Transcript
LED light engine / OLED LED compact
Umodule RECTANGULAR P440-2 umodule EOS
Product description • Street lighting • High-flux LED module • Narrow colour temperature tolerance band • Compact design • Excellent thermal management3 • NTC for temperature control • High-power LED in chip-on-board technololgy • Beam characteristic: 140° • Uniform distribution of light • Built-in LED module
5,05
1,65 3,20
• Fixing holes for M3 screws • Cooling required
70
3,5
Ø3,2
tc
NTC
Technical data 40 W
Ambient temperature range
-30 ... +55 °C
tp rated
65 °C
tc3
85 °C
Max. DC forward current2
1,400 mA
Max. permissible LF current ripple
2,000 mA
Max. permissible peak current
3,000 mA / max. 10 ms
Risk group (EN 62471:2008)
0
25 18
+
Typ. power at 1,050 mA1 6
– 15
20
20
Ordering data
È Standards, page 2 Colour temperatures and tolerances, page 5
Type
Article number Colour temperature4 5 Packaging carton Weight per pc.
LED P440-2 3000K 70x25
89601161
3,000 K
20 pc(s).
0.008 kg
LED P440-2 4000K 70x25
89601162
4,000 K
20 pc(s).
0.008 kg
LED P440-2 5000K 70x25
89601155
5,000 K
20 pc(s).
0.008 kg
Specific technical data Type
Photometric Min. Luminous flux at Typ. Luminous flux at code 1,050 mA6 7 1,050 mA6 7
Typ. Forward current2 8
Max. Forward current2 8
Min. Forward voltage1 6
Typ. Forward voltage1 6
Max. Forward voltage1 6
Colour rendering index CRI5
LED P440-2 3000K 70x25
830/4x9
2,400 lm
2,700 lm
1,050 mA
1,400 mA
33.3 V
38 V
44.8 V
> 80
LED P440-2 4000K 70x25
840/4x9
2,700 lm
3,000 lm
1,050 mA
1,400 mA
33.3 V
38 V
44.8 V
> 80
LED P440-2 5000K 70x25
750/4x9
3,400 lm
3,800 lm
1,050 mA
1,400 mA
33.3 V
38 V
44.8 V
> 70
1 Tolerance
range for electrical data: ±15 %.
2 Permitted
current range see diagram on page 2. Exceeding the maximum operating current leads to an overload of the umodule RECTANGULAR. This may in turn result in a significant reduction of life-time or even in damage of the umodule RECTANGULAR.
3 If
the maximum temperature limits are exceeded, the life of the module will be greatly reduced or the module may be damaged. The temperature of the umodule RECTANGULAR at the tc point in the thermally stable state by mean of a temperature sensor or temperature-sensitive sticker as per EN 60598-1. For the precise position of the tc point see the drawing above. For details please refer to page 2.
4 Colour
coordinates and tolerances according to CIE 1964. For details please refer to page 5.
5 Colour
temperature and CRI according to CIE 1931.
6 At
tp = 65 °C
7 Tolerance 8 Max.
range for optical data: ±15 %.
permissible surge current: 3 A, duration max. 10 μs
Alle Angaben für ta = 25 °C.
Data sheet 12/15-971-8 Subject to change without notice.
www.tridonic.com
1
LED light engine / OLED LED compact
Standards EN 62031 EN 62471
Chemical substance may harm the LED module. Chemical reactions could lead to colour shift, reduced luminous flux or a total failure of the module caused by corrosion of electrical connections. Materials which are used in LED applications (e.g. sealings, adhesives) must not produce dissolver gas. They must not be condensation curing based, acetate curing based or contain sulfur, chlorine or phthalate. Avoid corrosive atmosphere during usage and storage.
Photometric code Key for photometric code, e. g. 830 / 559 1st digit
2nd + 3rd digit
4th digit
5th digit
6th digit Lumen maintanance after 25% McAdam after of the life-time (max.6000h) Code CRI Code Remaining lumen 25% of the Colour temperature in McAdam 7 67 – 76 7 ≥ 70 % life-time Kelvin x 100 initial 8 77 – 86 8 ≥ 80 % (max.6000h) 9 87 – ≥90 9 ≥ 90 %
Energy classification Type P440-2 3000K 70x25 P440-2 4000K 70x25 P440-2 5000K 70x25
Forward current 1,050 mA 1,050 mA 1,050 mA
Energy classification A A A+
Thermal design and heat sink The rated life of u products depends to a large extent on the temperature. If the permissible temperature limits are exceeded, the life of the umodule RECTANGULAR will be greatly reduced or the umodule RECTANGULAR may be destroyed.
EOS/ESD safety guidelines The device / module contains components that are sensitive to electrostatic discharge and may only be installed in the factory and on site if appropriate EOS/ESD protection measures have been taken. No special measures need be taken for devices/modules with enclosed casings (contact with the pc board not possible), just normal installation practice. Please note the requirements set out in the document EOS / ESD guidelines (Guideline_EOS_ESD.pdf) at: http://www.tridonic.com/esd-protection Temperature control An NTC resistor is on the board of the umodule RECTANGULAR P440-2 to control the tc temperature during the operation. Exact position see drawing on page 1. The details of the 220 kΩ NTC (order number B57431V2223J062) you can find in the data sheet of the manufacturer AVX (Nr. NB12QØØ224). T
R25 = 220 kΩ, B25 / 100 = 4,500 K RT / R25
α
25 °C
1.0000
4.72 % / K
30 °C
0.7944
4.60 % / K
35 °C
0.6347
4.48 % / K
Tridonic’s excellent thermal design for the umodule RECTANGULAR products provides the lowest thermal resistance and therefore allowing new compact designs without sacrificing quality, safety and life-time.
40 °C
0.5099
4.37 % / K
45 °C
0.4119
4.26 % / K
50 °C
0.3345
4.15 % / K
tc point, ambient temperature and life-time The temperature at tc reference point is crucial for the light output and life-time of a u product.
55 °C
0.2730
4.05 % / K
60 °C
0.2239
3.95 % / K
65 °C
0.1846
3.85 % / K
For umodule RECTANGULAR P440-2 a tc temperature of 65 °C has to be complied in order to achieve an optimum between heat sink requirements, light output and life-time.
70 °C
0.1529
3.75 % / K
75 °C
0.1272
3.66 % / K
80 °C
0.1063
3.57 % / K
85 °C
0.08928
3.48 % / K
Therefore the umodule RECTANGULAR P440-2 needs to be mounted onto a heat sink.
Compliance with the maximum permissible reference temperature at the tc point must be checked under operating conditions in a thermally stable state. The maximum value must be determined under worst-case conditions for the relevant application. Mounting instruction umodule RECTANGULAR from Tridonic which have to be installed on a heat sink have to be connected with heat-conducting paste or heat conducting adhesive film and fixed with M3 plastic screws. The fixing/cooling surface must be cleaned before installing the u modules to remove all dirt, dust and grease. None of the components of the umodule RECTANGULAR (substrate, LED, electronic components etc.) may be exposed to tensile or compressive stresses.
Data sheet 12/15-971-8 Subject to change without notice.
www.tridonic.com
2
LED light engine / OLED LED compact
Typical heat sink surface Umodule RECTANGULAR P440-2, 1,050 mA ta tc Rth, hs-a 25 °C 65 °C 0.96 K/W 30 °C 65 °C 0.82 K/W 40 °C 65 °C 0.54 K/W 50 °C 65 °C 0.25 K/W
typical heat sink surface 693 cm² 813 cm² 1,241 cm² 2,620 cm²
Umodule RECTANGULAR P440-2, 1,400 mA ta tc Rth, hs-a 25 °C 65 °C 0.60 K/W 30 °C 65 °C 0.49 K/W 40 °C 65 °C 0.39 K/W 50 °C 65 °C 0.08 K/W
typical heat sink surface 1,110 cm² 1,350 cm² 2,300 cm² 7,920 cm²
Electrical supply/choice of LED Driver umodule RECTANGULAR from Tridonic are not protected against overvoltages, overcurrents, overloads or short-circuit currents. Safe and reliable operation can only be guaranteed in conjunction with a LED Driver which complies with the relevant standards. The use of uconverter from Tridonic in combination with umodule RECTANGULAR guarantees the necessary protection for safe and reliable operation. If a LED Driver other than Tridonic uconverter is used, it must provide the following protection: • Short-circuit protection • Overload protection • Overtemperature protection umodule RECTANGULAR P440-2 must be supplied by a constant current LED Driver. Operation with a constant voltage LED Driver will lead to an irreversible damage of the module.
Notes Values valid for: natural convection, heat sink material: aluminium ≥ 1 mm thick, Rth, hs-a = required thermal resistance of heat sink The actual cooling surface can differ because of the material, the structural shape, outside influences and the installation situation. A thermal connection between umodule RECTANGULAR and heat sink with heat-conducting paste or heat conducting adhesive film is absolutely necessary. Additionally the umodule RECTANGULAR has to be fixed on the heat sink with M3 plastic screws to optimise the thermal connection.
Wrong polarity can damage the uspot P440-2 module. Life-time Life-time declarations are informative and represent no warranty claim. tc temperature in °C 25
Storage and humidity 45 storage temperature
-30 ... +80 °C
Operation only in non condensing environment. Humidity during processing of the module should be between 30 to 70 %.
65
75
1600 85
1400
If [mA]
1200
luminous flux in %
life-time in h
80 70 50 80 70 50 80 70 50 80 70 50 80 70 50
29,000 47,000 91,000 28,000 45,000 87,000 26,000 42,000 81,000 23,000 35,000 75,000 15,000 22,000 49,000
1000 800
Plug connection
600 400 200 0
0
10
20
30
40
50 60 Tc [°C]
70
80
90
+
100
–
+ NTC NTC –
Type: PTSM 0,5/4-2,5-H SMD R44 wire preparation: 0.2 – 0.5 mm 2
6 – 7 mm
Data sheet 12/15-971-8 Subject to change without notice.
www.tridonic.com
3
LED light engine / OLED LED compact
Relative forward voltage and relative luminous flux 1,1
1,05 1,04
1,05
1,03 rel. voltage [a.u.]
rel. voltage [a. u.]
1
0,95 0,9
1,02 1,01 1
0,99 0,85 0,8
0,98 0
250
750
500
1000
1250
current [mA]
0,97 20
1500 1400
30
40
30
40
50 Tc [°C]
60
70
80
85
60
70
80
85
Relative forward voltage at tc = 65 °C
1,14
1,8
1,12
1,6
1,1 rel. luminous flux [a.u.]
rel. luminous flux [a. u.]
1,4 1,2 1 0,8 0,6
1,06 1,04 1,02 1 0,98 0,96
0,4 0,2
1,08
0,94 0
250
750
500
1000
1250
current [mA]
0,92 20
1500 1400
50 Tc [°C]
Relative luminous flux at tc = 65 °C
The diagrams based on statistic values. The real values can be different. Optical characteristics Umodule RECTANGULAR P440-2
For further information see Design-in Guide, 3D data and photometric data on www.tridonic.com or on request.
The optical design of the umodule RECTANGULAR product line ensures optimum homogenity for the light distribution. Umodule RECTANGULAR P440-2 140°: Light distribution
-30°
relative intensity Iv/Iv, max
100 80
-20°
-10°
0°
10°
20°
30° 40°
-40°
50°
-50°
60 -60°
60°
40
70° 80°
20
-90°
-100 -80 -60 -40 -20
0
20
40
60
80 100
90°
Data sheet 12/15-971-8 Subject to change without notice.
www.tridonic.com
4
LED light engine / OLED LED compact
Coordinates and tolerances according to CIE 1964 The specified colour coordinates are measured by a current impulse of 1,050 mA and a duration of 100 ms. The ambient temperature of the measurement is ta = 25 °C. The measurement tolerance of the colour coordinates are ± 0.01.
3,000 K x0 0,4460
Centre
y0 0,3990
100
0,4200 0,4150
80 norm. intensity [%]
0,4100 0,4050 0,4000 0,3950
60
40
0,3900
20 0,3850
0
0,4650
0,4600
0,4550
0,4500
0,4450
0,4400
0,4350
0,4300
0,4250
0,3800
380
420
460
500
540
580
620
660
700
740
780
660
700
740
780
wave length [nm]
MacAdam ellipse: 4SDCM
4,000 K x0 0,3860
Centre
y0 0,3780
100
0.4000 0.3950
80
0.3900
norm. intensity [%]
0.3850 0.3800 0.3750 0.3700
60
40
20 0.3650
0.4050
0.4000
0.3950
0.3900
0.3850
0.3800
0.3750
0.3700
0.3650
0.3600
0 380
460
500
540
580
620
wave length [nm]
MacAdam ellipse: 4SDCM
Data sheet 12/15-971-8 Subject to change without notice.
420
www.tridonic.com
5
LED light engine / OLED LED compact
5,000 K x0 0,3530
Centre
y0 0,3590
100
0,3800 0,3750
80 norm. intensity [%]
0,3700 0,3650 0,3600 0,3550 0,3500
60 40 20
0,3450
0,3750
0,3700
0,3650
0,3600
0,3550
0,3500
0,3450
0,3400
0,3350
0,3400
0 380
420
460
500
540 580 620 660 wave length [nm]
700
740
780
MacAdam ellipse: 4SDCM
Data sheet 12/15-971-8 Subject to change without notice.
www.tridonic.com
6