.8 96 2 coil latching Nominal voltage, V DC M type S type 1.5 3 5 6 9 12 24 48 1.5 3 5 6 9 12 24 48 ds_61005_0001_en_ds: 061006J Reset Set, V DC (max.) 1 Form C 1.05 2.1 3.5 4.2 6.3 8.4 16.8 33.6 1.2 2.4 4.0 4.8 7.2 9.6 19.2 38.4 2,4 Form C 1.05 2.1 3.5 4.2 6.3 8.4 16.8 33.6 1.05 2.1 3.5 4.2 6.3 8.4 16.8 33.6 Coil resistance, Ω (±10%) Coil l Coil ll 6.25 25 69.4 100 225 400 1600 6400 12.5 50 139 200 450 800 3200 12800 Maximum allowable, V DC (at 50°C 122°F) 1 Form C 2,4 Form C 1.8 2.25 3.6 4.5 6 7.5 7.2 9 10.8 13.5 14.4 18 28.8 36 57.6 72 2.4 3 4.8 6 8.0 10 9.6 12 14.4 18 19.2 24 38.4 48 76.8 96 3 DS DIMENSIONS mm inch 1 Form C PC board pattern (Copper-side view) Single side stable, 1 coil latching 2 coil latching Single side stable, 1 coil latching, 2 coil latching 15 .590 15 .590 5-0.9 dia 5-.035 dia 9.9 .390 9.3 9.9 .366 .340 2.54 .100 0.6 .024 3.4 .134 5.08 .200 7.62 .300 0.6 .024 5.08 .200 7.62 .300 6-0.9 dia 6-.035 dia 2.54 .100 2.54 .100 7.62 .300 7.62 .300 5.6 .221 0.6 .024 2.54 .100 Tolerance: ±0.1 ±.004 7.62 .300 General tolerance: ±0.3 ±.012 Schematic (Bottom view) Single side stable Deenergized condition 1 + 2 coil latching 1 coil latching 1 — 6 - 6 + 1 + 3 — 6 + SET RST SET RST 12 10 N.O. N.C. COM 12 10 7 • A polarity bar showing the relay direction can replace the schematic. SET RST 12 10 COM 7 Diagram shows the “reset” position when terminals 1 and 6 are energized. Energize with reverse polarity to transfer contacts. 2 Form C COM 7 Diagram shows the “reset” position when terminals 3 and 6 are energized. Energize terminals 1 and 3 to transfer contacts. PC board pattern (Copper-side view) Single side stable, 1 coil latching 2 coil latching Single side stable, 1 coil latching, 2 coil latching 8-0.9 dia 8-.035 dia 9.9 .390 20 .787 20 .787 9.3 9.9 .366 .340 2.54 .100 0.6 .024 3.4 .134 5.08 5.08 .200 .200 0.6 .024 0.6 .024 7.62 .300 5.08 5.08 5.08 .200 .200 .200 2.54 .100 10-0.9 dia 10-.035 dia 2.54 .100 7.62 .300 2.54 .100 2.54 .100 7.62 .300 matching 16 pin IC socket 5.6 .221 Tolerance: ±0.1 ±.004 7.62 .300 General tolerance: ±0.3 ±.012 16 - N.O. N.C. COM + 8 6 4 1 • A polarity bar showing the relay direction can replace the schematic. 4 9 11 13 SET RST COM 16 + 9 11 13 15 16 SET RST COM — — SET RST COM 8 6 4 — 1 SET RST COM + + 8 6 4 2 1 Diagram shows the “reset” position when terminals 1 and 16 are energized. Energize with reverse polarity to transfer contacts. Set 9 11 13 N.O. N.C. COM 2 coil latching 1 coil latching Reset Schematic (Bottom view) Single side stable Deenergized condition Diagram shows the “reset” position when terminals 2 and 15 are energized. Energize terminals 1 and 16 to transfer contacts. ds_61005_0001_en_ds: 061006J DS 4 Form C mm inch Single side stable, 1 coil latching, 2 coil latching 35.24 1.387 35.24 1.387 9.9 .390 9.3 9.9 .366 .340 0.6 .024 3.4 .134 5.08 5.08 .200 .200 7.62 .300 5.08 5.08 5.08 .200 .200 .200 0.6 .024 5.08 5.08 5.08 5.08 5.08 5.08 .200 .200 .200 2.54.200 .200 .200 .100 0.6 .024 5.6 .221 7.62 .300 General tolerance: ±0.3 ±.012 PC board pattern (Copper-side view) Single side stable, 1 coil latching 14-0.9 dia 14-.035 dia 2.54 .100 2 coil latching 16-0.9 dia 16-.035 dia 2.54 .100 2.54 .100 7.62 .300 2.54 .100 7.62 .300 2.54 × 2 2.54 × 2 2.54 × 3 2.54 × 2 2.54 × 2 2.54 × 2 .100 × 2 .100 × 2 .100 × 3 .100 × 2 .100 × 2 .100 × 2 2.54 × 2 2.54 × 2 2.54 × 2 2.54 2.54 × 2 2.54 × 2 2.54 × 2 .100 × 2 .100 × 2 .100 × 2 .100 .100 × 2 .100 × 2 .100 × 2 Tolerance: ±0.1 ±.004 N.O. N.C. COM + COM N.C. N.O. 7 8 6 4 1 3 5 • A polarity bar showing the relay direction can replace the schematic. 9 11 13 16 14 12 10 SET RST COM + COM RST SET 9 11 13 1516 14 12 10 SET RST COM ——COM RST SET SET RST COM —COM RST SET 7 8 6 4 1 3 5 SET RST COM + + COM RST SET 7 8 6 4 2 1 3 5 Set 9 11 13 16 14 12 10 N.O. N.C. COM - COM N.C.N.O. 2 coil latching 1 coil latching Reset Schematic (Bottom view) Single side stable Deenergized condition Diagram shows the “reset” position when terminals 1 and 16 are energized. Energize with reverse polarity to transfer contacts. Diagram shows the “reset” position when terminals 2 and 15 are energized. Energize terminals 1 and 16 to transfer contacts. 2. Life curve (Resistive load) 3. Contact reliability for AC loads REFERENCE DATA 1. Maximum switching capacity Sample: DS2E-M-DC24V 10 pcs. Cycle rate: 20 cpm. Detection level: 200 mΩ 2.0 1.0 0.5 Weibull probability data 0.2 10mV 10μA 100mA 1A Switching current ds_61005_0001_en_ds: 061006J 0 1 2 Switching current, A 0.1 250 125 V DC 0.5A 5.0 10 0.3A 10.0 VA C 125V AC 70.0 50.0 30.0 1 A 2 A 12 50V 5V AC AC 10V 100 30 V DC 99.9 99.0 95.0 0.5 No. of operations, ×104 Contact voltage 100V F(t), % 1,000 1,000V 0 10 100 No. of operations, ×104 1,000 5 DS 4-(1). Coil termperature rise (2 Form C single side stable type) 4-(2). Coil tempeature rise (4 Form C single side stable type) 4-(3). Coil temperature rise (2 Form C 2 coil latching type) Tested sample: DS2E-M-DC12V Point measured: Inside the coil Ambient temperature: 18° to 19°C 64° to 66°F Tested sample: DS4E-M-DC12V Point measured: Inside the coil Ambient temperature: 17° to 18°C 63° to 64°F Tested sample: DS2E-ML2-DC12V Point measured: Inside the coil Ambient temperature: 20° to 21°C 68° to 70°F 3A 60 60 50 50 30 2A 30 20 20 10 10 100 0 110 Coil applied voltage, %V 0A 100 5. Operate and release time characteristics (2 Form C single side stable type) Tested sample: DS4E-ML2-DC12V Point measured: Inside the coil Ambient temperature: 20°C 68°F Test condition: Without diode connected to coil in parallel 30 20 Reset coil Set coil 10 0 100 110 Coil applied voltage, %V Rate of change, % Rate of change, % Pick-up voltage ON -10 10 0 Drop-out voltage OFF Release time (mean) 1 80 100 110 Coil applied voltage, %V Pick-up voltage (1) (2) (3) OFF OFF ON ON OFF OFF ON ON 0 -10 10 Drop-out voltage 0 -10 5 10 .197 .394 Inter-relay distance , mm inch OFF 60 40 OFF ON OFF ON 20 0 OFF OFF -20 (1) (2) (3) Drop-out voltage OFF OFF ON ON OFF OFF ON ON 20 0 -20 -60 -80 -80 5 10 .197 .394 Inter-relay distance , mm inch 40 ON -60 -10 60 -40 ON ON 80 (1) (2) (3) Pick-up voltage -40 ON 10 100 120 Coil applied voltage, % 80 OFF 0 ON Reset coil Set coil 6-(3). Influence of adjacent mounting (4 Form C) (1) (2) (3) OFF Operate time (mean) 2 0 6-(2). Influence of adjacent mounting (2 Form C) 10 3 Rate of change, % 0A Operate and release time, ms 2A 40 Rate of change, % Temperature rise, °C 50 20 6-(1). Influence of adjacent mounting (1 Form C) 4 3A 0A 30 0 110 Coil applied voltage, %V 4-(4). Coil temperature rise (4 Form C 2 coil latching type) 60 2A 40 10 Rate of change, % 0 3A 40 Rate of change, % 0A 40 Temperature rise, °C 3A 2A 50 Temperature rise, °C Temperature rise, °C 60 10 20 .394 .787 Inter-relay distance , mm inch 10 20 .394 .787 Inter-relay distance , mm inch For Cautions for Use, see Relay Technical Information. 6 ds_61005_0001_en_ds: 061006J