LED light engine / OLED LED compact Uengine STARK DLE TWIST CLASSIC STARK DLE TWIST Product description T • Complete LED Light Engine with integrated LED control gear and suitable holder • High system efficiency U (60 lm/W at 3,000 K and 70 lm/W at 4,000 K) • White diffuser for a uniform and neutral appearance • No tools required for installing the LED light engine • For luminaire installation • Long lifetime: 50,000 hours O • Standardised lumen packages for precise and sustainable lighting planning Ø70 • High colour rendering index (CRI > 80) 20 40 • 5-year sytem guarantee on the complete product AC voltage range2 220 – 240 V 179 – 305 V 50 / 60 Hz Typ. current 0.071 A Typ. λ > 0.9 Ambient temperature ta -25 ... +40 °C Typ. tc point1 65 °C Risk group (EN 62471:2008) 0 THD 45 % Beam characteristic È 1 AS E Mains frequency2 Ø65,5 Ø58 Rated supply voltage2 D Technical data 1 The tc-point is situated in centre of the bottom side Ordering data 103° Type Article number Colour temperature Packaging carton Weight per pc. STARK DLE TST F 1100 830 CLA 25000749 3,000 K 40 pc(s). 0.1 kg STARK DLE TST F 1100 840 CLA3 25000750 4,000 K 40 pc(s). 0.1 kg Accessories connection cable, page 2 Standards, page 3 PH Colour temperatures and tolerances, page 5 Specific technical data Photometric code Typ. luminous flux2 Power consumption light engine Typ. efficacy of the light engine STARK DLE TST F 1100 830 CLA 830 / 5x9 1,100 lm 18.3 W 60 lm/W > 80 STARK DLE TST F 1100 840 CLA3 840 / 5x9 1,100 lm 15.5 W 70 lm/W > 80 Type Colour rendering index CRI All values at ta = 25 °C, tc = 65 °C. 1 If the max. temperature limits are exceeded, the life of the system will be greatly reduced or the system may be damaged. The temperature of the uengine at the tc-point is to be measured in the thermally stable state with a temperature sensor or or temperature-sensitive sticker as per EN 60598-1. For the precise position of the tc point see the drawing above. 2 Tolerance 3 Available range for optical and electrical data: ±10 %. at 02/2012. Data sheet 08/13-LED075-2 Subject to change without notice. www.tridonic.com 1 ACCESSORIES LED light engine / OLED LED compact TALEXXaccessories SOCKET LH 1/2 65-2 Ø78 Product description • Attached with M3 cheese or button head screws 11,4 T 19,1 • Lampholder for uengine STARK DLE TWIST Ø93,1 • Casing: polycarbonat, white 120° U Rated voltage 300 V Rated current 2A Push terminal 0.5 – 1.5 mm² O Technical data Ø66,5 Ø79,5 120° • ZHAGA code: PHJ65D-2 120° Ordering data Type Article number Packaging carton Weight per pc. 88167495 0.023 kg 100 pc(s). PH AS E D LH 1/2 65-2 Data sheet 08/13-LED075-2 Subject to change without notice. www.tridonic.com 2 LED light engine / OLED LED compact Mounting instruction Considered standards • EN 55015 • EN 60589-1 • EN 60929 • EN 61000-3-2 • EN 61000-3-3 • EN 61547 • EN 62031 • EN 62384 • EN 62471 • EN 61347-1 • EN 61347-2-13 uengine STARK DLE TWIST from Tridonic must be installed on a heat sink. The fixing/cooling surface must be cleaned before installing the u modules to remove all dirt, dust and grease. The protective film at the back of uengine STARK DLE TWIST must be removed before mounting on the heat sink. The unit can be fixed in place with a twisting motion. T Replacement by bajonet catch is possible in every operation mode. Take care when removing the LED light engine because the bottom may be hot (up to 65 °C). U Glow wire test according to IEC 60695-2-11 960 °C passed. Photometric code Chemical substance may harm the LED module. Chemical reactions could lead to colour shift, reduced luminous flux or a total failure of the module caused by corrosion of electrical connections. 2nd + 3rd digit 4th digit 5th digit 6th digit Lumen maintanance after 25% McAdams after of the lifetime (max.6000h) Code CRI Code Remaining lumen Colour temperature in McAdams 25% of the 7 67 – 76 7 ≥ 70 % lifetime Kelvin x 100 initial 8 77 – 86 8 ≥ 80 % (max.6000h) 9 87 – ≥90 9 ≥ 90 % Materials which are used in LED applications (e.g. sealings, adhesives) must not produce dissolver gas. They must not be condensation curing based, acetate curing based or contain sulfur, chlorine or phthalate. Avoid corrosive atmosphere during usage and storage. Heat sink values D 1st digit O Key for photometric code, e. g. 830 / 559 AS E Thermal design and heat sink The rated life of u products depends to a large extent on the temperature. If the permissible temperature limits are exceeded, the life of the uengine STARK DLE TWIST will be greatly reduced or the uengine STARK DLE TWIST may be destroyed. Therefore the uengine STARK DLE TWIST needs to be mounted onto a heat sink. Tridonic’s excellent thermal design for the uengine STARK DLE TWIST products provides the lowest thermal resistance and therefore allowing new compact designs without sacrificing quality, safety and life time. tc point, ambient temperature and lifetime The temperature at tc reference point is crucial for the light output and life time of a u product. PH For uengine STARK DLE TWIST a tc temperature of 65 °C has to be complied in order to achieve an optimum between heat sink requirements, light output and life time. Compliance with the maximum permissible reference temperature at the tc point must be checked under operating conditions in a thermally stable state. The maximum value must be determined under worst-case conditions for the relevant application. The tc temperature is meassured in the middle of the bottom of the LED light engine. Uengine STARK DLE TWIST CLASSIC 1,100 lm ta tc Rth, hs-a 25 °C 65 °C 2.2 K/W 35 °C 65 °C 1.6 K/W 40 °C 65 °C 1.4 K/W Notes Values valid for: natural convection, heat sink material: aluminium ≥ 1 mm thick, Rth, hs-a = required thermal resistance of heat sink The actual cooling surface can differ because of the material, the structural shape, outside influences and the installation situation. A thermal connection between umodule STARK DLE and heat sink with heat-conducting paste or heat conducting adhesive film is absolutely necessary. Check leaflet “STARK DLE TWIST” for recommended heat sinks, see www.tridonic.com Thermal behaviour storage temperature operating temperature tc max. (at typ. current) max. rel. humidity -40 ... +80 °C -25 ... +40 °C 65 °C 0 ... 80 % The LED light engine have to be within the specified operating temperature range (ta) before they can be operated. Data sheet 08/13-LED075-2 Subject to change without notice. heat sink surface 524 cm² 920 cm² 1,595 cm² www.tridonic.com 3 LED light engine / OLED LED compact Relative luminous flux Lumen maintenance luminous flux in % operating time in h 80 70 50 80 70 50 80 70 50 40.000 60.000 100.000 35.000 55.000 95.000 30.000 50.000 90.000 55 65 1,12 1,1 1,08 1,06 1,04 1,02 1 T 45 1,14 relative luminous flux [a.u.] tc temperature in °C 0,98 0,96 0,92 20 U 0,94 30 40 50 Tc [°C] 60 70 75 O The diagrams based on statistic values. The real values can be different. Wiring Uengine STARK DLE TWIST CLASSIC AS E D L N 220–240 V 50/60 Hz Luminaire / Heat sink Uaccessories SOCKET LH 1/2 65-2 Wiring type and cross section The wiring can be solid cable with a cross section of 0.5 to 1.5 mm². For the push-wire connection you have to strip the insulation (8 – 9.5 mm). PH wire preparation: 0.5 – 1.5 mm² 8 – 9.5 mm Maximum loading of automatic circuit breakers Automatic circuit breaker type C10 C13 C16 C20 B10 B13 B16 B20 1.5 mm2 1.5 mm2 1.5 mm2 2.5 mm2 1.5 mm2 1.5 mm2 1.5 mm2 2.5 mm2 Imax time STARK DLE TST F 1100 830 CLA 125 162 200 250 125 162 200 250 5A 380 µs STARK DLE TST F 1100 840 CLA 125 162 200 250 125 162 200 250 5A 380 µs Installation Ø Data sheet 08/13-LED075-2 Subject to change without notice. www.tridonic.com Inrush current 4 LED light engine / OLED LED compact Optical characteristics Umodule STARK DLE The optical design of the umodule STARK DLE product line ensures optimum homogenity for the light distribution. Umodule STARK DLE CLASSIC 103°: Light distribution 0° 10° 20° 30° 40° -40° 50° -50° 60 -60° 60° 40 70° 80° 20 -100 -80 -60 -40 -20 0 20 40 60 80 100 90° D O -90° U relative intensity Iv/Iv,max 80 -10° T -30° 100 -20° PH AS E For further information see Design-in Guide, 3D data and photometric data on www.tridonic.com or on request. Data sheet 08/13-LED075-2 Subject to change without notice. www.tridonic.com 5 LED light engine / OLED LED compact Coordinates and tolerances according to CIE 1931 The specified colour coordinates are measured by a current impulse with typical values of module and a duration of 100 ms. The ambient temperature of the measurement is ta = 25 °C. The measurement tolerance of the colour coordinates are ± 0.01. 3,000 K y0 0,4032 0,4250 T x0 0,4344 Centre 100 0,4200 0,4050 0,4000 0,3950 60 40 20 0,3900 0,4550 0,4500 0,4450 0,4400 0,4350 0,4300 0,4250 0,4150 0,4200 0,3850 0 380 420 460 500 540 580 620 660 wave length [nm] 700 740 780 460 500 540 580 620 660 wave length [nm] 700 740 780 MacAdam Ellipse: 5SDCM Mittelpunkt 0,4000 0,3950 0,3900 0,3850 0,3800 0,3750 y0 0,3803 PH 0,3700 x0 0,3828 norm. intensity [%] 4.000 K AS E D U 0,4100 80 O norm. intensity [%] 0,4150 100 80 60 40 20 0,3650 0,4000 0,3950 0,3900 0,3850 0,3800 0,3750 0,3700 0,3650 0,3600 0,3600 0 380 420 MacAdam Ellipse: 5SDCM Data sheet 08/13-LED075-2 Subject to change without notice. www.tridonic.com 6